AquaTight MS300 Installation And Operating Instruction Manual

Category
Above ground pool accessories
Type
Installation And Operating Instruction Manual
USE ONLY AQUATIGHT GENUINE REPLACEMENT PARTS
MS300 Variable Speed Pump
30-LITINSB013 Rev-B
Secure pump to base
with screws or bolts to reduce vibration and pipe stress.
SELF-PRIMING SWIMMING POOL PUMP
INSTALLATION AND OPERATING
INSTRUCTION MANUAL
Your Aquatight variable speed self-priming centrifugal pump has been quality-built and
engineered to give you many years of efficient, dependable, corrosion
free service.
The advanced design reduces operation and maintenance to simple,
common-sense procedures.
MS300 Variable Speed Pump
USE ONLY AQUATIGHT GENUINE REPLACEMENT PARTS
MS300 Variable Speed Pump
MS300 Variable Speed Pump
Replacement Parts
Parts Diagram
Parts Listing
Ref. No.
1
2
3
4
5
6
--
7
8
9
10
11
12
13
14
--
15
16
17
18
--
--
--
Description
Pump Housing/Strainer - 50mm, w/Drain Plugs, threaded style
Basket
Strainer Cover O-Ring
Strainer Cover, Hand-Knob Style, Clear
Housing Gasket
Diffuser
Diffuser Gasket - Not Shown
Impeller Ring
Impeller
Seal Assembly
Seal Plate
Motor Cap Screw
Slinger
Motor Mounting Plate
Housing Cap Screw
Washer, 3/8” for Housing Cap Screw - Not Shown
Motor
Mounting Bracket with Adaptor and 2 Cap Screws
Mounting Foot Cap Screws (Set of 2)
1/4” Drain Plug with Gasket
Hand Knob Kit for Strainer Cover (Includes Hand Knob and Swivel Nut)
Union Kit (2) 40mm - 50mm - Super II pump - Not Shown
Union Gasket (T-Seal)
3
4
1
2
18
5
6
7
8
9
10
11
12
13
14
15
16
17
a
b
c
Qty. Req’d
1
1
1
1
1
1
1
1
1
1
1
4
1
1
6
6
1
1
1
2
2
1
2
USE ONLY AQUATIGHT GENUINE REPLACEMENT PARTS
MS300 Variable Speed Pump
Benefits of operating at low speeds
• Save electricity and money. A reduction in Pump Speed of 50% will reduce power consumption by up to 75%
• Better filtration - the filter can often remove smaller particles when the water moves slower
• Quiet operation, so therefore it is very unlikely to be intrusive to your neighbours
• Reduced Total Dynamic Head - less stress on equipment (e.g. filter) which can extend equipment life
When determining the speed(s) to operate your pump, you must also take into account the minimum requirements for
proper sanitation and equipment/water feature functionality.
It is recomended you filter (”turnover”) all the water in the pool at least once every 24 hours. Check with local
requirements for the minimum turnover rate. Running the pump at lower speed may require running the pump for a
longer period of time in order to meet the turnover requirements for proper sanitation.
Equipment such as heaters, skimmers, and chlorinators require minimum flows to operate correctly. Refer to the
individual equipment manuals for specific requirements for low flow operation.
After setting the pump speed(s), it is recommended you check all other equipment/water features are functioning as
intended. For example, when running at low speed for daily filtration, verify that the water is adequately flowing over the
skimmer weirs. Operate the pump at higher speeds for the shorter periods of time needed to operate a heater, water
feature, times of increased bather load, ect.
Filter (LOW Speed) - This speed will meet the daily requirements for most private use pools up to 50,000 litres
depending on the speed it is adjusted too, and will turnover the entire pool volume in an average
8 to 10 hours of operation. The factory default setting of this speed is used to obtain the seven
star energy rating and is the recommended minimum speed for filtration.
Boost (MED Speed) - This speed can be adjusted to increase the flow for the operation of pool accessories or at times of
heavy bather load.
Turbo (HIGH Speed) - Use this speed for backwashing and operation of accessories that may require extra flow for
for specific functions, such as Spa Jets and Water Features.
MS300 Variable Speed Pump
Motor Operation:
1. Power Up
- Via supply cord
- Power LED on / Error LED one or two flashes
- Ramp up (after 5 second delay)
2. Priming Cycle
- Starts on HIGH speed
- Cycle runs for 2 minutes
3. Normal Operation
- Resumes previously selected speed prior to shut down
- LED solidly lit indicating currently selected speed
4. Speed Selection
- Via touch pad on motor interface. One second delay after switching
- Ramp up or down will take 2 - 5 seconds depending on the speed
- LED solidly lit on the newly selected speed
5. Shut Down
- Via power out let that the supply cord is connected to
- Via the STOP button on the motor interface touch pad
6. Fault Mode
- Motor will not start
- Error LED flashes a sequence followed by a pause
- Sequence is repeated (record number of flashes in the sequence and contact your service agent)
7. Over Temperature Mode
- The pump speed is reduced until a steady state temperature is maintained with in the maximum limit
8. Overload Protection Mode
- Speed is reduced until steady state full load current is maintained within the maximum limit
USE ONLY AQUATIGHT GENUINE REPLACEMENT PARTS
MS300 Variable Speed Pump
MS300 Variable Speed Pump
MOTOR INTERFACE USER GUIDE
Normal Operation Mode:
Press Button:
- For Low Speed
(LED will remain solidly lit when selected)
- For Medium Speed
(LED will remain solidly lit when selected)
- For High Speed
(LED will remain solidly lit when selected)
- Stop Button
(Power LED will flash when the pump is in standby mode)
Adjusting The Set Point Of Each Speed:
Press and hold
, , or for aproximatly three (3) seconds or untill the LED of the selected speed
begins to flash. Once flashing the selected speed has entered into the Adjustable Set Point Mode.
To reset the speeds to the factory default settings hold down all three (3) buttons untill all three LED’s are solidly lit.
Press Button:
- To decrease speed by 100rpm increments with 1000rpm as the minimum limit for LOW, MED, and HIGH.
- To save the current speed setting and return to Normal Operation Mode hold the button down for 5 seconds.
- To increase speed by 100rpm increments with 2850rpm as the maximum limit for LOW, MED, and HIGH.
- Will cancel the change and revert back to the original speed and return to Normal Operation Mode.
Note:
- If power is removed , motor will return to the last speed that was selected when power is restored.
- If power is removed then restored the motor will remember what it’s on/off state was.
- If there is a fault, the fault LED will blink a sequence code. Count the blinks and contact service agent.
Autopool warrants that its product is free from defects in materials and manufacture and is covered by a limited 5 Year
Warranty. Wet End is covered for a period of five years (3 years full warranty plus 2 years Pro Rata) and motor is
covered for 3 years full warranty against defects in materials and workmanship from the date of purchase
(plus 30 days to allow for installation). Autopool will at its discretion, except in the circumstances described below,
either replace or repair any product proven to be defective during the warranty period for either materials or
manufacture with in 90 days of the receipt of the defective product, barring unforeseen delays. This warranty is
personal to the original purchaser and does not pass to any subsequent purchaser(s).
To the extent permitted by law, Autopool will not be liable for products which fail or become defective during the
warranty period as a result of freezing, accident, negligence, improper installation, incorrect power supply and/or
connection, use in non swimming pool or spa application, improper chemical balance in the water, running the pump
dry, addition of salt and pool chemicals through the skimmer, any foreign object or material blocking the impeller, and
misuse or lack of care. This warranty does not extend to:
(a) normal wear and tear;
(b) weather and other environmental conditions including but not limited to storm, flood, and/or heat wave damage; or
(c) service and maintenance items such as (but not limited to), Union and strainer cover gaskets / o-rings, Mechanical
seal, and strainer basket.
To the extent permitted by law, except as set out in this Warranty, Autopool excludes all statutory or implied conditions
and warranties and any other liability it may have to the Customer (including liability for indirect or consequential loss)
that may arise under statute or at law including without limitation for breach of contract, in tort (including negligence)
or under any other cause of action.
To the extent permitted by law, except as set out in this Warranty, Autopool limits its liability under any condition or
warranty which cannot be legally excluded in relation to the supply of Goods and Services to:
(a) Replace or repair the Product or the defective part of the Product free of charge; or
(b) Cause the Product or the defective part of the Product to be repaired or replaced by an Authorised Autopool Service
Agent free of charge.
USE ONLY AQUATIGHT GENUINE REPLACEMENT PARTS
MS300 Variable Speed Pump
Warranty - Standard Conditions
Automated Pool Products Pty Ltd (ACN 008 816 596) (”Autopool”) distributes the Aquatight MS300 Variable Speed
Swimming Pool and Spa Pump in Australia and provides the following warranties:-
STATUTORY RIGHTS
1. The benefits to the consumer under this warranty are in addition to other rights and remedies of the consumer
under the laws in relation to the goods and services to which the warranty relates; and
2. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You may be entitled
to a replacement or refund for a major failure and for compensation for any other loss or damage. You are also entitled
to have the goods repaired if the goods fail to be of acceptable quality and failure does not amount to a major failure.
LIMITED WARRANTY
WARRANTY CLAIMS
To stand behind our commitment to provide warranty coverage, we have established a network of Autopool Authorised
Service Agents throughout Australia. To obtain warranty service, contact our Service Department at one of the contact
addresses listed in this manual or an Authorised Autopool Service Agent.
Any warranty claim must be accompanied by:
(a) proof of purchase;
(b) full details of the alleged defect; and
(c) appropriate documentation (historical and maintenance records)
If warranty inspection and testing finds no defect in the product, the customer must pay the costs of service work and
testing.
COMMERCIAL INSTALLATIONS
On Commercial Installations, such as health clubs, motels/hotels and hydrotherapy, warranty is 12 months from
the date of purchase plus 30 days.
Autopool assumes no liability for consequential damages of any kind.
MAXIMUM TOTAL HEAD - IMPORTANT INSTALLATION INFORMATION
F . If the Supply Cord is damaged, it must be replaced by
persons in order to avoid a hazard.
the manufacture, its service agent or similarly qualified
Model Max Total
Metres Head
Max Pressure
kPa
MS300 16.5 161
dischar
g
e
g
au
g
e readin
g
).
Aquatight
Aquatight
Aquati
ght
A
quatig
h
t
Th
e Pump Motor is an e
l
ectrica
l
d
evice an
d
as suc
h
s
h
ou
ld
not
b
e
d
issassem
bl
e
d
or service
d
by
anyone other than an authorised Aquatight Service Technician or quali
ed Electrical Servic
e
Company. An experience
d
Poo
l
Service Tec
h
nician s
h
ou
ld
atten
d
to any ot
h
er pro
bl
em
s
t
h
at cannot
b
e correcte
d
b
y routine maintenance
.
www.autopool.com.au
Aquatight
Perth
4/115 Belmont Avenue, Belmont, WA 6104
Phone: 08 9362 4022
Fax: 08 9361 3913
Sydney
Phone: 1300 656 956
Fax: 1300 656 356
Melbourne
Phone: 1300 656 956
Fax: 1300 656 356
Brisbane
Unit 2/ 264 Evans Road, Salisbury, QLD 4071
Phone: 07 3277 4958
Fax: 07 3272 9091
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

AquaTight MS300 Installation And Operating Instruction Manual

Category
Above ground pool accessories
Type
Installation And Operating Instruction Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI