Coxo C-SMART Usage Manual

Type
Usage Manual
*Thanks for applying the endodontic treatment instrument. For
the sake of safety and efficient use of the product, please read this manual first.
C-SMART
C-SMART
ENDODONTIC TREATMENT INSTRUMENT
Usage manual
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
0482
Content
Safety caution
Intended use and features
Standard accessory
Structure and function
Installation
Use method
Maintenance and sterilization
Troubleshooting
Service & Guarantee
Specifications
Transportation and storage
Mark illustration
Safety caution
Before use, please read the security instruction carefully
for which is able to facilitate the users to make good use of
this instrument.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
This unit must be used as the user's guide mentions, not for other purp-
se. Please refer to the usage instruction strictly. We won't take the re-
onsibility for the damage caused by improper use.
Before using the main power, make sure the power voltage is according
with the adaptor voltage range. Improper input voltage will damage the
unit and cause danger to the operator or the patient.
Do not drag the wire which connects to the endo motor emphatically. Or
it would be broke or be loosened and then affect the natural use.
Please use the original accessories, such as: endo motor, adaptor,and
battery We won t take the responsibility to any problem or dama-
ge caused by using other parts which are not supplied by us.
To avoid electric shock, don't insert any other parts into the unit it may
cause electric shock or damage.
Avoid the detergent go into the unit, in case that causes the short circuit
or problem.
Please turn off the instrument at once when something wrong with it.
It's not allowed to modify the unit at any condition. Any disassembling or
modification will cause the invalidation of the guarantee.
Please use the intact standard file. Or it would cause damage to the p-
tient while working.
The instrument has an electromagnetism disturbance. When there is a
patient who is using the cardiac pacemaker, or there is an electronic op-
eration, please don't put the machine around.
Unstable voltage and if it's in electromagnetic environment will inte-
rfere the normal operation.
When discard the accessories, please abide with the local regulation, if
necessary, contact our service center to recover it.
This unit just for the user of professionals.
o
sp
a
.'
;
1
2
1pcs
1pcs
1pcs
1pcs
1pcs
1pcs
1pcs
1pcs
Intended use and features
C-Smart is the supplementary root-canal treatment device
which can assist the dentists to shape more standard root-canal
in the process of root-canal treatment .
The features are as follows:
9 settings for adjustable rotational speed ranging from 125 to
Drive-1:1 contra angle is available.
The torque exceeds the regulated value the file will reve
avoid the break off
Easy operating with LCD screen–what you see, what you get.
High capacity Li-ion chargeable battery and can work with bat
adaptor
Auto power off and memory function.
.
.;
-.
.
.
.
.
1 625rpm.
rse to
tery or
2
3
4
5
6
.
Standard accessory
1 Main unit
2 Adaptor
3 Motor handle
4 Contra angle(CX235-1)
5 Foot switch
6 Handle base
7. Usage manual
8. Torque setting card
.
.
.
.
.
.
3
Structure and function
②.foot switch jack
③.endo motor jack
④. power on/off button
Parts:
Contra angle(CX235-1)
Foot switch
Motor handle
Adaptor
Handle base
①.adaptor jack
⑤.auto reverse mode button
⑥.reverse button
⑦.speed adjust button
⑧.torque adjust button
F
R
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
LCD display description:
③“,
Rotation direction sign: display for forward and for reverse
Beeper sign
Auto reverse mode: when press button
unit enter this mode,
FR
AUTO REV
AUTO REV
file can forward and reverse automatically refer
on the torque. Press button again unit will exit this
mode.
“” ,
4
forward
reverse
④:
⑥: ;
“”
⑦: ;
“”
Torque display display the current torque
Gear display
Torque display the limit torque dentist can adjust torque by press
or button
Speed display the current speed dentist can adjust speed by
press or button
Battery power sign
TORQUE+ TORQUE-
SPEED+ SPEED-
TORQUE
Ncm
625
SPEED
min
-1
0.0
625
16:1
GEAR
SPEED
TORQUE
min
-1
Ncm
F
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
the mode“”AUTO REV exit the mode“”AUTO REV
press
press
5
6
2.
.
Insert the foot switch plug
into the jack on the main
unit
1.
.
Please put the instrument on
a solid place
3.
,
Connect the plug of the mot-
or wire to the main unit m-
ake sure that they are in the
right position.
4. Connect the 1:1 contra a-
ngle to the motor and cla-
mp the file into the contra
angle
Installation
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
speed range: 125 175 250 300 375
425 500 550 625rpm
、、、、、
、、
press
Use method
Endodontic treatment
1.
2.
“”
“”
. : 、、、、、
、、
Press button, unit enter idle status.
You can select proper speed based on different need: press
or button The speed range 125 175 250 300 375
25 500 550 625rpm
POWER
SPEED+
SPEED-
4
7
5. And then put the well conn-
ected main unit on the handle
holder reposefully.
6. Insert the adaptor plug into
the jack on the main unit
rotate clockwise
stamp
press
F
rotate
clockwise
R
rotate
anticlockwise
3.
4.
5.
:,
:..
“”,
-
You can adjust torque press the
torque range 36912151821253035404552mNm
When foot switch is stampeded, file will rotate clockwise according to
the speed has been set.
When file is clockwise rotation, press button file will
rotate counter clockwise immediately, press the button repeat, file will
change direction.
TORQUE+ & TORQUE-
REVERSE
、、、、、、、、、、
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
press
torque rang :3-52mNm
8
F
R
F
indicate the torque
exceed the setting torque
indicate the torque
disappear
beep
Press button will displayed on
LCD ,and it means unit enters auto reverse mode, at this status file will
reverse to advoid the break-off when the torque exceed the regulated
values and will rotate forward when the torque is disappeared .when
the file reverses, the beeper will emit a prompt sound.
Release the foot switch, file will stop working.
Press the POWER button, the unit will shutdown no matter in what modes.
You can adjust speed by press or
button when endo motor is working
6.
7.
8.
“”
.
“”,
SPEED+ SPEED-
AUTO REV AUTO REVERSE
stop rotate
x
stamp
9
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
R
0.0
625
16:1
AUTO
REVERSE
AUTO
REVERSE
GEAR
SPEED
TORQUE
min
-1
Ncm
F
the mode“”AUTO REV
10
Power manage
1. Battery power
2. Battery recharging
Notice: when the instrument is connected to the adaptor,
the beeper will beep for three times, showing the connect-
ion is correct.
3. Supply by main power
4 Automatic power off
Notice: When power off, the LCD will show recharging sign
when charging
.
LCD displays the current battery power, the number of lattice shows more,
and the power is fuller. If there is no electricity the lattice will flicker which
means the battery power is about to run out , at this status the beeper will
ring per 3S and unit will shut down after 60S
To fully recharge the battery, you should connect the unit to adaptor at
least for 4 hours or more The new battery requires at least 8 hours or
more), the sign will be running during the battery charging
Please connect instrument to adaptor when the battery power is not en-
ough. When the connection is completely, the instrument will be supplied by
the main power and charging the battery automatically
The instrument will shut down automatically when it ceases working for
3 minutes. In that case all display and function will stop.
,.
(
.
.
,
Short
using time
of the
battery
The battery is not
charge enough
Battery ageing
Try to charge the battery long up
to 4 hours each time
Change the battery or use the
main power
File not
auto reverse
Not turn into the
auto reverse mode
Press the
button
“”
.
AUTO REV
Reverse
continually
The resistance of
the root-canal in too
heavy
Change the mode to un-auto
reverse mode
Trouble
Can not
turn on
File not
work
Reason
Lack of power
Foot switch bad
contact
Over torque
Settle methods
Charge the battery or use the
main power
Contact the wire and make sure
the foot switch can work smoothly
Troubleshooting
11
exit the auto reverse mode
by pressing the
button and reverse manually
“”
.
AUTO REV
move the n and store it somewhere
dry and clean
should
be disinfected
dinfected by the
ethanol
.
.
Maintenance and Sterilization
1.
2.
3
,
,
.
.
If not use for long time please open the battery cover open and re-
battery keep the instrument clea
Parts like contra angle which have direct contact with the patient
by autoclave each time after used
The crust of the instrument and the wire should be
If the equipment is not normal work, before call our after-sales center,
please check the table below.
Service & Guarantee
Specifications:
Our company is responsible for product-and-technology service.
technical section will offer you technical instruction when tech
occur.
The C-smart main unit is guaranteed for 24 months from the date of
purchase, and the adaptor, foot switch, contra angle, motor handle, battery
are guaranteed for 6 months. The handle base is not covered by warranty.
The guarantee is valid for normal usage conditions. Any modification or
accidental damage will render the guarantee void.
We will repair or replace, at its option, a defective unit. This warranty is
in lieu of all warranties of merchantability, fitness for purpose or other
warranties express or implied. We do not accept liability for any loss or
damage, direct, consequential or otherwise, arising out of the use of or the
inability to use the product herein described.
Adaptor: Input AC 100-240V 50/60HZ
Output DC V 1.5A
Battery Chargeable Li-on battery 7.4v / 1000mAh
Power: 5W
Speed: 125-625 rpm
Torque: 3 52 mN.m)
Current: mA
Display: Reflecting LCD screen
Guarantee
:
Service for product
Our
nical problem
10
0.3-5.2 N.cm ( -
<500
Protection against electrical shock: type B
12
13
Transportation and storage
Mark illustration
Ambient temperature: +5 ~+40
Relative humidity range: 10%~93%
Atmospheric pressure: 86Kpa~106Kpa
Equipment is not suitable for storage in the presence of sunlight,
rain,dust, and corrosive gasoline and volatile with poor ventilation.
Transportation is applicable to all common methods.
℃℃
IPX1
Direct current
Class equipment (adaptor)
Type B equipment
Caution! Please read the instruction
WEEE
Protection against ingress of liquids: drip-proof footswitch
CE marked product
()
Ver 5.0
Foshan COXO Medical Instrument Co. Ltd
Address: 21 Wufeng Si Road, Foshan, Guangdong China
,
Wellkang Ltd.
Address: Suite B, 29 Harley Street London W1G QR
United Kingdom
,,9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Coxo C-SMART Usage Manual

Type
Usage Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI