Wavetek CR50 User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

– 1 –
WARRANTY
The CR50 Digital Multimeter is warranted against any defects of material
or workmanship within a period of one (1) year following the date of purchase
of the multimeter by the original purchaser or original user.
Any multimeter claimed to be defective during the warranty period should
be returned with proof of purchase to an authorized Wavetek Meterman
Service Center or to the local Wavetek Meterman dealer or distributor where
your multimeter was purchased. See maintenance section for details.
Any implied warranties arising out of the sale of a W
avetek Meterman mul-
timeter, including but not limited to implied warranties of merchantability and
fitness for a particular purpose, are limited in duration to the above stated one
(1) year period. Wavetek Meterman shall not be liable for loss of use of the
multimeter or other incidental or consequential damages, expenses, or eco-
nomical loss or for any claim or claims for such damage, expenses or eco-
nomical loss.
CONTENTS
D • Inhalt
E • Contenidos
F • Contenu
Safety Information ...................................... 3
Instrument Familiarization........................... 5
Measurement Procedures .......................... 7
Specifications .......................................... 16
Maintenance and Repair .......................... 22
Sicherheitsinformationen ........................... 3
Vorstellung des Gerätes.............................. 5
Meßprozeduren .......................................... 7
Spezifikationen ......................................... 17
Unterhalt und Reparatur ........................... 22
Información de seguridad .......................... 3
Familiarización con el instrumento............. 5
Procedimientos de medida ........................ 7
Especificaciones ...................................... 18
Mantenimiento y reparación .................... 22
Informations de Sécurité ............................ 4
Présentation de l’Appareil .......................... 5
Procédures de Mesure ............................... 7
Spécifications .......................................... 20
Maintenance et Réparation ....................... 23
CR50.Man.07.00 11/30/00 6:16 PM Page 2
– 2 –
Some states do not allow limitations on how long implied warranties last
or the exclusion or limitation of incidental or consequential damages, so the
above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
D GEWÄHRLEISTUNG
Die Digitale Multimeter Modelle CR50 ist ab Kaufdatum für ein (1)
Jahr gegen Material- und Herstellungsfehler gewährleistet. Siehe
Kapitel "Unterhalt und Reparatur" für Einzelheiten.
Implizierte Schadeforderungen sind auch auf ein Jahr beschränkt.
Wavetek Meterman ist nicht ansprechbar für Gebrauchsverluß oder
Folgeschäden, Ausgaben, Gewinnverluß, usw.
E GARANTIA
Este Multímetro Digitale Modelo CR50 está garantizado contra
cualquier defecto de material o de mano de obra durante un
periodo de un (1) año contado a partir de la fecha de adquisición.
En la sección de "Mantenimiento y Reparación" se explican los
detalles relativos a reparaciones en garantía. Cualquier otra
garantía implícita está también limitada al periodo citado de un (1)
año. Wavetek Meterman no se hará responsable de pérdidas de uso
del multí metro, ni de ningún otro daño accidental o consecuencial,
gastos o pérdidas económicas, en ninguna reclamación a que
pudiera haber lugar por dichos daños, gastos o pérdidas
económicas.
F GARANTIE
Le multimètre digitaux, Modèle CR50 est garanti pour un (1) an à
partir de la date d’achat contre les défauts de matériaux et de
fabrication. Voir chapitre "Maintenance et Réparation" pour plus de
détails. Toute garantie impliquée est également limitée à un an.
Wavetek Meterman ne peut être tenu responsable pour perte
d’utilisation ou autres préjudices indirects, frais, perte de bénéfice,
etc.
CR50.Man.07.00 11/30/00 6:16 PM Page 3
– 3 –
WARNINGS AND PRECAUTIONS
This instrument is EN61010-1 certified for Installation Category II. (local
level power distribution, appliances, portable equipment, etc, where only
smaller transient overvoltages may occur). Do not exceed the maximum
overload limits per function (see specifications) nor the limits marked on the
instrument itself. Inspect instrument, test leads and accessories before every
use. Do not use any damaged part. Never ground yourself when taking
measurements. Do not touch exposed circuit elements or probe tips. Never
replace a fuse with one of a different rating. Do not operate instrument in an
explosive atmosphere.
D • Warnungen und Vorsichtsmaßnahmen
Dieses Gerät ist EN61010-1 zertifiziert für Installationsklasse II. (Lokale
Stromverteilung, Haushaltgeräte, tragbare Geräte, usw, wo nur kleinere
Spannungsspitzen auftreten können).
Überschreiten Sie nie die
kontinuierlichen Überlastgrenzen per Funktion (siehe Spezifikationen) oder
andere Grenzen welche auf dem Gerät markiert sind.
Unsersuchen Sie
Gerät, Meßkabel, Verbinder, usw. vor jeder Messung. Beschädigte Teile
nicht verwenden
Meßspitzen und Stromkreis während der Messung nicht
berühren • Sich selbst isolieren !
Sicherung immer mit gleichwertiger
ersetzen.
Gerät nicht in explosiver Umgebung verwenden.
EXPLANATION OF SYMBOLS
D • Erklärung der Symbole = E • Significado de los símbolos = F • Explication des
Symboles
Attention! Refer to Operating Instructions •D• Achtung! Bitte
Anleitung lesen •E• ¡Atención! Consulte las Instrucciones de
Uso •F• Attention! Consultez le manuel.
This instrument has double insulation •D• Dieses Gerät ist
doppelt geisoliert •E• Este instrumento tiene doble
aislamiento •F• Cet appareil est prévu d’une double isolation.
CR50.Man.07.00 11/30/00 6:16 PM Page 4
E • Advertencias y Precauciones
Este instrumento está homologado según EN61010-1 para la Categoría
de Instalación II. Su uso está recomendado en distribución local de energía,
electrodomésticos, equipos portátiles, etc, donde solamente pueden
producirse bajos niveles transitorios de sobretensión.
No supere nunca
los límites de entrada para las diferentes funciones (vea las
especificaciones), ni los límites marcados en el propio instrumento.
Inspeccione el instrumento, las puntas de prueba y los accesorios antes de
cada uso. No utilice ningún componente que esté dañado.
No se ponga
Ud. a tierra cuando esté tomando medidas. No toque partes expuestas de los
circuitos ni los extremos de las puntas de prueba.
Nunca sustituya un
fusible con otro que no tenga las mismas especificaciones.
No utilice el
instrumento en ambientes potencialmente explosivos.
F • Avertissements et Précautions
Cet instrument est certifié EN61010-1 pour catégorie d’installation II.
(réseaux de distribution locaux, appareils électro-ménagers, appareils
portatifs, etc, où seulement des transitoires d’un niveau peu élevé peuvent
survenir).
N’excédez jamais les limites de surcharge continue par
fonction (voir spécifications) ou d’autres limites marquées sur l’appareil.
Inspectez appareil, câbles, connecteurs avant chaque mesure. N’utilisez pas
des pièces endommagées
Ne touchez pas les pointes de touche ou le
circuit pendant les mesures • Isolez-vous !
Ne remplacez les fusibles que
par des fusibles équivalents.
N’utilisez pas l’appareil dans une
atmosphère explosive.
OVERLOAD INDICATION
Range overload is indicated by “1” in the
display with all other digits blanked. Select
the next higher range until a value is
displayed. If overload condition still exists in
the highest range, the measured value is
beyond the range of the meter. Overload indication is normal in the OHMS
range when the leads are not connected to anything or when the measured
– 4 –
CR50.Man.07.00 11/30/00 6:16 PM Page 5
value is higher than the selected resistance range.
D • Überlastanzeige
Wenn ein Signal die Bereichsgrenze überschreitet erscheint das Symbol “1”
in der Anzeige. Diese Anzeige ist normal bei Widerstandsmessung wenn
Meßkabel/spitzen frei stehen oder wenn der Meßwert den Bereich
überschreitet. In allen anderen Fällen ist die Ursache der Überlast sofort zu
entfernen. Höheren Bereich wählen oder Messung unterbrechen.
E • Indicación de sobrecarga
La sobrecarga de escala se indica mediante un “1” en el visualizador, con
los demás dígitos en blanco. Elimine inmediatamente la causa de la
sobrecarga. Seleccione una escala más ata. Si ya está en la más alta,
interrumpa la medida. La indicación de sobrecarga es normal, durante la
medida de OHMS, cuando el circuito está abierto o la resistencia es
demasiado alta.
F • Indication de Surcharge
Quand un signal dépasse la limite d’un calibre choisi, le symbole “1”
apparait sur l’afficheur. Ceci est normal dans les calibres de résistance,
quand les pointes de touche ne sont pas connectées, ou si la résistance
mesurée dépasse le calibre. Dans tous les autres cas la cause du
dépassement est à enlever immédiatement. Choisissez une gamme plus
élevée ou interrompez la mesure.
PREPARATION FOR USE – UNPACKING
Your shipping carton should include the CR50, one test lead set (one black, one
red), one pair of alligator clips, one 9V battery (installed), one spare 0.1A/250V
fuse (inside the case), a warranty card and this manual. If any item is damaged
or missing, return to the place of purchase for an exchange.
D • Gebrauchsvorbereitung - Auspacken
Die Verpackung sollte enthalten: das CR50, ein Meßkabelsatz (ein schwarz,
ein rot), ein Paar Krokodilklemmen, eine 9V Batterie (im Gerät), eine
– 6 –
CR50.Man.07.00 11/30/00 6:16 PM Page 7
Général: Avant de
connecter ou de
déconnecter les cordons
de test, coupez
l’alimentation du circuit
mesuré et déchargez les
condensateurs.
RESISTANCE
MEASUREMENT
(See Fig. 1)
Turn off power to the
resistance to be measured
and discharge any
capacitors. Any voltage
present during a resistance
measurement will cause
inaccurate readings.
Connect red test lead to
+Rx Input (red) and black test lead to -Rx Input. Set Function/Range Switch
to the desired position. Connect test leads to resistance or circuit to be
measured. Read resistance value on Digital Display. Open circuits will be
displayed as an overload condition.
Note:On the 20range, an adjustment potentiometer (ZERO ADJ.) allows you
to zero out the test lead resistance. Short test leads and adjust the knob until
the display reads zero.
D • Widerstands
messung (siehe Fig. 1)
Es darf keine Spannung am Widerstand anliegen. Kondensatoren
entladen. Eine Spannung würde die Messung verfälschen.
Rotes
Meßkabel mit +Rx Eingang (rot) und schwarzes mit -Rx verbinden.
Funktionsschalter auf gewünschte Position stellen.
Meßspitzen mit
Schaltkreis verbinden.
Meßwert ablesen. Eine offene Schaltung wird mit
Überlast angezeigt.
– 8 –
Cx
200
n
20m
200p
200
ZERO
ADJUST
(20 )
OFF
20
2k
2M
20M
CR50
F
20
k
200
k
2m
200
20
2
20n
2n
CAP.
ZERO
ADJUST
Rx
DISCHARGE CAPACITOR
BEFORE CONNECTING
3
5
red/
rot/
roja/
rouge
4
2
1.520
Fig. 1
CR50.Man.07.00 11/30/00 6:16 PM Page 9
Note: Im 20 Bereich erlaubt ein Abgleichpotentiometer den Widerstand
der Meßkabel zu kompensieren. Meßspitzen kurzschließen und Knopf
drehen bis 0 angezeigt wird.
E • Medidas de resistencia (vea Fig. 1)
Asegúrese de que no hay tensión aplicada a la resistencia y descargue
los condensadores. La presencia de tensión causará imprecisión en las
medidas de resistencia.
Conecte la punta de prueba roja a la entrada +Rx
(roja) y la negra a la entrada -Rx.
Ponga el selector de función en la
posición deseada de .
Conecte las puntas de prueba a la resistencia o
circuito que vaya a medir.
Lea el valor en el visualizador. Un circuito
abierto se indicará como condición de sobrecarga.
Nota: En la escala de 20 , el potenciómetro de ajuste (ZERO ADJ) permite
cancelar la resistencia de las puntas de prueba. Una los extremos de ambas
puntas de prueba y ajuste el potenciómetro hasta obtener cero en el
visualizador.
F • Mesure de Résistance
Coupez l’alimentation du circuit et déchargez les condensateurs. La
présence d’une tension fausserait le résultat.
Connectez le cordon rouge
à l’entrée +Rx (rouge) et le noir à lentrée -Rx.
Placez le sélecteur sur la
position souhaitée.
Connectez les cordons au circuit à mesurer.
Lisez la valeur affichée. Un circuit ouvert est indiqué comme surcharge.
Note: Pour le calibre 20, un potentiomètre (ZERO ADJ.) permet de
neutraliser la résistance des cordons de test. Court-circuitez les pointes de
touche et tournez le bouton pour amener la lecture à zéro.
DIODE AND TRANSISTOR TEST (See Fig. 2)
The diode test measures the voltage drop across the diode junction. Connect
the red test lead to the +Rx Input (red) and the black test lead to the –Rx Input.
Set the Function/range switch to position. Apply probe tip of red
lead to the anode and of black lead to the cathode of the diode. The meter’s
display indicates the forward voltage drop (approximately 0.7V for silicon
diode or 0.4V for germanium diode). Meter will display overload condition for
9
CR50.Man.07.00 11/30/00 6:16 PM Page 10
an open diode. Reverse test lead connections to the diode to perform a
reverse bias test. Overload indicates a good diode.
Note 1: Overload condition for both reverse and forward bias tests indicate an
open diode. A low voltage reading for both bias tests indicates a shorted diode.
If the diode is shunted by a resistor of 1000 ohms or less, it must be removed
from the circuit before taking the measurement. Bipolar transistor junctions
may be tested in the same manner described above.
D • Dioden- und Transistortest
Der Diodentest zeigt den Spannungsabfall über den Diodendurchgang
10
Cx
200
n
20m
200p
200
ZERO
ADJUST
(20 )
OFF
20
2k
2M
20M
CR50
F
20
k
200
k
2m
200
20
2
20n
2n
CAP.
ZERO
ADJUST
Rx
DISCHARGE CAPACITOR
BEFORE CONNECTING
red/
rot/
roja/
rouge
Anode
Cathode
2
1
3
4
600 - 900mV
good/gut/bien/bon
good/ gut/
bien/ bon
bad/schlecht/
mal/mauvais
bad/schlecht/
mal/mauvais
<1V
Anode Cathode
Fig. 2
CR50.Man.07.00 11/30/00 6:16 PM Page 11
Note 1: “1” dans les deux directions indique une diode ouverte; une lecture
basse indique une diode court-circuitée. Les jonctions de transistors
peuvent être testées comme des diodes.
CONTINUITY TEST
The Continuity test checks electrical continuity between two contact points.
Set the Function/Range switch to . Plug the black test lead into the
–Rx jack (black) and connect the test lead tip to one of the contact points.
Plug the red test lead into the +Rx jack (red) and connect its test lead point to
the other contact point. (See Figure 1 for connections). The internal beeper
emits a tone when resistance is less than approx. 100.
D • Durchgangstest
Funktionsschalter auf stellen.
Rotes Meßkabel mit +Rx (rot)
Eingang und schwarzes mit -Rx Eingang verbinden.
Meßspizen mit
Schaltkreis verbinden.
Bei R 100 wird ein akustische Signal
abgegeben.
12
Cx
200
n
20m
200p
200
ZERO
ADJUST
(20 )
OFF
20
2k
2M
20M
CR50
F
20
k
200
k
2m
200
20
2
20n
2n
CAP.
ZERO
ADJUST
Rx
DISCHARGE CAPACITOR
BEFORE CONNECTING
F
red/
rot/
roja/
rouge
5
2a
2b
Fig. 3
CR50.Man.07.00 11/30/00 6:16 PM Page 13
E • Prueba de continuidad
Ponga el selector de función en la posición .
Conecte la punta
de prueba negra a la entrada -Rx (negra) y toque uno de los puntos de
contacto con el extremo.
Conecte la punta de prueba roja a la entrada +Rx
(roja) y toque el otro punto de contacto con el extremo (vea las conexiones
en la Fig. 1).
El zumbador interno emite un tono cuando la resistencia es
menor de aproximadamente 100.
F • Test de Continuité
Placez le sélecteur sur .
Connectez le cordon rouge à l’entrée
+Rx (rouge) et le cordon noir à l’entrée -Rx.
Connectez les pointes de
touche au circuit. Un signal sonore retentit pour R 100.
CAPACITANCE MEASUREMENTS (Fig. 3)
Discharge all voltage from the capacitor (via a 100k resistor) before
measuring its value. Connect the red test lead to the Cx+ input and the black
test lead to the Cx– input. Set the function/range switch to the capacitance
range that gives the best resolution. Apply probe tips to the capacitor leads.
When measuring electrolytic capacitors, observe correct polarity. Read the
capacitance value on the display (you may have to wait a few seconds until the
capacitor is fully charged). If “OL” appears in the highest range, the capacitor
is too large to be measured.
Note 1: For small value measurements utilize CAP Zero Adjust to eliminate
test lead capacitance (±20pF).
Note 2 : Small value capacitors can also be measured by inserting their leads
directly into the slots in the meter.
D • Kapazitätsmessung (siehe Fig. 3)
Kondensator entladen (über 100k Widerstand).
Rotes Meßkabel mit
Cx+ Eingang und schwarzes mit Cx- Eingang verbinden.
Wahlschalter
auf den Kapazitätsbereich stellen der die beste Auflösung gibt.
Meßspitzen mit Kondensatorleitern verbinden. Bei elektrolytischen
Kondensatoren, Polarität beachten.
Meßwert ablesen (Sie müssen
vielleicht einige Sekunden warten bis der Kondensator ganz aufgeladen ist).
13
CR50.Man.07.00 11/30/00 6:16 PM Page 14
General Specifications
Display: 3 1/2 digit LCD, 1999
counts
Zero Adjustment: Adjustment
potentiometer
Overrange Indication: “1” is
displayed
Low Battery Indication: is
displayed when the battery voltage
drops below accurate operating
level. Change battery when low
battery is indicated.
Display Update Rate: 2/sec, nominal
Operating Temperature: 0°C to 50°C,
0 to 70% Relative Humidity
Storage Temperature: -20°C to 60°C,
0 to 80% RH, battery removed
Power: Standard 9V transistor
battery, NEDA 1604, JIS 006P, IEC
6F22
Battery Life (Typical): 200 hours
alkaline, 150 hours carbon-zinc
Dimensions (H x W x D): 6.1 x 2.8 x
1.3 inches, (15.1 x 7.0 x 3.8 cm)
Weight (including battery): 8 ounces
(200 grams)
Accessories: One pair of test leads,
two alligator clips, one spare fuse
installed in battery compartment,
battery, and Operator’s Manual
Safety: Meets EN61010-1 Cat II;
EMC: Meets EN50081-1,
EN50082-1
EMC: This product
complies with requirements
of the following European
Community Directives: 89/336/EEC
(Electromagnetic Compatibility) and
73/23/EEC (Low Voltage) as amended
by 93/68/EEC (CE Marking).
However, electrical noise or intense
electromagnetic fields in the vicinity of
the equipment may disturb the
measurement circuit. Measuring
instruments will also respond to
unwanted signals that may be present
within the measurement circuit. Users
should exercise care and take
appropriate precautions to avoid
misleading results when making
measurements in the presence of
electronic interference.
Electrical Specifications
Accuracies at 23°C ± 5°C, <75% RH.
Resistance
Range/Accuracy:
20/±2% rdg.
200/±(1.0% rdg +3dgt)
2k-2M/±(1.2%rdg + 2dgt)
20M/±(3.0% rdg + 1dgt)
Resolution: 0.01 in 20rg.
OL Protection, all Ranges: 500VDC
or AC RMS
Open Circuit Voltage: 0.3VDC;
3.0VDC on 200and 2000M
ranges
Capacitance
Range/Accuracy/Test Frequency:
200pF/±(0.5% rdg +1dgt
+0.5pF)/820Hz
2000pF to 2µF/±(0.5% rdg +1dgt)/
/820Hz
20µF/±(0.5% rdg +1dgt)/82Hz
200µF/±(0.5% rdg +1dgt)/8.2Hz
16
SPECIFICATIONS
CR50.Man.07.00 11/30/00 6:16 PM Page 17
Test Voltage: < 3.5V
Input Protection: 0.1A/250V Fast
Acting Fuse
Diode Test
Test Current/Voltage: 1mA (approx.) /
3.2VDC
Display: Forward Junction Voltage
Continuity Indicator
Audible Indication: Less than 100
OL Protection: 500VDC or AC
Optional Accessories
H10Y: Protective Holster
VC20: Vinyl Carrying Case
VC30: Vinyl Carrying Case (for meter
and holster)
DL243C: Deluxe Test Lead Set
TL244: Test Leads for Alligator Clips
(AL244)
TL245: Replacement Safety Test
Leads
17
D SPEZIFIKATIONEN
Allgemeine Spezifikationen
Anzeige: 3-1/2-stelliges LCD, 1999
Punkte
Nullabgleich: Potentiometer
Überlastanzeige: “1”
Entladene Batterieanzeige: .
Batterie sofort wechseln.
Meßrate: 2 per Sekunde, nominal
Betriebstemperatur: 0°C bis 50°C, 0
bis 70% Relative Feuchte
Lagertemperatur: -20°C bis 60°C, 0
bis 80% R.F., Batterie entfernt.
Stromversorgung: Standard 9-volt
Transistorbatterie, NEDA 1604, JIS
006P, IEC 6F22
Batterielebensdauer (Typisch): 200
Stunden, Alkaline (ändert mit
Funktion und Anwendung)
Abmessung. (HxBxT): 15,1x7x3,8 cm
Gewicht (mit Batterie): 200 gr.
Zubehör: Meßkabel, 0.1A/250V
Ersatzsicherung, Batterie, ein Paar
Krokodilklemmen, Anleitung.
Sicherheit: Gemäß EN61010-1 Cat.
II: EMC: Gemäß EN50081-1,
EN50082-1
EMC Dieses Produkt
beantwortet an die
Bestimmungen der
folgenden EWG Richtlinien: 89/336/EEC
(Elektromagnetische Kompatibilität) und
73/23/EEC (Niedrige Spannung)
geändert durch 93/68/EEC (CE
Marking).
Elektrisches Rauschen und starke
magnetische Felder in der direkten
Umgebung des Meßgerätes können
jedoch den Meßkreis beeinflussen. Das
Gerät kann auch durch Störsignale im
gemessenen Schaltkreis beeinflußt
werden. Der Anwender muß Vorsichts-
maßnahmen treffen um irreführende
Meßergebnisse bei Messungen in der
Umgebung von starken elektromagne-
tischen Feldern zu vermeiden.
Elektrische Spezifikationen
Genauigkeiten bei 23°C ± 5°C,
<75% R.F.
Widerstand
Bereich/Genauigk.:
CR50.Man.07.00 11/30/00 6:16 PM Page 18
22
TROUBLESHOOTING / MAINTENANCE
If there appears to be a malfunction during the operation of the meter, the
following steps should be performed in order to isolate the cause of the
problem: Check the battery. Review the operating instructions for possible
mistakes in operating procedure. Inspect and test the Test Probes for a
broken or intermittent connection. Inspect and test the fuse. See Fuse
Replacement.
Except for the replacement of the battery or fuse, repair of the multimeter should
be performed only by a Factory Authorized Service Center or by other qualified
instrument service personnel.
The front panel and case can be cleaned with a mild solution of detergent and
water. Apply sparingly with a soft cloth and allow to dry completely before
using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
D • Fehlersuche/Unterhalt
Prüfen Sie zuerst folgende Fehlerquellen: Meßkabel (Brüche), Anschluß,
Zustand von Batterie und Sicherung, richtiger Meßvorgang, Eingangs- und
Bereichsgrenzen, usw.
Mit Ausnahme des Batterie- und Sicherungswechsels soll jede Reparatur
nur durch eine durch Wavetek anerkannte Servicestelle durchgeführt
werden.
Das Gerät kann mit einer milden Seifenlösung gereinigt werden. Sparsam
auftragen und vor Gebrauch gut trocknen lassen.
E • Localización de Averías/Maintenimiento
Para identificar la causa del problema: Compruebe la pila; revise las
instrucciones de uso; inspeccione las puntas de prueba por si hay una
conexión rota o intermitente; inspeccione la pila y el fusible.
Excepto la sustitución de la pila o el fusible, cualquier trabajo de reparación
del multímetro debe hacerse exclusivamente por personal técnico
cualificado para este tipo de reparaciones.
Para limpiar la carcasa puede utilizarse una solución suave de agua y
CR50.Man.07.00 11/30/00 6:16 PM Page 23
detergente. Aplique con un paño suave y deje secar antes de usar el
medidor.
F • Dépannage/Maintenance
Avant d’expédier votre multimètre pour réparation, vérifiez les cordons de
mesure (rupture), pile et fusible, connections, procédure de mesure, limites
d’entrée et de calibres, etc.
Excepté pour le remplacement de la pile et du fusible, toute réparation doit
être effectuée uniquement par un Centre de Services agrée par Wavetek.
Vous pouvez nettoyer le boîtier avec un détergent doux. Appliquez
parcimonieusement et laissez sécher complètement avant utilisation.
BATTERY/FUSE REPLACEMENT
Warning: To prevent electrical shock hazard, turn off the multimeter and any
device or circuit under test and disconnect the test leads before removing the
rear cover.
Remove the screws and lift off the rear case Fuse Replacement:
Remove the blown fuse (5 x 20mm) from the fuse holder. Replace with a
0.1A/250V quick acting glass fuse (one spare fuse is located on the right side
of the battery compartment). Wavetek replacement fuse part number is FP 125.
Battery replacement: Remove battery and replace with NEDA type 1604
or equivalent 9-volt alkaline battery. Reassemble the instrument.
Warnings: Use of an incorrect fuse could result in serious injury or even
23
Rear Case
Hold Down
Catch-Tabs
Front Case
Battery
CR50.Man.07.00 11/30/00 6:16 PM Page 24
fusible: Enlevez le fusible brulé et remplacez-le par un fusible rapide
équivalent 0.1A/250V (5 x 20mm) (un fusible de réserve est contenu dans
le compartiment de la pile. Référence Wavetek: FP 125.
-
Remplacement de la pile: Enlevez la pile et remplacez la par une pile
alcalin 9V, NEDA type 1604 ou équivalente.
Réassemblez l’instrument.
Avertissements: L’utilisation d’un mauvais fusible peut entraîner des
blessures graves. Ne pas éteindre l’appareil pour installer une nouvelle pile
peut endommager la pile et l’appareil.
CALIBRATION
The procedure should be performed at an ambient temperature of 25°C ± 2°C,
and at a relative humidity of less than 70%. Allow the instrument to stabilize at
this temperature for a minimum of 30 minutes.
Warning: The following procedure should be performed by trained calibration
personnel only.
Remove the back case screws, and carefully pry up the back case. See figure
4. Set the Function/Range switch to the 200nF position. Connect a 100nF
standard or calibrated capacitor to the input of the meter Adjust VR2 until the
display reads 100.0nF ±1 digit. Carefully inspect the other capacitance
ranges. Your readings should meet the capacitance accuracy specifications.
There is no adjustment for resistance. Carefully inspect the resistance
ranges. Your readings should meet the resistance accuracy specifications for
the respoective settings of the calibration source. Disconnect the DMM from
calibrator or reference standard. Reassemble the back case and secure with
two screws.
Note: If the resistance ranges are out of specification after capacitance has been
calibrated, there is a malfunction within the meter. See Repair Information for
meter return information.
D • Kalibrierung
Die Kalibrierung soll bei 25°C ± 2°C und einer relativen Feuchte von <70%
vorgenommen werden. Gerät bei dieser Temperatur 30 Minuten stabilisieren
lassen.
Warnung: Kalibrierung soll nur durch Fachpersonal vorgenommen
25
CR50.Man.07.00 11/30/00 6:16 PM Page 26
funcionamiento en el medidor. Consulte el procedimiento de devolución en
la sección de Reparación.
F • Calibrage
Le calibrage doit être effectué à une température de 25°C ± 2°C, et une
humidité relative de <70%. Laissez l’appareil se stabiliser à cette
température pendant une demie-heure
Avertissement: Le calibrage doit être effectué par un personnel qualifié.
Enlevez le boîtier arrière. (instrument éteint, câbles de mesure retirés).
Placez le sélecteur sur 200nF.
Connectez un condensateur calibré (et
déchargé) de 100.0nF ± 0.1nF aux bornes Cx et COM (ou au fentes Cx).
Adjustez VR1 pour une lecture de 100nF ±1 digit.
Vérifiez les autres
gammes de capacité. Les lectures doivent correspondre aux spécifications
de précision.
Il n’y a pas de calibrage pour la résistance. Vérifiez les
calibres de résistance avec des résistances calibrées. Les lectures doivent
correspondre aux spécifications de précision.
Réassemblez l’appareil.
Note: Si les calibres de résistance ne sont pas conformes aux spécifications
de précision, vous devez envoyer l’appareil en réparation. Voir chapitre
“Réparation”.
REPAIR
Read the warranty located at the front of this manual before requesting warranty or
non-warranty repairs. For warranty repairs, any multimeter claimed to be defective
can be returned to any Wavetek Meterman authorized distributor or to a Wavetek
Meterman Service Center for an over-the-counter exchange for the same or like
product. Non-warranty repairs should be sent to a Wavetek Meterman Service
Center. Please call Wavetek Meterman or enquire at your point of purchase for the
nearest location and current repair rates. All multimeters returned for warranty or
non-warranty repair or for calibration should be accompanied by the following
information or items: company name, customer’s name, address, telephone number,
proof of purchase (warranty repairs), a brief description of the problem or the ser-
vice requested, and the appropriate service charge (for non-warranty repairs).
Please include the test leads with the meter. Service charges should be remitted in
the form of a check, a money order, credit card with expiration date, or a purchase
order made payable to Wavetek Meterman or to the specific service center. For min-
imum turn-around time on out-of-warranty repairs please phone in advance for ser-
27
CR50.Man.07.00 11/30/00 6:16 PM Page 28
¤
TM
Manual Revision 07/00
Manual Part Number 1566212
Information contained in this man-
ual is proprietary to Wavetek
Meterman and is provided solely
for instrument operation and main-
tenance. The information in this
document may not be duplicated in
any manner without the prior
approval in writing from Wavetek
Meterman.
Specifications subject to change.
Wavetek is a trademark of
Wavetek Wandel Goltermann
© Wavetek Meterman, 2000
U.S. Service Center
Wavetek Meterman
1420 75th Street SW
Everett, WA 98203
Tel: (877) 596-2680
Fax: (425) 446-6390
Canadian Service Center
Wavetek Meterman
400 Britannia Rd. E.Unit #1
Mississauga, ON L4Z 1X9
Tel: (905) 890-7600
Fax: (905) 890-6866
European Distribution Center
Wavetek Meterman
52 Hurricane Way
Norwich, NR6 6JB, England
Tel: (44) 1603-404-824
Fax: (44) 1603-482-409
CR50.Man.07.00 11/30/00 6:16 PM Page 32
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Wavetek CR50 User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI