American Hearth Rushmore DVCT40CSP Gas Conversion LP to NAT Owner's manual

Type
Owner's manual

This manual is also suitable for

41057-0-0719 Page 1
INSTALLATION INSTRUCTIONS
DIRECT
-
VENT GAS FIREPLACE
WARNING
This conversion kit must be installed by an Empire Comfort Systems distributor (or other
qualied agency¹)*in accordance with the manufacturers instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualied agency performing this work assumes
responsibility for this conversion.
1National Fuel Gas Code Z223.1 (Latest Edition)
*The term “qualied individual, rm, corporation or company which either in person or through
a representative is engaged in and is responsible for (a) the installation of gas piping or (b)
the connection, installation repair, or servicing of equipment, who is experienced in such
work, familiar with all precautions required, and has complied with all the requirements of the
authority having jurisdiction.
CHECK SAFETY SHUTDOWN PERFORMANCE
WARNING
Perform the safety shutdown test anytime work is done on a gas system to avoid the possibility
of re or explosion with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilotgasowshouldstopwithin30seconds.
PARTS LIST
Part Description Conversion Kit Quantity Supplied
MainBurnerOrice,Front P184(#35) 1
MainBurnerOrice,Rear P213(#37) 1
SIT Gas Valve Conversion Kit R11381 1
Gas Conversion Label 1224 1
Target,Front 38042 1
Target,Rear 40647 1
TOOLS NEEDED:
• StandardScrewdriver
• 1/4-Inch Hex Driver
• 5/16-InchHexDriver
• 7/16-InchWrench
• 7/16-InchDeep
Socket Set
Gas input for direct-vent replace converted to Natural Gas: DVCT40CSP95N
Thedirect-ventgasreplacewhenconvertedtoNaturalGaswillhaveamanifoldpressureofapproximately
3.5inchesw.c.(.871kPa)atthevalveoutletwiththeinletpressuretothevalvefromaminimumof4.5inchesw.c.
(1.120kPa)forthepurposeofinputadjustmenttoamaximumof14.0inchesw.c.(3.484kPa).
FOR USE ON: DVCT40CSP95P CONVERSION KIT PART NUMBER 40637
FORCONVERSIONTO NATURAL GAS
41057-0-0719Page 2
INSTRUCTIONS FOR CONVERSION
1. Ifthereplaceisinstalled,turnOFFgasandelectricsupply
toreplacebeforemakinggasconversion.AllowFireplaceto
cool completely.
2. Removebarrierscreen,glassdoor,logsandembers,and
liners. See Homeowner's Manual.
Figure 1
3. Removemiddleandouterburnersbyremovingscrewson
leftandpullingouttowardsleftside.See Figure 2.
Figure 2
.
4. Remove(2)screwsholdingpilotassemblytoburnerpan.
Thiswillallowpilotassemblytodrop.
5. Remove(4)screwsholdingburnerbaseinplace.
Liftburnerbaseoutofrebox.See Figure 4.
Figure 4
6. Usea7/16inchdeepsocketsettoremoveorices.
See Figure 5.
FRONT
REAR
Figure 5
7. Locatetheoricemarked"37."Usea7/16inchdeepsocket
settoinstalloricemarked"37"ontorearoriceholder.Use
needle-nosepliers,screwmiddletarget40647ontorear
oriceholder.See Figure 6.
8. Locatetheoricemarked"35."Usea7/16inchdeepsocket
settoinstalloricemarked"35"ontofrontoriceholder.Use
needle-noseplierstoscrewfronttarget38042ontoorice
holder. See Figure 6.
FRONT
REAR
Figure 6
41057-0-0719 Page3
9. Loosenrearairshutterscrewandrotatehandletotheleft
untilfullyclosedisachievedandtightendownscrew.
See Figure 7.
10.Repeatwithfrontuntilfullyclosed.
REAR
FRONT
CLOSED
OPEN
MIDDLE AIR
SHUTTER
SCREW
OUTER AIR
SHUTTER
SCREW
Figure 7
11. Usea7/16inchopenwrenchtoloosenpilotbodybyslightly
turningcounterclockwise.Slideoricebrackettootherside
andtightenpilotbodyclockwise.See Figure 8.
“NAT” MARKING
Figure 8
12. Replaceitemsremovedinsteps2-5inreverseorder.
13. Turngasandelectricon.
14. Gas conversion is completed.
Themainburnerameandpilotburneramemustbechecked
forproperamecharacteristics,asoutlinedintheInstallation
InstructionsandOwner'sManual.
Ifreplaceisnotinstalledorprojectregistrationcardhasnot
beenreturnedtoEmpireComfortSystem’s,checkofftypeof
gasconvertedtoonthecard.Alsoindicateconversionbyadding
“Conv.” behind type of gas.
41057-0-0719Page 4
www.empirecomfort.com
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
aboutourproducts,pleasee-mail
If you have a service or repair
question,pleasecontactyourdealer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Hearth Rushmore DVCT40CSP Gas Conversion LP to NAT Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI