Mettler Toledo ReactIR 45m User manual

Type
User manual
ReactIR
45M
In Situ
FTIR Spectroscopy
January 2014
MK-PB-0114-AC Rev A
DCN 2397
Hardware Manual
© 2014 Mettler-Toledo AutoChem, Inc.
All world rights reserved.
Printed in the USA.
No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including but not
limited to photocopy, photograph, magnetic or other record, without the prior written permission of Mettler-Toledo
AutoChem, Inc.
28 January 2014
iC IR
TM
, ReactIR
TM
iC Process
TM
, Sentinel
TM
, FiberComp
TM
, DiComp
TM
, and SiComp
TM
are trademarks of Mettler-Toledo
AutoChem, Inc.
Microsoft® and Windows® are either trademarks or registered trademarks of Microsoft Corporation in the United States
and/or other countries.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Address comments to:
Mettler-Toledo AutoChem, Inc.
7075 Samuel Morse Drive
Columbia, MD 21046
Tel: + 1 866.333.6822
Fax: +1 410.910.8600
www.mt.com/reactir
For technical support, contact:
The information in this publication is provided for reference only. All information contained in this publication is believed to
be correct and complete. Mettler-Toledo AutoChem, Inc., shall not be liable for errors contained herein nor for incidental or
consequential damages in connection with the furnishing, performance, or use of this material. All product specifications,
as well as the information contained in this publication, are subject to change without notice.
This publication may contain or reference information and products protected by copyrights or patents and do not convey
any license under the patent rights of Mettler-Toledo AutoChem, Inc., nor the rights of others. Mettler-Toledo AutoChem, Inc.
does not assume any liability arising out of any infringements of patents or other rights of third parties.
Mettler-Toledo AutoChem, Inc. makes no warranty of any kind with regard to this manual, including but not limited to the
implied warranties of merchantability and fitness for a particular purpose.
In conformance with the European Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE), this
device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific
requirements.
Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and
electronic equipment.
If you have any questions please contact the responsible authority or the distributor from which you purchased this device.
Should this device be passed onto other parties for private or professional use, the content of this regulation must also be
related.
Thank you for your contribution to environmental protection.
iiiReactIR™ 45m Hardware Manual
METTLER TOLEDO
Contents
Chapter 1 Introduction
General Policies ........................................................................ 8
Installation Policy ...........................................................................8
Repair Policy..................................................................................8
Computer Service Policy ..................................................................8
Software Upgrades..................................................................... 9
Training Programs ..................................................................... 9
Service and Technical Assistance................................................. 9
Chapter 2 Pre-Installation Checklist
[ ] Site Preparation ................................................................ 11
[ ] Space and Weight Requirements.............................................. 11
[ ] Area of Intended Use...............................................................12
[ ] Environmental Conditions........................................................12
[ ] Utilities..................................................................................12
[ ] Internal Paperwork and Approval for Installation.........................14
[ ] Standard and Optional Items .............................................. 14
[ ] Computer Specifications .................................................... 14
System Dimensions ................................................................. 15
Chapter 3 Product Description
Overview of the ReactIR 45m System ......................................... 17
Definition of Terms ........................................................................ 18
ReactIR 45m System Diagram .................................................. 18
ReactIR 45m Sampling Technology Configurations ...................... 19
DS FiberConduit Probe...................................................................19
DS Micro Flow Cell........................................................................21
DS Fiber-to-Sentinel.......................................................................22
DS Fiber-to-Gas Cell ......................................................................22
K4 Mirror Conduit/Sentinel .............................................................23
K6 Mirror Conduit/16 mm Probe.....................................................23
Chapter 4 Safety
Product Safety ......................................................................... 25
Compliance..................................................................................25
Laser Classification .......................................................................26
Grounding the Power Supply ..........................................................26
Operational Safety.........................................................................26
System Handling ..........................................................................27
MK-PB-0114-AC Rev A iv
METTLER TOLEDO
Contents
Chapter 5 Specifications
ReactIR 45m Base Unit.............................................................29
Purge .....................................................................................30
iC IR Computer Specifications ....................................................30
Chapter 6 Installation
Acceptance Criteria........................................................................31
Site Preparation (Customer Responsibility)..................................32
Installation Instructions .............................................................32
1. Confirm Site Readiness..............................................................32
2. Verify Hardware Configuration/Order Validation .............................32
3. Confirm Hardware Service Agreement and Software Version ...........33
4. Install iC IR Software .................................................................34
5. Perform Initial Setup and Establish System Connections ................34
6. Establish Sampling Technology Conduit Purge (if applicable) ........41
7. Apply Power to System and Verify LEDs ....................................... 42
8. Launch Software .......................................................................42
9. Configure ReactIR 45m Instrument in Control Software ..................44
Chapter 7 System Readiness
Preparing for ReactIR 45m Functional Tests ................................51
Conducting Functional Tests Using iC IR .....................................51
1. Check Alignment (Contrast and Align) .........................................52
2. Clean the Sensor.......................................................................59
3. Check System Performance ....................................................... 60
4. Check System Stability...............................................................66
6. Perform IPA Validation/Calibration (if applicable).......................... 68
Chapter 8 Routine Operation
ReactIR 45m LED Indicators......................................................77
Preparing for System Use ..........................................................78
Simple Steps to a Successful Experiment ....................................79
1. See An Overview of the Process .................................................79
2. Interface Sampling Technology with Your Chemistry .....................80
3. Align the Probe ........................................................................82
4. Clean the Sensor......................................................................83
5. Collect a Background ...............................................................86
6. Set the Data Collection Parameters............................................. 90
Best Practices..........................................................................90
vReactIR™ 45m Hardware Manual
METTLER TOLEDO
Chapter 9 Care and Maintenance
Service Contracts ..................................................................... 93
ReactIR 45m Base Unit..................................................................93
ReactIR 45m Sampling Technologies ..............................................94
Maintaining a ReactIR 45m System ........................................... 94
Recommended Maintenance Schedule.............................................95
Customer-Replaceable Parts...........................................................95
ReactIR 45m Relocation, Packaging, and Storage ....................... 95
Chapter 10 Troubleshooting and FAQs
Troubleshooting Tips ...............................................................97
FAQs ...................................................................................... 98
Appendix A ReactIR 45m Accessories and Options 99
Sampling Technologies ............................................................ 99
ServicePac Installation for ReactIR 45m ..................................... 99
IPA Module ........................................................................... 101
Appendix B ReactIR Glossary 103
General Terms ....................................................................... 103
Software Terms...................................................................... 104
Functional Tests ..........................................................................104
Hardware Terms .................................................................... 105
Index 107
MK-PB-0114-AC Rev A vi
METTLER TOLEDO
Contents
7ReactIR™ 45m Hardware Manual
METTLER TOLEDO
1
Introduction
ReactIR™ 45m is an FTIR-based, high performance, in situ reaction analysis system
designed specifically for the chemist and chemical engineer who require the highest level of
precision for kinetic studies and quantitative analysis. It provides real-time information on the
effect of changing reaction conditions such as solvent, catalyst, temperature, and reagent
addition rate, saving valuable resources. Based on the information provided by ReactIR 45m,
scientists are able to correlate, in real time, the impact of varying reaction conditions to
reaction performance—dramatically reducing development time.
This document contains a pre-installation checklist for site preparation, technical
specifications, system configurations, instrument installation and system readiness testing,
routine operation, safety information, as well as care and maintenance information,
troubleshooting tips, and a glossary.
Related Documents
An electronic ReactIR 45m Hardware Documentation Portfolio, shipped with the instrument,
includes the following documents in addition to this manual:
ReactIR Sampling Technology Guide (MK-PBG-0008-AC)
ReactIR Fiber Probe Care and Use Bulletin (MK-PB-0083-AC)
Quick Reference Guides:
Using a High-Pressure ReactIR Probe Adapter (MK-PB-0089-AC)
Connecting a DS Optical Interface Module (MK-PB-0051-AC)
Instrument Performance Assurance (IPA) for ReactIR Systems (MK-PB-0111-AC)
Reaction Analysis Performance Specifications (MK-RF-0016-AC)
Refer to the iC IR Documentation Portfolio for user guides and associated software
documents. The software portfolio is compiled in iC IR—select it from the Help menu.
Check the http://community.autochem.mt.com site for the latest portfolios.
Should you have questions that are not addressed in this documentation, please contact your
local METTLER TOLEDO office or our Customer Care Department using the information under
“Service and Technical Assistance” on page 9. I
f you are viewing this document electronically, click any blue-colored link to go to the related
information and instructions.
1. Introduction
MK-PB-0114-AC Rev A 8
METTLER TOLEDO
Symbols in this Manual
To help you recognize information, the following symbols appear throughout this manual.
Please pay particular attention to the sections marked by these symbols.
General Policies
METTLER TOLEDO equipment is subject to the installation, repair, and computer service
policies described below.
Installation Policy
Site preparation for the ReactIR 45m equipment is the user's responsibility. Structural
installation details should be prepared and supervised by a certified and registered
professional engineer who is properly qualified to assure a safe installation at your site.
Repair Policy
METTLER TOLEDO warrants its products against defects in materials and workmanship for
twelve months from the date of installation or fifteen months from the date of shipment. For
details, please refer to the warranty provided with the instrument. For assistance, please
contact your Technology and Applications Consultant (TAC) or send an email to
It is recommended that you retain the original packing materials in the event you need to
return the ReactIR 45m. If factory service is required, your METTLER TOLEDO service engineer
will issue you a Return Material Authorization (RMA) form.
Computer Service Policy
If a computer is included as part of your ReactIR 45m system, it will be from a major
manufacturer such as Dell. In the U.S. and some European countries, the manufacturer will
provide warranty service if required. METTLER TOLEDO can assist in diagnosing problems
with computers, but the computer manufacturer will provide parts and labor for repairs under
the service contract.
Table 1-1 Warnings, Cautions, and Notes
WARNING—Extremely important safety information—Failure to
observe the warning may result in serious personal injury or equipment
damage.
Caution—Important information that tells you how to prevent damage
to equipment or to avoid a situation that may cause minor injury.
Note: Information to which you should pay special attention.
9ReactIR™ 45m Hardware Manual
METTLER TOLEDO
Software Upgrades
When applicable, upgrades to the instrument and office software are available for iCare
subscribers. When a new release or service pack is available, all iCare subscribers with a
valid subscription will be notified via email so they can download the installer from the
AutoChem Customer Community website, [email protected]. Access to the
site requires a password that you can request from the home page. You can also contact
Customer Care or your METTLER TOLEDO Technology and Applications Consultant (TAC)
using the information on page 9.
Non-iCare subscribers can request a quote for an upgrade by contacting their local Account
Manager or Customer Care.
Training Programs
Training for ReactIR 45m systems is available from the AutoChem Customer Community
website (see link above) and through your METTLER TOLEDO TAC. Use the contact
information under "Service and Technical Assistance".
Service and Technical Assistance
METTLER TOLEDO has offices around the world. Contact the Mettler-Toledo AutoChem, Inc.
headquarters in the USA for technical support or service. To arrange for specific application
assistance from a METTLER TOLEDO Technology and Applications Consultant (TAC) or for
general assistance, contact Mettler-Toledo AutoChem, Inc. through the toll-free number below.
Mettler-Toledo AutoChem, Inc.
(Columbia, MD headquarters)
http://www.mt.com/ReactIR
http://www.mt.com/iCIR
Tel: + 1.410.910.8500
Fax: +1.410.910.8600
Email:
Toll Free: +1.866.333.6822
1. Introduction
MK-PB-0114-AC Rev A 10
METTLER TOLEDO
11ReactIR™ 45m Hardware Manual
METTLER TOLEDO
2
Pre-Installation Checklist
This chapter outlines the end-user’s responsibility to ensure a successful installation of the
ReactIR™ 45m system and provides information about physical and utility requirements. The
Field Service Engineer (FSE) responsible for performing system installation will send the link
to this document upon initial shipment of system to allow adequate time for site
preparation.The document is on the AutoChem Customer Community website.
Use this chapter of the document as a checklist to verify that all prerequisite steps have been
completed before a scheduled ReactIR 45m system installation. Items on this checklist must
be completed prior to scheduling a date for system installation with a METTLER TOLEDO Field
Service Engineer.
If you have any questions or need assistance please contact AutoChem Customer Care using
the information on page 9. Refer to Chapter 5 on page 29 for detailed system specifications.
[ ] Site Preparation
Complete the following sections to prepare your site for safe, fully functional use of the ReactIR
45m.
[ ] Space and Weight Requirements
A ReactIR 45m system can be installed on a bench top or inside a fume hood. Allow space
for the base unit with power supply as well as room to maneuver the sampling technology
for reaction analysis. Also, allow adequate space for the control computer.
*Overall system dimensions will vary depending on the selected sampling technology and
do not include the footprint of the control computer.
Note:
Access to the site requires a password that you can request from the home
page, https://community.autochem.mt.com. Setting up access during pre-
installation will facilitate software license activation, which is also done
through the AutoChem Customer Community site.
Table 2-1 Site Preparation—System Size and Weight
ReactIR 45m Dimensions* Weight
Base unit (H x W x D) 279 mm x 213 mm x 381 mm
[11 in x 8.4 in x 15 in]
(see drawing on page 15)
16 kg [35.3 lb]
Power supply 76 mm x 43 mm x 130 mm
[3.0 in x 1.7 in x 5.1 in]
0.55 kg [1.2 lb]
2. Pre-Installation Checklist
MK-PB-0114-AC Rev A 12
METTLER TOLEDO
[ ] Area of Intended Use
The area of intended use requires compliance with the following statements:
The ReactIR 45m system is designed for use in a non-hazardous area in accordance
with governmental bodies in the country of use (see Chapter 4, “Safety”).
System must have adequate benchtop space for conduit and probe
Fiber probe should not bend beyond 30 centimeters (approximately one foot).
Probe conduit should not be put into an “S” shape.
System should be:
Convenient for access at eye level
Readily accessible for service
If your Standard Operating Procedure (SOP) includes a fume hood, ensure it is installed
prior to the scheduled instrument installation.
The ReactIR 45m should not be placed directly under an air duct or vent which would
expose the system to direct airflow and extreme temperature ramps.
The ReactIR 45m should be placed in a location with minimal vibration present (that is,
no large pumps with heavy vibration on the same bench top).
[ ] Environmental Conditions
Exceeding the maximum allowable ambient temperature and humidity will negatively impact
the instrument performance and reaction monitoring data. For proper system stability and
functionality, adhere to the environmental specifications.
[ ] Utilities
ReactIR 45m systems require AC power, instrument air/gas, and communication utilities as
described below.
Note:
The ReactIR 45m base unit should not be placed directly under an air duct
or vent which would expose the system to direct airflow and extreme
temperature ramps. In addition, the ReactIR 45m should be placed in a
location with minimal vibration present (that is, no large pumps with heavy
vibration on the same bench top).
Table 2-2 Site Preparation—Environmental Conditions
Ambient Temperature (Maximum) 40 °C [104 °F]
Ambient Humidity < 60%
Operating Temperature Range 19 °C to 25 °C [66 °F to 77 °F]
13ReactIR™ 45m Hardware Manual
METTLER TOLEDO
Site Preparation—Electric
Verify that a power outlet is accessible in the area of intended use for the ReactIR 45m and
the control computer. Power specifications are as follows:
Site Preparation—Utilities (Air/Gas)
The ReactIR 45m base unit requires a purge. In addition, the ReactIR Fiber-to-Sentinel and
Mirror Conduit sampling technologies also require clean, dry, instrument quality air for purge.
Quality of the air or gas supply must meet the specifications of the American National
Standards Institute/Instrument Society of America (ANSI/ISA) S7.0.01-1996 Quality Standard
for Instrument Air.
Air/gas specifications are as follows:
Have a dew point at least 10 °C [18 °F] lower than the minimum temperature to which
any part of the system will be exposed.
Contain less than 1 ppm total oil or hydrocarbons.
Contain less than 1 ppm particulates at a maximum size of three (3) microns.
Be free of any corrosive contaminants and flammable or toxic hazardous gases.
Table 2-3 Site Preparation—Utilities (Electric)
AC Power 100–240 VAC ±7%
Maximum Current 2.0 A
Frequency 50/60 Hz
Power supply (provided) Rated DC input: ±12 VDC, 2.5 A and 13.6 VDC, 6 A
Mini Fuse: 5 A, fast acting, internal
BATTERY: CR-2032 3V manganese dioxide lithium coin
battery for real-time clock.
iC IR workstation PC See specific computer manual for voltages (dedicated circuit)
Note:
AC Line Conditioner—Power requirements do not include any additional
device. However, we recommend an AC line conditioner in areas where
power noise is known to exist. The line conditioner should have a power
rating of at least 800 VA.
Table 2-4 Site Preparation—Utilities (Air/Gas)
Pressure 0.69 bar [10 psi]
Flow Rate 4.7 LPM [10 SCFH]
Note:
Pressure and flow regulators are NOT supplied with the equipment and are
the end user’s responsibility.
2. Pre-Installation Checklist
MK-PB-0114-AC Rev A 14
METTLER TOLEDO
Site Preparation—Utilities (Communication)
The ReactIR 45m communicates to a control computer via USB cable (provided).
For additional specifications, refer to page 29.
[ ] Internal Paperwork and Approval for Installation
If applicable, complete any necessary internal paperwork and approvals required within your
organization for installation and start up of the ReactIR 45m system.
[ ] Standard and Optional Items
[ ] Computer Specifications
When a computer is ordered with the system, the iC IR software is preloaded. If you plan to
purchase a new computer or use an existing one, it must meet minimum specifications that
METTLER TOLEDO recommends in the computer specifications listed in the “iC Software
Computer Specifications Guide.” Access this guide from the METTLER TOLEDO website: http:/
/www.mt.com/iC.
Table 2-5 Site Preparation—Utilities (Communication)
Cable USB 2.0
Cable length 10 m [32.8 ft]
Notes:
Do not to exceed the 10 meter USB cable length as it could result in
intermittent communication issues.
Use of USB extenders is not recommended.
Table 2-6 Site Preparation—Standard and Optional Items
Item Standard Accessory / Option
Control Software—iC IR
Power Supply with country-specific AC power cable
USB cable
Funnel
Small flat-head screwdriver for gain adjustment
Choice of appropriate sampling technology
Stabilization Foot (for use with Mirror Conduit to provide stability)
Control computer (iC IR workstation PC)
Note:
Minimum specifications are listed in the “iC Software Computer
Specifications Guide” and also in the “iC IR Installation Guide.”
15ReactIR™ 45m Hardware Manual
METTLER TOLEDO
System Dimensions
The diagram in this section show the dimensions of the ReactIR 45m base unit. Allow
additional space for the sampling technology and control computer.
Figure 2-1 ReactIR 45m base unit
ReactIR
POWER
RTD 2
ACC
P1 P2
RTD 1
SCAN
MCT OK
TEMP OK
45m
45m
213 mm
[
8.4 in
]
381 mm
[
15 in
]
28 mm
[
1.1 in
]
28 mm
[
1.1 in
]
279 mm
[
11 in
]
2. Pre-Installation Checklist
MK-PB-0114-AC Rev A 16
METTLER TOLEDO
17ReactIR™ 45m Hardware Manual
METTLER TOLEDO
3
Product Description
This chapter describes the ReactIR™ 45m and the possible system configurations. A ReactIR
45m system consists of a base unit and sampling technology along with iC IR™ software.
Designed to be simple and easy to use, the system comes in the following overall
configurations that differ by the type of DS sampling technology:
"Overview of the ReactIR 45m System"
"ReactIR 45m System Diagram"
"ReactIR 45m Sampling Technology Configurations"
Overview of the ReactIR 45m System
ReactIR 45m is an FTIR-based, high performance, in situ reaction analysis system designed
specifically for the chemist and chemical engineer who require the highest level of precision
for kinetic studies and quantitative analysis. It provides real-time information on the effect of
changing reaction conditions such as solvent, catalyst, temperature, and reagent addition
rate, saving valuable resources. Based on the information provided by ReactIR 45m,
scientists are able to correlate, in real time, the impact of varying reaction conditions to
reaction performance—dramatically reducing development time.
Valuable characteristics of the ReactIR 45m system include:
Ergonomics—No obstruction to daily workflow, easy to monitor every reaction
Minimal purge—Improved data quality without external requirements/costs.
No alignment (FiberConduit only)—Highest quality data assurance without user input.
Minimal alignment in case of Mirror Conduits.
Plug-n-Play sampling—Reproducible measurements
Enhanced understanding of chemistry—Monitor reaction temperature simultaneously
with chemical changes
Standard items included with the ReactIR 45m base unit are:
24-hour cooling capacity, Mercury Cadmium Telluride (MCT) detecor
iC IR 4.3 or later software version
USB communications cable
Power Supply with country-specific power cord
Funnel, small flat-head screwdriver
Purge tubing and connectors
Not included but necessary for routine operation are,
Workstation—Laptop or Desktop
Note: Sensor sampling technology interfaces are sold separately.
3. Product Description
MK-PB-0114-AC Rev A 18
METTLER TOLEDO
Sampling Technology: DS AgX Fiber Probe, DS Micro Flow Cell, K4 MirrorConduit/
Sentinel, or K6 MirrorConduit/16 mm Probe, DS Fiber-to-Sentinel, DS Fiber-to-Gas Cell
(MTPN available upon request)
One Year System Warranty (includes standard sampling technologies) purchased with
system). System warranty ends one year after installation or fifteen months after
shipment. Refer to page 93 for detailed warranty packages.
A ReactIR 45m system uses METTLER TOLEDO proprietary software, iC IR, to assure infrared
data collection and analysis possible without the need for an expert. iC IR is the result of many
years of evolution through valuable customer feedback that offers powerful reaction analysis
functions with an easy-to-use user interface. As a wizard-based application, iC IR guides you
through the experience of collecting, analyzing, and visualizing data for real time insight into
your chemistry. In essence, iC IR allows chemists to focus on solving chemistry problems
instead of instrumentation and analysis procedures.
See Chapter 4, “Safety” for safety-related information.
Definition of Terms
Refer to Appendix B on page 103 for the terms used throughout this manual and in the control
software for a ReactIR 45m system.
ReactIR 45m System Diagram
The diagram below identifies the components necessary to build up a ReactIR 45m system,
essentially what hardware the customer purchases from METTLER TOLEDO according to
specifications to install and implement the system. Components include the base unit,
computer, communication cable, power cable, and sampling technology.
Figure 3-1 ReactIR 45m system diagram
Note:
This manual uses DS to refer to either DS or DST sampling technology.
DS is an abbreviation for D Sub-miniature, which describes the D-shaped
connector at the end of the sampling technology that connects to the
ReactIR 45m base unit. The DS or DST designation refers to the design
of the probe tip.
19ReactIR™ 45m Hardware Manual
METTLER TOLEDO
The Table 3-1 describes the internal components of a ReactIR 45m base unit: We include the
definitions for an understanding of the components that METTLER TOLEDO representatives
discuss with you during initial training, follow-up service or preventive maintenance. By
design, the ReactIR 45m will not require the user to know the location for alignment or
replacement of these components.
ReactIR 45m Sampling Technology Configurations
This section describes the sampling technology options available with ReactIR 45m.
"DS FiberConduit Probe"
"DS Micro Flow Cell"
"DS Fiber-to-Sentinel"
"DS Fiber-to-Gas Cell"
"K4 Mirror Conduit/Sentinel"
"K6 Mirror Conduit/16 mm Probe"
Please refer to the “ReactIR Sampling Technology Guide” for details on specific DS and
conduit technologies.
DS FiberConduit Probe
DS FiberConduit Probe systems are suitable for monitoring chemistry in a reaction vessel of
the customers' choice by insertion of the probe into the liquid-based reaction medium. This
ReactIR 45m configuration requires a DS Optical Interface Module (sold separately) in
addition to the DS FiberConduit probe. Temperature monitoring of the reaction mixture is
optional with a DS Optical Interface Module—RTD ready (sold separately).
Table 3-1 ReactIR 45m Internal Components
MCT Detector Senses the amount of infrared radiation after passing through a sample. Includes a
detector preamp. Requires liquid nitrogen in the dewar to be operational. (1 L
capacity)
Detector Preamp Electronic board that assists the detector in reaching maximum operating
performance. User adjustment may be necessary when changing sampling
technology, for example from DS FiberConduit Probe to DS Micro Flow Cell or K4/K6
Mirror Conduit.
IR Source Supplies the infrared radiation to the sample
Midget Modulator Mechanical device that affords full spectrum infrared measurements of high
sensitivity in a shorter period of time than traditional dispersive spectroscopy
methods. Also known as the interferometer or heart of the Fourier Transform Infrared
(FTIR) measurement. Produces source radiation specific to FTIR technology.
Interferometer Control
Board Module (ICBM)
Circuit board for controlling specific devices related to the interferometer
(modulator).
Power supplies Supplies electrical power to internal ReactIR 45m components.
Laser Class 1 InGa/AsP/InP laser diode that is an integral component of the modulator.
3. Product Description
MK-PB-0114-AC Rev A 20
METTLER TOLEDO
Figure 3-1 ReactIR 45m base unit with Single Optical Interface module (RTD option shown) for DS fiber
sampling technology
Optical Interface Modules
A single or multiple Optical Interface Module attaches to the SIM flange on the front of a the
ReactIR 45m base unit to connect to a DS fiber or DS Micro Flow Cell sampling technology.
Single Optical Interface
The figure below shows a Single Optical Interface
module with the optional Resistive Temperature
Device (RTD) cable.
Figure 3-2 Single Optical Interface Module (with RTD cable)
DS MultiplexIR
ReactIR 45m can control two DS FiberConduit
probes with the optional MultiplexIR Optical
Interface module. The module includes RTD
technology for monitoring reaction temperature at
each probe.
A MultiplexIR system monitors two different or
similar chemical reactions at the same time.
Figure 3-3 MultiplexIR for dual probe configuration
Figure 3-4 shows the MultiplexIR Optical Interface Module connected to the base unit with
two fiber probes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110

Mettler Toledo ReactIR 45m User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI