Vista ViP2 VK2-1080VFD Installation and User Manual

Category
Security cameras
Type
Installation and User Manual
VK2-1080VFD
Installation and user manual
2
3
WARNING
CAUTION
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user
to the presence of un-insulated "dangerous voltage" within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying the
appliance.
PRECAUTIONS
Safety -------------------------------------- Installation -------------------------------
Should any liquid or solid object fall into the cabinet,
unplug the unit and have it checked by the qualified
personnel before operating it any further.
Unplug the unit from the wall outlet if it is not going to
be used for several days or more. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
Allow adequate air circulation to prevent internal heat
build-up. Do not place the unit on surfaces (rugs,
blankets, etc.) or near materials(curtains, draperies)
that may block the ventilation holes.
Height and vertical linearity controls located at the rear
panel are for special adjustments by qualified
personnel only.
Do not install the unit in an extremely hot or humid
place or in a place subject to excessive dust,
mechanical vibration.
The unit is not designed to be waterproof.
Exposure to rain or water may damage the unit.
Cleaning ---------------------------------
Clean the unit with a slightly damp soft cloth.
Use a mild household detergent. Never use strong
solvents such as thinner or benzene as they might
damage the finish of the unit.
Retain the original carton and packing materials for
www.hitron.co.kr
4
safe transport of this unit in the future.
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER'S AUTHORITY TO OPERATE THE
EQUIPMENT.
CE COMPLIANCE STATEMENT
WARNING: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
5
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for replacement of the
obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified
by the manufacturer, or sold with the apparatus. When a cart is
used, use caution when moving the cart/apparatus combination
to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused
for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been
moisture, does not operate normally, or has been dropped.
15. CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED
SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK DO
NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE
OPERATING INSTRUCTIONS UNLESS YOU QRE QUALIFIED TO DO SO.
16. Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed Class 2
power source only.
17. ITE is to be connected only to PoE networks without routing to the outside plant.
6
7
Contents
1. Description ...................................................................................................... 8
1.1 Components .............................................................................................. 8
1.2 Key Features ............................................................................................. 9
2. Installation ..................................................................................................... 10
2.1 Over View .................................................................................................10
2.2 Base installation ........................................................................................11
2.3 Connection................................................................................................12
2.4 Network Connection and IP assignment .................................................13
3. Operation ....................................................................................................... 14
3.1 Minimum conditions for using web browser ...............................................14
3.2 Accessing the IP camera ..........................................................................15
3.3 Access from the internet ...........................................................................16
3.4 Setting the admin password over a secure connection .............................16
3.5 Live View Page .........................................................................................17
3.6 Menu Configuration ...................................................................................19
3.6.1 Basic Configuration ............................................................................................. 20
3.6.2 Video & Image ..................................................................................................... 25
3.6.3 Event.................................................................................................................... 31
3.6.4 System ................................................................................................................. 44
3.6.5 About ................................................................................................................... 60
3.8 Playback for Micro SD card .......................................................................61
3.9 Help ..........................................................................................................63
3.10 Resetting to the factory default settings ..................................................63
4. Appendix ....................................................................................................... 64
4.1 Troubleshooting ........................................................................................64
4.2 Alarm Connection .....................................................................................65
4.3 Preventive Maintenance............................................................................65
8
1. Description
This manual applies to the VK2-1080VFD.
The VK2-1080VFD supports the network service for a sensor image with progressive scan, which can
be monitored on a real-time screen regardless of distances and locations. By using its dedicated
program, many users are able to have an access to the VK2-1080VFD at once or a single user can
monitor various VK2-1080VFD s at the same time. It also enables users to play, store and retrieve a
monitoring image by using a PC. All the settings and real-time monitoring screens are also provided
through an access to the web.
The VK2-1080VFD is fully featured for security surveillance and remote monitoring needs. It is based
on the DSP compression chip, and makes it available on the network as real-time, full frame rate
Motion JPEG and H.264 (or MPEG-4) video streams.
The alarm input and alarm output can be used to connect various third party devices, such as, door
sensors and alarm bells.
1.1 Components
The system comes with the following components:
Camera unit Installation CD Installation Guide Template Sheet Accessory Kit
Note: Check your package to make sure that you received the complete system, including all
components shown above.
9
1.2 Key Features
Brilliant video quality
The VK2-1080VFD offers the highly efficient H.264 video compression, which drastically reduces
bandwidth and storage requirements without compromising image quality. Motion JPEG is also
supported for increased flexibility.
Dual streams
The VK2-1080VFD can deliver dual video streams simultaneously at full frame rate in all
resolutions up to Full HD (1920x180) using Motion JPEG and H.264 (or MPEG-4). This means
that 2 video streams can be configured with different compression formats, resolutions and frame
rates for different needs.
Image setting adjustment
The VK2-1080VFD also enables users to adjust image settings such as contrast, brightness and
saturation to improve images before encoding takes place.
Intelligent video capabilities
The VK2-1080VFD includes intelligent capabilities such as enhanced video motion detection. The
encoder’s external inputs and outputs can be connected to devices such as sensors and relays,
enabling the system to react to alarms and activate lights or open/close doors.
Resolution
The VK2-1080VFD supports up to 30fps@1920x1080
Micro-SD Recording support
The VK2-1080VFD also supports a micro-SD memory slot for local recording with removable
storage.
Improved Security
The VK2-1080VFD logs all user access, and lists currently connected users. Also, its full frame
rate video can be provided over HTTPS.
Power over Ethernet
Support for Power over Ethernet (IEEE802.3af) enables the unit, as well as the camera module
that is connected to it, to receive power through the same cable as for data transmission. This
makes for easy installation since no power outlet is needed.
ONVIF
This is a global interface standard that makes it easier for end users, integrators, consultants,
and manufacturers to take advantage of the possibilities offered by network video technology.
ONVIF enables interoperability between different vendor products, increased flexibility, reduced
cost, and future-proof systems.
10
2. Installation
2.1 Over View
Front View
NO
Name
1
Lens
2
Connection Cable
Side View Bottom View
NO
Name
1
Micro SD Slot
2
Status LED
3
Alarm IO Terminal
Extension Cable
NO
Wire Colour
1
Red: DC12V
White: GND
2
Black
11
2.2 Base installation
Use the provided template to mark the required mounting and cable holes.
To remove dome cover, turn the dome cover counter clockwise until locators reach end of travel
and pull off. Push the liner in the direction of the arrow (three ‘OPEN’ marks) and pull it off.
Fasten Mounting screws (2X) and align the dome camera as shown above. Turn the dome camera
in a clockwise direction to lock it in position.
Secure the dome cover with the locking screw provided.
12
2.3 Connection
Connecting to the RJ-45
Connect a standard RJ-45 cable to the network port of the VK2-1080VFD . Generally a
cross-over cable is used for directly connection to PC, while a direct cable is used for connection
to a switch or hub.
Connecting Alarms
AI(Alarm In) :
You can use external devices to signal the VK2-1080VFD to react on events. Mechanical or
electrical switches can be wired to the AI (Alarm In) and G (Ground) connectors in the bottom.
G(Ground) :
Connect the ground side of the alarm input and/or alarm output to the G (Ground) connector.
Alarm Out :
The VK2-1080VFD can activate external devices such as buzzers or lights. Connect the device
to the AO (Alarm Out) and G (Ground) connectors.
Connecting Video Output for set up only
Video Output is used for an easy zoom and focus
control when commissioning the camera. Set Video
Switch (SW2 on the board) to On position to output
the video signal. Video Output is restricted to
VGA(640x480) resolution.
Connect your Video cable unit to J5 on the board, as
shown on the adjacent illustration.
Caution: After the camera has been focused, you must set Video Switch SW2 to the OFF
position to provide the best performance of the VK2-1080VFD .
Connecting the Power (If not using PoE)
Connect the power of 12VDC 330mA for the camera. Connect the positive (+) pole to the ‘+’
position and the negative (-) pole to the -‘position.
13
2.4 Network Connection and IP assignment
When a VK2-1080VFD is first connected to the network it has a default IP address of 192.168.30.220
So, it will probably be necessary to allocate an IP address to the device with the “Smart Manager”
utility on the CD.
1. Connect the VK2-1080VFD / device to the network and power up.
2. Start SmartManager utility, available on the supplied CD, the main window will be displayed, after
a short while any network devices connected to the network will be displayed in the list.
3. Select the camera on the list and right click the mouse. You will see the pop-up menu as below.
4. Enter the appropriate IP address.
Note: For more information, refer to the Smart Manger User’s Manual.
14
3. Operation
Before powering the camera, installation must be complete. The camera completes a configuration
sequence taking approximately 40 seconds from powering up. Once completed the LED will be a
constant Green.
The VK2-1080VFD can be used with Windows operating system and browsers. The recommended
browsers are Internet Explorer, Safari, Firefox, Opera and Google Chrome.
NOTES
- To view streaming video in Microsoft Internet Explorer, set your browser to allow ActiveX controls.
- If the DHCP is enabled but the camera is not connected to a DHCP server, the camera will be set to
a default IP address of192.168.30.220 and will try to obtain an IP address from a DHCP server every
two seconds.
- Network and processor bandwidth limitations might cause the video stream to pause or appear
pixelated when an increased number of Web-interface users connect to the camera. Decrease the
images per second, resolution, compression, or bit rate settings of the Web-interface video streams to
compensate for network or processor limitations.
3.1 Minimum conditions for using web browser
The minimum system requirements to use a Web browser with this IP camera are as follows:
- CPU: Pentium® 4 microprocessor, 2.0GHz
- Operational System: Windows XP® or Windows Vista® or Windows7®
- System Memory: RAM 512 Mbyte
- Ethernet: 100 Mbit
- Video Resolution: 1024(Horizontal) x 768(Vertical) pixels or higher
- Internet Explorer® 7 or later
- ActiveX® 1.0.0.13 or later
15
3.2 Accessing the IP camera
1. Open Web browser
2. Type IP address: - The default IP address is 192.168.30.220
NOTE
- If you do not know the camera’s IP address, install the SmartManager® utility software available on
the CD supplied with the product. The utility software will locate the assigned Model name, Host
name, MAC address, IP address, Version and others.
- Refer to the SmartManager® utility software manual for more detail.
3. Log On to the camera
Default User = admin, default password = admin
- Click the Live View icon for default live image view or the Setup icon to change the configuration
values.
4. The encoder’s Live View page appears in your browser.
16
3.3 Access from the internet
The VK2-1080VFD is accessible on your local network (LAN). To access the camera from the Internet
you must configure your broadband router to allow incoming data traffic to the camera. To do this,
enable the NAT-traversal feature, which will attempt to automatically configure the router to allow
access to the camera. This is enabled from Setup > System > Network > NAT.
For more information, please see “System>Network>NAT” of User’s Manual.
3.4 Setting the admin password over a secure connection
To gain access to the product, the password for the default administrator user must be set. This is
done in the “Admin Password” dialog, which is displayed when the VK2-1080VFD is accessed for the
setup at the first time. Enter your admin name and password, set by the administrator.
Note: The default administrator username and password is “admin”. If the password is lost, the VK2-
1080VFD must be reset to the factory default settings. See “Resetting to the Factory Default Settings”
for more details.
To prevent network eavesdropping when setting the admin password, this can be done via an
encrypted HTTPS connection, which requires an HTTPS certificate (see note below).
To set the password via a standard HTTP connection, enter it directly in the first dialog shown below.
To set the password via an encrypted HTTPS connection, see System > Security > HTTPS”.
Note: HTTPS (Hypertext Transfer Protocol over SSL) is a protocol used to encrypt the traffic between
web browsers and servers. The HTTPS certificate controls the encrypted exchange of information.
17
3.5 Live View Page
The live view page comes in eight screen modes like 1920x1080, 1280x1024, 1280x720,
704x480(576), 640x480, 352x240(288), and 320x240. Users are allowed to select the most suitable
one out of those modes. Please, adjust the mode in accordance with your PC specifications and
monitoring purposes.
1) General controls
Live View Page Search & Playback Page Setup Page Help Page
The video drop-down list allows you to select a customized or pre-programmed
video stream on the live view page. Stream profiles are configured under Setup > Basic
Configuration > Video & Image. For more information, please see Basic Configuration > Video &
Image” of User’s Manual.
The resolution drop-down list allows you to select the most suitable one
out of video resolutions to be displayed on live view page.
The protocol drop-down list allows you to select which combination of
protocols and methods to use depends on your viewing requirements, and on the properties of
your network.
18
2) Control toolbar
The live viewer toolbar is available in the web browser page only. It displays the following buttons:
The Stop button stops the video stream being played. Pressing the key again toggles the
start and stop. The Start button connects to the VK2-1080VFD or start playing a
video stream.
The Pause button pause the video stream being played.
The Snapshot button takes a snapshot of the current image. The location where the
image is saved can be specified.
The digital zoom activates a zoom-in or zoom-out function for video image on the live
screen.
The Full Screen button causes the video image to fill the entire screen area. No other
windows will be visible. Press the 'Esc' button on the computer keyboard to cancel full
screen view.
The Manual Trigger button activates a pop-up window to manually start or stop the event.
Use this scale to control the volume of the speakers.
Use this scale to control the volume of the microphone.
Use this scale to control the volume of the speakers and microphones.
3) Video Streams
The VK2-1080VFD provides several images and video stream formats. Your requirements and
the properties of your network will determine the type you use.
The Live View page in the VK2-1080VFD provides access to H.264, MPEG-4 and Motion JPEG
video streams, and to the list of available video streams. Other applications and clients can also
access these video streams/images directly, without going via the Live View page.
19
3.6 Menu Configuration
This section describes how to configure the VK2-1080VFD, and is intended for product Administrators,
who have un-restricted access to all the Setup tools; and Operators, who have access to the settings
for Basic, Live View, Video & Image, Audio, Event, and System Configuration.
You can configure the VK2-1080VFD by clicking Setup in the top right-hand corner of the Live View
page. Click on this page to access the online help that explains the setup tools
When accessing the VK2-1080VFD for the
first time, the “Admin Password” dialog
appears. Enter your admin name and
password, set by the administrator.
Note: If the password is lost, the VK2-
1080VFD must be reset to the factory
default settings. See Resetting to the
Factory Default Settings
20
3.6.1 Basic Configuration
1) Users
User access control is enabled by default. An administrator can set up other users, by giving these
user names and passwords. It is also possible to allow anonymous viewer login, which means that
anybody may access the Live View page, as described below:
The user list displays the authorized users and user groups (levels):
User Group
Authority
Guest
Provides the lowest level of access, which only allows access to
the Live View page.
Operator
An operator can view the Live View page, create and modify
events, and adjust certain other settings. Operators have no
access to System Options.
Administrator
An administrator has unrestricted access to the Setup tools and
can determine the registration of all other users.
Enable anonymous viewer login: Check the box to use the webcasting features. Refer to
Video & Image” for more details.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66

Vista ViP2 VK2-1080VFD Installation and User Manual

Category
Security cameras
Type
Installation and User Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI