Bertazzoni PRO304GASX Installation, Use and Care Manual

Category
Cookers
Type
Installation, Use and Care Manual

This manual is also suitable for

1
INSTALLATION,USE&CAREMANUAL
FREESTANDINGGASRANGES
Models
PRO30 4 GAS X [M7S0GNU7X(2,5)A]
Models
PRO30 4 GAS AR [M7S0GNU7S(2,5)A]
Models
PRO30 4 GAS BI [M7S0GNU7W(2,5)A]
Models
PRO30 4 GAS NE M7S0GNU7N(2,5)A]
Models
PRO30 4 GAS RO [M7S0GNU7R(2,5)A]
Models
PRO30 4 GAS VI [M7S0GNU7L(2,5)A]
cod.310813
2
BERTAZZONISpA
ViaPalazzina8
42016GuastallaRE
ITALY
WWW.BERTAZZONIITALIA.COM
FromthedeskofthePresident
DearnewownerofaBertazzoniproduct,
Iwanttothankyouforchoosingoneofour
beautifulPROranges.Weknowthatyouhavemany
brandsandproductstochoosefromandweare
thrilledthatyouhavedecidedtotakeonwofyour
productsintoyourhome.
Wetake
asmuchprideinmakingourrangesaswe
hopeyouwillinowningthem.Myfamilystarted
manufacturingcookingappliancesin1882.Eachof
ourproductsisablendofItaliandesignfinessand
superiorappliancetechnolo gy.Whilewecannot
replaceyouruniquetalentatcookingdelicious
recipes
foryourself,yourfamilyandyourfriends,
wetryourbesttomakecookingeasier,more
effectiveandmorefun.
Ourappliancesaredesignedaccordingtothe
strictestsafetyandperformancestandardforthe
EuropeanandtheNorthAmericanmarket.We
followthemostadvancedmanufacturing
philosophy.Eachapplianceleavesthe
factoryafter
thoroughqualityinspectionandtesting.Our
distributorsandourservicepartnersarereadyto
answeranyquestionsyoumayhaveregardinghow
toinstall,useandcareforyourBertazzoniproduct.
Thismanualwillhelpyoulearntousetheproduct
inthesafestandmosteffectivemanner
andcare
foritsothatitmaygiveyouthehighestsatisfaction
foryearstocome.
Themanualalsoincludesdirectionsforthe
professionalinstallerthatwillinstalltheproductin
yourhome.Werecommendusingfactorytrained
professionalsforthedelicatetaskofinstallingand
testingappliancesinyour
home.Pleasecall
CustomerServiceat(800)ifyouneedhelplocating
afactorytrainedprofessionalinstallerinyourarea.
Pleasekeepthismanualforfutureuse.
Grazie!
3
TABLEOFCONTENTS
WARRANTYANDSERVICE.........................................................................................................................4
CUSTOMERSERVICE.......................................................................................................................................................4
REPLACEMENTPARTS....................................................................................................................................................4
IMPORTANTSAFETYINFORMATION.........................................................................................................5
PRODUCTSPECIFICATIONS........................................................................................................................6
BEFOREINSTALLATION..............................................................................................................................7
INSTALLATION
INSTALLINGTHELEGS...............................................................................................................................8
INSTALLINGTHEWORKTOPFRONTGUARD...............................................................................................8
INSTALLINGTHEBACKGUARD...................................................................................................................9
INSTALLINGTHEANTITIPSTABILLTYDEVICE...........................................................................................10
INSTALLATIONREQUIREMENTS...............................................................................................................10
ELECTRICAL..................................................................................................................................................................10
GAS...............................................................................................................................................................................10
INSTALLATIONADJACENTTOKITCHENCABINETS....................................................................................11
EXHAUSTHOODINSTALLATION..............................................................................................................11
ELECTRICALCONNECTION.......................................................................................................................12
WIRINGDIAGRA M........................................................................................................................................................12
GASCONNECTION...................................................................................................................................13
PRESSUREREGULATOR................................................................................................................................................14
GASCONVERSION...................................................................................................................................15
STEP1:PRESSUREREGULATOR....................................................................................................................................15
STEP2:SURFACEBURNERS..........................................................................................................................................16
STEP3:MAINOVENBURNER.......................................................................................................................................16
STEP4:BROILERBURNER.............................................................................................................................................17
STEP5:VISUALCHECKS................................................................................................................................................18
STEP6:MINIMUMFLAMEADJUSTMENT.....................................................................................................................19
INSTALLATIONCHECKLLST.......................................................................................................................21
FINALPREPARATION...............................................................................................................................21
USERMANUAL
ROOMVENTILATION...............................................................................................................................22
SURFACEBURNERLAYOUT...................................................................................................................... 22
SURFACECOOKING.................................................................................................................................23
SYMBOLS......................................................................................................................................................................23
SURFACEBURNEROPERATION....................................................................................................................................23
TIPSFORUSINGBURNERSCORRECTLY.........................................................................................................................24
TIPSFORUSINGPANSCORRECTLY...............................................................................................................................24
OVENCOOKING......................................................................................................................................25
SYMBOLS......................................................................................................................................................................25
OVENSHELVES.............................................................................................................................................................25
GASOVENOPERATION.................................................................................................................................................26
CONVECTIONCOOKING...............................................................................................................................................27
COOKINGWITHTHEGASBROILER...............................................................................................................................27
MAINTAININGYOURRANGE...................................................................................................................28
REPLACINGTHEOVENLIGHTBULB..............................................................................................................................28
COOLINGFANFAILURE.................................................................................................................................................28
CLEANINGYOURRANGE.........................................................................................................................28
IMPORTANTAPPLIANCEINFORMATION.................................................................................................30
4
WARRANTYANDSERVICE
AllBertazzoniproductscarrya2yearpartsandlaborwarranty.
ServiceonallBertazzoniproductsshallbecarriedoutbyfactorytrainedprofessionalsonly.
ForwarrantyservicepleasecontactCustomerServiceatthenumbers indicatedbelow.
CUSTOMERSERVICE
English/spanishhotline (866)9050010
French(800)5617625
Fax(714)
4280040
Email
Mailingaddress
SERVICEPOWER
1503SouthCoastdrive
Suite320
CostaMesaCA92626
REPLACEMENTPARTS
OnlyBertazzonireplacementpartsmaybeusedinperformingserviceontheappliance.
Replacementpartsareavailablefromfactoryauthorizedpartsdistributors.
APWagner PHONE
716 961 7131 FAX716 856 4779
ReliablePartsPHONE 206 5758818 FAX206 5750910
CoastPHONE 800 821 0244 FAX604 321 6646
5
IMPORTANTSAFETYINFORMATION
PLEASEREADANDFOLLOWTHESEIMPORTANT
INSTRUCTIONSFORTHESAFETYOFYOURHOME
ANDOFTHEPEOPLELIVINGINIT.
SavethisManualforlocalelectricalinspector’s
use.
Readandsavetheseinstructionsforfuture
reference.
Observeallgoverningcodes,ordinancesand
regulations.
WARNING!
Iftheinformationinthismanualis
notfollowed
exactly,afireorexplosionmayresultcausing
propertydamage,personalinjuryordeath.
Donotstoreorusegasolineorotherflammable
substancesinthevicinity ofthisoranyother
appliance.
Installationandservicemustbeperformedbya
qualifiedinstaller,serviceagencyorthegas
supplier.
InMassachusetts:Allgasproductsmustbe
installedbya"Massachusetts"licensedplumber
orgasfitter.A"T"handletypemanualgasvalve
mustbeinstalledinthegaslineconnectedtothis
appliance.
WHATTODOIFYOUSMELLGAS
Donotlightanyappliance.
Donottouchanyelectricalswitch.
Donotuseanyphoneinyourbuilding.
Immediatelycallyourgassupplierfroma
neighbor’sphone.Followthegassupplier’s
instructions.
Ifyoucannotreachyourgassuppliers,callthe
firedepartment.
WARNING!
Readthisinstructionbookletbeforeinstalling
andusingtheappliance.
Themanufacturerwillnotberesponsiblefor
anydamagetopropertyortopersonscausedby
incorrectinstallationorimproperuseofthe
appliance.
The manufacturer reserves the right to make
changes to its products when considered
necessary and useful,
without affecting the
essentialsafetyandoperatingcharacteristics.
Thisappliancehasbeendesignedfornon
professional,domesticuseonly.
Donotusethisappliancetoheataroom.
Donotplaceanypotorpanontheopenoven
door.Thedoorismadeofglassanditcanbreak
ifloadedwithaweight.
Before beginning installation, please read these
instructionscompletelyandcarefully.
Do not remove permanently affixed labels,
warnings, or plates from the product. This may
void the warranty.‐Please observe all local and
nationalcodesandordinances.
Pleaseensuretherangeisproperlygrounded.
Theinstallershould
leavetheseinstructionswith
the consumer who should retain for local
inspector'suseandforfuturereference.
Theplugshouldalwaysbeaccessible.
Installation must conform with local codes or in
theabsenceofcodes,theNationalFuelGasCode
NSIZ223.1latest edition. Electrical installation
must be in accordance with
the National
Electrical Code, ANIS/NFPA70‐latest edition
and/orlocalcodes.INCANADA:Installationmust
be in accordance with the current CAN/CGA
B149.1 National Gas Installation Code or
CAN/CGAB 149.2, Propane Installation Code
and/orlocalcodes.Electricalinstallationmustbe
in accordance with the current CSA C22.1
Canadian Electrical Codes Part
1 and/or local
codes.
Installationofanygasfiredequipmentshouldbe
madeby alicensed plumber. Amanual gasshut
off valve must be installed in the gas supply li ne
ahead of the oven in the gasflow for safety and
easeofservice.
Warning!
This range can tip. Injury to persons could result.
Install anti-tip device shipped with range. See
Installation Instructions.
6
PRODUCTSPECIFICATIONS
Dimensions(insertdrawingsfront,sideandback
Weight
Burnerpower
Naturalgas
LPgas
Auxiliary 3730BTU/h 3750BTU/h
Semirapid 6000BTU/h 6300BTU/h
Rapid 10400BTU/h 11400BTU/h
Dualburner(inner) 2730BTU/h 2900BTU/h
Dualburner(outer) 15000BTU/h 16400BTU/h
Oven 14500BTU/h 14500BTU/h
broiler 12000BTU/h 12000BTU/h
7
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the abs ence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuel Gas Code AN SIZ223.1
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence oflocal codes, with the
National
ElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gas supply line. Do not bend or damage the
flexibleconnectorwhenmovingthe
appliance.
This appliance must be used with the pressure
regulator pr ovided. The regulator shall be
properlyinstalled inorder to be accessible when
theappliance isinstalled in itsfinallocation. The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”
female
pipe thread. The appropriate fitting must be
determined based on the size of your gas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
All opening and holes in the wall and floor, back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalveshallbeinstalledin an accessible
location in the gas
line external to the appliance
for the purpose of turning on or shutting off gas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it
shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmay affectotherventeda ppliances;in
each case it shall be installed in conformity with
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural
gas. For use with propane lp gas
please follow the conversion procedure
described on pg. 15. A step by step conversion
procedureisalsoincludedwitheach setoflpgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas appliance pressure regulator is 20’’
water
column(5kPa).
The minimum gas supply pressure for checking
theregulatorsettingshallbeatleast1“ w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
the appliance (this operating pressure is 4” w.c. 
(1.00kPa)forNaturalGasand11” w.c.(2.75kPa
forLPGas).
8
INSTALLINGTHELEGS
Bertazzonirangesmustbeusedonlywiththe
legsproperlyinstalled.
Fourheightadjustablelegsareshippedwiththe
rangeinthepolysterenecontainersituatedover
theappliance.
Before installing the legs, position the appliance
nearitsfinallocationas the legsarenotsuitable
formovingtheapplianceoverlong
distances.
After unpacking the range, raise it enough to
insert the legs in the appropriate receptacles
situated on the lower part of the appliance.
Lowertherangegentlytokeepanyun duestrain
fromlegsandmountinghardware.Ifpossibleuse
apalletorliftjackinsteadoftiltingthe
unit.
Adjust leg height to the desired level by twisting
the inside portion of the leg assembly until the
properheightis reached. Checkwith alevel that
thecooktopisperfectlylevel.
INSTALLINGTHEWORKTOP
FRONTGUARD
Toincreasetheclearancebetweenthefrontedge
of the worktop and the burners it is possible to
install the worktop frontguard shipped with the
appliance.
Toinstallthefrontguard,holditwiththepointed
edges looking up. Align the edges of the
frontguard with the appropriate receptacles in
the
bottomofthe worktop and press firmlyuntil
the frontguard is securely attached to the
worktop.
ATTENTION: once installed the frontguard may
only be removed by disassembling the worktop.
Attempting to remove the frontguard without
disassembling the worktop will result in
permanentdamagetotheworktop.
9
INSTALLINGTHEBACKGUARD
The backguard must be installed prior to
operation of the appli ance for appropriate
ventilationoftheovencompartment.
Thesuppliedbackguardisa2partassembly.The
box also contains a set of metal screws for
securingthebackguardtotheworktop.
Disassemblethebackguardandpositionthefront
part on the worktop. Align the screw holes with
the corresponding holes at the back of the
worktop.
If the holes are not aligned, partially loosen the
brackets att the back of the worktop as shown
below.

Install the front part of the backguard by
tighteningthe 2central screws fromthe top and
2lateralscrewsfromthebottom.
Positionthebackpartofthebackguardand
secureittotheworktoptightening4screwsfrom
thebottom.
Connectthebackandfrontpartoftheupstand.
Checkfortightassembly.
10
INSTALLINGTHEANTITIPSTABILlTY
DEVICE
Theantitipbracketshippedwiththerangemust
beproperlysecuredtotherearwallasshownin
thepircturebelow.
Theheightofthebracketfromthefloormustbe
determinedaftertherangelegshavebeen
adjustedtothedesiredheightandafterthe
rangehasbeenleveled.

Measurethedistancefromthefloortothe
bottomoftheantitipbracketreceptacleonthe
backoftheappliance.
Positionthetwoantitipbracketsonthewallat
thedesiredheightplus1/8"(0.32cm).The
bracketsmustbeplacedat2”5/16(6,0cm)from
theside
oftherange.Thedistancebetweenthe
twobracketis25”1/4(64cm).
Securethebracketstothewallwithappropriate
hardware.
Slidetherangeagainstthewalluntilthebrackets
arefullyinsertedintotheirreceptaclesonthe
backoftherange.
INSTALLATIONREQUIREMENTS
ELECTRICAL
Aproperlygroundedhorizontally‐mounted
electricalreceptacleshouldbeinstallednohigher
than3"(7.6cm)abovethefloor,nolessthan2”
(5cm)andnomorethan8”(20,3cm)fromthe
rightside(facingproduct).
Checkalllocalcoderequirements.
GAS
Anagencyapproved,properlysized
manualshut
offvalveshouldbeinstallednohigherthan3"
(7.6cm)abovethefloorandnolessthan2”(5
cm)andnomorethan8” (20.3cm)fromtheleft
side(facingproduct).
Toconnectgasbetweenshutoffvalveand
regulator,useagencyapproved,properlysized
flexible
orrigidpipe.Checkalllocalcode
requirements.
11
INSTALLATIONADJACENTTOKITCHEN
CABINETS
Thisrangemaybeinstalleddirectlyadjacentto
existingcountertophighcabinets(36"or91.5cm
fromthefloor).
Forthebestlook,theworktopshouldbelevel
withthecabinetcoun tertop.Thiscanbe
accomplishedbyraisingtheunitusingthe
adjustmentspindlesonthelegs.
ATTENTION:therangeCANNOT
beinstalled
directlyadjacenttokitchenwalls,tallcabinets,
tallappliances,orotherverticalsurfacesabove
36"(91.4cm)high.Theminimumsideclearance
insuchcasesis6"(15.2cm).
Wallcabinetswithminimumsideclearancemust
beinstalled18"(45.7cm)abovethecountertop
withcountertopheightbetween
35½”(90.2cm)
and37¼”(94.6cm).Themaximumdepthofwall
cabinetsabovetherangeshallbe13"(33.0cm)

EXHAUSTHOODINSTALLATION
ThisrangewillbestperformwhenusedwithPRO
lineBertazzoniexhausthoods.Thesehoodshave
been designed to work in conjunctio n with the
Bertazzoni range and have the same finish for a
perfectlook.
For maximum performance, the height of the
bottomofthehood from theworktop shouldbe
between 25 1/2" (65 cm) and 31 1/2" (80 cm).
This would typically result in the bottom of the
hoodbeing 611/2" (156.2 cm) to 67 1/2" (171.5
cm) above the floor. These measurements
provide for safe and efficient operation of the
hood.
Before installation of the exhaust hood,
consult
local or regional building and installation codes
foradditionalspecificclearancerequirements.
Refer to the range hood installation instructions
provided by the manufacturer for additional
information.
A 30” (76,2 cm)
B 36” (91,5 cm)
C 13” (33,0 cm)
D 18” (45,7 cm)
E 35”1/2(90,2 cm) / 37” ¼ (94,6 cm)
F 6” (15,2 cm)
G 6” (15,2 cm)
12
ELECTRICALCONNECTION
This unit is manufactured for a polarized,
grounded120volt/60Hz,16ampsystem.
Electricpowerconsumption is about150W.
The minimum of 102 VAC is required for proper
operationofgasignitionsystems.
The circuit must be grounded and properly
polarized.
The unit is equipped witth a SJT power
cord. In
case of replacement, the power cord shall be
replaced with one of the same type, size and
length.
ELECTRICALGROUNDING
Thisapplianceisequippedwithathreeprong
plugforyourprotectionagainstshockhazardand
shouldbepluggeddirectlyintoaproperly
groundedsocket.Donotcut
orremovethe
groundingprongfromthisplug.
WARNING!
ELECTRICALSHOCKHAZARD
Disconnectelectricalpowe ratthecircuit
breakerboxorfuseboxbeforeinstallingthe
appliance.
Provideappropriategroundfortheappliance.
Usecopperconductorsonly.
Failuretofollowtheseinstructionscouldresult
inseriousinjuryordeath
CAUTION
Labelallwirespriortodisconnectingwhen
servicingcontrols.Wiringerrorscancause
improperanddangerousoperation.
Verifyproperoperationafterservicing.
WIRINGDIAGRAM
13
GASCONNECTION
Allgasconnectionsmustcomplywithnational
andlocalcodes.Thegassupplyline(service)
mustbethesamesizeorgreaterthantheinlet
lineoftheappliance.Thisrangeusesa1/2"NPT
inlet(seedrawingbelowfordetailsofgas
connection).Onallpipejointsuseappropriate
sealant
resistanttogas.
Thisrangecanbeused withNaturalor
LP/Propanegas.Therangeisshippedfromthe
factoryforusewithnaturalgas.
ForLP/propanehouseholdinstallation,the
appliancemustbeconvertedbythedealer,bya
factorytrainedprofessionalorbyaqualified
licensedplumberorgas
servicecompany.
Gasconversionisimportantforsafeandeffective
useoftheappliance.Itistheresponsibilityofthe
dealerandtheowneroftherangetoperformthe
appropriategasconversionfollowingthe
directionsofthemanufacturer.
THEGASCONVERSIONPROCEDUREISDESCRIBED
INTHISMANUALANDINTHE
PACKAGE
CONTAININGTHECONVERSIONNOZZLES
SHIPPEDWITHEVERYRANGE.
Pleaseprovidetheservicepersonwiththis
manualbeforeworkisstartedontherange.
WARNING!
DONOTUSEANOPENFLAMEWHENCHECKING
FORLEAKS!
Leaktestingoftheapplianceshallbeconducted
accordingtothemanufacturer'sinstructions.
Beforeplacing
theovenintooperation,always
checkforleakswithsoapywatersolutionor
otheracceptablemethod.
MANUALSHUTOFFVALVE
THISVALVEISNOTSHIPPEDWITHTHEAPPLIANC
ANDMUSTBESUPPLIEDBYTHEINSTALLER.
Themanualshutoffvalvemustbeinstalledin
thegasservicelinebetweenthe
gashookupon
thewallandtheapplianceinlet,inaposition
whereitcanbereachedquicklyintheeventofan
emergency.
InMassachusetts:A'T'handletypemanualgas
valvemustbeinstalledinthegassupplylineto
thisappliance.
FLEXIBLECONNECTIONS
In case of
installation with flexible couplings
and/or quickdisconnect fittings, the installer
must use a heavyduty, AGA designcertified
commercial flexible connector of at least 1/2"
(1.3 cm) ID NPT (with suitable strain reliefs) in
compliance with ANSI Z21.41 and Z21.69
standards.
In Massachusetts: The unit must be installed
witha
36"(3foot)longflexiblegasconnector.
InCanada:useCAN16.1088metalconnectors
forgasappliancesandCAN16.9M79quick
disconnectdeviceforusewithgasfuel.
PRESSURETESTPOINTSTOPPERVALVE
To avoid gas leaks, the pressure testpoint
stoppervalveandgasketsupplied
withtherange
mustbeinstalledonthegasfittingatthebackof
therangeaccordingtothediagrambelow.

14
PRESSUREREGULATOR
Sinceservicepressuremayfluctuatewithlocal
demand,everygascookingappliancemustbe
equippedwithapressureregulatoronthe
incomingservicelineforsafeandefficient
operation.
Thepressureregulatorshippedwiththe
appliancehashastwofemalethreads½”NPT.
Theregulatorshallbeinstalled
properlyinorder
tobeaccessiblewhentheapplianceisinstalledin
itsfinalposition.
Manifoldpressureshouldbecheckedwitha
manometerandcomplywiththevaluesindicated
below:
Naturalgas4.0"W.c.P.
LP/Propane11.0"W.C.P.
Incominglinepressureupstreamfromthe
regulatormustbe1"W.c.P.higherthanthe
manifoldpressureinordertocheckthe
regulator.
Theregulatorusedon
thisrangecanwithstanda
maximuminputpressureof1/2PSI(14.0"W.c.P.)
Ifthelinepressureexceedsthatamount,astep
downregulatorisrequired.
The appliance, its individual shutoff valve, and
the pressure regulator must be disconnected
from the gas line during any pressure testing of
that system
at pressures in excess of 1/2 psig
(3.45kPa).
The individuaL manual shutoff valve must be in
the OFF position during any pressure testing of
the gas supply piping system at test pressures
equaltoorlessthan½psig(3.45kPa).
15
GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factorytrainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2. Surfaceburn ers
3. Mainovenburner
4. Broilerburner
5. Visualcheckspriortoclosureofovenbottom
panel
6. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegasconversion,locatethe
packagecontainingthereplacementnozzle
shippedwitheveryrange.IMPORTANT:Each
nozzlehasanumberindicating itsflowdiameter
printedonthebody.Consultthetableonpage20
formatchingnozzlestoburners.
Savethenozzlesremovedfromtherangefor
futureuse.
STEP1:PRESSUREREGULATOR
Thepressureregulatorsuppliedwiththe
applianceisaconvertibletypepressure regulator
forusewithNaturalGasatanominaloutlet
pressureof4”w.c.orLPgasatanominaloutlet
pressureof11”w.c.anditisprearrangedfrom
thefactorytooperatewithoneofthese
gas/pressureasindicatedinthelabels
affixedon
theappliance,packageandInstructionbooklet.
Toconverttheregulatorforusewithotherliquid
propaneLPgas:
1. Unscrewbyhandtheuppercapofthe
regulator,removethewhiteplastic
attachmentfromthecap,reverseits
directionandscrewitagainfirmlyagainstthe
cap.The
whiteplasticattachmenthasarrows
indicatingthepositionfornaturalgas(NAT)
andLPgas(LP).
2. Screwbyhandthemetalcapintheoriginal
positionontheregulator.
16
STEP2:SURFACEBURNERS
Toreplacethenozzlesofthesurfaceburners,lift
up the burners and unscrew the nozzles shipped
withtherangeusinga7mm{sochetwrench).
Replacenozzlesusingtheconversionsetsupplied
with the range or by a Bertazzoni authorized
parts warehouse. Each nozzle has a
number
indicating itsflow diameter printedon the body.
Consultthetableonpage20formatchingnozzles
toburners.
STEP3:MAINOVENBURNER
Toreplacethenozzlesofthemain ovenburner,
startbyremovingthebottompaneloftheoven.
Loosenthescrewlocatedontherightsideofthe
burnerandpullouttheburnerfromitssupport.
ATTENTION:payextraattentiontoavoiddamage
totheigniterandthermocouple.
17
Unscrew the nozzle located inside the gasfitting
usinga7mm[socketwrench].
Replace the nozzle using the conversion set
supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on
page 20 for
matchingnozzlestoburners.
Donotneedairadjustmentontheovenburner.
STEP4:BROILERBURNER
Loosenthescrewandpullouttheburnerfromits
support.
ATTENTION:payextraattentiontoavoiddamage
totheigniterandthermocouple.
Using a 7 mm [name of the tool] unscrew the
nozzle. Replace the nozzle using the conversion
set supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching
nozzlestoburners.
AdjustthegapXbysettingittofullyopen
position.
18
STEP5:VISUALCHECKS
Beforereinstallingthebottompanel,the
followingvisualcheckmustbeperformedto
ensurethattheconversionhasbeencarriedout
properlyandwithoutdamagetoother
componentsoftherange.
A) CONNECTIONOFTHERMOCOUPLESTO
THERMOSTAT
Thethermocouplesforbothbroilerandmain
ovenburner
areconnectedtothesamemagnet.
Tightgentlythetwoconnectionsalternating
actiononthetwonuts.Donotfullytightenone
thermocouplebeforehavingstartedtotighten
thesecondone.
B) OVENIGNITERANDTHERMOCOUPLE
POSITION
Theappropriategapbetweenthetipofthespark
plugorthermocoupleandtheburnershallbe
approximately1/8’’.
Thetipofthesparkplugorthermocouplemust
fullyoverlapatleastthefirstgasemissionholeof
theburner.
Afterperformingallthesevisualchecks,reinstall
thebottompaneloftheovencompartmentand
proceedtosettingtheminimumforeach
burner.
19
STEP6:MINIMUMFLAMEADJUSTMENT
WARNING!
Theseadjustmentsshouldbemadeonlyforuse
oftheappliancewithnaturalgas.Forusewith
liquidpropanegas,thechokescrewmustbe
fullyturnedinaclockwisedirection.
SURFACEBURNERS
1. Light one burner at a time and set the knob
totheMINIMUMposition(smallflame).
2. Removetheknob.
3. The range is equipped with a safety valve.
Using a smallsize slotted screwdriver, locate
the choke valve on the valve body and turn
the choke screw to the right or left until the
burnerflameisadjustedto
desiredminimum.
4. Make sure that the flame does not go out
when switching quickly from the MAXIMUM
totheMINIMUMposition.
OVENBURNER
1. Settheoventemperaturecontrolknobtothe
MAXIMUMsetting.
2. Closetheovendoorandoperatetheovenfor
atleast10minutes.
3. Set the knob to the MINIMUM setting
(correspondingto270°F/132°C).
4. Removetheknob.
5. With a slotted screwdriver turn the choking
screw(bypass screw at the left side of the
thermostat bar) and, while observing the
flame at the same time through the bottom
oven porthole, evaluate the consistency of
the flame so it remains on when switching
quickly from MINIMUM to MAXIMUM
setting.
Broiler burner: the broiler burner always
operates at maximum, therefore no minimum
adjustmentisrequired.
20
Models
PRO30 4 GAS X [M7S0GNU7X(2,5)A]
Models
PRO30 4 GAS AR [M7S0GNU7S(2,5)A]
Models
PRO30 4 GAS BI [M7S0GNU7W(2,5)A]
Models
PRO30 4 GAS NE M7S0GNU7N(2,5)A]
Models
PRO30 4 GAS RO [M7S0GNU7R(2,5)A]
Models
PRO30 4 GAS VI [M7S0GNU7L(2,5)A]
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Rear L
0,92
NG 4”
3750 1098
900 264 Regulated
0,56
LP (Propane) 11”
3750 1098
900 264 0,29
Semi-Rapid Front R
1,17
NG 4”
6000 1759
1500 439 Regulated
0,73
LP (Propane) 11”
6300 1845
1500 439 0,36
Rapid Rear R
1,55
NG 4”
104003046
2500 732 Regulated
0,98
LP (Propane) 11”
114003339
2500 732 0,47
Front L Inner
0,80
NG 4”
2730 799
900 264 Regulated
Dual Burner
0,50
LP (Propane) 11”
2900 849
900 264 0,29
Front L Outer
N°2x1,30
NG 4”
150004394
4500 1318 Regulated
N°2x0,83
LP (Propane) 11”
164004804
4500 1318 0,65
Oven Oven 1,85 NG 4” 14500 4248 3500 1025 Regulated
downside 1,10 LP (Propane) 11” 14500 4248 3500 1025 0,54
Broiler Oven 1,70 NG 4” 12000 3516 Only Max Only Max No by-pass
upside 0,98 LP (Propane) 11” 12000 3516 Only Max Only Max No by-pass
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

Bertazzoni PRO304GASX Installation, Use and Care Manual

Category
Cookers
Type
Installation, Use and Care Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI