WilTec 50752 Operating instructions

Type
Operating instructions

WilTec 50752 is a garden pump suitable for watering green spaces, vegetable patches, and gardens, as well as for operating lawn sprinklers. It can withdraw water from ponds, streams, rain barrels, rainwater tanks, and fountains with its pre-filter. The pumped media can be clear water (sweet water), rainwater, or suds (slightly soiled water). It has a maximum flow rate of 3500 l/h, a maximum delivery head of 46 m, and a maximum suction head of 8 m. The pump output is 1200 W and the voltage/frequency is 220V/50Hz.

WilTec 50752 is a garden pump suitable for watering green spaces, vegetable patches, and gardens, as well as for operating lawn sprinklers. It can withdraw water from ponds, streams, rain barrels, rainwater tanks, and fountains with its pre-filter. The pumped media can be clear water (sweet water), rainwater, or suds (slightly soiled water). It has a maximum flow rate of 3500 l/h, a maximum delivery head of 46 m, and a maximum suction head of 8 m. The pump output is 1200 W and the voltage/frequency is 220V/50Hz.

© by WilTec Wildanger Technik GmbH Seite 1
http://www.wiltec.info
Operation Manual
Garden Pump
ARTICLE 50752
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ
insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities please contact us.
© by WilTec Wildanger Technik GmbH Seite 2
http://www.wiltec.info
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury by means of fire or
electric shock we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you have understood its
content.
Always use a grounded power connection with the appropriate mains voltage. You can find the
corresponding mains voltage on the type plate. If you have any doubts about the connection being
grounded, have it checked by a qualified professional. Never use a faulty electric cable.
Do not open the pump in a wet or damp environment or if you are wet yourself and protect it from
direct sunlight. Install this device in a safe location so that nobody can step on the cable, fall over or
damage it. Make sure additionally you provide sufficient cooling through the ambient air and avoid
heat accumulation. Disconnect the power plug before cleaning the pump and use only a damp cloth
for cleaning. Avoid using cleaning agents and take care that no fluids penetrate into the device.
The interior of the pump contains no parts that can be inspected or serviced by the user. Leave the
maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised
intervention the 2-year warranty is no longer valid! Keep these operation instructions safe.
1. Safety guideline
BEWARE:
The use of this device is allowed on standing bodies of
water, garden ponds or swimming ponds and their
surrounding areas only with fault current protection-switch
with a triggering nominal current up to 30mA (according to
VDE 0100 Article 702 and 738).
The device is not suitable for use in swimming pools,
paddling pools and other bodies of water in which during
operation people or animals linger. The operation of the
device during the stay of people and animals in the danger
zone is not allowed. Ask your electrician.
The device is not intended for use by persons (including children) with impaired or limited physical,
sensory and mental abilities or lack of experience and/or real knowledge, unless they are supervised
by a person responsible for their safety or you follow the instructions made by this person how to use
the device correctly.
Children should be supervised to make sure that they do not play with the device.
ATTENTION:
Run a visual inspection of the device before every use. Do not use the device if the safety
appliances are damaged or worn out. Never override safety regulations.
Use the device exclusively according to the intended purpose stated in the instructions for
use.
You are responsible for the safety of the working environment.
If the cable or the plug is damaged because of external influences, the cable must not be
repaired! It has to be replaced with a new one. This work can be carried out only by an
electrician.
The voltage indicated on the type plate of the device of 230 Volt alternating voltage has to
correspond to the existent mains voltage.
Never lift, carry or fixate the device by using the power cable.
Make sure that the electrical plug connection is placed in a flood-proof area and is protected
from moisture
© by WilTec Wildanger Technik GmbH Seite 3
http://www.wiltec.info
Before working on the garden pump disconnect the appliance by taking the plug out of the
socket.
The user is responsible for the compliance with location specific safety and installing
regulations. (Ask an electrician).
Consequential damage arising from flooded rooms caused by dysfunctions of the appliance
must be avoided by means of the appropriate measures. (installing an alarm system, reserve
pump).
In case of malfunction the repair work can be carried out only by a qualified electrician or the
WilTec-service.
The garden pumps must not run dry or having a completely closed intake port. The
manufacturer’s guarantee is no longer valid if the damage is caused by dry running.
The garden pump must not be used for swimming pools.
The device cannot be employed for potable water circuits.
WARNING:
Read carefully all the safety guidelines and the instructions.
Non-compliance with the safety rules and regulations can lead to an electric shock, fire and/or serious
injury. Keep the instructions and the safety guidelines in a safe place in case you need them in the
future.
Stability
The max. temperature of the conveyed water should not exceed +35°C in permanent operation. The
conveyance of explosive, flammable or gassing fluids is not allowed.
The conveyance of aggressive fluids (acids, bases, etc.) as well as of abrasive liquids (for example
sand) must be avoided.
To avoid damage caused by dry running we strongly recommend our customers to use one of our
automatic pump controls that prevent the pump from running dry.
Intended use
Field of application
For watering green spaces, vegetable patches and gardens.
For operating lawn sprinklers.
With pre-filter for withdrawing water from ponds, streams, rain barrels, rainwater tanks and
fountains.
Pumped media
For pumping clear water (sweet water), rain water or suds (slightly soiled water).
Operating instructions
We recommend the use of a prefilter and a suction set with suction hose, suction strainer and a check
valve to prolong the suction process and to avoid damaging the pump with stones and foreign bodies.
Technical Data:
Pump output
1200 W
Voltage/Frequency
220V/50Hz
Max. flow rate
3500 l/h
Max. delivery head
46 m
Max. suction head
8 m
Connection
1“ IG
© by WilTec Wildanger Technik GmbH Seite 4
http://www.wiltec.info
Electrical connection
The electrical connection takes place via an electric safety socket 230 V ~ 50 Hz. Fuse protection
at least 10 Amperes.
The appliance is turned on/off by means of the ON-/OFF-switch. The indicator light of the switch
glows, if the engine is started.
The engine is protected against overloading or blocking by means of a built-in motor protection. In
case of overheating the pump is turned off automatically due to the overheat protection and after
the cooling the pump is automatically started.
Suction line
Connect a suction hose (plastic hose min. 3/4" spiral reinforced) directly or with a thread nipple to
the suction connection (1" internal thread) of the pump.
The suction which is used should have a suction valve. In case the suction valve cannot be
employed a check valve should be installed in the suction line.
Position the suction line from the water withdrawal to the pump on a rising gradient. Avoid by all
means placing the suction line higher than the pump height, air pockets in the suction line slow
down and impede the suction process.
The suction and the pressure line have to be installed in such a way, so that they do not exert any
mechanical pressure on the pump.
The suction valve should lie deeply enough in the water, so that a drop in the water level cannot
lead to the dry running of the pump.
A leaking suction line prevents the suction of water due to air intake.
Avoid sucking in foreign particles (sand etc.) and if necessary install a prefilter.
Pressure line connection
The pressure line (should be at least 3/4") must be connected directly or via a thread nipple to the
pressure line connector (1" internal thread) of the pump.
With the suitable screw joints a 1/2"- pressure hose can be used. Correspondingly the pump
output is reduced due to the small pressure hose.
During the suction process the shut-off devices (valves, spray nozzles) in the pressure line must
be completely open so that the air in the suction line can escape freely.
Commissioning
Position the pump on a stable and flat location with a temperature that does not exceed 40°C.
Place the pump in a horizontal position so that the bearing can function properly; tighten the
pump to the ground.
Install the suction line so that it is ready for use. The suction hose should not be narrower than
the suction connection. If the suction height exceeds 4 m, you must use a suction line with a
larger diameter.
Establish the electrical connection.
Fill in the pump with water at the pressure port.
During the suction process the shut-off devices (valves, spray nozzles) in the pressure line must
be completely open so that the air in the suction line can escape freely.
Depending on the suction height and the air quantity in the suction line, the first suction process
can take approx. 0,5 min - 5 min. For longer suction periods new water should be refilled.
If the pump is removed after its use, do not forget it has to be refilled with water (before you
operate the pump again) before restarting and connecting it again.
© by WilTec Wildanger Technik GmbH Seite 5
http://www.wiltec.info
Maintenance advise
The pump is largely maintenance-free. For a long operating life we recommend regular checks
and maintenance.
Attention!
Before every maintenance the pump must be switched off, so disconnect the pump from the
power supply.
During long periods of non-use the pump must be rinsed thoroughly with water, completely
emptied and stored in a dry environment.
In case of danger frost the pump must be completely emptied.
After longer non-operation periods, check if the rotor turning is carried out properly by briefly
switching on and off.
In case the pump is blocked, connect the pressure line to the water line and remove the suction
hose. Open the water line. Turn on the pump for sevaral times for approx. two seconds. This way
blockages can be cleared in most cases.
Pump’s Dysfunctions
No engine running
Cause
Remedy
No supply voltage
Check the power supply
Pump wheel is blocked Thermal controller has
shut down
Dismantle the pump and
clean it
Parts
Description
1
Pump housing
2
Vent screw
3
sealing
4
Impeller
5
Screw
6
Impeller
7
Rotating. mech. sealing
8
Fixed mech. sealing
9
Abstreifer
10
Screw
11
Engine connection
12
Bearing
13
Connection box
14
Capacitor (1 Phase)
15
Cable connection
16
Stator
17
End cap
18
Fan casing
19
Bearing
20
Washer
21
Fan
22
Cable inlet
23
Screw
24
Engine housing
25
Foot
26
Rotor
27
Shaft
28
Key (Block)
29
Key (Block)
30
Screw nut
31
"O" Ring
32
Drain screw +sealing
© by WilTec Wildanger Technik GmbH Seite 6
http://www.wiltec.info
The pump does not suck in
Cause
Remedy
The suction valve is not in the water
Put the suction valve in the water
Pump room without water
Fill in water in the pump suction
nozzles
There is air in the suction line
Check the sealing of the suction line
Suction valve leaks
Clean the suction valve
Saugkorb (Saugventil) verstopft
Clean the suction strainer
Max. suction height is exceeded
Check the suction height
Insufficient flow rate
Remedy
Check the suction height
Clean the suction strainer
Place the suction valve more deeply
Clean the pump and replace the wear
part
Thermal controller shuts down the pump
Cause
Remedy
Engine overload high friction with
other foreign particles
Dismantle the pump and clean it,
prevent the suction of foreign
particles (Filter)
Attention!
The pump must not run dry.
Pump control
Pressure switch EDWC2001
The pressure switch automatically controls the start & stop of the pump depending on the pressure
drop (opening of the water faucet) and the water flow stop (closing the water faucet). The pressure
switch stops the pump if no water is conveyed (protection against dry running).
Technical data - specifications:
Input voltage 220-250V / 50 Hz / Max. 10A
Pressure range 1 - 3,5 bar / 51 psi
Max. pressure 10 bar
Max temperature 55°C
Connections 25,4 mm external thread
Protection class IP 65
© by WilTec Wildanger Technik GmbH Seite 7
http://www.wiltec.info
Function:
1. Starts and Stops the pump automatically.
2. It protects the pump against damage caused by dry running.
3. The pressure switch starts the pump for 15 seconds, if it is connected to the voltage
source. If the pressure in the line system drops, the pump is restarted. In the case of the
conventional systems with pressure switch & pressure tank, the pump stops running if a
certain pressure level is achieved. In contrast to this, the pressure switch stops depending
on the flow rate. In doing so it delays the pump’s switching off for a few seconds (7 to 15
seconds) to minimize the number of pump starts.
LED-indication:
1. The upper (1st) LED (Alarm) blinks: the automatic unit is off due to lack of water (protection
against dry running), press „Restart“ to start the unit again.
2. The middle (2nd) LED blinks: the pump is switched on.
3. The lower (3rd) LED blinks: the switch has voltage
4. Restart (Reset) restart button
Possible dysfunctions and their solutions:
Dysfunction
Dysfunction of the unit
Dysfunction outside the unit
The pump won’t start
- Circuit board is damaged
- Missing voltage
- Pump is defect
- Mixed up electric cables
Dry running display
despite water
- Set pressure too high (Adjust the
pressure setting screw till the red
Alarm-LED is off, if the pump stops
Pump does not stop
- Circuit board is damaged
- The flow detector is trapped in the
upper position
- the reset-button is blocked
- The pump has not enough pressure
- There is a leak with more
than 0,6 l/min loss
Pump runs intermittently
(The pump starts and
stops constantly)
- Circuit board is damaged
- The pump has not sufficient
pressure
- There is a leak with more
than 0,6 l/min loss
© by WilTec Wildanger Technik GmbH Seite 8
http://www.wiltec.info
Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2002/96/EC) were
implemented in the law related to electrical and electronic equipment and appliances.
All Wiltec electric devices that fall under the WEEE regulations are labelled with the crossed-out
wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the
domestic waste.
The company Wiltec Technik GmbH has been registrated in the German registry EAR under the
WEEE-registration number DE45283704.
Disposal of used electrical and electronic appliances
(intended for use in the countries of the European
Union and other European countries with a separate
collection system for these appliances).
The logo on the article or on its packaging points out
that this article must not be treated as normal
household waste but must be disposed to a recycling
collection point for electronic and electrical waste
equipment. By contributing to the correct disposal of
this article you protect the environment and the health
of your fellow men. Environment and health are
threatened by inappropriate disposal.
Materials’ recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal
waste disposal facilities or the store where you purchased the article.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part of this instructions
manual require the written permission of Wiltec Wildanger Technik GmbH.
© by WilTec Wildanger Technik GmbH Seite 9
http://www.wiltec.info
EC-Declaration of Conformity
(According to the guidelines 2004/108/EC)
Producer / person responsible
WilTec Wildanger Technik GmbH
Koenigsbenden 12
52249 Eschweiler, Deutschland
Ensures that the product:
Hauswasserwerk / Gartenpumpe
Type:
50752
Intended use:
Water pump with pressure switch
When properly used, the above mentioned model fulfils the basic requirements and
the guidelines complying with the
2004/108/EC
When evaluating the product according to the EU demands, the following standards
were applied:
EN 55014-1:2006
EN 55014-2:1997+A1
EN61000-3-2:2006
EN61000-3-3:1995+A1+A2
If the product is changed this declaration loses its validity.
Eschweiler, 13. Oktober 2009
__________________________
Bernd Wildanger
Manager
This product can be employed in all EU-states without any restrictions (as well as in other states that
follow the EU Directives).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

WilTec 50752 Operating instructions

Type
Operating instructions

WilTec 50752 is a garden pump suitable for watering green spaces, vegetable patches, and gardens, as well as for operating lawn sprinklers. It can withdraw water from ponds, streams, rain barrels, rainwater tanks, and fountains with its pre-filter. The pumped media can be clear water (sweet water), rainwater, or suds (slightly soiled water). It has a maximum flow rate of 3500 l/h, a maximum delivery head of 46 m, and a maximum suction head of 8 m. The pump output is 1200 W and the voltage/frequency is 220V/50Hz.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI