Hotblast 1400 Owner's manual

Category
Wood stove
Type
Owner's manual

This manual is also suitable for

UNITED STATES STOVE COMPANY
227 Industrial Park Road
P.O.Box 151
South Pittsburg, TN 37380
800-750-2723
www.USSTOVE.com
Models 1300/1400/1500
OWNER'S MANUAL
SOLID FUEL
WARM AIR FURNACE
FOR PARALLEL INSTALLATION WITH EXISTING FORCED AIR-GAS OR OIL FIRED FUR-
NACE (U.S. ONLY)
FOR INSTALLATION AS A CENTRAL FURNACE
THE 1500 HOTBLAST FURNACE HAS BEEN APPROVED FOR
U.S. INSTALLATIONS ONLY.
ALL MODELS CERTIFIED UNDER UL 391
MODELS 1300/1400 ARE ALSO CERTIFIED UNDER CAN/CSA-B366.1-M91
MODEL 1400 IS WOOD ONLY
851486 K-1905E
CAUTION:
READ ALL INSTRUCTIONS CARE-
FULLY BEFORE STARTING THE
INSTALLATION OR OPERATING
THE FURNACE
IMPROPER INSTALLATION MAY
VOID YOUR WARRANTY
DO NOT USE THIS FURNACE
IN A MOBILE HOME OR TRAILER
U.S. Environmental Protection Agency
Certied to comply with 2015 particulate emissions standards.
2
NOTE: YOUR UNIT MUST BE INSTALLED BY A
QUALIFIED FURNACE INSTALLER.
You've purchased one of America's Finest Wood and Coal Burning Furnaces. By heat-
ing with wood and coal you're helping CONSERVE AMERICA'S ENERGY! Wood is
our Renewable Energy Resource. Please do your part to preserve our wood supply.
Plant at least one tree each year. Future generations will thank you.
CONGRATULATIONS!
TOOLS
Pencil
6 Foot Folding Rule or Tape
Tin Snips
Drill, Hand or Electric
Drill Bit- 1/8" Dia.
(For Sheet Metal Screws)
Screw Driver (Blade-Type)
Gloves
Sabre Saw
5/16" Nut Driver or
5/16" Socket w/Ratchet
Safety Glasses
MATERIAL
6" Pipe, 6" Elbow, Collar and Thimble;
as required (24 gauge min.)
1/2" Sheet Metal Screws
6" Inside diameter Listed Residential
Type or Building Heating Appliance
Chimney or existing masonry chimney
Electrical Wiring
6" Draft Regulator
1/2" Conduit (Conduit Connectors)
Furnace Cement (Manufacturer
Recommends: Rutland Black-Code 78
or Equivalent)
Plenum and Duct work as required.
TOOLS AND MATERIALS NEEDED
3
Caution Labels
Caution Labels
Your Furnace has the following labels. Read and Obey all labels.
DANGER: RISK OF FIRE OR EXPLOSION.
DO NOT burn garbage, gasoline, drain oil, or other ammable liquids.
WARNING: FIRE HAZARD.
DO NOT operate with re draft exceeding .06 inches w.c.
DO NOT operate with fuel loading or ash removal doors open.
DO NOT store fuels, paints, thinners, ammable liquids, or other highly volatile sub-
stances in the furnace room.
CAUTION:
HOT SURFACES! Keep children away. Do not touch during operation.
SAFETY NOTICE:
If this heater is not properly installed, a house re may result. For your
safety, follow the installation directions. Contact local building or re of-
cials about restrictions and installation inspection requirements in your
area. If not already installed, we recommend that smoke detectors be
installed.
CAUTION!
CLEANOUT OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY, AND
DRAFT INDUCER (IF USED), IS ESPECIALLY IMPORTANT AT THE END
OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE
SUMMER MONTHS, CAUSED BY ACCUMULATED ASH.
CAUTION!
INSPECT FLUE PIPES, FLUE PIPE JOINTS AND FLUE PIPE SEALS
REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE NOT
DRAWN INTO, AND CIRCULATED BY, THE AIR CIRCULATION SYSTEM.
4
Rules for safe installation and operation
Read these rules and the instructions carefully. Failure to follow them will cause a
hazard that could result in death, serious bodily injury, and/or property damage.
Your Furnace is designed to be installed in a parallel air ow arrangement with a gas or oil-
red forced air up ow-type central furnace, or it may be installed as a central furnace.
1. Check your local codes. The installation must comply
with their rulings.
2. Do not install this furnace in a mobile home or trailer.
3. Always connect this furnace to a chimney and vent to
the outside. Never vent to another room or inside a
building.
4. Do not connect this furnace to an aluminum Type B gas
vent. This is not safe and is prohibited by the National
Fire Protection Association Code. This furnace requires
a masonry or Listed Factory Built Chimney for residential
type or Building Heating Appliance Chimney. Use a 6"
diameter chimney or larger, that is high enough to give
a good draft.
5. Be sure that if a masonry chimney is used, it is safely
constructed and in good repair. Have the chimney
inspected by the Fire Department or an inspector.
6. Inspect chimney connector and chimney before and
frequently during the heating season for any deposit
of creosote or soot which must be removed.
7. Provide air for combustion into the room where the fur-
nace is located. If the intake is not in the same room,
air must have free access to the room.
8. CAST IRON PARTS MUST BE "SEASONED" TO AVOID
CRACKING, BUILD ONLY SMALL FIRES ON FIRST
USE.
9. To prevent injury, do not allow anyone to use this fur-
nace who is unfamiliar with the correct operation of the
furnace.
10. For further information on using your furnace safely,
obtain a copy of the National Fire Protection Association
(NFPA) publication "Chimney's, Fireplaces and Solid
Fuel Burning Appliances" NFPA 211. The address of
the NFPA is Batterymarch Park, Quincy, MA 02269.
11. Keep the ashpit section free of excess ashes. Do not
allow ashes to stack higher than the sides of the ash
pan.
12. DISPOSAL OF ASHES- Place ashes in a metal container
with a tight tting lid. Keep the closed container on a
noncombustible oor or on the ground, well away from
all combustible materials. Keep the ashes in the closed
container until all cinders have thoroughly cooled. The
ashes may be buried in the ground or picked up by a
refuse collector.
13. CAUTION- The special paints used on your furnace
may give off some smoke while they are curing dur-
ing rst few res., Build small res at rst. The metal
used in construction of the furnace and duct work has
a light coating of oil. This could give off smoke and/or
odor from registers when furnace is used for the rst
time. This should disappear after a short period of time.
Once this burn-off has occurred, it should not reoccur.
14. CARING FOR PAINTED PARTS- This furnace has a
painted outside jacket, which is durable, but it will not
stand rough handling or abuse. When installing your
furnace, use care in handling. Clean with soap and
warm water when furnace in not hot. DO NOT use
any acids or scouring soap, as these wear and dull
the nish. DISCOLORATION WILL OCCUR IF THE
FURNACE IS OVERHEATED. FOLLOW OPERATING
INSTRUCTIONS CAREFULLY.
15. Keep the feed and ash doors closed at all times except
while tending the furnace.
CAUTION
DO NOT OPERATE WITH THE FEED AND/OR ASH
DOOR OPEN. THIS FURNACE IS DESIGNED FOR
THERMOSTATIC OPERATION. OPERATION WITH
ANY OF THESE DOORS OPEN WILL OVERHEAT
AND DAMAGE THE FURNACE.
WARNING
NEVER STORE FLAMMABLE LIQUIDS, ESPECIALLY
GASOLINE, IN THE VICINITY OF THE FURNACE.
CAUTION
GASES THAT ARE DRIVEN FROM FRESH COAL
MUST BE BURNED OR THEY WILL ACCUMULATE
AND EXPLODE. NEVER SMOTHER A FIRE WHEN
ADDING FRESH COAL.
CAUTION
NEVER USE GASOLINE, GASOLINE-TYPE LAN-
TERN FUEL, KEROSENE, CHARCOAL LIGHTER
FLUID, OR FLAMMABLE LIQUIDS TO START OR
"FRESHEN UP" A FIRE IN THE FURNACE.
5
Your HOTBLAST Furnace is designed to be a supplemental
or central heating source for your home. This Solid Fuel
Furnace may be installed in conjunction with a properly oper-
ating central furnace that is listed or certi ed in accordance
with nationally recognized safety standards and equipped
with the required controls and other safety features and
which has been installed in accordance with appropriate
standards of the National Fire Protection Association with
installation clearances speci ed in the furnace nameplate
marking. The installation must be accomplished by a quali ed
agency (one who is engaged in, and is responsible for, or is
thoroughly familiar with the installation and operation of the
gas, oil, and solid fuel burning heating appliances, who is
experienced in such work, familiar with all the requirements
of the authority having jurisdiction.) The installation shall
be in strict accordance with the manufacturer's installation
instructions furnished with the solid fuel furnace.
The chimney connector of the furnace is to be installed to
provide clearances to combustible material not less than
speci ed in the individual classi cations and marked on the
furnace. The chimney connector must be connected to a
chimney suitable for use with residential type or building
heating appliances which burn solid fuel.
The Furnace is designed to operate in either parallel or
series air ow arrangement with the central furnace or as
a central furnace.
CENTRAL FURNACE INSTALLATION
As a central furnace, the unit functions independently of any
other system. The blower will come on when the plenum
temperature reaches the setting on the blower control.
PARALLEL INSTALLATION (U.S. ONLY)
The design is such that when the blower comes on, the blower
on the central system also comes on. The blower will only
come on when the temperature in the plenum has reached
the setting on the blower control. This is to insure that there
is suf cient warm air in the system to make it ef cient for
the unit to operate. When the central system thermostat
calls for heat, the central system will operate by the burner
igniting and the blower coming on. It is possible that both
systems will operate simultaneously. It is recommended
that for the most ef cient use of your HOTBLAST Furnace,
that it be red as much as possible in order to reduce the
demand on your existing central heating system. This unit
has an optional forced draft kit that operates from a wall
thermostat. When the temperature falls below the setting
on the wall thermostat, the forced draft will come on (U.S.
Stove Option 11/DIKL)
The warm air supply outlet of the HOTBLAST Furnace
shall not be connected to the cold air return of the central
furnace, because the possibility exists of components of the
central furnace overheating and causing the central furnace
to operate other than is intended.
SERIES INSTALLATION
This type of installation uses only the blowers of the existing
central furnace. The solid fuel fan/limit control must also
control the functions of the existing furnace. All electrical
power must come from a single branch circuit.
HOW THE FURNACE FUNCTIONS
6
DIMENSIONS OF FURNACE
Figure 2
Models 1400/1500
Figure 1
Model 1300
7
LOCATING THE FURNACE
1. The furnace should be located in the same room as the
central system and as close as possible, but not closer
than 9". There should be no wall between the furnace
and the warm air outlet duct that is connected directly
to the warm air outlet plenum of the central furnace.
(See Fig. 4)
2. Place the furnace on a noncombustible oor.
3. Check gures 3 through 5. Be sure you have the clear-
ances shown below from the furnace and the connector
pipe to combustible surfaces. If you have a solid brick
or stone wall behind your furnace, you can place the
furnace as close as you wish to the wall. If the wall is
only faced with brick or stone, treat it as a combustible
wall.
18"
18"
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
NON-COMBUSTIBLE FLOOR
12"
9"
48"
18"
CENTRAL
FURNACE
6" CHIMNEY
21"
Figure 4
Figure 5
1300 1400 1500
Unit to Sidewall 12"
(305mm) 12"
(305mm) 12"
(305mm)
Unit to Backwall 30"
(760mm) 30"
(760mm) 30"
(760mm)
Front of Unit to
Combustible 48"
(1.22m) 48"
(1.22m) 48"
(1.22m)
Chimney Pipe
to Sidewall 18"
(460mm) 18"
(460mm) 21"
(530mm)
Chimney Pipe
to Backwall 18"
(460mm) 18"
(460mm) 18"
(460mm)
Plenum to
Combustibles 6"
(150mm) 6"
(150mm) 6"
(150mm)
2" MIN. AIR SPACE
REQUIRED BY CODE
CENTRAL
FURNACE
6" MIN.
PLENUM
TO
CEILING
Figure 3
8
10'
2' MIN.
3' MIN.
6" CHIMNEY CONNECTOR
6" ELBOW
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
REFER TO CHIMNEY
MANUFACTURER'S
INSTRUCTIONS AND
PARTS.
Chimney Connection
MASONRY CHIMNEY
Before using an existing masonry chimney, clean the chimney
and inspect the ue liner to be sure it is safe to use. Make repairs
before attaching the furnace. The connector pipe and ttings you
will need to connect directly to a masonry chimney are shown.
The chimney connection should be as short as possible.
If the connector pipe must go through a combustible wall before
entering the masonry chimney, consult a quali ed mason or
chimney dealer. The installation must conform to local re codes,
and N.F.P.A. 211.
DO NOT CONNECT THIS FURNACE TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
The chimney used for a furnace must not be used to ventilate the
cellar or basement. If there is a cleanout opening at the base of
the chimney, close it tightly.
LISTED FACTORY BUILT CHIMNEY
Carefully follow chimney manufacturer's instructions. Use only a
Listed Residential Type or Building Heating Appliance Chimney.
If your chimney starts at the ceiling (Fig. 7), you will need enough
6" pipe to reach the ceiling.
The top of the chimney must be at least 3 feet above the roof
and be at least 2 feet higher than any point of the roof within 10
feet (Fig. 7).
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through
the chimney. The amount of draft in your chimney depends on the
length of the chimney, local geography, nearby obstructions and
other factors. Too much draft may cause excessive temperatures
in the appliance. Inadequate draft may cause backpuf ng into the
room and ‘plugging’ of the chimney.
“Inadequate draft will cause the appliance to leak smoke into the
room through appliance and chimney connector joints.”
“An uncontrollable burn or excessive temperature indicates ex-
cessive draft.”
Take into account the chimney’s location to insure it is not too
close to neighbors or in a valley which may cause unhealthy or
nuisance conditions.
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
THIMBLE
6" ELBOW
6" CHIMNEY
CONNECTOR
6" ELBOW
NON-COMBUSTIBLE WALL
Figure 6
Figure 7
9
1. The crimped end of the chimney connector ts inside the furnace
ue collar. Install additional chimney connectors and elbow
with the CRIMPED END TOWARD THE FURNACE. This will
allow any condensation in the ue to run back into the furnace.
Use 6" dia. steel pipe and elbows for connection to chimney.
Never use less than 24 gauge and although blued steel is
satisfactory, high temp painted black is much more desirable.
(See Figure 8)
2. Slope any horizontal pipe upward toward the chimney at least
1/4 inch for each foot of horizontal run.
3. You must have at least 18 inches of clearance between any
horizontal piping and the ceiling.(See Fig. 5)
4. The chimney connector must not extend into the chimney ue.
(See Fig. 9)
5. Seal each chimney connector pipe joint with furnace cement.
Also seal the pipe at the chimney.
6. Use 3 sheet metal screws at each chimney pipe joint to make
the piping rigid.
7. The chimney connector may include a section for a barometric
draft regulator between the furnace and the chimney (Fig. 6,
7, & 10). The barometric draft regulator must be installed in
the same room (same pressure zone) as the furnace.
8. Install the barometric draft regulator strictly in accordance
with the instructions that are provided with the barometric draft
regulator.
9. A solid damper must be used in the chimney connecting pipes
between the ue collar and the chimney. When used in conjunc-
tion with a barometric draft regulator, the solid damper must be
placed between the barometric and the chimney. (See Fig. 6,
7, & 10)
ADJUSTING THE BAROMETRIC DRAFT
REGULATOR
1. Drill a hole in the chimney connector within 18" of the ue collar
below the barometric draft regulator just large enough for the
tube of the manometer.
2. Build a re after all chimney connections have been made.
3. Use a manometer to measure the draft in the ue.
4. Adjust the Barometric Draft Regulator to obtain a draft of 0.05
- 0.06" W.C. under stable re conditions.
RIGHT WRONG WRONG
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
NON COMBUSTIBLE
INSTALLATION PER
NFPA 211
MEASURE FLUE DRAFT HERE
Figure 9
Figure 10
Rules for Connector Pipe Installation
NOTE:
A ue pipe shall not pass through an attic, roof
space, closet or similar concealed space, a oor
or ceiling of combustible construction. Where
passage through a wall or partition is desired,
installation must conform with UL standards.
Figure 8
10
CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY
THROUGH A COMBUSTIBLE WALL
Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall.
There are ve allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible
wall. NFPA Standard 211 allows the following wall pass-through systems.
Figure 11
11
1. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A reclay liner (ASTM C315 or
equivalent) having a 5/8" minimum wall thickness must be used and it must be at least 12" away from any material
that could catch re. The inside diameter of the reclay liner shall be sized for the proper snug t of a 6" diameter
chimney connector pipe. The reclay liner shall run from the outer surface of the brick wall to, but not beyond, the
MINIMUM 12 IN.
TO COMBUSTIBLES
FIGURE 12, PART A
CHIMNEY FLUE
MINIMUM CHIMNEY CLEARANCE TO
BRICK AND COMBUSTIBLES IS 2 IN.
MINIMUM CLEARANCES 12 IN.
OF BRICK ALL AROUND
CHIMNEY CONNECTOR
TO HEATER
FIRE CLAY LINER
(5/8" MIN. WALL THICKNESS)
MIN. 3-1/2" THICK BRICK
MASONRY WALL
MASONRY CHIMNEY
CONSTRUCTED TO
NFPA 211
FIGURE 12, PART B
AIR SPACE
9 IN. MINIMUM
FACTORY-BUILT
CHIMNEY LENGTH
MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
CHIMNEY LENGTH
FLUSH WITH INSIDE
OF FLUE
NONSOLUBLE
REFACTORY
CEMENT
MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211
CHIMNEY CONNECTOR
TO HEATER
MINIMUM CLEARANCE
9 IN. ALL AROUND
SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)
CHIMNEY FLUE
SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY LENGTH
USE CHIMNEY MFRS. PARTS TO
ATTACH CONNECTOR SECURELY
AIR SPACE
inner surface of the chimney ue and shall be rmly cemented in place. See Part A.
2. Use a solid insulated listed factory-built chimney length having an inside diameter of 6" and having 1" or more of solid
insulation. There must be at least a 9" air space between the outer wall of the chimney length and any combustible
materials. The inner end of the chimney length shall be ush with the inside of the masonry chimney ue and shall be
sealed to the ue and to the brick masonry penetration with nonwater-soluble refractory cement. Sheet steel supports
TWO VENTILATED AIR
CHANNELS EACH 1 INCH.
CONSTRUCTED OF
SHEET STEEL.
FIGURE 12, PART C
MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211
SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)
MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
MINIMUM 6 IN. GLASS
FIBER INSULATION ALL AROUND
24 GAUGE
VENTILATED THIMBLE WITH
TWO 1 INCH AIR CHANNELS
CHIMNEY THIMBLE
CHIMNEY FLUE
CHIMNEY CONNECTOR
TO HEATER
which are at least 24 gauge (0.024") in thickness shall be securely fastened to wall surfaces on all sides. Fasteners
between supports and the chimney length shall not penetrate the chimney liner. See Part B.
3. Use a 10" diameter ventilated thimble made of at least 24 gauge (0.024") steel having two 1" air channels. The venti-
lated thimble must be separated from combustible materials by a minimum of 6" glass ber insulation. The opening
12
SHEET STEEL SUPPORTS
CHIMNEY SECTION
CHIMNEY
CONNECTOR
AIR SPACE
2 IN.
FIGURE 12, PART D
MINIMUM CLEARANCE
2 IN. ALL AROUND
CHIMNEY THIMBLE 1 IN. AIR SPACE TO
CHIMNEY LENGTH
MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211
SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)
CHIMNEY FLUE
MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
CHIMNEY CONNECTOR
TO HEATER
SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY
LENGTH (12 IN. LONG MIN.)
in the combustible wall shall be covered and the thimble
supported with sheet steel supports which are at least
24 gauge (0.024") in thickness. The sheet steel supports
shall be securely fastened to wall surfaces on all sides
and shall be sized to t and hold the chimney section.
Fasteners used to secure chimney sections shall not
penetrate chimney ue liner. See Part C.
4. Use an 8" inside diameter solid insulated listed factory-
built chimney length which has 1" or more of solid insula-
tion. The minimum length of this chimney section shall be
12" and will serve as a pass-through for the 6" diameter
chimney connector. There must be at least a 12" air
space between the outer wall of the chimney section and
any combustible materials. The chimney section shall
be concentric with and spaced 1" away from the chimney
connector by means of sheet steel support plates on
both ends of the chimney section. The opening in the
combustible wall shall be covered and the chimney sec-
tion supported on both sides with sheet steel supports
which are at least 24 gauge (0.024") in thickness. The
sheet steel supports shall be securely fastened to wall
surfaces on all sides and shall be sized to t and hold
the chimney section. Fasteners used to secure chimney
sections shall not penetrate chimney ue liner. See Part
D.
5. A listed factory-built wall pass-through system may be
purchased and installed according to the instructions
packaged with it to provide a safe method of passing
the chimney connector through a combustible wall for
connection to a masonry chimney.
Additional requirements pertaining to Figure 8 and
the above wall pass-through systems:
1. Insulation material used as part of wall pass-through
system shall be of noncombustible material and shall
have a thermal conductivity of 1.0 Btu • in./ft.² • °F (4.88
kg • cal/hr • m² • °C) or less.
2. All clearances and thicknesses are minimums: larger
clearances and thickness are acceptable.
3. A chimney thimble, as shown for 3" and 4" above (Parts
C and D) shall be for types "3" and 4" connections to
facilitate removal of the chimney connector for cleaning.
The chimney thimble shall be of ASTM C315 reclay with
5/8" minimum wall thickness, or material or equivalent
durability. The inside diameter of the thimble shall be sized
for the proper snug t of a 6" diameter chimney connector
pipe. The thimble shall be installed without damage to
the chimney ue. The thimble shall extend through the
chimney wall to, but not beyond, the inner surface of the
chimney ue and shall be permanently cemented in place
with high temperature cement.
4. A chimney connector to a masonry chimney, except for
2" above (Part B), shall extend through the wall pass-
through system to the inner face of the chimney ue, but
not beyond. It does not have to be fastened in place so
long as it cannot accidently be pulled out of the chimney
or shoved into the chimney ue. If fasteners are used
to secure the chimney connector to a masonry chimney,
the fasteners shall not penetrate the chimney ue liner.
5. Any material used to close up any opening for the con-
nector shall be noncombustible.
PART E - (Figure 12)
In addition to the methods shown by A, B, C, and D of
Figure 12, a listed factory-built wall pass-through sys-
tem may be purchased and installed according to the
instructions packaged with it to provide a safe method
of passing chimney connector through a combustible
wall for a connection to a masonry chimney.
If the chimney connector does not have to pass through a
combustible wall to get to a masonry chimney, simply con-
nect the chimney connector directly to the masonry chim-
ney's chimney thimble as described and shown by parts C
and D of Figure 12. Remember, the chimney connector
should extend into the chimney thimble to the innerface of
the chimney ue but not beyond; if the chimney connector
is extended through the chimney thimble into the chimney
ue, resistance to the ow of smoke and gases up the chim-
ney will occur; that ow resistance will have an adverse
affect on the operation and performance of the heater and
venting system.
CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN CHIMNEY CONNECTOR
DOES NOT PASS THROUGH A COMBUSTIBLE WALL
13
THERMODISC
THERMODISC
COVER
4” ELECTRICAL
JUNCTION BOX
BLOWERS
BLOWERS GASKET CLIP NUTS
(Not used in the upper center hole.)
ASSEMBLY OF FURNACE
Your furnace requires the following items to be assembled
or installed by the service person:
Feed Door Pull Handle
Feed Door Locking Handle
Blowers and Blower Controls
Electrical Connections
1. Remove all parts from inside the furnace and inspect
for damage, including the rebrick as some breakage
could occur during shipment.
2. Assemble the feed door pull handle as shown in Figure
13. Install thermostat assembly and cover (complete
with handle) as illustrated in Figure 13b.
3. Align thermostat control knob with at on thermostat
control shaft and press onto shaft. (See Fig. 13a)
4. Attach feed door locking handle as in Figure 14 with
screws and nuts provided. Note: Slotted holes are for
adjustment of handle. Adjust handle until some pressure
is required to lock feed door during ring sequence.
5. Install the thermodisc on rear of furnace cabinet with
the two screws provided. Mount the conduit assembly
from the junction box to the thermostat bracket. Crimp
the two female terminals to each of the wire leads. Plug
the wires to the thermodisc. NOTE: It does not matter
which of the two wires plugs to which terminal on the
thermodisc.
6. Remove blowers from cartons. Remove junction box
cover. Attach clip nuts as in Figure 15. Install blower(s)
and gasket(s) with 1/4"-20 x 3/4" bolts as shown.
7. Wire right side blower rst (See wiring diagram) and
replace cover on junction box on blower.
8. Wire left blower same as above and replace cover.
9. Check operation of shaker grates with grate handle
before operating furnace.
Figure 15
(Model 1300 has only one blower)
Figure 14
Figure 13b
SET SCREW
Figure 13a
14
NOTE:
For model 1300, disregard the wiring (wires M1 & M2) of one blower
motor.
Wire leads from the distribution blower are usually BOTH BLACK.
Makes no di erence which leads from the motor(s) connects to the cor-
responding leads coming out of the conduit.
Figure 16
WIRING DIAGRAM
15
INSTALLATION
Please see all methods of Installation at the rear of
this booklet.
This is a furnace, not a free standing stove. You must direct
heated air from 8" outlets away from the furnace, or it will
not function properly.
1. This installation must be done by a quali ed heating
equipment installer.
2. The installation is to be done in compliance with National
Fire Protection Association installation standards: No.
89M, 90B, 211, 70 (National Electrical Code) and Uniform
Mechanical Code 913, 6-4, in the states where applicable.
(Their code offers connecting smoke pipe connectors
into chimney with other fuel burning appliances.)
3. Rooms large in comparison with size of the appliance:
a) Wood or Coal Burning Furnace needs air for combus-
tion and circulation to house.
b) Provision must be made to make up this air and not
starve gas or oil furnace of combustion air.
c) Have the "Authority Having Jurisdiction" determine
that air is of adequate makeup. (Reference N.F.P.A.
Nos. 30&54, Code for Installation of Gas & Oil Equip-
ment).
4. Have the "Authority Having Jurisdiction" to inspect all
chimneys and installations for adequate venting and for
compliance with standard and local codes and regula-
tions regarding installation of wood burning appliances.
5. Installation for Supplemental Heat Application to Existing
Central System.
a) Place Wood or Coal Burning Furnace so that the
chimney connector will be as short as practical and
avoiding unnecessary sharp turns in the smoke pipe
connector and the installation of devices that would
create excessive resistance to the ow of ue gases.
b) Locate the Wood or Coal Burning Furnace as close as
practical to the existing central hot air heating system,
maintaining clearances as stated on the label on the
fuel door.
c) Clearance from combustible materials must comply
with those stated on the label on the side of the unit.
Refer to the clearance table in the front of this manual.
The installation must be made only on a noncombustible oor.
d) Install the smoke pipe connector to the chimney
with 26-gauge pipe and elbows (to be purchased
separately), maintaining the proper clearances for the
speci c model. Seal the smoke pipe in the chimney
with furnace cement. (The chimney connector shall
be securely supported, and joints fastened with sheet
metal screws or rivets.)
e) Install 8" diameter heat pipe to plenum of the central
hot air furnace. Use 26-gauge pipe and connectors (to
be purchased separately). If central air conditioning
is installed in the plenum, install heat pipe above the
air conditioning unit. Secure heat pipe connection
with supports and sheet metal screws.
f) Connect electrical supply in the electrical junction
box that is mounted on the back of the Furnace. See
Wiring Diagram (Fig. 16). Remove the cover from
electrical junction box and connect power supply wires
to wires designated, using wire nuts. The power cord
supplied may be used for installation, if permitted by
local codes and regulations. If the power cord sup-
plied cannot be used, the power supply wiring must
be 90 degrees centigrade in a metal cable and should
be completed by a quali ed installer complying with
NFPA Standard No. 70 and local codes.
POWER FAILURE
INSTRUCTIONS
Operation after loss of power:
1. Remove lter if provided
2. Do not expect to keep home at normal temperatures.
3. Do not load fuel above bottom of feed door.
The top down method of re building is recommended for this
appliance. After making sure that the stove air intake controls
are fully open (completely pull-out towards you), Place the
largest pieces of wood on the bottom, laid in parallel and
close together. Smaller pieces are placed in a second layer,
crossways to the rst. A third layer of still smaller pieces is
laid crossways to the second, this time with some spaces
between. Then a fourth layer of loose, small kindling and
twisted newspaper sheets tops off the pile.
Higher ef ciencies and lower emissions generally result
when burning air dried seasoned hardwoods, as compared
to softwoods or to green or freshly cut hardwoods.
DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners, or
asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Salt water driftwood or other previously salt water
saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or particleboard.
The prohibition against burning these materials does
not prohibit the use of re starters made from paper,
cardboard, saw dust, wax and similar substances for
the purpose of starting a re in an affected wood heater.
16
Burning these materials may result in release of toxic fumes
or render the heater ineffective and cause smoke.
Dead wood lying on the forest oor should be considered
wet, and requires full seasoning time. Standing dead wood
can usually be considered to be about 2/3 seasoned. Split-
ting and stacking wood before it is stored accelerates drying
time. Storing wood on an elevated surface from the ground
and under a cover or covered area from rain or snow also
accelerates drying time. A good indicator if wood is ready to
burn is to check the piece ends. If there are cracks radiating
in all directions from the center then the wood should be dry
enough to burn. If your wood sizzles in the re, even though
the surface is dry, it may not be fully cured, and should be
seasoned longer
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this wood heater
in a manner inconsistent with operating instructions in this
manual.
VISIBLE SMOKE
The amount of visible smoke being produced can be an ef-
fective method of determining how ef ciently the combustion
process is taking place at the given settings. Visible smoke
consist of unburned fuel and moisture leaving your stove.
Learn to adjust the air settings of your speci c unit to pro-
duce the smallest amount of visible smoke. Wood that has
not been seasoned properly and has a high wood moisture
content will produce excess visible smoke and burn poorly.
Use the included moisture meter to insure your wood has
a 20% or less moisture content.
EFFICIENCIES
Ef ciencies can be based on either the lower heating value
(LHV) or the higher heating value (HHV) of the fuel. The
lower heating value is when water leaves the combustion
process as a vapor, in the case of woodstoves the moisture
in the wood being burned leaves the stove as a vapor. The
higher heating value is when water leaves the combustion
process completely condensed. In the case of woodstoves
this would assume the exhaust gases are room temperature
when leaving the system, and therefore calculations using
this heating value consider the heat going up the chimney
as lost energy. Therefore, ef ciency calculated using the
lower heating value of wood will be higher than ef ciency
calculated using the higher heating value. In the United
States all woodstove ef ciencies should be calculated using
the higher heating value.
The best way to achieve optimum ef ciencies is to learn the
burn characteristic of you appliance and burn well-seasoned
wood. Higher burn rates are not always the best heating
burn rates; after a good re is established a lower burn rate
may be a better option for ef cient heating. A lower burn
rate slows the ow of usable heat out of the home through
the chimney, and it also consumes less wood.
OVER FIRING
Attempts to achieve heat output rates that exceed heater
design speci cations can result in permanent damage to
the heater.
ASH REMOVAL AND DISPOSAL
Whenever ashes get 3 to 4 inches deep in your rebox or
ash pan, and when the re has burned down and cooled,
remove excess ashes. Leave an ash bed approximately
1 inch deep on the rebox bottom to help maintain a hot
charcoal bed.
Ashes should be placed in a metal container with a tight-
tting lid. The closed container of ashes should be placed
on a noncombustible oor or on the ground, away from all
combustible materials, pending nal disposal. The ashes
should be retained in the closed container until all cinders
have thoroughly cooled.
SMOKE AND CO MONITORS
Burning wood naturally produces smoke and carbon
monoxide(CO) emissions. CO is a poisonous gas when
exposed to elevated concentrations for extended periods
of time. While the modern combustion systems in heaters
drastically reduce the amount of CO emitted out the chim-
ney, exposure to the gases in closed or con ned areas can
be dangerous. Make sure your stove gaskets and chimney
joints are in good working order and sealing properly to en-
sure unintended exposure. It is recommended that you use
both smoke and CO monitors in areas having the potential
to generate CO.
GASKETS
It is recommended that you change the door gasket (which
makes your stove door air tight) once a year, in order to in-
sure good control over the combustion, maximum ef ciency
and security. To change the door gasket, simply remove the
damaged one. Carefully clean the available gasket groove,
apply a high temperature silicone sold for this purpose, and
install the new gasket. You may light up your stove again
approximately 24 hours after having completed this opera-
tion. This unit’s ash door uses a 5/8" diameter rope gasket.
This unit's feed door uses a 1/2" diameter rope gasket.
OPERATIONAL TIPS
Operational Tips for Good, Ef cient, and Clean Com-
bustion
Get the appliance hot and establish a good coal bed
before adjusting to a low burn rate (this may take 30
minutes or more depending on your wood)
Use smaller pieces of wood during start-up and a
high burn rate to increase the stove temperature
Be considerate of the environment and only burn
dry wood
Burn small, intense res instead of large, slow burn-
ing res when possible
17
A draft reading of .05 to .06 w.c. is suggested for proper burning of this unit when using wood or
bituminous coal as fuel. When using anthracite coal, this draft reading is a minimum reading.
CAUTION
A chimney re may cause ignition of wall studs or rafters which you thought were a safe distance
from the chimney. If you have a chimney re, have your chimney inspected by a quali ed person
before using again.
Learn your appliance's operating characteristics to
obtain optimum performance
Burning unseasoned wet wood only hurts your stoves
ef ciency and leads to accelerated creosote buildup
in your chimney
SERVICE HINTS
Do not expect a furnace to draw. It is the chimney that
creates the draft. Smoke spillage into the house or
excessive build-up of water or creosote in the chimney
are warnings that the chimney is not functioning prop-
erly. Correct the problem before using furnace. Possible
causes are:
1. The connector pipe may be pushed into the chimney
too far, stopping the draft.
2. Do not connect two furnaces or a stove and furnace
into the same chimney ue.
3. The chimney used for a furnace must not be used to
ventilate the cellar or basement. If there is a cleanout
opening at the base of the chimney, it must be closed
tightly.
4. If the chimney is operating too cool, water will condense
in the chimney and run back into the furnace. Creosote
formation will be rapid and may block the chimney.
Operate the furnace at a high enough re to keep the
chimney warm, preventing this condensation.
5. If the re burns well, but sometimes smokes or burns
slowly, it may be caused by the chimney top being
lower than another part of the house or a nearby tree.
The wind blowing over a house or a tree, falls on top
of the chimney like water over a dam, beating down
the smoke. The top of the chimney should be at least
3 feet above the roof and be at least 2 feet higher than
any point of the roof within 10 feet.
6. See page 18 for list of trouble shooting tips.
CHIMNEY MAINTENANCE
Creosote and Soot - Formation and Need for Removal
When wood is burned slowly, it produces tar and other or-
ganic vapors, which combine with expelled moisture to form
creosote. The creosote vapors condense in the relatively
cool chimney ue of a slow-burning re. As a result, creo-
sote residue accumulates on the ue lining. When ignited,
this creosote makes an extremely hot re.
When coal is burned, the products of combustion combine
with moisture to form a soot residue which accumulates on
the ue lining. When ignited, this soot makes an extremely
hot re.
The chimney should be inspected at least twice monthly
during the heating season to determine if a creosote or soot
build up has occurred.
If creosote or soot has accumulated, it should be removed
to reduce the risk of a chimney re.
Chimney res burn very hot. If the chimney catches re,
immediately call the re department, then reduce the re
by closing the inlet air control. Pour a large quantity of
coarse salt, baking soda or cool ashes on top of the re in
the rebox.
ATTENTION:
This wood heater needs periodic inspection and repair for proper operation. It is against federal
regulations to operate this wood heater in a manner inconsistent with operating instructions in this
manual.
18
TROUBLE SHOOTING TIPS FOR WARM AIR FURNACE
1. Problem:
Smoke puffs from furnace
Solution:
A. Check chimney draft. Check for blocked chimney or
ue pipe. Use mirror to check chimney clearance.
B. Check ash pit — if it is too full, empty.
C. Make sure furnace room is not too airtight.
D. Make sure all of chimney mortar connections are
airtight.
E. Check ash drawer. Make sure it’s airtight.
F. Check chimney for possible down-draft caused by
taller surrounding trees or objects. Correct with proper
chimney vent cap.
G. Check the possibility of a cold chimney forcing cool
gases backward. Remedied by properly insulating
chimney with non-combustible liner — non-combus-
tible insulation.
H. Fuel may be too green.
I. Make sure no other fuel burning devices are con-
nected to the chimney impairing the draft.
J. Check chimney draft, it should be .06 inches of wa-
ter column. This service is provided by a certi ed
chimney sweep.
2. Problem:
Inadequate heat being delivered to your home
Solution:
A. Check home insulation — is it adequate?
B. Check hook-up to furnace — is it installed correctly?
C. Cool air inlet may be inadequate or furnace room
too airtight.
D. Your wood fuel may be too low grade. Hardwoods
are recommended.
E. Make sure your hot air duct (and other duct work) is
airtight.
F. If furnace room is warm but your home isn’t, check
back draft dampers.
G. Is air to the blower available?
3. Problem:
Excess smoke or ames coming out door when refueling
Solution:
A. Wait 15 seconds and open door SLOWLY — then
refuel.
B. Check length of ue pipe to chimney. Your unit should
be within six (6) feet of your chimney.
C. Make sure chimney cap is not too close to the top
of the chimney.
D. Check chimney draft — make sure chimney ue pipe
is clean and chimney is of adequate height.
E. Make sure you’re not suffocating the re with exces-
sive amounts of unburned wood.
F. Slide baf e should be pulled out prior to load door
opening.
4. Problem:
Distribution blower vibrating
Solution:
A. Tighten blower wheel to motor shaft.
B. Check for bad fan bearings.
5. Problem:
Distribution blower continues to run or will not run
Solution:
A. Check fan limit or heat sensor and cable.
B. Check to see that blower is properly wired.
(See Wiring and Assembly Instructions).
C. Check fuse box or power source.
D. Check power supply.
6. Problem:
Odor from rst re
Solution:
A. The odor from new steel should disappear in a few
hours.
B. If the odor remains, call you dealer immediately. A
bad weld can cause a fume leak.
7. Problem:
Excessive Creosote
Solution:
A. Check the grade of wood you are burning.
B. Make sure your unit is serviced by its own proper
chimney.
C. Check length of ue pipe and its connections.
D. Make sure you are burning the smallest, hottest re
to adequately heat your home.
E. Also see Solutions to Problem one.
8. Problem:
If the re goes out or does not hold over night
Solution:
A. Poor Draft.
B. Incorrect damper settings.
C. Improper ring methods if burning coal.
D. More combustion air needed.
E. Coal not sized to the furnace. We recommend 1” to
3” diameter pieces of coal.
F. Ashes, if allowed to accumulate in the ash pit, will
not allow passage of the required air for combustion.
Keep ash pit clean.
G. This furnace is not to be used with an automatic
stoker unless so certi ed.
19
Repair Parts
22
6
8
7
9
20
18
19
17
16
14
10
15
11
12 13
21
1
5
2 3
4
1
28
27
26
29
30 31
24
25
32
33
23
36
34
39
38
37
41
34 35
39
37
38
40
40
42
34
1300 1400 1500
20
125541R Cabinet Side (Left & Right) 1300 2
25467R 1400, 1500
2 88032 Flue Collar Gasket 2
3 40246 Flue Collar 1
N/S 83227 Bolt, 1/4-20 x 1" 6
N/S 83250 Kep Nut, 1/4-20 6
425540R Cabinet Back 1300 1
23459R 1400, 1500
525561R Cabinet Top 1300 1
25466R 1400, 1500
N/S 891214 8" Collar 2
6 68217 Feed Door Assy. (Includes Gasket - 88057) 1
7 22662 Bracket, Feed Door 1
8 24232 Spacer, Hinge 1
9 891097 Locking Mechanism, Feed Door 1
10 68218 Ash Door Assy. (Includes Gasket - 88066) 1
11 86626 Latch, Door 1
12 83461 Washer (1" OD, 7/16" ID) 1
13 83274 Lock Nut, 3/8-16 1
14 891098 Handle Assy. w/Handle Bushing 1
15 23859B Draft Cap, Painted 1
16 891135 Handle, Spring 2
17 23800 Smoke Curtain 1
18 23787 Clip, Smoke Curtain 2
19 83445 1/4-20 x 1-1/4 Carriage Bolt 2
20 83250 Kep Nut, 1/4-20 2
21 68238 Ash Pan 1300 1
68228 1400, 1500
22 23397 Baf e, Flue 1300 1
23398 1400, 1500 2
23 22761B Flue Collar Ring 1
24 22762B Forced Draft Ring 1
25 86402 1-1/2" Pipe Plug 1
26 80230 Blower 1300 1
1400, 1500 2
27 89319 Gasket, Blower 1300 1
1400, 1500 2
28 83340 1/4-20 Clipnut 1300 4
1400, 1500 8
N/S 83339 Bolt (1/4-20 x 3/4") 1300 4
1400, 1500 8
29 22140 Relay Box Bracket 1
30 80131 Junction Box (4 x 4) 1
31 80231 Junction Box Cover 1
32 80314 Thermodisc (60T12) 1
33 68234 Blower Thermostat Bracket 1
34 89066 Firebrick (4.5 x 9 x 1.25) 1300 10
1400, 1500 12
35 891414 Firebrick (2.25 x 9 x 1.25) 1400 2
36 40264 Liner, Front/Rear 1300 2
37 40256 Grate Frame, Shaker 1300 1
1500 2
38 40257 Grate, Shaker 1300 1
1500 2
39 40260 Handle, Shaker 1300 1
1500
40 40258 Liner - Front/Rear 1400 1
1500
41 40269 Liner - Front 1500 1
42 40263 Grate - Wood 1400 3
N/S = Not Shown
Color Code: R = Red
Parts List
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL
MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE
APPLIANCE MANUFACTURER.
USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Hotblast 1400 Owner's manual

Category
Wood stove
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI