Component Testing Information
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
RT2310011 Rev. 0 September 19992
Illustration Component Test Procedure Results
0316385 Oven light socket Remove one wire from receptacle and
test resistance of terminals.
Measure voltage at oven light.
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light,
check wiring or light switches.
0316160 Rocker switch Measure continuity of switch positions:
Closed
Open
Continuity, if not replace.
Infinite, if not replace.
31827601 Gas valve Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
NOTE:
There are no field adjustments
on the safety valve.
Allow 60 seconds for gas valve to open.
Continuity, If not replace.
Continuity, If not replace.
WARNING
Do not attempt to open valve with
120 VAC.
31829701 Pressure regulator Verify gas pressure (WCP).
If on LP service, verify proper gas
supply conversion.
5
Natural
10 LP/propane−14 maximum supply
NOTE: There are no field adjustments.
31829001 Oven thermostat Verify selector cartridge is set to the
proper gas (LP or Natural).
Set to higher than actual temperature.
Heater pilot will envelope temperature
responsive element and burner will light
within 60 seconds.
31837802
90° valve
Verify gas is supplied.
Orifice adjusted for Natural or LP.
Clean flame at burner.
31837701
Spark 90° switch
Test for voltage at terminals.
Disconnect wiring and check for
continuity in LITE position.
120 VACin LITE position
Continuity in LITE position.
31837601 Thermostat switch /
valve switch
Disconnect switch leads.
Attach meter leads to switch.
Measure for resistance.
Switch in LITE position.
Switch in any position except
LITE position
Continuity
Infinite
0315768 Top surface burner Verify gas is supplied.
Verify burner cap is positioned
correctly.
Check for obstructions in burner ports.
Check air shutter and LP conversion.
Clean flame not blowing or soft / lazy.