RectorSeal 84005 Operating instructions

Type
Operating instructions

This manual is also suitable for

Typical lineset* capacity 92mm 3
1
/2
W x 2
1
/2
D 122mm 4
1
/2
W x 3
1
/4
D
92mm w/Single 1
1
/8 Lineset
BTU - 60,000
Suction Line - 1
1
/8OD
(Insulation) - 1/2”
Liquid Line - 1/2”OD
Drain Line- 3/4”PVC
122mm w/Dual 3/4 Lineset
BTU - 36,000
Suction Lines - 3/4”OD
(Insulation) - 1/2”
Liquid Lines - 3/8”OD
Drain Line- 3/4”PVC
92mm w/Dual 3/4 Lineset
BTU - 36,000
Suction Lines - 3/4”OD
(Insulation) - 3/8”
Liquid Lines - 3/8”OD
Drain Line- 3/4”PVC
92mm w/Single 3/4 Lineset
BTU - 42,000
Suction Line - 3/4”OD
(Insulation ) - 1/2”
Liquid Line - 3/8”OD
(Insulation ) - 1/2”
Drain Hose - 7/8” OD
122mm w/Single 1
1
/8 Lineset
BTU - 60,000
Suction Line - 1
1
/8 OD
(Insulation) - 1”
Liquid Line - 1/2”OD
Drain Line- 3/4”PVC
122mm w/Dual 3/4 Lineset
BTU - 42,000
Suction Lines - 3/4”OD
(Insulation ) - 1/2”
Liquid Lines - 3/8”OD
(Insulation ) - 1/2”
Drain Hose - 7/8” OD
(1) Determine the path which the line-
set will follow and strike a chalk line to
mark the surface material. Attach the
base only of all ttings rst (ducting
will be placed last), along the marked
path, using fasteners of sufcient
length (not provided). Predrill where
necessary. Duct must terminate
with a tting to prevent cover
from sliding out of position.
Installation instructions
(2) Once all tting bases are
secured to the siding, measure
and cut ducting to t as needed.
Remember to account for some
seasonal expansion and contrac-
tion. Install and fasten ducting
bases. Attach bases only to
structure through provided punch
outs using fasteners of sufcient
length (not provided).
(4) Run lineset, drainhose,
wiring etc. over the tting
and duct bases and secure
to duct clips using tie wraps
of sufcient size.
(3) Position and twist in
lineset duct clips evenly
spaced throughout installation.
Nylon cable ties (not included)
slip through lineset duct clips
and fasten around lineset.
(5) Snap straight duct top over
mating straight base pieces. Seat
tting tops over mating tting bases
and secure with provided stain-
less screws. Duct must terminate
with a tting to prevent cover from
sliding out of position. If duct is
painted, or run horizontally,
adhere cover to base with
pvc cement.
963080
* Lineset size may change on Seer Rating
RectorSeal® 2601 Spenwick Drive - Houston, TX 77055 ph: 713.263.8001 - 800.231.3345 fax: 713.263.7577 - 800.441.0051
www.rectorseal.com - Like Us on Facebook
Fitting List Available in WHITE, IVORY, BROWN and GRAY. Sizes 3 1/2” (92mm) or 4 1/2” (122mm).
Flexible tting End tting Wall Sleeve
End tting provides criti-
cal support to the lineset
duct cover. Without this
tting, the duct cover can
slide out of place.
To adjust the opening to
suit lineset size, simply
snip the end tting along
the desired groove, and
break off unwanted
sections.
A coupling can also be
utilized at the duct end
for larger lineset ll.
(1) Using a hole saw, drill a hole at the desired
point of penetration. (2) Secure base over hole.
(3) Insert sleeve into hole. (4) Install lineset.
(5) Seal and attach cover.
HOLE
INLINE COUPLING
(1) Secure tting and duct
bases to wall. (2) Cut ex duct
to length and place in tting.
(3) Secure ex duct with split
cap and two screws.
(4) Secure duct into coupler
by tting second part of cap.
WALL CONNECTION
(1) Seal and attach wall ange
to wall. (2) Place ex duct into
coupler. (3) Clamp ex duct
with cap and two screws.
Specialty tting installation instructions
RIBS
RIBS
GROOVES
COVER
BASE
SLEEVE
3
1
/4 or 4
1
/4 O.D.
Ducting (8ft lengths)
Coupler
Wall Inlet
Soft Inlet
End Fitting
90° Flat Ell
45° Flat Ell
90° Inside Vertical Ell
90° Outside Vertical Ell
45° Inside Vertical Ell
45° Outside Vertical Ell
Tee
Reducer
90° Sweep Ell
Flexible Ell
Flexible Adaptor
Flexible Wall Flange
Wall Sleeve
Twistlock Lineset clips
LIMITED WARRANTY: Rectorseal® makes the Limited Express Warranty that when the instructions for storage and handling of our products are followed we warrant our products to be free from defects. THIS LIMITED EXPRESS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER OBLIGATION OF THE PART OF RECTORSEAL®. The sole remedy for breach of the Limited Express Warranty shall be the refund of the purchase price. All other liability is negated and
disclaimed, and Rectorseal® shall not be liable for incidental or consequential damages.
FLEX
DUCT
FLEX
DUCT
COUPLER
COUPLER
END FITTING
  • Page 1 1
  • Page 2 2