Microlife BP W3 Comfort User manual

Category
Blood pressure units
Type
User manual

Microlife BP W3 Comfort is an easy-to-use wrist blood pressure monitor that provides accurate and reliable measurements. It features a cuff fit check indicator to ensure proper placement, and an arrhythmia indicator to detect irregular heartbeats. The device stores up to 30 measurements, and calculates the average of all stored values. It also comes with a large, easy-to-read display and a low battery indicator.

Microlife BP W3 Comfort is an easy-to-use wrist blood pressure monitor that provides accurate and reliable measurements. It features a cuff fit check indicator to ensure proper placement, and an arrhythmia indicator to detect irregular heartbeats. The device stores up to 30 measurements, and calculates the average of all stored values. It also comes with a large, easy-to-read display and a low battery indicator.

IB BP W3 Comfort EN-RU 2019
BP
Wrist Blood Pressure Monitor
EN
W3 Comfort
1
Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
www.microlife.com
ONBO Electonic (Shenzhen) Co., Ltd., No.
497, Ta Laneg Nan Road, Ta Laneg Street,
Baoan District, Shenzhen, China.
Π‘Π΄Π΅Π»Π°Π½ΠΎ Π² ΠšΠΈΡ‚Π°Π΅
RU 9
Microlife BP W3 Comfort
7
8
9
AT
AK
AL
AM
AN
AO
AO-A
AO-B
AO-C
AQ
AP
1
3
5
6
4
2
BP W3 ComfortGuarantee Card
Name of Purchaser / Π€.И.О. покупатСля
Serial Number / Π‘Π΅Ρ€ΠΈΠΉΠ½Ρ‹ΠΉ Π½ΠΎΠΌΠ΅Ρ€
Date of Purchase / Π”Π°Ρ‚Π° ΠΏΠΎΠΊΡƒΠΏΠΊΠΈ
Specialist Dealer / Π‘ΠΏΠ΅Ρ†ΠΈΠ°Π»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹ΠΉ
Π΄ΠΈΠ»Π΅Ρ€
1BP W3 Comfort
EN
Display
Read the instructions carefully before using this device.
Type BF applied part
Intended use:
This oscillometric blood pressure monitor is intended for measuring
non-invasive blood pressure in people aged 12 years or older.
Dear Customer,
This device was developed in collaboration with physicians and clinical tests
carried out prove its measurement accuracy to be of a very high standard.*
If you have any questions, problems or want to order spare parts please
contact your local Microlife-Customer Service. Your dealer or pharmacy
will be able to give you the address of the Microlife dealer in your country.
Alternatively, visit the internet at www.microlife.com where you will find a
wealth of invaluable information on our products.
Stay healthy – Microlife AG!
Microlife BP W3 Comfort
EN
1
ON/OFF button
2
Display
3
M-button (memory)
4
Time Button
5
Battery Compartment
6
Cuff
7
Systolic Value
8
Diastolic Value
9
Pulse Rate
AT
Date/Time
AK
Stored Value
AL
Traffic Light Indicator
AM
Pulse Arrhythmia Indicator (PAD)
AN
Cuff Signal Indicator Β«ERR 1Β»
AO
Cuff Fit Check
-A: Suboptimal Cuff Fit
-B: Arm Movement Indicator Β«ERR 2Β»
-C: Cuff Pressure Check Β«ERR 3Β»
AP
Pulse Indicator
AQ
Battery Display
Keep dry
2
* This device is tested according to the
ESH
protocol and
ISO81060-2:2013
.
Table of Contents
1. Using the Device for the First Time
β€’ Inserting the batteries
β€’ Setting the date and time
2. Checklist for Taking a Reliable Measurement
3. Taking a Blood Pressure Measurement
β€’ How not to store a reading
β€’ How do I evaluate my blood pressure?
β€’ Appearance of the Pulse Arrhythmia (PAD)
F How not to store a reading
F How do I evaluate my blood pressure?
F Appearance of the Pulse Arrhythmia (PAD)
4. Data Memory
β€’ Viewing the stored values
β€’ Memory full
β€’ Clearing all values
5. Battery Indicator and Battery change
β€’ Low battery
β€’ Flat battery – replacement
β€’ Which batteries and which procedure?
β€’ Using rechargeable batteries
6. Error Messages
7. Safety, Care, Accuracy Test and Disposal
β€’ Safety and protection
β€’Device care
β€’ Cleaning the cuff
β€’ Accuracy test
β€’Disposal
8. Guarantee
9. Technical Specifications
Guarantee Card (see Back Cover)
1. Using the Device for the First Time
Inserting the batteries
After you have unpacked your device, first insert the batteries. The
battery compartment
5
is on the bottom of the device. Insert the
batteries (
2
x 1.5 V, size
AAA
), thereby observing the indicated polarity.
Setting the date and time
1. After the new batteries are fitted, the year number flashes in the
display. You can set the year by pressing the M-button 3. To
confirm and then set the month, press the time button 4.
2. Press the M-button to set the month. Press the time button to
confirm and then set the day.
3BP W3 Comfort
EN
3. Follow the instructions above to set the day, hour and minutes.
4. Once you have set the minutes and pressed the time button, the
date and time are set and the time is displayed.
5. If you want to change the date and time, press and hold the time
button down for approx. 3 seconds until the year number starts to
flash. Now you can enter the new values as described above.
2. Checklist for Taking a Reliable Measurement
1.
Avoid activity, eating or smoking immediately before the measurement.
2. Sit down on a back-supported chair and relax for 5 minutes. Keep
the feet flat on the floor and do not cross your legs.
3. Always measure in a sitting position and on the same wrist. Use
the wrist which usually shows higher blood pressure values.
4. Remove any items of clothing and your watch, for example, so
that your wrist is free.
5. Always ensure that the cuff is positioned correctly, as shown in the
pictures illustrated on the short instruction card.
6. Fit the cuff comfortably but not too tight. The cuff will cover a wrist
circumference of 13.5 - 23 cm (5.25 - 9.05 inches).
7. Support your arm in a relaxed position and ensure that the device
is at the same height as your heart.
3. Taking a Blood Pressure Measurement
1. Press the ON/OFF button 1 to start the measurement.
2. The cuff fit check AO on the display indicates that the cuff is
perfectly placed. If the icon AO-A appears, the cuff is fitted subop-
timally, but it is still ok to measure.
3. The cuff will now pump up automatically. Relax, do not move and
do not tense your arm muscles until the measurement result is
displayed. Breathe normally and do not talk.
4. The measurement is performed during the inflation. The inflation
speed may vary, this is a normal occurence.
5. During the measurement, the pulse indicator
AP
flashes in the display.
6. The result, comprising the systolic 7 and the diastolic 8 blood
pressure and the pulse rate 9 is displayed. Note also the expla-
nations on further display symbols in this booklet.
7. Remove and switch off the monitor and enter the result in the
enclosed blood pressure pass. (The monitor does switch off auto-
matically after approx. 1 min.).

You can stop the measurement at any time by pressing the
ON/OFF button (e.g. if you feel uneasy or an unpleasant pres-
sure sensation).
How not to store a reading
As soon as the reading is displayed press and hold the ON/OFF
button 1 until Β«MΒ» AK is flashing. Confirm to delete the reading by
pressing the time button AK.

Β«CLΒ» is displayed when the reading is deleted from the
memory successfully.
4
How do I evaluate my blood pressure?
The triangle on the left-hand edge of the display
AL
points at the range
within which the measured blood pressure value lies. The value is either
within the optimum (white), elevated (hatched gray) or high (black)
range. The classification corresponds to the following ranges defined by
international guidelines (ESH, ESC, JSH). Data in mmHg.
The higher value is the one that determines the evaluation. Example:
a blood pressure value of 140/80 mmHg or a value of 130/90 mmHg
indicates Β«blood pressure too highΒ».
Appearance of the Pulse Arrhythmia (PAD)
This symbol AM indicates that certain pulse irregularities were
detected during the measurement. In this case, the result may
deviate from your normal blood pressure – repeat the measurement.
In most cases, this is no cause for concern. However, if the symbol
appears on a regular basis (e.g. several times a week with measure-
ments taken daily) we advise you to tell your doctor. Please show
your doctor the following explanation:
4. Data Memory
This device automatically stores the last 30 measurement values.
Viewing the stored values
Press the M-button 3 briefly, when the device is switched off. The
display first shows Β«MΒ» AK and Β«AΒ», which stands for the average of
all stored values.
Pressing the M-button again displays the previous value. Pressing the M-
button repeatedly enables you to move from one stored value to another.

Blood pressure readings with suboptimal cuff fit AO-A are not
considered in the average value.
Range Systolic Diastolic Recommendation
1. blood pressure
too high
β‰₯135 β‰₯85 Seek medical
advice
2. blood pressure
elevated
130 - 134 80 - 84 Self-check
3. blood pressure
normal
<130 <80 Self-check
Information for the doctor on frequent appearance of the
Arrhythmia indicator
This device is an oscillometric blood pressure monitor that also
analyses pulse irregularity during measurement. The device is
clinically tested.
The arrhythmia symbol is displayed after the measurement, if
pulse irregularities occur during measurement. If the symbol
appears more frequently (e.g. several times per week on
measurements performed daily) we recommend the patient to
seek medical advice.
This device does not replace a cardiac examination, but serves
to detect pulse irregularities at an early stage.
5BP W3 Comfort
EN
Memory full

Pay attention that the maximum memory capacity of
30
memo-
ries is not exceeded.
When the
30
memory is full, the oldest
value is automatically overwritten with the
31st
value.
Values should be evaluated by a doctor before the memory
capacity is reached – otherwise data will be lost.
Clearing all values
If you are sure that you want to permanently remove all stored
values, hold down the M-button (the device must have been switched
off beforehand) until Β«CL ALLΒ» appears and then release the button.
To permanently clear the memory, press the time button while Β«CL
ALLΒ» is flashing. Individual values cannot be cleared.

Cancel deletion:
press ON/OFF button
1
while Β«
CL ALL
Β» is
flashing.
5. Battery Indicator and Battery change
Low battery
When the batteries are approximately ΒΎ empty the battery symbol AQ
will flash as soon as the device is switched on (partly filled battery
displayed). Although the device will continue to measure reliably, you
should obtain replacement batteries.
Flat battery – replacement
When the batteries are flat, the battery symbol AQ will flash as soon
as the device is switched on (flat battery displayed). You cannot take
any further measurements and must replace the batteries.
1. Open the battery compartment 5 by pulling off the cap.
2. Replace the batteries – ensure correct polarity as shown by the
symbols in the compartment.
3. To set date and time, follow the procedure described in Β«Section 1.Β».

The memory retains all values although date and time must be
reset – the year number therefore flashes automatically after
the batteries are replaced.
Which batteries and which procedure?

Use 2 new, long-life 1.5 V, size AAA alkaline batteries.

Do not use batteries beyond their date of expiry.

Remove batteries if the device is not going to be used for a
prolonged period.
Using rechargeable batteries
You can also operate this device using rechargeable batteries.

Only use Β«NiMHΒ» type reusable batteries.

Batteries must be removed and recharged when the flat
battery symbol appears. They should not remain inside the
device as they may become damaged (total discharge as a
result of low use of the device, even when switched off).
6

Always remove the rechargeable batteries if you do not intend
to use the device for a week or more.

Batteries cannot be charged in the blood pressure monitor.
Recharge batteries in an external charger and observe the
information regarding charging, care and durability.
6. Error Messages
If an error occurs during the measurement, the measurement is inter-
rupted and an error message, e.g. Β«ERR 3Β», is displayed.
* Please immediately consult your doctor, if this or any other problem
occurs repeatedly.

If you think the results are unusual, please read through the
information in Β«Section 1.Β» carefully.
7. Safety, Care, Accuracy Test and Disposal

Safety and protection
β€’ Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device and
keep for future reference.
Error Description Potential cause and remedy
Β«
ERR 1
Β»
AN
Signal too
weak
The pulse signals on the cuff are too weak. Re-
position the cuff and repeat the measurement.*
Β«
ERR 2
Β»
AO
Error signal During the measurement, error signals were
detected by the cuff, caused for instance by
movement or muscle tension. Repeat the
measurement, keeping your arm still.
Β«
ERR 3
Β»
AO
No pressure
in the cuff
An adequate pressure cannot be generated in
the cuff. A leak may have occurred. Check that
the cuff is correctly connected and is not too
loose. Replace the batteries if necessary.
Repeat the measurement.
Β«
ERR 5
Β» Abnormal
result
The measuring signals are inaccurate and no
result can therefore be displayed. Read through
the checklist for performing reliable measure-
ments and then repeat the measurement.*
Β«
HI
Β» Pulse or cuff
pressure too
high
The pressure in the cuff is too high (over
299 mmHg) OR the pulse is too high (over
200 beats per minute). Relax for 5 minutes
and repeat the measurement.*
Β«
LO
Β» Pulse too
low
The pulse is too low (less than 40 beats per
minute). Repeat the measurement.*
Error Description Potential cause and remedy
7BP W3 Comfort
EN
β€’ This device may only be used for the purposes described in these
instructions. The manufacturer cannot be held liable for damage
caused by incorrect application.
β€’ This device comprises sensitive components and must be treated
with caution. Observe the storage and operating conditions
described in the Β«Technical SpecificationsΒ» section.
β€’ Protect it from:
- water and moisture
- extreme temperatures
- impact and dropping
- contamination and dust
- direct sunlight
- heat and cold
β€’ The cuffs are sensitive and must be handled with care.
β€’ Only pump up the cuff once fitted.
β€’ Do not use this device close to strong electromagnetic fields such
as mobile telephones or radio installations. Keep a minimum
distance of 3.3 m from such devices when using this device.
β€’ Do not use this device if you think it is damaged or notice anything
unusual.
β€’ Never open this device.
β€’ If the device is not going to be used for a prolonged period the
batteries should be removed.
β€’ Read the additional safety information provided within the indi-
vidual sections of this instruction manual.
β€’ The measurement results given by this device is not a diagnosis.
It is not replacing the need for the consultation of a physician,
especially if not matching the patient’s symptoms. Do not rely on
the measurement result only, always consider other potentially
occurring symptoms and the patient’s feedback. Calling a doctor
or an ambulance is advised if needed.
Ensure that children do not use this device unsupervised;
some parts are small enough to be swallowed. Be aware of
the risk of strangulation in case this device is supplied with
cables or tubes.
Device care
Clean the device only with a soft, dry cloth.
Cleaning the cuff
Carefully remove any marks on the cuff with a damp cloth and mild
detergent.
Accuracy test
We recommend this device is tested for accuracy every 2 years or
after mechanical impact (e.g. being dropped). Please contact your
local Microlife-Service to arrange the test (see foreword).
Disposal
Batteries and electronic devices must be disposed of in accor-
dance with the locally applicable regulations, not with
domestic waste.
8
8. Guarantee
This device is covered by a
5
year guarantee
from the date of
purchase. The guarantee is valid only on presentation of the guarantee
card completed by the dealer (see back) confirming date of purchase
or the receipt.
β€’
Batteries, cuff and parts that become worn with use are not included.
β€’ Opening or altering the device invalidates the guarantee.
β€’ The guarantee does not cover damage caused by improper
handling, discharged batteries, accidents or non-compliance with
the operating instructions.
Please contact your local Microlife-Service (see foreword).
9. Technical Specifications
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
Operating conditions: 10 - 40 Β°C / 50 - 104 Β°F
15 - 95 % relative maximum humidity
Storage conditions: -20 - +55 Β°C / -4 - +131 Β°F
15 - 95 % relative maximum humidity
Weight: 112
g (including batteries)
Dimensions: 81 x 65 x 21
mm
Cuff size: 13.5 - 23 cm (5.25 - 9.05 inches)
Measuring procedure:
oscillometric, corresponding to Korotkoff
method: Phase I systolic, Phase V diastolic
Measurement range: 20 - 280 mmHg – blood pressure
40 - 200 beats per minute – pulse
Cuff pressure display
range: 0 - 299 mmHg
Resolution: 1 mmHg
Static accuracy: pressure within Β± 3 mmHg
Pulse accuracy: Β± 5 % of the readout value
Voltage source: 2 x 1.5 V alkaline batteries; size AAA
Battery lifetime: approx. 320 measurements
(using new batteries)
IP Class: IP20
Reference to
standards:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life: Device: 5 years or 10000 measurements
Accessories: 2 years
9BP W3 Comfort
RU
ДисплСй
ΠŸΠ΅Ρ€Π΅Π΄ использованиСм ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° Π²Π½ΠΈΠΌΠ°Ρ‚Π΅Π»ΡŒΠ½ΠΎ ΠΏΡ€ΠΎΡ‡Ρ‚ΠΈΡ‚Π΅
Π΄Π°Π½Π½ΠΎΠ΅ руководство.
ИздСлиС Ρ‚ΠΈΠΏΠ° BF
ΠŸΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅:
Π­Ρ‚ΠΎΡ‚ осцилломСтричСский Ρ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€ ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½ для Π½Π΅ΠΈΠ½Π²Π°-
Π·ΠΈΠ²Π½ΠΎΠ³ΠΎ измСрСния Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния Ρƒ людСй Π² возрастС
12 Π»Π΅Ρ‚ ΠΈ ΡΡ‚Π°Ρ€ΡˆΠ΅.
Π£Π²Π°ΠΆΠ°Π΅ΠΌΡ‹ΠΉ ΠΏΠΎΠΊΡƒΠΏΠ°Ρ‚Π΅Π»ΡŒ,
ΠŸΡ€ΠΈΠ±ΠΎΡ€ Π±Ρ‹Π» Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½ Π² сотрудничСствС с Π²Ρ€Π°Ρ‡Π°ΠΌΠΈ, Π° ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅-
скиС тСсты ΠΏΠΎΠ΄Ρ‚Π²Π΅Ρ€Π΄ΠΈΠ»ΠΈ Π²Ρ‹ΡΠΎΠΊΡƒΡŽ Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ Π΅Π³ΠΎ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ.*
ΠŸΡ€ΠΈ Π²ΠΎΠ·Π½ΠΈΠΊΠ½ΠΎΠ²Π΅Π½ΠΈΠΈ вопросов, ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌ ΠΈΠ»ΠΈ для Π·Π°ΠΊΠ°Π·Π° запасных
частСй, поТалуйста, ΠΎΠ±Ρ€Π°Ρ‰Π°ΠΉΡ‚Π΅ΡΡŒ Π²
мСстный сСрвисный Ρ†Π΅Π½Ρ‚Ρ€
Microlife. Π’Π°Ρˆ Π΄ΠΈΠ»Π΅Ρ€ ΠΈΠ»ΠΈ Π°ΠΏΡ‚Π΅ΠΊΠ° ΠΌΠΎΠ³ΡƒΡ‚ ΠΏΡ€Π΅Π΄ΠΎΡΡ‚Π°Π²ΠΈΡ‚ΡŒ Π’Π°ΠΌ адрСс
Π΄ΠΈΠ»Π΅Ρ€Π° Microlife Π² Π’Π°ΡˆΠ΅ΠΉ странС. Π’ качСствС Π°Π»ΡŒΡ‚Π΅Ρ€Π½Π°Ρ‚ΠΈΠ²Ρ‹,
Microlife BP W3 Comfort
RU
1
Кнопка Π’ΠšΠ›/Π’Π«ΠšΠ›
2
ДисплСй
3
Кнопка M (ΠŸΠ°ΠΌΡΡ‚ΡŒ)
4
Кнопка Time (ВрСмя)
5
ΠžΡ‚ΡΠ΅ΠΊ для Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ
6
ΠœΠ°Π½ΠΆΠ΅Ρ‚Π°
7
БистоличСскоС Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
8
ДиастоличСскоС Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
9
Частота ΠΏΡƒΠ»ΡŒΡΠ°
AT
Π”Π°Ρ‚Π°/ВрСмя
AK
Π‘ΠΎΡ…Ρ€Π°Π½Π΅Π½Π½ΠΎΠ΅ Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅
AL
Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ уровня давлСния
AM
Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ Π°Ρ€ΠΈΡ‚ΠΌΠΈΠΈ ΠΏΡƒΠ»ΡŒΡΠ° (PAD)
AN
Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ сигнала ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹ Β«ERR 1Β»
AO
ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° размСщСния ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹
-A: ΠžΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½ΠΎΠ΅ ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹
-B: Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ двиТСния Ρ€ΡƒΠΊΠΈ Β«ERR 2Β»
-C: ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ давлСния ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹ Β«ERR 3Β»
AP
Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€
ΠΏΡƒΠ»ΡŒΡΠ°
AQ
Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ разряда Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ
Π₯Ρ€Π°Π½ΠΈΡ‚ΡŒ Π² сухом мСстС
10
посСтитС Π² Π˜Π½Ρ‚Π΅Ρ€Π½Π΅Ρ‚Π΅ страницу www.microlife.com, Π³Π΄Π΅ Π’Ρ‹
смоТСтС Π½Π°ΠΉΡ‚ΠΈ ряд ΠΏΠΎΠ»Π΅Π·Π½Ρ‹Ρ… свСдСний ΠΏΠΎ Π½Π°ΡˆΠ΅ΠΌΡƒ издСлию.
Π‘ΡƒΠ΄ΡŒΡ‚Π΅ Π·Π΄ΠΎΡ€ΠΎΠ²Ρ‹ – Microlife AG!
* Π­Ρ‚ΠΎΡ‚ ΠΏΡ€ΠΈΠ±ΠΎΡ€ протСстирован Π² соотвСтствии с ΠΏΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ»ΠΎΠΌ
ЕвропСйского ΠžΠ±Ρ‰Π΅ΡΡ‚Π²Π° Π“ΠΈΠΏΠ΅Ρ€Ρ‚ΠΎΠ½ΠΈΠΈ (ESH) ΠΈ ISO81060-2:2013.
Table of Contents
1. Using the Device for the First Time
β€’ Inserting the batteries
β€’ Setting the date and time
2. Checklist for Taking a Reliable Measurement
3. Taking a Blood Pressure Measurement
β€’ How not to store a reading
β€’ How do I evaluate my blood pressure?
β€’ Appearance of the Pulse Arrhythmia (PAD)
F How not to store a reading
F How do I evaluate my blood pressure?
F Appearance of the Pulse Arrhythmia (PAD)
4. Data Memory
β€’ Viewing the stored values
β€’ Memory full
β€’ Clearing all values
5. Battery Indicator and Battery change
β€’ Low battery
β€’ Flat battery – replacement
β€’ Which batteries and which procedure?
β€’ Using rechargeable batteries
6. Error Messages
7. Safety, Care, Accuracy Test and Disposal
β€’ Safety and protection
β€’Device care
β€’ Cleaning the cuff
β€’ Accuracy test
β€’Disposal
8. Guarantee
9. Technical Specifications
Guarantee Card (see Back Cover)
1. ИспользованиС ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° Π² ΠΏΠ΅Ρ€Π²Ρ‹ΠΉ Ρ€Π°Π·
Установка Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ
ПослС Ρ‚ΠΎΠ³ΠΎ, ΠΊΠ°ΠΊ Π’Ρ‹ Π²Ρ‹Π½ΡƒΠ»ΠΈ ΠΏΡ€ΠΈΠ±ΠΎΡ€ ΠΈΠ· ΡƒΠΏΠ°ΠΊΠΎΠ²ΠΊΠΈ, ΠΏΡ€Π΅ΠΆΠ΄Π΅ всСго, Π²ΡΡ‚Π°Π²ΡŒΡ‚Π΅
Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ. ΠžΡ‚ΡΠ΅ΠΊ для Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ
5
располоТСн Π½Π° Π½ΠΈΠΆΠ½Π΅ΠΉ части ΠΏΡ€ΠΈΠ±ΠΎΡ€Π°.
Π’ΡΡ‚Π°Π²ΡŒΡ‚Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ (2 Ρ… Ρ‚ΠΈΠΏ AAA 1.5Π’), соблюдая ΠΏΠΎΠ»ΡΡ€Π½ΠΎΡΡ‚ΡŒ.
11BP W3 Comfort
RU
Установка Π΄Π°Ρ‚Ρ‹ ΠΈ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ
1. ПослС установки Π½ΠΎΠ²Ρ‹Ρ… Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ Π½Π° дисплСС Π·Π°ΠΌΠΈΠ³Π°Π΅Ρ‚ числовоС
Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ Π³ΠΎΠ΄Π°. Π“ΠΎΠ΄ устанавливаСтся Π½Π°ΠΆΠ°Ρ‚ΠΈΠ΅ΠΌ ΠΊΠ½ΠΎΠΏΠΊΠΈ M
3
. Для
Ρ‚ΠΎΠ³ΠΎ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΠΏΠΎΠ΄Ρ‚Π²Π΅Ρ€Π΄ΠΈΡ‚ΡŒ Π²Π²Π΅Π΄Π΅Π½Π½ΠΎΠ΅ Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ ΠΈ Π·Π°Ρ‚Π΅ΠΌ устано-
Π²ΠΈΡ‚ΡŒ мСсяц, Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΊΠ½ΠΎΠΏΠΊΡƒ Time (ВрСмя)
4
.
2. Π’Π΅ΠΏΠ΅Ρ€ΡŒ ΠΌΠΎΠΆΠ½ΠΎ ΡƒΡΡ‚Π°Π½ΠΎΠ²ΠΈΡ‚ΡŒ мСсяц Π½Π°ΠΆΠ°Ρ‚ΠΈΠ΅ΠΌ ΠΊΠ½ΠΎΠΏΠΊΠΈ M. Для
Ρ‚ΠΎΠ³ΠΎ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΠΏΠΎΠ΄Ρ‚Π²Π΅Ρ€Π΄ΠΈΡ‚ΡŒ Π²Π²Π΅Π΄Π΅Π½Π½ΠΎΠ΅ Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ ΠΈ Π·Π°Ρ‚Π΅ΠΌ устано-
Π²ΠΈΡ‚ΡŒ дСнь, Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΊΠ½ΠΎΠΏΠΊΡƒ Time (ВрСмя).
3. БлСдуя Π²Ρ‹ΡˆΠ΅ΠΏΡ€ΠΈΠ²Π΅Π΄Π΅Π½Π½Ρ‹ΠΌ инструкциям, установитС дСнь,
час ΠΈ ΠΌΠΈΠ½ΡƒΡ‚Ρ‹.
4. ПослС установки ΠΌΠΈΠ½ΡƒΡ‚ ΠΈ наТатия ΠΊΠ½ΠΎΠΏΠΊΠΈ Time (ВрСмя) Π½Π°
экранС появятся Π΄Π°Ρ‚Π° ΠΈ врСмя.
5. Для измСнСния Π΄Π°Ρ‚Ρ‹ ΠΈ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΈ ΡƒΠ΄Π΅Ρ€ΠΆΠΈΠ²Π°ΠΉΡ‚Π΅
ΠΊΠ½ΠΎΠΏΠΊΡƒ Time (ВрСмя) ΠΏΡ€ΠΈΠ±Π»ΠΈΠ·ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ 3 сСкунд, ΠΏΠΎΠΊΠ°
Π½Π΅ Π½Π°Ρ‡Π½Π΅Ρ‚ ΠΌΠΈΠ³Π°Ρ‚ΡŒ Π³ΠΎΠ΄. ПослС этого ΠΌΠΎΠΆΠ½ΠΎ ввСсти Π½ΠΎΠ²Ρ‹Π΅
значСния, ΠΊΠ°ΠΊ это описано Π²Ρ‹ΡˆΠ΅.
2. ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ список для провСдСния Π½Π°Π΄Π΅ΠΆΠ½ΠΎΠ³ΠΎ
измСрСния
1. Π˜Π·Π±Π΅Π³Π°ΠΉΡ‚Π΅ физичСской активности, Π½Π΅ Π΅ΡˆΡŒΡ‚Π΅ ΠΈ Π½Π΅ ΠΊΡƒΡ€ΠΈΡ‚Π΅ Π½Π΅ΠΏΠΎ-
срСдствСнно ΠΏΠ΅Ρ€Π΅Π΄ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅ΠΌ.
2. ΠŸΡ€ΠΈΡΡΠ΄ΡŒΡ‚Π΅ Π½Π° стул со спинкой Π½Π° ΠΏΡΡ‚ΡŒ ΠΌΠΈΠ½ΡƒΡ‚ ΠΈ Ρ€Π°ΡΡΠ»Π°Π±ΡŒΡ‚Π΅ΡΡŒ.
ΠŸΠΎΡΡ‚Π°Π²ΡŒΡ‚Π΅ Π½ΠΎΠ³ΠΈ Π½Π° ΠΏΠΎΠ» Ρ€ΠΎΠ²Π½ΠΎ ΠΈ Π½Π΅ скрСщивайтС ΠΈΡ….
3. ВсСгда ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚Π΅ измСрСния Π½Π° Ρ‚ΠΎΠΌ ΠΆΠ΅ Π·Π°ΠΏΡΡΡ‚ΡŒΠ΅ Π² ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΠΈ
сидя. Π˜ΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ Π·Π°ΠΏΡΡΡ‚ΡŒΠ΅, ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ΅ ΠΎΠ±Ρ‹Ρ‡Π½ΠΎ ΠΏΠΎΠΊΠ°Π·Ρ‹Π²Π°Π΅Ρ‚
Π±ΠΎΠ»Π΅Π΅ высокиС значСния
Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния.
4. Π‘Π½ΠΈΠΌΠΈΡ‚Π΅ ΠΎΠ΄Π΅ΠΆΠ΄Ρƒ ΠΈ, Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, часы, для Ρ‚ΠΎΠ³ΠΎ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ освобо-
Π΄ΠΈΡ‚ΡŒ Π·Π°ΠΏΡΡΡ‚ΡŒΠ΅.
5. Π£Π±Π΅Π΄ΠΈΡ‚Π΅ΡΡŒ, Ρ‡Ρ‚ΠΎ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅Ρ‚ΡΡ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π° ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½ΠΎΠ³ΠΎ Ρ€Π°Π·ΠΌΠ΅Ρ€Π°
(ΠΌΠ°Ρ€ΠΊΠΈΡ€ΠΎΠ²ΠΊΠ° Π½Π° ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π΅).
6. Π£Π΄ΠΎΠ±Π½ΠΎ Π½Π°Π»ΠΎΠΆΠΈΡ‚Π΅ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρƒ, Π½ΠΎ Π½Π΅ слишком Ρ‚ΡƒΠ³ΠΎ. ΠœΠ°Π½ΠΆΠ΅Ρ‚Π° рассчи-
Ρ‚Π°Π½Π° Π½Π° Π·Π°ΠΏΡΡΡ‚ΡŒΠ΅ ΠΎΠ±Ρ…Π²Π°Ρ‚ΠΎΠΌ ΠΎΡ‚ 13,5 - 23 см (5,25 - 9,05 дюймов).
7. РасполоТитС Ρ€ΡƒΠΊΡƒ Ρ‚Π°ΠΊ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΠΎΠ½Π° ΠΎΡΡ‚Π°Π²Π°Π»Π°ΡΡŒ расслаблСнной
ΠΈ ΡƒΠ±Π΅Π΄ΠΈΡ‚Π΅ΡΡŒ Π² Ρ‚ΠΎΠΌ, Ρ‡Ρ‚ΠΎ ΠΏΡ€ΠΈΠ±ΠΎΡ€ находится Π½Π° Ρ‚ΠΎΠΉ ΠΆΠ΅ высотС,
Ρ‡Ρ‚ΠΎ ΠΈ сСрдцС.
3. Π’Ρ‹ΠΏΠΎΠ»Π½Π΅Π½ΠΈΠ΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния
8. НаТмитС ΠΊΠ½ΠΎΠΏΠΊΡƒ Π’ΠšΠ›/Π’Π«ΠšΠ› 1 для Π½Π°Ρ‡Π°Π»Π° измСрСния.
9. ПолоТСниС ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹ рСгистрируСтся Π½Π° дисплСС AO ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π°
располоТСна ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½ΠΎ. Если появляСтся Π·Π½Π°Ρ‡ΠΎΠΊ AO-A,
ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π° устанавлСна достаточно Ρ…ΠΎΡ€ΠΎΡˆΠΎ ΠΈ всС Ρ€Π°Π²Π½ΠΎ ΠΌΠΎΠΆΠ½ΠΎ
ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚ΡŒ Π½ΠΎΡ€ΠΌΠ°Π»ΡŒΠ½ΠΎΠ΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅.
10.Π’Π΅ΠΏΠ΅Ρ€ΡŒ Π±ΡƒΠ΄Π΅Ρ‚ ΠΏΡ€ΠΎΠΈΠ·Π²Π΅Π΄Π΅Π½Π° автоматичСская Π½Π°ΠΊΠ°Ρ‡ΠΊΠ° ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹.
Π Π°ΡΡΠ»Π°Π±ΡŒΡ‚Π΅ΡΡŒ, Π½Π΅ Π΄Π²ΠΈΠ³Π°ΠΉΡ‚Π΅ΡΡŒ ΠΈ Π½Π΅ напрягайтС Ρ€ΡƒΠΊΡƒ Π΄ΠΎ Ρ‚Π΅Ρ… ΠΏΠΎΡ€,
ΠΏΠΎΠΊΠ° Π½Π΅ отобразится Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ измСрСния. Π”Ρ‹ΡˆΠΈΡ‚Π΅ Π½ΠΎΡ€ΠΌΠ°Π»ΡŒΠ½ΠΎ ΠΈ
Π½Π΅ Ρ€Π°Π·Π³ΠΎΠ²Π°Ρ€ΠΈΠ²Π°ΠΉΡ‚Π΅.
11.Π˜Π·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅ происходит Π²ΠΎ врСмя Π½Π°ΠΊΠ°Ρ‡ΠΊΠΈ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹. Π‘ΠΊΠΎΡ€ΠΎΡΡ‚ΡŒ
Π½Π°ΠΊΠ°Ρ‡ΠΊΠΈ ΠΌΠΎΠΆΠ΅Ρ‚ Ρ€Π°Π·Π»ΠΈΡ‡Π°Ρ‚ΡŒΡΡ.
12.Π’ΠΎ врСмя измСрСния, ΠΈΠ½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ ΠΏΡƒΠ»ΡŒΡΠ°
AP
ΠΌΠΈΠ³Π°Π΅Ρ‚ Π½Π° дисплСС.
12
13.Π—Π°Ρ‚Π΅ΠΌ отобраТаСтся Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚, состоящий ΠΈΠ· систоличСского
7
ΠΈ
диастоличСского
8
Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния, Π° Ρ‚Π°ΠΊΠΆΠ΅ ΠΏΡƒΠ»ΡŒΡΠ°
9
. Π‘ΠΌ.
Ρ‚Π°ΠΊΠΆΠ΅ пояснСния ΠΏΠΎ Π΄Ρ€ΡƒΠ³ΠΈΠΌ показаниям дисплСя Π² этой инструкции.
14.Π‘Π½ΠΈΠΌΠΈΡ‚Π΅ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρƒ ΠΈ Π²Ρ‹ΠΊΠ»ΡŽΡ‡ΠΈΡ‚Π΅ Ρ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€, занСситС Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚
Π² ΠΏΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½Π½ΡƒΡŽ ΠΊΠ°Ρ€Ρ‚ΠΎΡ‡ΠΊΡƒ Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния. (Π’ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€
автоматичСски ΠΎΡ‚ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ΡΡ ΠΏΡ€ΠΈΠ±Π»ΠΈΠ·ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ Ρ‡Π΅Ρ€Π΅Π· 1 ΠΌΠΈΠ½ΡƒΡ‚Ρƒ).

Π’Ρ‹ ΠΌΠΎΠΆΠ΅Ρ‚Π΅ ΠΎΡΡ‚Π°Π½ΠΎΠ²ΠΈΡ‚ΡŒ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅ Π² любой ΠΌΠΎΠΌΠ΅Π½Ρ‚ Π½Π°ΠΆΠ°Ρ‚ΠΈΠ΅ΠΌ
ΠΊΠ½ΠΎΠΏΠΊΠΈ Π’ΠšΠ›/Π’Π«ΠšΠ› (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, Ссли Π’Ρ‹ испытываСтС Π½Π΅ΡƒΠ΄ΠΎΠ±-
ство ΠΈΠ»ΠΈ нСприятноС ΠΎΡ‰ΡƒΡ‰Π΅Π½ΠΈΠ΅ ΠΎΡ‚ Π½Π°Π³Π½Π΅Ρ‚Π°Π΅ΠΌΠΎΠ³ΠΎ давлСния).
Как ΠΎΡ‚ΠΌΠ΅Π½ΠΈΡ‚ΡŒ сохранСниС Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°
Когда Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ появится Π½Π° дисплСС, Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΈ Π΄Π΅Ρ€ΠΆΠΈΡ‚Π΅
Π½Π°ΠΆΠ°Ρ‚ΠΎΠΉ ΠΊΠ½ΠΎΠΏΠΊΡƒ Π²ΠΊΠ»ΡŽΡ‡Π΅Π½ΠΈΡ / Π²Ρ‹ΠΊΠ»ΡŽΡ‡Π΅Π½ΠΈΡ 1 ΠΏΠΎΠΊΠ° ΠΊΠ½ΠΎΠΏΠΊΠ° Β«MΒ» AK
Π½Π΅ Π½Π°Ρ‡Π½Π΅Ρ‚ ΠΌΠΈΠ³Π°Ρ‚ΡŒ. ΠŸΠΎΠ΄Ρ‚Π²Π΅Ρ€Π΄ΠΈΡ‚Π΅ ΡƒΠ΄Π°Π»Π΅Π½ΠΈΠ΅, Π½Π°ΠΆΠ°Π² ΠΊΠ½ΠΎΠΏΠΊΡƒ time AK.

Β«CLΒ» Π½Π° дисплСС ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° ΠΎΠ·Π½Π°Ρ‡Π°Π΅Ρ‚ ΡƒΠ΄Π°Π»Π΅Π½ΠΈΠ΅ ΠΈΠ· памяти-
ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΎ ΡƒΡΠΏΠ΅ΡˆΠ½ΠΎ.
Как ΠΎΠΏΡ€Π΅Π΄Π΅Π»ΠΈΡ‚ΡŒ Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅?
Π’Ρ€Π΅ΡƒΠ³ΠΎΠ»ΡŒΠ½ΠΈΠΊ Π² Π»Π΅Π²ΠΎΠΉ части дисплСя
AL
ΡƒΠΊΠ°Π·Ρ‹Π²Π°Π΅Ρ‚ Π½Π° Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½, Π²
ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠΉ ΠΏΠΎΠΏΠ°Π΄Π°Π΅Ρ‚ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΎΠ΅ Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅. Π˜Π·ΠΌΠ΅Ρ€Π΅Π½ΠΎΠ΅
Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ находится Π»ΠΈΠ±ΠΎ Π² ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½ΠΎΠΌ (Π·Π΅Π»Π΅Π½ΠΎΠΌ), ΠΏΠΎΠ²Ρ‹ΡˆΠ΅Π½Π½ΠΎΠΌ
(ΠΆΠ΅Π»Ρ‚ΠΎΠΌ), Π»ΠΈΠ±ΠΎ высоком (красном) Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅. ΠšΠ»Π°ΡΡΠΈΡ„ΠΈΠΊΠ°Ρ†ΠΈΡ
Π΄Π°Π½Π½Ρ‹Ρ… ΠΏΠΎ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½Π½ΠΎΠΌΡƒ давлСнию Π½Π° Π΄ΠΈΠ°ΠΏΠΎΠ·ΠΎΠ½Ρ‹ происходит ΠΏΠΎ
ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΌ Π΄ΠΈΡ€Π΅ΠΊΡ‚ΠΈΠ²Π°ΠΌ (ESH, ESC, JSH). Π”Π°Π½Π½Ρ‹Π΅ Π²Ρ‹Ρ€Π°ΠΆΠ΅Π½Ρ‹ Π²
ΠΌΠΌ Ρ€Ρ‚.
ΠžΡ†Π΅Π½ΠΊΠ° давлСния опрСдСляСтся ΠΏΠΎ Π½Π°ΠΈΠ²Ρ‹ΡΡˆΠ΅ΠΌΡƒ Π·Π½Π°Ρ‡Π΅Π½ΠΈΡŽ.
НапримСр: Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
140/80
ΠΌΠΌ Ρ€Ρ‚.ст. ΠΈ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
130/90
ΠΌΠΌ Ρ€Ρ‚.ст.
ΠΎΠ±Π° ΠΎΡ†Π΅Π½ΠΈΠ²Π°ΡŽΡ‚ΡΡ ΠΊΠ°ΠΊ Β«Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ ΠΎΡ‡Π΅Π½ΡŒ высокоС».
ПоявлСниС ΠΈΠ½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€Π° Π°Ρ€ΠΈΡ‚ΠΌΠΈΠΈ ΠΏΡƒΠ»ΡŒΡΠ° (PAD)
Π­Ρ‚ΠΎΡ‚ символ AM ΡƒΠΊΠ°Π·Ρ‹Π²Π°Π΅Ρ‚ Π½Π° Ρ‚ΠΎ, Ρ‡Ρ‚ΠΎ Π²ΠΎ врСмя измСрСния Π±Ρ‹Π»ΠΈ
выявлСны Π½Π°Ρ€ΡƒΡˆΠ΅Π½ΠΈΡ ΠΏΡƒΠ»ΡŒΡΠ°. Π’ этом случаС Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ ΠΌΠΎΠΆΠ΅Ρ‚
ΠΎΡ‚Π»ΠΈΡ‡Π°Ρ‚ΡŒΡΡ ΠΎΡ‚ Π’Π°ΡˆΠ΅Π³ΠΎ Π½ΠΎΡ€ΠΌΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния –
ΠΏΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅. Π’ Π±ΠΎΠ»ΡŒΡˆΠΈΠ½ΡΡ‚Π²Π΅ случаСв это Π½Π΅ являСтся
ΠΏΡ€ΠΈΡ‡ΠΈΠ½ΠΎΠΉ для бСспокойства. Однако Ссли Ρ‚Π°ΠΊΠΎΠΉ символ появля-
Стся рСгулярно (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, нСсколько Ρ€Π°Π· Π²
нСдСлю ΠΏΡ€ΠΈ Π΅ΠΆΠ΅Π΄-
Π½Π΅Π²Π½Ρ‹Ρ… измСрСниях), рСкомСндуСтся ΡΠΎΠΎΠ±Ρ‰ΠΈΡ‚ΡŒ ΠΎΠ± этом Π²Ρ€Π°Ρ‡Ρƒ.
ΠŸΠΎΠΊΠ°ΠΆΠΈΡ‚Π΅ Π²Ρ€Π°Ρ‡Ρƒ ΠΏΡ€ΠΈΠ²Π΅Π΄Π΅Π½Π½ΠΎΠ΅ Π½ΠΈΠΆΠ΅ объяснСниС:
Π”ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½
Бисто-
Π»ΠΈΡ‡Π΅-
скоС
Диасто-
Π»ΠΈΡ‡Π΅-
скоС РСкомСндация
1. Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅
Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
слишком высокоС
β‰₯135 β‰₯85 ΠžΠ±Ρ€Π°Ρ‚ΠΈΡ‚Π΅ΡΡŒ Π·Π°
мСдицинской
ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ
2. ΠΏΠΎΠ²Ρ‹ΡˆΠ΅Π½Π½ΠΎΠ΅
Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅
Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
130 - 134 80 - 84 Π‘Π°ΠΌΠΎΡΡ‚ΠΎΡΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ
3. Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅
Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ Π² Π½ΠΎΡ€ΠΌΠ΅
<130 <80 Π‘Π°ΠΌΠΎΡΡ‚ΠΎΡΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ
13BP W3 Comfort
RU
4. ΠŸΠ°ΠΌΡΡ‚ΡŒ
Π­Ρ‚ΠΎ устройство автоматичСски сохраняСт послСдниС 30 ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ.
ΠŸΡ€ΠΎΡΠΌΠΎΡ‚Ρ€ сохранСнных Π²Π΅Π»ΠΈΡ‡ΠΈΠ½
ΠšΠΎΡ€ΠΎΡ‚ΠΊΠΎ Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΊΠ½ΠΎΠΏΠΊΡƒ M 3 ΠΏΡ€ΠΈ Π²Ρ‹ΠΊΠ»ΡŽΡ‡Π΅Π½Π½ΠΎΠΌ ΠΏΡ€ΠΈΠ±ΠΎΡ€Π΅.
Π‘Π½Π°Ρ‡Π°Π»Π° Π½Π° дисплСС покаТСтся Π·Π½Π°ΠΊ Β«MΒ» AK ΠΈ Β«AΒ», ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ
ΠΎΠ±ΠΎΠ·Π½Π°Ρ‡Π°Π΅Ρ‚ срСднСС всСх сохранСнных Π·Π½Π°Ρ‡Π΅Π½ΠΈΠΉ.
ΠŸΠΎΠ²Ρ‚ΠΎΡ€Π½ΠΎΠ΅ Π½Π°ΠΆΠ°Ρ‚ΠΈΠ΅ ΠΊΠ½ΠΎΠΏΠΊΠΈ M ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°Π΅Ρ‚ ΠΏΡ€Π΅Π΄Ρ‹Π΄ΡƒΡ‰Π΅Π΅
Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅. ΠœΠ½ΠΎΠ³ΠΎΠΊΡ€Π°Ρ‚Π½ΠΎΠ΅ Π½Π°ΠΆΠ°Ρ‚ΠΈΠ΅ ΠΊΠ½ΠΎΠΏΠΊΠΈ M позволяСт ΠΏΠ΅Ρ€Π΅ΠΊΠ»ΡŽ-
Ρ‡Π°Ρ‚ΡŒΡΡ ΠΌΠ΅ΠΆΠ΄Ρƒ сохранСнными значСниями.

ΠΡ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½Π½ΠΎΠ΅ ΠΏΡ€ΠΈ ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΠΈΠΌΠ°Π½-
ΠΆΠ΅Ρ‚Ρ‹ AO-A Π½Π΅ ΡƒΡ‡ΠΈΡ‚Ρ‹Π²Π°ΡŽΡ‚ΡΡ Π² срСднСм Π·Π½Π°Ρ‡Π΅Π½ΠΈΠΈ
Π—Π°ΠΏΠΎΠ»Π½Π΅Π½ΠΈΠ΅ памяти

ΠžΠ±Ρ€Π°Ρ‚ΠΈΡ‚Π΅ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅, Ρ‡Ρ‚ΠΎ ΠΌΠ°ΠΊΡΠΈΠΌΠ°Π»ΡŒΠ½Ρ‹ΠΉ объСм памяти Π² 30
ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ Π½Π΅ ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ ΠΏΡ€Π΅Π²Ρ‹ΡˆΠ΅Π½.
Когда ΠΏΠ°ΠΌΡΡ‚ΡŒ Π·Π°ΠΏΠΎΠ»Π½Π΅Π½Π°,
31 ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅ записываСтся вмСсто самого Ρ€Π°Π½Π½Π΅Π³ΠΎ.
ЗначСния Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π±Ρ‹Ρ‚ΡŒ отслСТСны Π²Ρ€Π°Ρ‡ΠΎΠΌ Π΄ΠΎ достиТСния
максимального объСма памяти – ΠΈΠ½Π°Ρ‡Π΅ Π΄Π°Π½Π½Ρ‹Π΅ Π±ΡƒΠ΄ΡƒΡ‚ потСряны.
Π£Π΄Π°Π»Π΅Π½ΠΈΠ΅ всСх Π·Π½Π°Ρ‡Π΅Π½ΠΈΠΉ
Если Π’Ρ‹ Ρ…ΠΎΡ‚ΠΈΡ‚Π΅ ΠΎΠΊΠΎΠ½Ρ‡Π°Ρ‚Π΅Π»ΡŒΠ½ΠΎ ΡƒΠ΄Π°Π»ΠΈΡ‚ΡŒ всС сохранСнныС
впамяти Π΄Π°Π½Π½Ρ‹Π΅, Π²Ρ‹ΠΊΠ»ΡŽΡ‡ΠΈΡ‚Π΅ устройство, Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΈ ΠΈ Π΄Π΅Ρ€ΠΆΠΈΡ‚Π΅
Π½Π°ΠΆΠ°Ρ‚ΠΎΠΉ ΠΊΠ½ΠΎΠΏΠΊΡƒ M, ΠΏΠΎΠΊΠ° Π½Π΅ появится Β«CL ALLΒ» Π·Π°Ρ‚Π΅ΠΌ отпуститС
ΠΊΠ½ΠΎΠΏΠΊΡƒ.Π§Ρ‚ΠΎΠ±Ρ‹ ΠΏΠΎΠ»Π½ΠΎΡΡ‚ΡŒΡŽ ΠΎΡ‡ΠΈΡΡ‚ΠΈΡ‚ΡŒ ΠΏΠ°ΠΌΡΡ‚ΡŒ, Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΊΠ½ΠΎΠΏΠΊΡƒ
Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ, ΠΏΠΎΠΊΠ° Β«CL ALLΒ» ΠΌΠΈΠ³Π°Π΅Ρ‚. Π˜Π½Π΄ΠΈΠ²ΠΈΠ΄ΡƒΠ°Π»ΡŒΠ½Ρ‹Π΅ значСния Π½Π΅
ΠΌΠΎΠ³ΡƒΡ‚ Π±Ρ‹Ρ‚ΡŒ ΡƒΠ΄Π°Π»Π΅Π½Ρ‹.

ΠžΡ‚ΠΌΠ΅Π½Π° удалСния: Π½Π°ΠΆΠΌΠΈΡ‚Π΅ ΠΊΠ½ΠΎΠΏΠΊΡƒ Π’ΠšΠ›/Π’Π«ΠšΠ› 1, ΠΏΠΎΠΊΠ°
Β«CL ALLΒ» ΠΌΠΈΠ³Π°Π΅Ρ‚.
5. Π˜Π½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€ разряда Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ ΠΈ ΠΈΡ… Π·Π°ΠΌΠ΅Π½Π°
Π‘Π°Ρ‚Π°Ρ€Π΅ΠΈ ΠΏΠΎΡ‡Ρ‚ΠΈ разряТСны
Если Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½Ρ‹ ΠΏΡ€ΠΈΠ±Π»ΠΈΠ·ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ Π½Π° ΒΎ, Ρ‚ΠΎ ΠΏΡ€ΠΈ вклю-
Ρ‡Π΅Π½ΠΈΠΈ ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° символ элСмСнтов питания AQ Π±ΡƒΠ΄Π΅Ρ‚ ΠΌΠΈΠ³Π°Ρ‚ΡŒ
(отобраТаСтся частично заряТСнная батарСя). НСсмотря Π½Π° Ρ‚ΠΎ,
Ρ‡Ρ‚ΠΎ ΠΏΡ€ΠΈΠ±ΠΎΡ€ ΠΏΡ€ΠΎΠ΄ΠΎΠ»ΠΆΠΈΡ‚ Π½Π°Π΄Π΅ΠΆΠ½ΠΎ ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚ΡŒ измСрСния, Π½Π΅ΠΎΠ±Ρ…ΠΎ-
Π΄ΠΈΠΌΠΎ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΈΡ‚ΡŒ Π½ΠΎΠ²Ρ‹Π΅ элСмСнты питания Π½Π° Π·Π°ΠΌΠ΅Π½Ρƒ.
Π˜Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡ для Π²Ρ€Π°Ρ‡Π° ΠΏΡ€ΠΈ частом появлСнии Π½Π°
дисплСС ΠΈΠ½Π΄ΠΈΠΊΠ°Ρ‚ΠΎΡ€Π° Π°Ρ€ΠΈΡ‚ΠΌΠΈΠΈ
Π­Ρ‚ΠΎΡ‚ ΠΏΡ€ΠΈΠ±ΠΎΡ€ являСтся осцилломСтричСским ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»Π΅ΠΌ
Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ давлСния, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ Π°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΡƒΠ΅Ρ‚ Ρ‚Π°ΠΊΠΆΠ΅ Π½Π΅Ρ€Π΅-
Π³ΡƒΠ»ΡΡ€Π½ΠΎΡΡ‚ΡŒ ΠΏΡƒΠ»ΡŒΡΠ° Π²ΠΎ врСмя измСрСния. ΠŸΡ€ΠΈΠ±ΠΎΡ€ ΠΏΡ€ΠΎΡˆΠ΅Π»
клиничСскиС испытания.
Π‘ΠΈΠΌΠ²ΠΎΠ» Π°Ρ€ΠΈΡ‚ΠΌΠΈΠΈ отобраТаСтся послС измСрСния, Ссли Π²ΠΎ
врСмя измСрСния ΠΈΠΌΠ΅Π»ΠΈ мСсто Π½Π°Ρ€ΡƒΡˆΠ΅Π½ΠΈΡ ΠΏΡƒΠ»ΡŒΡΠ°. Если этот
символ появляСтся достаточно часто (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, нСсколько Ρ€Π°Π·
Π² нСдСлю ΠΏΡ€ΠΈ Π΅ΠΆΠ΅Π΄Π½Π΅Π²Π½Ρ‹Ρ… измСрСниях), Ρ‚ΠΎ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Ρƒ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½-
дуСтся ΠΎΠ±Ρ€Π°Ρ‚ΠΈΡ‚ΡŒΡΡ Π·Π° мСдицинской ΠΊΠΎΠ½ΡΡƒΠ»ΡŒΡ‚Π°Ρ†ΠΈΠ΅ΠΉ.
ΠŸΡ€ΠΈΠ±ΠΎΡ€ Π½Π΅ замСняСт кардиологичСского обслСдования, ΠΎΠ΄Π½Π°ΠΊΠΎ
позволяСт Π²Ρ‹ΡΠ²ΠΈΡ‚ΡŒ Π½Π°Ρ€ΡƒΡˆΠ΅Π½ΠΈΡ ΠΏΡƒΠ»ΡŒΡΠ° Π½Π° Ρ€Π°Π½Π½Π΅ΠΉ стадии.
14
Π—Π°ΠΌΠ΅Π½Π° разряТСнных Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ
Если Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ разряТСны, Ρ‚ΠΎ ΠΏΡ€ΠΈ Π²ΠΊΠ»ΡŽΡ‡Π΅Π½ΠΈΠΈ ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° символ
элСмСнтов питания AQ Π±ΡƒΠ΄Π΅Ρ‚ ΠΌΠΈΠ³Π°Ρ‚ΡŒ (отобраТаСтся разряТСнная
батарСя). Π”Π°Π»ΡŒΠ½Π΅ΠΉΡˆΠΈΠ΅ измСрСния Π½Π΅ ΠΌΠΎΠ³ΡƒΡ‚ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚ΡŒΡΡ Π΄ΠΎ
Π·Π°ΠΌΠ΅Π½Ρ‹ Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ.
1. ΠžΡ‚ΠΊΡ€ΠΎΠΉΡ‚Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΉΠ½Ρ‹ΠΉ отсСк 5, оттянув ΠΊΡ€Ρ‹ΡˆΠΊΡƒ.
2. Π—Π°ΠΌΠ΅Π½ΠΈΡ‚Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ, ΡƒΠ±Π΅Π΄ΠΈΠ²ΡˆΠΈΡΡŒ, Ρ‡Ρ‚ΠΎ соблюдСна ΠΏΠΎΠ»ΡΡ€Π½ΠΎΡΡ‚ΡŒ Π²
соотвСтствии с символами Π² отсСкС.
3. Для Ρ‚ΠΎΠ³ΠΎ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΡƒΡΡ‚Π°Π½ΠΎΠ²ΠΈΡ‚ΡŒ
Π΄Π°Ρ‚Ρƒ ΠΈ врСмя, слСдуйтС ΠΏΡ€ΠΎΡ†Π΅-
Π΄ΡƒΡ€Π΅, описанной Π² Β«Π Π°Π·Π΄Π΅Π»Π΅ 1.Β».

Π’ памяти ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ всС значСния, Π½ΠΎ Π΄Π°Ρ‚Π° ΠΈ врСмя
Π±ΡƒΠ΄ΡƒΡ‚ ΡΠ±Ρ€ΠΎΡˆΠ΅Π½Ρ‹ – поэтому послС Π·Π°ΠΌΠ΅Π½Ρ‹ Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ Π³ΠΎΠ΄
автоматичСски Π·Π°ΠΌΠΈΠ³Π°Π΅Ρ‚.
Π­Π»Π΅ΠΌΠ΅Π½Ρ‚Ρ‹ питания ΠΈ ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€Π° Π·Π°ΠΌΠ΅Π½Ρ‹

ΠŸΠΎΠΆΠ°Π»ΡƒΠΉΡΡ‚Π°, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ 2 Π½ΠΎΠ²Ρ‹Π΅ Ρ‰Π΅Π»ΠΎΡ‡Π½Ρ‹Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ Π½Π°
1,5Π’ с Π΄Π»ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΌ сроком слуТбы Ρ€Π°Π·ΠΌΠ΅Ρ€Π° AAA.

НС ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ с ΠΈΡΡ‚Π΅ΠΊΡˆΠΈΠΌ сроком годности.

Π”ocΡ‚aΠ½ΡŒΡ‚Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ, Ссли ΠΏΡ€ΠΈΠ±ΠΎΡ€ Π½Π΅ Π±ΡƒΠ΄Π΅Ρ‚ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒΡΡ
Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ Π΄Π»ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΏΠ΅Ρ€ΠΈΠΎΠ΄Π° Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ.
ИспользованиС аккумуляторов
Π‘ ΠΏΡ€ΠΈΠ±ΠΎΡ€ΠΎΠΌ ΠΌΠΎΠΆΠ½ΠΎ Ρ€Π°Π±ΠΎΡ‚Π°Ρ‚ΡŒ, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡ аккумуляторныС Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ.

ΠŸΠΎΠΆΠ°Π»ΡƒΠΉΡΡ‚Π°, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ ΠΎΠ΄ΠΈΠ½ Ρ‚ΠΈΠΏ аккумуля-
Ρ‚ΠΎΡ€Π½Ρ‹Ρ… Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ Β«NiMHΒ».

Π‘Π°Ρ‚Π°Ρ€Π΅ΠΈ Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎ Π²Ρ‹Π½ΡƒΡ‚ΡŒ ΠΈ ΠΏΠ΅Ρ€Π΅Π·Π°Ρ€ΡΠ΄ΠΈΡ‚ΡŒ, Ссли появ-
ляСтся символ элСмСнтов питания (разряТСнная
батарСя). Они Π½Π΅ Π΄ΠΎΠ»ΠΆΠ½Ρ‹ ΠΎΡΡ‚Π°Π²Π°Ρ‚ΡŒΡΡ Π²Π½ΡƒΡ‚Ρ€ΠΈ ΠΏΡ€ΠΈΠ±ΠΎΡ€Π°,
ΠΏΠΎΡΠΊΠΎΠ»ΡŒΠΊΡƒ ΠΌΠΎΠ³ΡƒΡ‚ Π²Ρ‹ΠΉΡ‚ΠΈ ΠΈΠ· строя (Π΄Π°ΠΆΠ΅ Π² Π²Ρ‹ΠΊΠ»ΡŽΡ‡Π΅Π½Π½ΠΎΠΌ
ΠΏΡ€ΠΈΠ±ΠΎΡ€Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ ΠΏΡ€ΠΎΠ΄ΠΎΠ»ΠΆΠ°ΡŽΡ‚ Ρ€Π°Π·Ρ€ΡΠΆΠ°Ρ‚ΡŒΡΡ).

ВсСгда Π²Ρ‹Π½ΠΈΠΌΠ°ΠΉΡ‚Π΅ аккумуляторы, Ссли Π½Π΅ ΡΠΎΠ±ΠΈΡ€Π°Π΅Ρ‚Π΅ΡΡŒ
ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒΡΡ ΠΏΡ€ΠΈΠ±ΠΎΡ€ΠΎΠΌ Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ Π½Π΅Π΄Π΅Π»ΠΈ ΠΈΠ»ΠΈ Π±ΠΎΠ»Π΅Π΅!

Аккумуляторы НЕ ΠΌΠΎΠ³ΡƒΡ‚ Π·Π°Ρ€ΡΠΆΠ°Ρ‚ΡŒΡΡ Π² ΠΏΡ€ΠΈΠ±ΠΎΡ€Π΅! ΠŸΠΎΠ²Ρ‚ΠΎΡ€Π½ΠΎ заря-
Π΄ΠΈΡ‚Π΅ аккумуляторы Π²ΠΎ внСшнСм зарядном устройствС ΠΈ ΠΎΠ·Π½Π°-
ΠΊΠΎΠΌΡŒΡ‚Π΅ΡΡŒ с ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΠ΅ΠΉ ΠΏΠΎ зарядкС, ΡƒΡ…ΠΎΠ΄Ρƒ ΠΈ сроку слуТбы!
6. БообщСния ΠΎΠ± ΠΎΡˆΠΈΠ±ΠΊΠ°Ρ…
Если Π²ΠΎ врСмя измСрСния происходит ошибка, Ρ‚ΠΎ ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€Π°
измСрСния прСрываСтся ΠΈ выдаСтся сообщСниС ΠΎΠ± ошибкС,
Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€ Β«ERR 3Β».
Ошибка ОписаниС ВозмоТная ΠΏΡ€ΠΈΡ‡ΠΈΠ½Π° ΠΈ устранСниС
Β«
ERR 1
Β»
AN
Π‘ΠΈΠ³Π½Π°Π»
слишком
слабый
Π˜ΠΌΠΏΡƒΠ»ΡŒΡΠ½Ρ‹Π΅ сигналы Π½Π° ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π΅
слишком слабыС. ΠŸΠΎΠ²Ρ‚ΠΎΡ€Π½ΠΎ Π½Π°Π»ΠΎΠΆΠΈΡ‚Π΅
ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρƒ ΠΈ ΠΏΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅.*
Β«
ERR 2
Β»
AO
ΠžΡˆΠΈΠ±ΠΎΡ‡Π½Ρ‹
Π΅ сигналы
Π’ΠΎ врСмя измСрСния ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π° зафикси-
Ρ€ΠΎΠ²Π°Π»Π° ΠΎΡˆΠΈΠ±ΠΎΡ‡Π½Ρ‹Π΅ сигналы, Π²Ρ‹Π·Π²Π°Π½Π½Ρ‹Π΅,
Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, Π΄Π²ΠΈΠΆΠ΅Π½ΠΈΠ΅ΠΌ ΠΈΠ»ΠΈ сокращСниСм
ΠΌΡ‹ΡˆΡ†. ΠŸΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅, Π΄Π΅Ρ€ΠΆΠ°
Ρ€ΡƒΠΊΡƒ Π½Π΅ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎ.
15BP W3 Comfort
RU
* ΠŸΠΎΠΆΠ°Π»ΡƒΠΉΡΡ‚Π°, Π½Π΅ΠΌΠ΅Π΄Π»Π΅Π½Π½ΠΎ ΠΏΡ€ΠΎΠΊΠΎΠ½ΡΡƒΠ»ΡŒΡ‚ΠΈΡ€ΡƒΠΉΡ‚Π΅ΡΡŒ с Π²Ρ€Π°Ρ‡ΠΎΠΌ, Ссли
эта ΠΈΠ»ΠΈ какая-Π»ΠΈΠ±ΠΎ другая ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΠ° Π²ΠΎΠ·Π½ΠΈΠΊΠ°Π΅Ρ‚ ΠΏΠΎΠ²Ρ‚ΠΎΡ€Π½ΠΎ.

Если Π’Π°ΠΌ каТСтся, Ρ‡Ρ‚ΠΎ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ ΠΎΡ‚Π»ΠΈΡ‡Π°ΡŽΡ‚ΡΡ ΠΎΡ‚
ΠΎΠ±Ρ‹Ρ‡Π½Ρ‹Ρ…, Ρ‚ΠΎ, поТалуйста, Π²Π½ΠΈΠΌΠ°Ρ‚Π΅Π»ΡŒΠ½ΠΎ ΠΏΡ€ΠΎΡ‡Ρ‚ΠΈΡ‚Π΅ ΠΈΠ½Ρ„ΠΎΡ€-
ΠΌΠ°Ρ†ΠΈΡŽ Π² Β«Π Π°Π·Π΄Π΅Π»Π΅ 1.Β».
7. Π’Π΅Ρ…Π½ΠΈΠΊΠ° бСзопасности, ΡƒΡ…ΠΎΠ΄, ΠΏΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° точности ΠΈ
утилизация

Π’Π΅Ρ…Π½ΠΈΠΊΠ° бСзопасности ΠΈ Π·Π°Ρ‰ΠΈΡ‚Π°
β€’ Π‘Π»Π΅Π΄ΡƒΠΉΡ‚Π΅ инструкциям ΠΏΠΎ использованию. Π’ этом Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Π΅
содСрТатся Π²Π°ΠΆΠ½Ρ‹Π΅ свСдСния ΠΎ Ρ€Π°Π±ΠΎΡ‚Π΅ ΠΈ бСзопасности этого
устройства. ΠŸΠ΅Ρ€Π΅Π΄ использованиСм устройства, поТалуйста,
Π²Π½ΠΈΠΌΠ°Ρ‚Π΅Π»ΡŒΠ½ΠΎ ΠΏΡ€ΠΎΡ‡ΠΈΡ‚Π°ΠΉΡ‚Π΅ этот Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚ ΠΈ сохранитС Π΅Π³ΠΎ для
дальнСйшСго использования.
β€’ ΠŸΡ€ΠΈΠ±ΠΎΡ€ ΠΌΠΎΠΆΠ΅Ρ‚ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒΡΡ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ Π² цСлях, описанных Π²
Π΄Π°Π½Π½ΠΎΠΉ инструкции. Π˜Π·Π³ΠΎΡ‚ΠΎΠ²ΠΈΡ‚Π΅Π»ΡŒ Π½Π΅ нСсСт отвСтствСнности
Π·Π° поврСТдСния,
Π²Ρ‹Π·Π²Π°Π½Π½Ρ‹Π΅ Π½Π΅ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½Ρ‹ΠΌ использованиСм.
β€’ Π’ состав ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° входят Ρ‡ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Ρ‹, Ρ‚Ρ€Π΅Π±Ρƒ-
ΡŽΡ‰ΠΈΠ΅ остороТного обращСния. ΠžΠ·Π½Π°ΠΊΠΎΠΌΡŒΡ‚Π΅ΡΡŒ с условиями
хранСния ΠΈ эксплуатации, описанными Π² Ρ€Π°Π·Π΄Π΅Π»Π΅ Β«Π’Π΅Ρ…Π½ΠΈΡ‡Π΅-
скиС характСристики»!
β€’ ΠžΠ±Π΅Ρ€Π΅Π³Π°ΠΉΡ‚Π΅ ΠΏΡ€ΠΈΠ±ΠΎΡ€ ΠΎΡ‚:
- Π²ΠΎΠ΄Ρ‹ ΠΈ Π²Π»Π°Π³ΠΈ
- ΡΠΊΡΡ‚Ρ€Π΅ΠΌΠ°Π»ΡŒΠ½Ρ‹Ρ… Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€
- ΡƒΠ΄Π°Ρ€ΠΎΠ² ΠΈ ΠΏΠ°Π΄Π΅Π½ΠΈΠΉ
- загрязнСния ΠΈ ΠΏΡ‹Π»ΠΈ
Β«
ERR 3
Β»
AO
ΠžΡ‚ΡΡƒΡ‚ΡΡ‚-
Π²ΡƒΠ΅Ρ‚
Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ Π²
ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π΅
ΠœΠ°Π½ΠΆΠ΅Ρ‚Π° Π½Π΅ ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ Π½Π°ΠΊΠ°Ρ‡Π°Π½Π° Π΄ΠΎ
Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎΠ³ΠΎ уровня давлСния.
Π’ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎ, ΠΈΠΌΠ΅Π΅Ρ‚ мСсто ΡƒΡ‚Π΅Ρ‡ΠΊΠ°.
ΠŸΡ€ΠΎΠ²Π΅Ρ€ΡŒΡ‚Π΅, Ρ‡Ρ‚ΠΎ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π° подсоСдинСна
ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½ΠΎ ΠΈ Π½Π΅ слишком свободна. ΠŸΡ€ΠΈ
нСобходимости Π·Π°ΠΌΠ΅Π½ΠΈΡ‚Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ.
ΠŸΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅.
Β«
ERR 5
Β» ΠžΡˆΠΈΠ±ΠΎΡ‡Π½Ρ‹
ΠΉ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚
(Π°Ρ€Ρ‚Π΅Ρ„Π°ΠΊΡ‚)
Π‘ΠΈΠ³Π½Π°Π»Ρ‹ измСрСния Π½Π΅Ρ‚ΠΎΡ‡Π½Ρ‹, ΠΈΠ·-Π·Π° Ρ‡Π΅Π³ΠΎ
ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠ΅ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² Π½Π΅Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎ.
ΠŸΡ€ΠΎΡ‡Ρ‚ΠΈΡ‚Π΅ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°Ρ†ΠΈΠΈ для получСния
Π½Π°Π΄Π΅ΠΆΠ½Ρ‹Ρ… Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΈ
Π·Π°Ρ‚Π΅ΠΌ ΠΏΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅.*
Β«
HI
Β»
ΠŸΡƒΠ»ΡŒΡ ΠΈΠ»ΠΈ
Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹
слишком
высоки
Π”Π°Π²Π»Π΅Π½ΠΈΠ΅ Π² ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π΅ слишком высокоС
(ΡΠ²Ρ‹ΡˆΠ΅ 299 ΠΌΠΌ Ρ€Ρ‚. ст.) Π˜Π›Π˜ ΠΏΡƒΠ»ΡŒΡ
слишком высокий (ΡΠ²Ρ‹ΡˆΠ΅ 200 ΡƒΠ΄Π°Ρ€ΠΎΠ² Π²
ΠΌΠΈΠ½ΡƒΡ‚Ρƒ). ΠžΡ‚Π΄ΠΎΡ…Π½ΠΈΡ‚Π΅ Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ 5 ΠΌΠΈΠ½ΡƒΡ‚ ΠΈ
ΠΏΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅.*
Β«
LO
Β»
ΠŸΡƒΠ»ΡŒΡ
слишком
Π½ΠΈΠ·ΠΊΠΈΠΉ
ΠŸΡƒΠ»ΡŒΡ слишком Π½ΠΈΠ·ΠΊΠΈΠΉ (ΠΌΠ΅Π½Π΅Π΅ 40 ΡƒΠ΄Π°Ρ€ΠΎΠ²
Π² ΠΌΠΈΠ½ΡƒΡ‚Ρƒ). ΠŸΠΎΠ²Ρ‚ΠΎΡ€ΠΈΡ‚Π΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅.*
Ошибка ОписаниС ВозмоТная ΠΏΡ€ΠΈΡ‡ΠΈΠ½Π° ΠΈ устранСниС
16
- прямых солнСчных Π»ΡƒΡ‡Π΅ΠΉ
- ΠΆΠ°Ρ€Ρ‹ ΠΈ Ρ…ΠΎΠ»ΠΎΠ΄Π°
β€’ ΠœΠ°Π½ΠΆΠ΅Ρ‚Ρ‹ ΠΏΡ€Π΅Π΄ΡΡ‚Π°Π²Π»ΡΡŽΡ‚ собой Ρ‡ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ элСмСнты,
Ρ‚Ρ€Π΅Π±ΡƒΡŽΡ‰ΠΈΠ΅ Π±Π΅Ρ€Π΅ΠΆΠ½ΠΎΠ³ΠΎ обращСния.
β€’ ΠŸΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅ Π½Π°ΠΊΠ°Ρ‡ΠΊΡƒ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ Π½Π°Π»ΠΎΠΆΠ΅Π½Π½ΠΎΠΉ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹.
β€’ НС ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ устройство Π²Π±Π»ΠΈΠ·ΠΈ источников ΡΠΈΠ»ΡŒΠ½Ρ‹Ρ… элСк-
Ρ‚Ρ€ΠΎΠΌΠ°Π³Π½ΠΈΡ‚Π½Ρ‹Ρ… ΠΏΠΎΠ»Π΅ΠΉ, Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€ рядом с ΠΌΠΎΠ±ΠΈΠ»ΡŒΠ½Ρ‹ΠΌΠΈ Ρ‚Π΅Π»Π΅Ρ„ΠΎ-
Π½Π°ΠΌΠΈ ΠΈΠ»ΠΈ радиостанциями. Π’ΠΎ врСмя использования устрой-
ства минимальноС расстояниС ΠΎΡ‚ источников Ρ‚Π°ΠΊΠΈΡ… ΠΏΠΎΠ»Π΅ΠΉ
Π΄ΠΎΠ»ΠΆΠ½ΠΎ ΡΠΎΡΡ‚Π°Π²Π»ΡΡ‚ΡŒ
3,3 ΠΌ.
β€’ НС ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ ΠΏΡ€ΠΈΠ±ΠΎΡ€, Ссли Π²Π°ΠΌ каТСтся, Ρ‡Ρ‚ΠΎ ΠΎΠ½ ΠΏΠΎΠ²Ρ€Π΅ΠΆΠ΄Π΅Π½,
ΠΈΠ»ΠΈ Ссли Π²Ρ‹ Π·Π°ΠΌΠ΅Ρ‚ΠΈΠ»ΠΈ Ρ‡Ρ‚ΠΎ-Π»ΠΈΠ±ΠΎ Π½Π΅ΠΎΠ±Ρ‹Ρ‡Π½ΠΎΠ΅.
β€’ Никогда Π½Π΅ вскрывайтС ΠΏΡ€ΠΈΠ±ΠΎΡ€.
β€’ Если ΠΏΡ€ΠΈΠ±ΠΎΡ€ Π½Π΅ Π±ΡƒΠ΄Π΅Ρ‚ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒΡΡ Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ Π΄Π»ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ
ΠΏΠ΅Ρ€ΠΈΠΎΠ΄Π° Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ, Ρ‚ΠΎ ΠΈΠ· Π½Π΅Π³ΠΎ слСдуСт Π²Ρ‹Π½ΡƒΡ‚ΡŒ Π±Π°Ρ‚Π°Ρ€Π΅ΠΉΠΊΠΈ.
β€’ ΠŸΡ€ΠΎΡ‡Ρ‚ΠΈΡ‚Π΅ дальнСйшиС указания ΠΏΠΎ бСзопасности Π² ΠΎΡ‚Π΄Π΅Π»ΡŒΠ½Ρ‹Ρ…
Ρ€Π°Π·Π΄Π΅Π»Π°Ρ… этой инструкции.
β€’ Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹
измСрСния, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ прСдоставляСт этот ΠΏΡ€ΠΈΠ±ΠΎΡ€,
Π½Π΅ ΡΠ²Π»ΡΡŽΡ‚ΡΡ Π΄ΠΈΠ°Π³Π½ΠΎΠ·ΠΎΠΌ. Они Π½Π΅ Π·Π°ΠΌΠ΅Π½ΡΡŽΡ‚ Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ
ΠΊΠΎΠ½ΡΡƒΠ»ΡŒΡ‚Π°Ρ†ΠΈΠΈ Π²Ρ€Π°Ρ‡Π°, особСнно Ссли ΠΎΠ½ΠΈ Π½Π΅ ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‚
симптомам ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°. НС ΠΏΠΎΠ»Π°Π³Π°ΠΉΡ‚Π΅ΡΡŒ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ Π½Π° Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚
измСрСния, всСгда рассматривайтС Π΄Ρ€ΡƒΠ³ΠΈΠ΅ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Π΅
симптомы ΠΈ ΠΆΠ°Π»ΠΎΠ±Ρ‹ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°. ΠžΠ±Ρ€Π°Ρ‚ΠΈΡ‚Π΅ΡΡŒ ΠΊ Π²Ρ€Π°Ρ‡Ρƒ ΠΈΠ»ΠΈ Π²Ρ‹Π·ΠΎ-
Π²ΠΈΡ‚Π΅ ΡΠΊΠΎΡ€ΡƒΡŽ Π² случаС нСобходимости.
ΠŸΠΎΠ·Π°Π±ΠΎΡ‚ΡŒΡ‚Π΅ΡΡŒ ΠΎ Ρ‚ΠΎΠΌ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ Π΄Π΅Ρ‚ΠΈ Π½Π΅ ΠΌΠΎΠ³Π»ΠΈ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒ
ΠΏΡ€ΠΈΠ±ΠΎΡ€ Π±Π΅Π· присмотра, ΠΏΠΎΡΠΊΠΎΠ»ΡŒΠΊΡƒ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ Π΅Π³ΠΎ ΠΌΠ΅Π»ΠΊΠΈΠ΅
части ΠΌΠΎΠ³ΡƒΡ‚ Π±Ρ‹Ρ‚ΡŒ ΠΏΡ€ΠΎΠ³Π»ΠΎΡ‡Π΅Π½Ρ‹. ΠŸΡ€ΠΈ поставкС ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° с
кабСлями ΠΈ шлангами Π²ΠΎΠ·ΠΌΠΎΠΆΠ΅Π½ риск ΡƒΠ΄ΡƒΡˆΠ΅Π½ΠΈΡ.
Π£Ρ…ΠΎΠ΄ Π·Π° ΠΏΡ€ΠΈΠ±ΠΎΡ€ΠΎΠΌ
Π˜ΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠΉΡ‚Π΅ для чистки ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° Ρ‚ΠΎΠ»ΡŒΠΊΠΎ ΡΡƒΡ…ΡƒΡŽ, ΠΌΡΠ³ΠΊΡƒΡŽ Ρ‚ΠΊΠ°Π½ΡŒ.
ΠžΡ‡ΠΈΡΡ‚ΠΊΠ° ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹
ΠžΡΡ‚ΠΎΡ€ΠΎΠΆΠ½ΠΎ ΡƒΠ΄Π°Π»ΠΈΡ‚Π΅ всС слСды с ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹ ΠΏΡ€ΠΈ ΠΏΠΎΠΌΠΎΡ‰ΠΈ Π²Π»Π°ΠΆΠ½ΠΎΠΉ
Ρ‚ΠΊΠ°Π½ΠΈ
ΠΈ мягкого ΠΌΠΎΡŽΡ‰Π΅Π³ΠΎ срСдства.
ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° точности
ΠœΡ‹ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½Π΄ΡƒΠ΅ΠΌ ΠΏΡ€ΠΎΠ²Π΅Ρ€ΡΡ‚ΡŒ Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ ΠΏΡ€ΠΈΠ±ΠΎΡ€Π° ΠΊΠ°ΠΆΠ΄Ρ‹Π΅ 2 Π³ΠΎΠ΄Π°
Π»ΠΈΠ±ΠΎ послС мСханичСского воздСйствия (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, падСния).
Для провСдСния тСста ΠΎΠ±Ρ€Π°Ρ‚ΠΈΡ‚Π΅ΡΡŒ Π² мСстный сСрвисный Ρ†Π΅Π½Ρ‚Ρ€
Microlife (см. ввСдСниС).
Утилизация
Π‘Π°Ρ‚Π°Ρ€Π΅ΠΈ ΠΈ элСктронныС ΠΏΡ€ΠΈΠ±ΠΎΡ€Ρ‹ слСдуСт ΡƒΡ‚ΠΈΠ»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ Π²
соотвСтствии с принятыми Π½ΠΎΡ€ΠΌΠ°ΠΌΠΈ ΠΈ Π½Π΅ Π²Ρ‹Π±Ρ€Π°ΡΡ‹Π²Π°Ρ‚ΡŒ
вмСстС с Π±Ρ‹Ρ‚ΠΎΠ²Ρ‹ΠΌΠΈ ΠΎΡ‚Ρ…ΠΎΠ΄Π°ΠΌΠΈ.
8. Гарантия
На ΠΏΡ€ΠΈΠ±ΠΎΡ€ распространяСтся гарантия Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ 5 Π»Π΅Ρ‚ с Π΄Π°Ρ‚Ρ‹
приобрСтСния. Гарантия Π΄Π΅ΠΉΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½Π° Ρ‚ΠΎΠ»ΡŒΠΊΠΎ ΠΏΡ€ΠΈ Π½Π°Π»ΠΈΡ‡ΠΈΠΈ
Π³Π°Ρ€Π°Π½Ρ‚ΠΈΠΉΠ½ΠΎΠ³ΠΎ Ρ‚Π°Π»ΠΎΠ½Π°, Π·Π°ΠΏΠΎΠ»Π½Π΅Π½Π½ΠΎΠ³ΠΎ Π΄ΠΈΠ»Π΅Ρ€ΠΎΠΌ (см. с ΠΎΠ±Ρ€Π°Ρ‚Π½ΠΎΠΉ
стороны), ΠΏΠΎΠ΄Ρ‚Π²Π΅Ρ€ΠΆΠ΄Π°ΡŽΡ‰Π΅Π³ΠΎ Π΄Π°Ρ‚Ρƒ ΠΏΡ€ΠΎΠ΄Π°ΠΆΠΈ, ΠΈΠ»ΠΈ кассового Ρ‡Π΅ΠΊΠ°.
17BP W3 Comfort
RU
β€’ Гарантия Π½Π΅ распространяСтся Π½Π° Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ, ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρƒ ΠΈ ΠΈΠ·Π½Π°-
ΡˆΠΈΠ²Π°Π΅ΠΌΡ‹Π΅ части.
β€’ ВскрытиС ΠΈ мСханичСскиС поврСТдСния приводят ΠΊ ΡƒΡ‚Ρ€Π°Ρ‚Π΅
Π³Π°Ρ€Π°Π½Ρ‚ΠΈΠΈ.
β€’
Гарантия Π½Π΅ распространяСтся Π½Π° поврСТдСния, Π²Ρ‹Π·Π²Π°Π½Π½Ρ‹Π΅ Π½Π΅ΠΏΡ€Π°-
Π²ΠΈΠ»ΡŒΠ½Ρ‹ΠΌ ΠΎΠ±Ρ€Π°Ρ‰Π΅Π½ΠΈΠ΅ΠΌ, Ρ€Π°Π·Ρ€ΡΠ΄ΠΈΠ²ΡˆΠΈΠΌΠΈΡΡ батарСями, нСсчастными
случаями ΠΈΠ»ΠΈ Π½Π΅Π²Ρ‹ΠΏΠΎΠ»Π½Π΅Π½ΠΈΠ΅ΠΌ инструкций ΠΏΠΎ эксплуатации.
ΠŸΠΎΠΆΠ°Π»ΡƒΠΉΡΡ‚Π°, ΠΎΠ±Ρ€Π°Ρ‚ΠΈΡ‚Π΅ΡΡŒ Π² мСстный сСрвисный Ρ†Π΅Π½Ρ‚Ρ€ Microlife
(см. ввСдСниС).
9. ВСхничСскиС характСристики
Π”Π°Π½Π½Ρ‹ΠΉ ΠΏΡ€ΠΈΠ±ΠΎΡ€ соотвСтствуСт трСбованиям Π΄ΠΈΡ€Π΅ΠΊΡ‚ΠΈΠ²Ρ‹ Π•Π‘ ΠΎ
мСдицинском ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΠΈ 93/42/EEC.
ΠŸΡ€Π°Π²ΠΎ Π½Π° внСсСниС тСхничСских ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΠΉ сохраняСтся Π·Π°
ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ.
Условия
примСнСния:
ΠΎΡ‚ 10 Π΄ΠΎ 40 Β°C
максимальная ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ Π²Π»Π°ΠΆ-
Π½ΠΎΡΡ‚ΡŒ 15 - 95 %
Условия хранСния: ΠΎΡ‚ -20 Π΄ΠΎ +55 Β°C
максимальная ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ Π²Π»Π°ΠΆ-
Π½ΠΎΡΡ‚ΡŒ 15 - 95 %
Масса: 112Π³ (Π²ΠΊΠ»ΡŽΡ‡Π°Ρ Π±Π°Ρ‚Π°Ρ€Π΅ΠΉΠΊΠΈ)
Π Π°Π·ΠΌΠ΅Ρ€Ρ‹: 98 x 131 x 51,5 ΠΌΠΌ
Π Π°Π·ΠΌΠ΅Ρ€ ΠΌΠ°Π½ΠΆΠ΅Ρ‚Ρ‹: 13,5 - 23 см (5,25 - 9,05 дюймов)
ΠŸΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€Π° ΠΈΠ·ΠΌΠ΅-
рСния:
осцилломСтричСская, Π² соотвСтствии с
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠΌ ΠšΠΎΡ€ΠΎΡ‚ΠΊΠΎΠ²Π°: Ρ„Π°Π·Π° I систоличС-
ская, Ρ„Π°Π·Π° V диастоличСская
Π”ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ:
20 - 280 ΠΌΠΌ Ρ€Ρ‚. ст. – Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½ΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
40 - 200 ΡƒΠ΄Π°Ρ€ΠΎΠ² Π² ΠΌΠΈΠ½ΡƒΡ‚Ρƒ – ΠΏΡƒΠ»ΡŒΡ
Π˜Π½Π΄ΠΈΠΊΠ°Ρ†ΠΈΡ давлСния
Π² ΠΌΠ°Π½ΠΆΠ΅Ρ‚Π΅: 0 - 299 ΠΌΠΌ Ρ€Ρ‚.ст.
ΠœΠΈΠ½ΠΈΠΌΠ°Π»ΡŒΠ½Ρ‹ΠΉ шаг
ΠΈΠ½Π΄ΠΈΠΊΠ°Ρ†ΠΈΠΈ: 1 ΠΌΠΌ Ρ€Ρ‚.ст.
БтатичСская
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ: Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ Π² ΠΏΡ€Π΅Π΄Π΅Π»Π°Ρ… Β± 3 ΠΌΠΌ Ρ€Ρ‚. ст.
Π’ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ измСрСния
ΠΏΡƒΠ»ΡŒΡΠ°: Β±5 % считанного значСния
Π˜ΡΡ‚ΠΎΡ‡Π½ΠΈΠΊ питания: 2 x 1,5Π’ Ρ‰Π΅Π»ΠΎΡ‡Π½Ρ‹Π΅ Π±Π°Ρ‚Π°Ρ€Π΅ΠΉΠΊΠΈ Ρ€Π°Π·ΠΌΠ΅Ρ€Π°
AAA
Π‘Ρ€ΠΎΠΊ слуТбы
Π±Π°Ρ‚Π°Ρ€Π΅ΠΈ:
ΠΏΡ€ΠΈΠΌΠ΅Ρ€Π½ΠΎ 320 ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ (ΠΏΡ€ΠΈ исполь-
Π·ΠΎΠ²Π°Π½ΠΈΠΈ Π½ΠΎΠ²Ρ‹Ρ… Ρ‰Π΅Π»ΠΎΡ‡Π½Ρ‹Ρ… Π±Π°Ρ‚Π°Ρ€Π΅ΠΉ)
Класс Π·Π°Ρ‰ΠΈΡ‚Ρ‹
: IP20
БоотвСтствиС стан-
Π΄Π°Ρ€Ρ‚Π°ΠΌ:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
ΠžΠΆΠΈΠ΄Π°Π΅ΠΌΡ‹ΠΉ срок-
слуТбы:
ΠŸΡ€ΠΈΠ±ΠΎΡ€: 5 Π»Π΅Ρ‚ ΠΈΠ»ΠΈ 10000 ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ
ΠšΠΎΠΌΠΏΠ»Π΅ΠΊΡ‚ΡƒΡŽΡ‰ΠΈΠ΅: 2 Π³ΠΎΠ΄Π°
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

Microlife BP W3 Comfort User manual

Category
Blood pressure units
Type
User manual

Microlife BP W3 Comfort is an easy-to-use wrist blood pressure monitor that provides accurate and reliable measurements. It features a cuff fit check indicator to ensure proper placement, and an arrhythmia indicator to detect irregular heartbeats. The device stores up to 30 measurements, and calculates the average of all stored values. It also comes with a large, easy-to-read display and a low battery indicator.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI