LH247HV

LG LH247HV, LHN247HV, LUU247HV LUU247HV Submittal

  • Hello! I am an AI chatbot trained to assist you with the LG LH247HV LUU247HV Submittal. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
SingleZoneHighStaticDuct
LH247HV
Page1of3
SB_SZ_HS_Ducted_LH247HV_02_17
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
Performan ce:
Cooling(MinRatedMax,Btu/h)
9,700‐24,000‐26,700
SEER/EER
17.0
/
12.0
Cooling:
Heating:
Heating(MinRatedMax,Bt u/h)
10,900‐27,000‐30,000
HSPF
10.0
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB
Indoor:
70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB
Outdoor:
47°FDB/43°FWB
Electrical:
MCA(A )
18.1
MOP(A)
30
FanMotor(A)
0.6
CoolingRatedAmps(A)
15.1
HeatingRatedAmps(A)
15.1
CoolingPowerInput(kW)
2.00
HeatingPowerInput(kW)
2.28
Piping:
LiquidLine(in,OD)
3/8
AdditionalRefrigerant(oz/ft)
0.43
MaxElevation(ft)
98
MaxPipeLength(ft)²
164
VaporLine(in,OD)
5/8
Features:
•ESPcontrol
•Hotstart
•Inverter(variable
speedfan)
•Internal
condensatepump
•Autorestart
•Controllock
OperatingRange:
OutdoorUnit:
IndoorUnit:
UnitData:
RefrigerantType/Control
R410A/E EV
RefrigerantCharge(lbs)
4.4
Fan:
Notes:
1.Acceptableoperangvoltage:187V253V.
2.Pipinglengthsareequivalent.
3.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
4.Maximumstacpressuremayresultinreducedairow(CFM).
5.Allpower/communicationcabletobeminimum18Americanwir egage(AWG),4conductor,
stranded,shieldedorunshieldedwir
eandmustcomplywithapplicablelocalandnationalcode.
Ifshielded,thewiremustbegroundedtothec hassisattheoutdoorunitonly.
6.SeeEngineeringManualforsensibleandlatentcapacies.
7.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
8.Theindooruni
tcomeswithadryheliumcharge.
9.Thisdataisrated0abovesealevel,with25ofrefrigerantlineanda0leveldierence
betweenoutdoorandindoorunits.
10.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
11.Iftheoptionallowambientwindbaffle(ZL
ABGP04A) isused,onewindbaffleisrequiredfor
eachODUfan.
Motor/Drive
BrushlessDigitallyControlled/Direct
ODUNetWeight(lbs)
133
ODUShippingWeight(lbs)
146
IDUNetWeight(lbs)
73
IDUShi ppingWeight(lbs)
95
FanSpeeds(Fan/Cooling/Heating)
3/3/3
FanQuantity(ODU+IDU)
1+1
Heating(°FWB)
064
Cooling(°FWB)
5777
SEER‐SeasonalEnergyEfficiencyRating EER‐EnergyEfficiencyRating
HSPF‐HeatingSeasonalPerformanceFactor
MOP‐MaximumO vercurrentProtection MCA‐MinimumCircuitAmpacity
ACEz
‐PQCSZ250S0
LGMultiSITE™CRC1Controller‐PREMTBVC0
DryContactforThermostat‐PDRYCB300
O
p
tionalAccessories
(
soldse
p
aratel
y)
PQRCVCL0QW
IncludedAccessories:
•SimpleControllerwithMode(White)‐PQRCVCL0QW
Compressor(A)
13.5
DehumidificationRate(pts/hr)
7.0
ODUAirCirculation(CFM)
2048
IDUAirCirculationH/M/L(CFM)
688/618/530
DefaultExternalStaticPr essure(inwg)
0.39
Cooling(°FDB)
5118
Heating(°FDB)
5981
PowerSupply(V¹/Hz/Ø)
208230/60/1
ODUSoundPressureMax(Cool/Heat) ±3dB( A)³
48/52
IDUSoundPressure(H/M/L)±3dB( A) ³
38/36/35
PipeLength(noadd'lRefrigerant,ft)
25
IndoorUnit(IDU)‐LHN247HVOutdoorUnit(ODU)‐LUU247HV
•Groupcontrol
•Timer(on/o)
•Sleepmoden
HighEfficiencyFilterBoxforBRHSDChassis‐ZFBXBR01A
DynamicV82VLLowP rofileAirCleane r‐ZPL MV201A
DynamicV84VLLowP rofileAirCleane r‐ZPL MV402A
ODU/IDUFanType
Propeller/Sirocco
MinimumESP/FanSettingValue
0.01/82
MaximumESP/FanSettingValue
0.78/159
PI485‐PMNFP14A1
LowAmbientWindBaffle(coolingoperationto0°F)‐ZLABGP04A¹¹
JobName/Location:
Ta g#:
Date:
PONo.:
SingleZoneHighStaticDuct
Page2of3
SB_SZ_HS_Ducted_LH 247HV_02_17
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
OutdoorUnit
(
ODU
)
‐LUU247HV
JobName/Location:
Ta g#:
Date:
PONo.:
SingleZoneHighStaticDuct
Page3of3
SB_SZ_HS_Ducted_LH 247HV_02_17
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
IndoorUnit
(
IDU
)
‐LHN247HV
/