  • Hello! I've reviewed the product details document for STOBER Lubricator ZV, ZR, ZTR, ZTRS. This document provides information on how to use and maintain the lubricator for rack and pinion systems, including how to adjust the lubrication rate based on application needs, and its operating conditions. I'm ready to answer your questions about the lubricator based on this document.
  • What is the discharge period for the lubricator?
    Is the lubricator suitable for use in humid and dusty environments?
    What is the temperature range the lubricator can handle?
    How do I set the dosage rate?
STOBER Drives Inc. • Form No. 442759 • www.stober.com • 1781 Downing Drive • Maysville, KY 41056 • 606-759-5090 • sales@stober.com
STOBER Drives Inc. • Form No. 442759_EN • www.stober.com • 1781 Downing Drive • Maysville, KY • 1-800-711-3588 • sales@stober.com
Optional Lubricator for Rack
& Pinion Systems (ZV, ZR, ZTR, ZTRS Series)
STOBER oers lubrication systems for its
rack and pinion oerings. The lubricator
discharge period ranges from 1 to 12
months, depending on use. It is IP68
certied for use in an environment with
high humidity and dust. The lubricator
can handle temperature ranges of -20 to
+60°C. The hose is prelled with lubricant.
Step 1 Adjust lubricator dial.
Use Table 1 to determine the appropriate dosage
rate for the application based on the rack Mod
number and the feed speed of the system. Use
Table 2 to determine the appropriate setting on the
Flex 125 Lubricator. Adjust the lubricator dial to the
appropriate setting by inserting a at surfaced object,
such as a coin, into the slot on the dial, as illustrated
below.
Table 1 Rack and Pinion Dosage Rates
Feed
Speed
(m/s)
Dosage Rate (ml/24h)
Mod 2 Mod 3 Mod 4
<1 0.25 0.25 0.25
>1 <2 0.50 0.65 0.75
>2 <3 0.75 1.00 1.25
>3 <4 1.00 1.25 1.50
>4 1.25 1.50 2.00
Table 2 Lubricator Dosage Rate Sengs
Flex 125 Lubricator
Rotary Switch Posion
Grease Dosage
(ml/24h)
12 0.43
9 0.45
8 0.51
7 0.59
6 0.70
5 0.82
4 1.02
3 1.72
2 2.05
1 4.10
Step 2 Aach hose ng to the lubricator.
Remove the black plug from the bottom of the
lubricator and attach the hose.
Step 3 Mount lubricator.
To mount the lubricator, drill holes in the machine
or mounting plate. Bolt the lubricator xture to the
machine.
Step 4 Aach hose ngs to the felt gear mounng
sha port.
Step 5 Dispose of lubricator once lubricant is
depleted.
The lubricator can be disposed of once the lubrication
has been depleted. The battery can be recycled.
Step 6 Order replacement lubricator.
When a replacement lubricator is needed, please
contact STOBER. The replacement kit part number is
57432.
Fastening
Clip
Mounng
Sha
Felt
Pinion
Hose
Lubricator
Fing
/