Brocade Communications Systems ServerIron ADX 1000 Installation guide

Category
Chassis components
Type
Installation guide
53-1002066-01
25 March 2011
DRAFT: BROCADE CONFIDENTIAL
Brocade ServerIron ADX
Installation Guide
Supporting ServerIron ADX 1000, ServerIron ADX 4000,
ServerIron ADX 8000 and ServerIron ADX 10000
DRAFT: BROCADE CONFIDENTIAL
Copyright © 2011 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, the B-wing symbol, BigIron, DCFM, DCX, Fabric OS, FastIron, IronView, NetIron, SAN Health, ServerIron, TurboIron, and
Wingspan are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One, Extraordinary Networks,
MyBrocade, VCS, and VDX are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other
countries. Other brands, products, or service names mentioned are or may be trademarks or service marks of their respective
owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to
this document at any time, without notice, and assumes no responsibility for its use. This informational document describes
features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.
Export of technical data contained in this document may require an export license from the United States government.
Brocade Communications Systems, Incorporated
Document History
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
E-mail: info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: emea-i[email protected]
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 – 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
Title Publication number Summary of changes Date
Brocade ServerIron ADX Series
Installation Guide
53-1002066-01 New document March 2011
Brocade ServerIron ADX Installation Guide iii
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Contents
About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . vii
What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
Command syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
Getting technical help or reporting errors . . . . . . . . . . . . . . . . . . . . . . ix
Web access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
E-mail and telephone access . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
Chapter 1 Product Overview
ServerIron ADX fixed configuration devices . . . . . . . . . . . . . . . . . . . . 1
ServerIron ADX 1000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
ServerIron ADX chassis devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ServerIron ADX 4000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ServerIron ADX 10000 (ADX 10K) chassis. . . . . . . . . . . . . . . . . . 3
ServerIron ADX Chassis device modules. . . . . . . . . . . . . . . . . . . . . . . 4
Ethernet interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Application Switch Module (ASM) . . . . . . . . . . . . . . . . . . . . . . . . . 5
Management Module (MM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Switch Fabric Module (SFM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SSL Expansion Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ServerIron ADX 1000 power supplies. . . . . . . . . . . . . . . . . . . . . . 8
ServerIron ADX chassis device power supplies . . . . . . . . . . . . . . 8
Cooling systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ServerIron ADX 1000 cooling system . . . . . . . . . . . . . . . . . . . . . . 9
ServerIron ADX 4000 and ServerIron ADX 8000 cooling systems9
ServerIron ADX 10000 cooling systems. . . . . . . . . . . . . . . . . . . 10
Rack mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
iv Brocade ServerIron ADX Installation Guide
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Chapter 2 Installing ServerIron ADX
Installation precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
General precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Lifting precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing ServerIron ADX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Preparing the installation site . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Installing the ServerIron ADX chassis in a rack . . . . . . . . . . . . .18
Installing modules in ServerIron ADX chassis devices . . . . . . . 21
Installing an SSL Expansion module onto a management
module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Installing power supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Connecting AC power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Connecting DC power to a chassis . . . . . . . . . . . . . . . . . . . . . . . 31
Connecting DC power to ServerIron ADX chassis devices. . . . .34
Attaching a management station. . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Attaching a PC or terminal to the Console port or Ethernet port36
Attaching the management module Ethernet port to a network37
Powering On the power source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Uninstalling ServerIron ADX modules . . . . . . . . . . . . . . . . . . . . . . . .38
Uninstalling ServerIron ADX 4000, 8000 & 10000
interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Uninstalling an Application Switch module . . . . . . . . . . . . . . . .39
Uninstalling a Management module . . . . . . . . . . . . . . . . . . . . .40
Uninstalling a Switch Fabric module . . . . . . . . . . . . . . . . . . . . .40
Uninstalling a Fan module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Uninstalling a Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Installing ServerIron ADX modules in a running system. . . . . . . . . . 41
Installing a management module in a running system . . . . . . . 41
Installing an ASM module in a running system . . . . . . . . . . . . . 41
Installing an SFM module in a running system . . . . . . . . . . . . . 41
Installing an Interface module in a running system . . . . . . . . .42
Installing an Power Supplies in a running system . . . . . . . . . . .42
Installing an fan trays in a running system . . . . . . . . . . . . . . . .42
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Observing the LEDs - ServerIron ADX 1000. . . . . . . . . . . . . . . .42
Matching LEDs to locations on the ServerIron ADX 1000 . . . .44
Observing the LEDs - ServerIron ADX chassis devices . . . . . . .45
Matching LEDs to locations on ServerIron ADX chassis device
modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Replacing a Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Replacing the ServerIron ADX 1000 Fan Tray . . . . . . . . . . . . . .52
Replacing the ServerIron ADX 4000 or
ServerIron ADX 8000 Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . .52
Replacing the ServerIron ADX 10000 Fan Tray . . . . . . . . . . . . .53
Replacing the air filter in the ServerIron ADX 10000 . . . . . . . .55
Brocade ServerIron ADX Installation Guide v
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Appendix A Hardware Specifications
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Hardware specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Power specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Operating environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Storage environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Safety agency approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Electromagnetic approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Console Port Pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . .60
Management Port Pin assignments . . . . . . . . . . . . . . . . . . . . . .61
Appendix B ServerIron ADX 8000
ServerIron ADX 8000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
ServerIron ADX 8000 slot assignments . . . . . . . . . . . . . . . . . . .64
Appendix C Regulatory Statements
U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Industry Canada statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Europe and Australia. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Germany. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Power cords (Japan Denan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Appendix D Cautions and Danger
Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Danger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
vi Brocade ServerIron ADX Installation Guide
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Brocade ServerIron ADX Installation Guide vii
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
About This Document
In this chapter
Audience. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Getting technical help or reporting errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Audience
This document is designed for system administrators with a working knowledge of Layer 2 and
Layer 3 switching and routing.
If you are using a Brocade Layer 3 Switch, you should be familiar with the following protocols if
applicable to your network – IP, RIP, OSPF, BGP, ISIS, IGMP, PIM, DVMRP, and VRRP.
Supported hardware and software
In those instances in which procedures or parts of procedures documented here apply to some
switches but not to others, this guide identifies exactly which switches are supported and which are
not.
The following hardware platforms are supported by this release:
ServerIron ADX 1000
ServerIron ADX 4000,
ServerIron ADX 8000
ServerIron ADX 10000 (ADX 10K)
What’s new in this document
For further information about new features and documentation updates for this release, refer to
the release notes.
viii Brocade ServerIron ADX Installation Guide
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Document conventions
This section describes text formatting conventions and important notice formats used in this
document.
Text formatting
The narrative-text formatting conventions that are used are as follows.
For readability, command names in the narrative portions of this guide are presented in mixed
lettercase: for example, switchShow. In actual examples, command lettercase is often all
lowercase. Otherwise, this manual specifically notes those cases in which a command is case
sensitive.
Command syntax conventions
Command syntax in this manual follows these conventions:
bold text Identifies command names
Identifies the names of user-manipulated GUI elements
Identifies keywords and operands
Identifies text to enter at the GUI or CLI
italic text Provides emphasis
Identifies variables
Identifies paths and Internet addresses
Identifies document titles
code text Identifies CLI output
Identifies command syntax examples
command Commands are printed in bold.
--option, option Command options are printed in bold.
-argument, arg Arguments.
[ ] Optional element.
variable Variables are printed in italics. In the help pages, values are underlined or
enclosed in angled brackets < >.
... Repeat the previous element, for example “member[;member...]”
value Fixed values following arguments are printed in plain font. For example,
--show WWN
| Boolean. Elements are exclusive. Example: --show -mode egress | ingress
Brocade ServerIron ADX Installation Guide ix
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of
increasing severity of potential hazards.
NOTE
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference
to related information.
ATTENTION
An Attention statement indicates potential damage to hardware or data.
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you or cause
damage to hardware, firmware, software, or data.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely
hazardous to you. Safety labels are also attached directly to products to warn of these conditions
or situations.
Getting technical help or reporting errors
Brocade is committed to ensuring that your investment in our products remains cost-effective. If
you need assistance, or find errors in the manuals, contact Brocade using one of the following
options.
Web access
The Knowledge Portal (KP) contains the latest version of this guide and other user guides for the
product. You can also report errors on the KP.
Log in to my.Brocade.com, click the Product Documentation tab, then click on the link to the
Knowledge Portal (KP). Then click on Cases > Create a New Ticket to report an error. Make sure you
specify the document title in the ticket description.
E-mail and telephone access
Go to http://www.brocade.com/services-support/index.page for the latest e-mail and telephone
contact information.
xBrocade ServerIron ADX Installation Guide
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Brocade ServerIron ADX Installation Guide 1
53-1002066-01
DRAFT: BROCADE CONFIDENTIAL
Chapter
1
Product Overview
ServerIron ADX fixed configuration devices
This section describes the ServerIron ADX 1000, ServerIron ADX 4000, ServerIron ADX 8000 and
ServerIron ADX 10000 chassis.
ServerIron ADX 1000
Figure 1 shows the ServerIron ADX 1000 chassis for each model.
FIGURE 1 ServerIron ADX 1000 Chassis
ServerIron ADX 1000 is shipped in one of these base configurations:
8 x 1 Gigabit Ethernet ports with 1application core
16 x 1 Gigabit Ethernet ports with 2 application cores
16 x 1 Gigabit Ethernet ports with 4 applications cores
16 x 1 Gigabit Ethernet ports and 2 x 10 Gigabit Ethernet ports with 4 Application Cores
16 x 1 Gigabit Ethernet ports with 2 application cores and hardware SSL Acceleration
16 x 1 Gigabit Ethernet ports with 4 applications cores and hardware SSL Acceleration
16 x 1 Gigabit Ethernet ports and 2 x 10 Gigabit Ethernet ports with 4 Application Cores and
hardware SSL Acceleration
Each of these configurations corresponds to a base license. ServerIron ADX provides the ability for
On-Demand Upgrades which allows you to upgrade the features from any of the base license
configurations to the more advanced configurations. This is done by purchasing a license from
Brocade which enables more ServerIron ADX 1000 features.
ServerIron ADX 1000 basics (all models):
1 RU form factor
Two hot-pluggable AC or DC power supplies (one+one redundant)
By default, the system ships with one power supply.
One hot-pluggable fan tray
Front-to-back air cooling
Mgmt
Lnk
Act
Lnk
Act
12345678
Con
P1 P2 Fn 12 12
IN OUT
Aux Con
USB 1
910 11 12 13 14 15 16
Aux1 Aux2
2Brocade ServerIron ADX Installation Guide
53-1002066-01
ServerIron ADX chassis devices
1
DRAFT: BROCADE CONFIDENTIAL
ServerIron ADX chassis devices
This section describes the ServerIron ADX 4000 and ServerIron ADX 10000 chassis devices. The
ServerIron ADX 8000 chassis device has been replaced by the ServerIron ADX 10000 chassis
device. Although no longer available for purchase, it is still supported by Brocade and is described
in Appendix B, “ServerIron ADX 8000”.
ServerIron ADX 4000
Figure 2 shows the ServerIron ADX 4000 chassis.
FIGURE 2 ServerIron ADX 4000 Chassis
ServerIron ADX 4000 chassis basics:
4 RU form factor
Two hot-pluggable AC or DC power supplies (one+one redundant)
One power supply is required, and one is optional for redundancy. By default, the system ships
with one power supply.
One hot-pluggable fan tray with three fans
Side-to-side air cooling - left-to-right
Card slots to accommodate modules
A fully-loaded ServerIron ADX 4000 can accommodate the following components:
Two Ethernet Interface Modules
Two Application Services Modules (ASM)
One Management Module (MM)
One Switch Fabric Module (SFM)
One fan tray
Two AC or DC power supplies (one required, one redundant)
Slot ordering for ServerIron ADX 4000 is important. Refer to “Installing modules in ServerIron ADX
chassis devices” on page 21.
SI-12GC
SI-SFM
Lnk / Act Lnk / Act
SI-12GC
Lnk / Act Lnk / Act
100-240 VAC
48 VDC
SEE REAR LABEL
PS1 PS2
ASM1
ASM2
MM1
LC1
LC2
SF1
F
A
N
Console
Pwr
SI-MM Mgmt
USB
Aux1 Aux2 Aux
Console
Act
BP
In
Out
ASM
Console
Pwr
SI-ASM
1 2 3 4 5 6 7 8
Application Switch Module
BP
In
Out
ASM
Console
Pwr
SI-ASM
1 2 3 4 5 6 7 8
Application Switch Module
Pwr
Pwr
Pwr
2
1
12
11
2
1
12
11
Brocade ServerIron ADX Installation Guide 3
53-1002066-01
ServerIron ADX chassis devices 1
DRAFT: BROCADE CONFIDENTIAL
ServerIron ADX 10000 (ADX 10K) chassis
Figure 3 shows the ServerIron ADX 10000 chassis.
FIGURE 3 ServerIron ADX 10000 Chassis
ServerIron ADX 10000 chassis basics:
10RU form factor
Four hot-pluggable AC or DC power supplies (two+two redundant)
Two power supplies are required, and two are optional for redundancy. By default, the system
ships with two power supplies.
One hot-pluggable fan tray with six fans
Front-to-Back air cooling -
Card slots to accommodate modules
A fully-loaded ServerIron ADX 10000 can accommodate the following components:
Four Ethernet Interface Modules
Four Application Services Modules (ASM)
Two Management Modules (MM)
Two Switch Fabric Modules (SFM)
One fan tray
Four AC or DC power supplies (two required, one or two redundant)
Brocade ServerIron ADX 10000
rwP
elosnoC
MSA
PB 12345678
nI
tuO
eludoM hctiwS noitacilppA
MSA-IS
r w P
e l o s n o C
MSA
PB 12345678
nI
tuO
eludoM hctiwS noitacilppA
MSA-IS
rwP
MSA
PB 12345678
nI
tuO
eludoM hctiwS noitacilppA
MSA-IS
rwP
e l o s n o C
MSA
PB 12345678
nI
tuO
eludoM hctiwS noitacilppA
MSA-IS
MFS-IS
rwP
MFS-IS
rwP
CG21-IS
rwP
/ knLtcA/ knLtcA
1
2
11
21
CG21-IS
rwP
/ knLtcA/ knLtcA
1
2
11
21
CG21-IS
rwP
/ knLtcA
1
2
11
21
CG21-IS
rwP
/ knLtcA
1
2
11
21
AC OK DC OK ALM
SYSTEM
AC OK DC OK ALM
SYSTEM
AC OK DC OK ALM
SYSTEM
AC OK DC OK ALM
SYSTEM
Pwr
Pwr
Pwr
Pwr
Act
Act
SI-MM
Console
Console
Console
USB
Mgmt
Mgmt
USB
Aux1
Aux1
Aux2
Aux2
Aux
Aux
Console
Console
SI-MM
/ knLtcA
/ knLtcA
Console
Console
4Brocade ServerIron ADX Installation Guide
53-1002066-01
ServerIron ADX Chassis device modules
1
DRAFT: BROCADE CONFIDENTIAL
Slot ordering for ServerIron ADX 10000 is important. Refer to “Installing modules in ServerIron ADX
chassis devices” on page 21.
ServerIron ADX Chassis device modules
The ServerIron ADX chassis devices accommodate the modules described in this section:
“Ethernet interface modules”
Application Switch Module (ASM)”
“Management Module (MM)”
“Switch Fabric Module (SFM)”
Ethernet interface modules
The following Ethernet interface modules are supported:
4 x 10G XFP fiber
12 x 1G copper
12 x 1G SFP fiber
4 x 10G XFP Fiber
Figure 4 shows the front panel of the 4 x 10G XFP fiber module.
FIGURE 4 4 x 10G XFP Fiber Modular Ethernet Interface Module
12 x 1G Copper
Figure 5 shows the front panel for the 12 x 1G copper module.
FIGURE 5 12 x 1G Copper Modular Ethernet Interface Module
Brocade ServerIron ADX Installation Guide 5
53-1002066-01
ServerIron ADX Chassis device modules 1
DRAFT: BROCADE CONFIDENTIAL
12 x 1G SFP Fiber
Figure 6 shows the front panel for the 12 x 1G SFP fiber module.
FIGURE 6 12 x 1G SFP Fiber Modular Ethernet Interface Module
Application Switch Module (ASM)
Figure 7 shows the Application Switch Module (ASM) front panel.
FIGURE 7 ASM Front Panel
NOTE
Starting with Brocade ServerIron ADX release 12.2.1, the label for the Application Switch Module
(ASM) is changed from 'SI-ASM8' to 'SI-ASM'. Note that both represent the same underlying
hardware. The number of available application cores in the ASM module can be verified from the
output of the show version and the show license commands.
ServerIron ADX 4000 systems accommodate up to two ASMs. ServerIron ADX 8000 and ServerIron
ADX 10000 systems accommodate up to four ASMs. Each ASM has the following features:
Eight Application Cores (the number of application cores avaialable depends on the license
that is bound to the module)
SI-12GC Lnk / Act
Pwr
Lnk / Act
11
12
Lnk / Act
1
2
Lnk / Act
Pwr
11
12
Lnk / Act
BP
In
Out
ASM
Console
Pwr
SI-ASM
1 2 3 4 5 6 7 8
Application Switch Module
6Brocade ServerIron ADX Installation Guide
53-1002066-01
ServerIron ADX Chassis device modules
1
DRAFT: BROCADE CONFIDENTIAL
One front-panel DB9 console port for Application Core access
There are two versions of the ASM.
ASM4 – Available only with the ServerIron ADX 4000 bundle, the ASM4 has 4 of the available 8
Application Processors enabled. It will only work in a ServerIron ADX 4000 chassis and only in
a single ASM configuration. If an additional ASM4 module is installed, only the ASM4 module
installed in the ASM 1 slot will be accepted. If an ASM8 module is installed in a system with an
ASM4 module, the ASM4 will be rejected and the ASM8 module will be accepted by the
system. You can purchase an upgrade license to increase the capability of an ASM4 to that of
an ASM8. The ASM4 license is tied to the ASM module and not to the chassis. Consequently, a
license can be purchased to upgrade the ASM4 to use all eight available Application
Processors with all functionality and performance options enabled. With this license installed,
the ASM module functions and is recognized as an ASM8 module
ASM8 – All 8 Application processors are enabled on an ASM8 module. It can be installed in any
ServerIron ADX chassis configuration in any ASM designated slot.
Management Module (MM)
Figure 8 shows the Management Module (MM) front panel.
FIGURE 8 MM Front Panel
ServerIron ADX 4000 systems accommodate one MM. ServerIron ADX 8000 and ServerIron ADX
10000 systems accommodate up to two MMs. Each MM includes the following:
Dual core management processor
One dedicated out-of-band management port (10/100/1000 Ethernet)
One front-accessible USB port
One front-panel DB9 console port for access to the MM
One optional hardware-based SSL processing module
NOTE
The auxiliary console port on the right and the ethernet ports labeled Aux1 & Aux2 are not
currently available. They are reserved for future use.
Switch Fabric Module (SFM)
Figure 9 shows the Switch Fabric Module (SFM) front panel. One SFM is required for ServerIron ADX
4000. Two are required for ServerIron ADX 8000 and ServerIron ADX 10000.
FIGURE 9 Switch Fabric Module Front Panel
Console
Pwr
SI-MM
Mgmt
USB
Aux1 Aux2 Aux
Console
Act
Brocade ServerIron ADX Installation Guide 7
53-1002066-01
Power supplies 1
DRAFT: BROCADE CONFIDENTIAL
The front panel includes a LED that, when lit, indicates that the module is receiving power.
SSL Expansion Module
A ServerIron ADX management module can be upgraded to provide hardware-based, SSL
acceleration. This is available through installation of the SSL Expansion Module onto a ServerIron
ADX Management module. Figure 8 shows the Management Module (MM)
FIGURE 10 SSL Expansion module Installed on ServerIron ADX management module
Power supplies
This section describes the supported power supply configurations.
DANGER
The power supplies are hot swappable, which means they can be removed and replaced while
the ServerIron ADX chassis is powered on and running. However, Brocade recommends that you
disconnect a power supply from its power source before removing and replacing the supply. The
1ServerIron ADX management module 2 SSL Expansion module
1
2
8Brocade ServerIron ADX Installation Guide
53-1002066-01
Cooling systems
1
DRAFT: BROCADE CONFIDENTIAL
ServerIron ADX 4000, ServerIron ADX 8000 and ServerIron ADX 10000 chassis can be running
while a power supply is removed and replaced, but the power supply itself should not be
connected to a power source.
ServerIron ADX 1000 power supplies
ServerIron ADX 1000 accommodates up to two power supplies (AC or DC) with one required and
one redundant.
You install the power supplies (AC or DC) at the back of the chassis. Each power supply has one
LED on its faceplate to provide status. For more information about operation of the power supply
LED, refer to Table 2 on page 42. For power supply specifications, refer to “Power specifications”
on page 57.
ServerIron ADX chassis device power supplies
ServerIron ADX 4000 accommodates up to two power supplies (AC or DC) with one required and
one redundant.
ServerIron ADX 8000 and ServerIron ADX 10000 accommodate up to four power supplies (AC or
DC) with two required and one or two redundant. Because power is supplied over a common power
bus, any power supply purchased in addition to the two required will provide backup for any supply
that fails. Equipping a ServerIron ADX 8000 or ServerIron ADX 10000 with two additional power
supplies provides full redundancy for both of the required power supplies.
For power supply specifications, refer to “Power specifications” on page 57.
You install the power supplies (AC or DC) in the slots along the bottom of the chassis (ServerIron
ADX 4000 or ServerIron ADX 8000) or along the right side of the chassis (ServerIron ADX 10000).
The installed power supplies provide power to all chassis components, sharing the workload
equally and reporting their status to the Management Module (MM). If the MM detects that one of
these power supplies has failed or overheated, the MM will redistribute the failed power supply
workload to the remaining power supplies.
Each power supply has three LEDs on its faceplate that provide status for the input power, output
power and notification of alarms sent. If the input power and output power LEDs are on (a steady
green), the power supply is providing power to the chassis components. For more information about
operation of the power supply LEDs, see the AC and DC power supply sections in Table 3 on
page 45. The power supplies are hot swappable, which means you can remove and replace them
without powering down the system.
NOTE
After a power supply is removed from a ServerIron ADX 4000, ServerIron ADX 8000 or ServerIron
ADX 10000 chassis, the software determines if there is enough power to power-on the interface
modules. If it determines that there is not enough power, some interface modules are powered off.
Cooling systems
Upon system startup, the fans in ServerIron ADX run at medium speed, and the speed is changed
to low. The fans switch to high speed only if the temperature sensors detect a need for additional
cooling.
Brocade ServerIron ADX Installation Guide 9
53-1002066-01
Cooling systems 1
DRAFT: BROCADE CONFIDENTIAL
By default, ServerIron ADX polls the temperature sensor on each module every 60 seconds to get a
temperature reading. Depending on the temperature readings for the modules, the system can do
the following:
Leave the fan speed as is
Increase the fan speed
Decrease the fan speed
Shut down a module to prevent damage
If the temperature exceeds specified high temperature thresholds, the system generates a syslog
message and Simple Network Management Protocol (SNMP) trap. The system can also shut a
module down if the temperature exceeds the highest threshold. You can change default low and
high temperature thresholds for modules and fan speeds through software.
ServerIron ADX 1000 cooling system
ServerIron ADX 1000 is equipped with a fan tray containing variable-speed fans and fan controllers.
Figure 11 shows how the fan assembly slides into the back of the chassis.
FIGURE 11 Fan Tray for the ServerIron ADX 1000
ServerIron ADX 4000 and ServerIron ADX 8000 cooling systems
The ServerIron ADX 4000 and ServerIron ADX 8000 cooling systems are equipped with a fan tray
containing variable-speed fans and six fan controllers to support redundancy. ServerIron ADX 4000
contains three fans and controllers, and ServerIron ADX 8000 contains six fans and controllers.
Refer to Figure 12.
FIGURE 12 Fan Tray Front View for the ServerIron ADX 4000 and ServerIron ADX 8000
10 Brocade ServerIron ADX Installation Guide
53-1002066-01
Cooling systems
1
DRAFT: BROCADE CONFIDENTIAL
ServerIron ADX 10000 cooling systems
The ServerIron ADX 10000 cooling system provides for front-to-back cooling. It is equipped with a
fan tray containing six variable-speed fans to support redundancy. The fan tray has a fan filter that
can be changed while the ServerIron ADX 10000 is in operation. Refer to Figure 13.
ASM1
ASM2
MM1
LC1
LC2
SF1
F
A
N
ServerIron ADX 4000
ASM4
ASM3
F
SF1
MM2
MM1
LC1
LC2
LC3
LC4
A
N
SF2
ASM1
ASM2
ServerIron ADX 8000
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95

Brocade Communications Systems ServerIron ADX 1000 Installation guide

Category
Chassis components
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI