Microlife MT 19F1 Navigation Manual

Category
Digital body thermometers
Type
Navigation Manual

Microlife MT 19F1 is an accurate and reliable digital thermometer that offers multiple temperature measuring methods for adults and children. It features a large, easy-to-read LCD display with the last measured value memory recall function. The thermometer's measurement range is from 32.0°C to 42.9°C, with a high precision of ±0.1°C. It provides a quick and gentle measurement within 10-90 seconds, depending on the chosen method. The fever alarm and an audible signal indicate when the measurement is complete.

Microlife MT 19F1 is an accurate and reliable digital thermometer that offers multiple temperature measuring methods for adults and children. It features a large, easy-to-read LCD display with the last measured value memory recall function. The thermometer's measurement range is from 32.0°C to 42.9°C, with a high precision of ±0.1°C. It provides a quick and gentle measurement within 10-90 seconds, depending on the chosen method. The fever alarm and an audible signal indicate when the measurement is complete.

Digital Pen-Type Thermometer
MT 19F1
IMPORTANT SAFETY INSTRUCTIONS
•Thethermometerissuitableexclusivelyfor
measurementofthebodytemperature!
•Theminimummeasurementtimeuntilthesignallingtone
[beep]mustbemaintainedwithoutexception!
•Thethermometercontainssmallparts(battery,etc.)that
canbeswallowedbychildren.Thereforeneverleavethe
thermometerunattendedtochildren.
•Protectthethermometerfromhittingandstriking!
•Avoidbendingthetipmorethan45°!
•Avoidambienttemperaturesabove60°C.NEVERboilthe
thermometer!
•Useonlythecommercialdisinfectantslistedinthesection
«cleaninganddisinfecting»tocleanthethermometer.
Thethermometermustbeintactwhenimmersedinliquid
disinfectant.
•Themanufacturerrecommendstoverifytheaccuracybyan
authorisedlaboratoryevery2years.
Batteriesandelectronicinstrumentsmustbedisposed
ofinaccordancewiththelocallyapplicableregulations,
notwithdomesticwaste.
TURNING ON THE THERMOMETER
Toturnonthethermometer,pushthebuttononthetop;ashort
beepsignals«thermometerON».Adisplaytestisperformed.
Allsegmentsshouldbedisplayed.Thenatanambient
temperatureoflessthan32°C,«-- -»appearsanda«°C»
flashesattheupperrightofthedisplayfield.Thethermometer
isnowreadyforuse.
USING THE THERMOMETER
Choosethepreferredmeasuringmethod.Duringa
measurement,thecurrenttemperatureisdisplayed
continuously.The«°C»symbolflashesduringthisperiodof
time.Ifthesignallingtonesounds(beep-beep-beep-beep10
times)andthe«°C»isnolongerflashing,thismeansthatthe
measuredincreaseintemperatureisnowlessthan0.1°Cin8
secondsandthatthethermometerisreadyforreading.
Toprolongthelifeofthebattery,turnitoffafteruse
bypressingtheoperatingbuttonbriefly.Otherwisethe
thermometerwillautomaticallyturnoffafterabout10minutes.
STORAGE OF MEASURED VALUES
Ifyouholdthebuttondownformorethan3secondswhen
turningthethermometeron,themaximumtemperaturestored
automaticallyatthelastmeasurementwillbedisplayed.At
thesametime,asmall«M»formemorywillappearattheright
ofthedisplay.About2secondsafterreleasethebutton,this
valuewilldisappearandthethermometerwillbeturnedoff.
MEASURING METHODS
In the mouth (oral)
Positionthethermometerinoneofthetwopocketsunder
thetongue,totheleftorrightoftherootofthetongue.The
measuringsensormustbeingoodcontactwiththetissue.
Closeyourmouthandbreatheevenlythroughthenoseto
preventthemeasurementfrombeinginfluencedbyinhaled/
exhaledair.Approx.measuringtime:20seconds
In the anus (rectal)
Thisisthemostreliablemeasuringmethod,andisespecially
suitableforinfantsandsmallchildren.Carefullyinsertthe
measuringsensorofthethermometer2to3cmintotheanal
aperture.Approx.measuringtime:10seconds
In the armpit (axillary)
Toreceivemorereliableresultswerecommendtomeasure
temperatureorallyorrectally.Approx.measuringtime:
20–90seconds!
CLEANING AND DISINFECTING
Name:Isopropylalcohol70%;immerse:max.24hours.
BATTERY REPLACEMENT
Whenthe«»symbol(upside-downtriangle)appearsinthe
lowerrightofthedisplay,thebatteryisexhaustedandneeds
replacing.Forthebatteryreplacementpleaseremovethe
compartmentlidofthethermometer.Replacetheexhausted
batterybypositioningthe+atthetop.Makesureabatteryof
thesametypeisonhand.Batteriescanbepurchasedatany
electricalgoodsshops.Forbatterydisposalpleasereferto
«safetyinstructions».
ThisdevicecomplieswiththerequirementsoftheMedical
DeviceDirective93/42/EEC.Technicalalterationsreserved.
GUARANTEE
Wegrantyoualifetimeguaranteeafterthedateofpurchase.
Anydamagecausedbyimproperhandlingshallnotbe
coveredbytheguarantee.Batteriesandpackagingare
alsoexcludedfromtheguarantee.Allotherdamageclaims
excluded.Aguaranteeclaimmustbesubmittedwiththe
purchasereceipt.Pleasepackyourdefectivethermometer
wellandsendwithsufficientpostageto:
Dateofpurchase:
IMPORTANTES PRECAUTIONS D’EMPLOI
•N’utiliserlethermomètrequepourlamesuredes
températurescorporelles.
•Toujoursrespecterladuréedemesureminimaleen
attendantquelesignalsonoresedéclenche.
•Lethermomètrecontientdepetitespièces(pile,etc.)qui
peuventêtreavaléesparlesenfants.Aussi,nejamaislaisser
lethermomètreauxenfantssanssurveillance.
•Veillerànepasfairetomberlethermomètreetànepasle
cogner.
•Eviterdeplierlasondeàplusde45°!
•Nepasexposerlethermomètreàdestempératures
ambiantessupérieuresà60°C.Nejamaislemettreàbouillir.
•Pourprocéderaunettoyage,n’utiliserquel’undesproduits
répertoriésdansleparagraphe«Nettoyageetdésinfection
duthermomètre».Lethermomètredoitêtreenbonétat,
(absencedefissures),lorsqu’ilestplongédansunliquide
désinfectant.
•Lefabricantrecommandedefairecontrôlerlaprécisiondu
thermomètreparunlaboratoireagréétousles2ans.
Lespilesetinstrumentsélectroniquesdoiventêtre
éliminésenconformitéaveclesprescriptionslocales,
séparémentdesorduresménagères.
MISE EN MARCHE DU THERMOMETRE
Pouractiverlethermomètre,appuyezsurleboutondessus.
Unbrefsignalsonore(bip)indiquequelethermomètreesten
marche.Untestd’affichageestalorsréalisé.Touslessym-
bolesapparaissentàl’écran.Pourunetempératureambiante
inférieureà32°C,«-- -»s’afficheetun«°C»semetàclignoter
danslecoinsupérieurdroitdel’écran.Lethermomètreest
prêtàl’emploi.
UTILISATION DU THERMOMETRE
Choisirlaméthodedemesure.Pendantlamesure,latempéra-
tureencoursestaffichéeenpermanence.Lesymbole
«°C»clignotependantcetemps.Silesignalsonore(10bips
consécutifs)sedéclencheetsilesymbole«°C»neclignote
plus,l’augmentationdelatempératuremesuréeestdésormais
inférieureà0,1°Cen8secondes.
Pourprolongerladuréedeviedelapile,arrêterlethermomètre
immédiatementaprèsutilisationenappuyantbrièvementsur
l’interrupteurmarche/arrêt.Certes,lethermomètres’arrête
automatiquement,maisaprèsenviron10minutesdefonction-
nement.
ENREGISTREMENT DE LA DERNIERE MESURE
Pourobtenirlerappeldeladernièretempératuremesurée,
maintenirlapressionsurl’interrupteurpendantplusde3
secondeslorsdelamiseenmarche.Simultanément,unpetit
symbole«M»demémoires’afficheàdroitedel’écran.Cette
valeurdisparaîtreetlethermomètres’éteindreenvirondeux
secondesaprèsquesonutilisateurarelâchélebouton.
METHODES DE MESURE
Température buccale (dans la bouche)
Placerlethermomètredansl’unedesdeuxcavitéssituées
àgaucheouàdroitedufreindelalangue.L’embout
thermosensibledoitêtreencontactaveclesmuqueuses.Bien
refermerlaboucheetrespirertrèsdoucementparlenezpour
éviterd’affecterlaprisedemesureparl’airaspiré/expiré.
Mesureeffectuéeen20secondesenviron!
Température rectale (dans le rectum)
Ils’agitdelaméthodelaplussûre.Elleconvientplus
particulièrementauxbébésetauxenfants.Introduire
doucementl’emboutd’env.2à3cmdanslerectum.
Mesureeffectuéeen10secondesenviron!
Température axillaire (sous l’aisselle)
Pourobtenirdesrésultatsplusfiables,nousvousrecomman-
donsdemesurerlatempératuredefaçonoraleourectale.
Mesureeffectuéeen20à90secondesenviron!
NETTOYAGE ET DESINFECTION DU THERMOMETRE
Nom:Alcoolisopropyl70%;immersion:max.24heures.
REMPLACEMENT DE LA PILE
Lorsquelesymbole«»(triangleinversé)s’affichedansle
coininférieurdroitdel’écran,lapileestuséeetdoitêtre
changée.Poureffectuersonremplacement,enleverlecou-
vercledulogementdelapileduthermomètre.Remplacer
lapileuséeparunenouvellepiledumêmetypeenveillant
àbienorienterlabornepositive(+)verslehaut.Lespiles
appropriéespeuventêtreachetéescheztoutélectricien.Pour
jeterlespilesusées,sereporteraux«Précautionsd’emploi».
Cetappareilestconformeauxexigencesdeladirective
relativeauxappareilsmédicaux93/42/EEC.
Sousréservedemodificationstechniques.
GARANTIE
Nousvousaccordonsunegarantieàvieàcompterdela
dated’achat.Aucundommageoccasionnéparunemauvaise
manipulationn’estcouvertparlagarantie.Lespileset
l’emballagesontégalementexclusdelagarantie.Toutautre
sinistreexclu.Toujoursjoindrelapreuved’achatàtoute
déclarationdesinistre.Veuillezemballercorrectementvotre
thermomètredéfectueuxetadresserlepaquetaffranchiau
tarifenvigueurà:
Dated’achat:
DESCRIPTION OF THIS PRODUCT
DESCRIPTION DU PRODUIT
Measuringsensor
Emboutthermosensible
DisplayField
Ecrand’affichage
ON/OFFbutton
Interrupteurmarche/arrêt
IB MT 19F1 Var1 1212
Batterycompartmentcover
Couvercledulogementdelapile
CARACTÉRISTIQUES TECHNIQUES
Thermomètreàmaxima
de32,0°Cà42,9°C
«-- -»s’affichepourlestempératuresinférieuresà32,0°C
un«H»s’affichepourlestempératuressupérieuresà42,9°C
±0,1°Centre34°Cet42°C
10°Cet40°C
15à95%d’humiditérelativemaximum
Contrôleinterneautomatiqueàlavaleurtestde37°C.
Pourtoutécartsupérieurà0,1°Clesymbole«ERR»(erreur) s’affiche
Écranàcristauxliquidesavec3chiffresunitéd’affichage
minimale0,1°C
Pourindiquerquelethermomètreestprêtàl’emploiouque
l’augmentationdetempératureestinférieureà0,1°Cen8secondes
Pourenregistrerladernièremesure
–25°Cet+60°C
15à95%d’humiditérelativemaximum
1,5/1,55V;LR41
EN12470-3;ASTME1112;
IEC60601-1;IEC60601-1-2(EMC)
Type / Type:
Measurement range /
Etendue de mesure:
Measurement accuracy /
Précision:
Operating temperature /
Température de
fonctionnement:
Self-test /
Dispositif d’autocontrôle:
Display / Affichage:
Signalling tone /
Signal sonore:
Memory / Mémoire:
Storage temperature /
Température de stockage:
Battery / Pile:
Reference to standards /
Référence aux normes:
TECHNICAL SPECIFICATIONS
Maximumthermometer
32.0°Cto42.9°C
Temp.<32.0°C:display«-- -»forlow(toolow)
Temp.>42.9°C:display«H»forhigh(toohigh)
±0.1°Cbetween34°Cand42°C
10°Cto40°C
15-95%relativemaximumhumidity
Automaticinternalcheckatatestvalueof37°C;
ifthereisadeviationof>0.1°C,«ERR»(error)isdisplayed
Liquidcrystaldisplay(LCD)with3digits;
Smallestunitofdisplay:0.1°C
Forsignallingthatthethermometerisreadytouseandthat
thetemperatureincreaseislessthan0.1°C/8seconds
Forstoringthelastmeasuredvalue
–25°Cto+60°C
15-95%relativemaximumhumidity
1.5/1.55V;LR41
EN12470-3;ASTME1112;
IEC60601-1;IEC60601-1-2(EMC)
Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
EN FR
Read the instructions carefully before using this device.
Veuillez lire attentivement les instructions avant d’utiliser ce produit.
Type BF applied part
Partie appliquée du type BF
  • Page 1 1
  • Page 2 2

Microlife MT 19F1 Navigation Manual

Category
Digital body thermometers
Type
Navigation Manual

Microlife MT 19F1 is an accurate and reliable digital thermometer that offers multiple temperature measuring methods for adults and children. It features a large, easy-to-read LCD display with the last measured value memory recall function. The thermometer's measurement range is from 32.0°C to 42.9°C, with a high precision of ±0.1°C. It provides a quick and gentle measurement within 10-90 seconds, depending on the chosen method. The fever alarm and an audible signal indicate when the measurement is complete.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages