WARNING: To reduce the risk of electrical shock, unplug the dispenser power cord
before repairing or replacing any internal components of the unit. Before any attempt
is made to replace a component, be sure to check all electrical connections for proper
contact.
PROBLEM PROBABLE CAUSE REMEDY
1 a) Dispensing unit unplugged a) Reconnect dispensing unit
Light Display not lit. No b) Defective Bulb b) Replace Bulb.
power. c) Defective Ballast. c) Replace Ballast
d) Loose Bulb in socket. d) Make sure bulb is seated properly in socket.
2 a) Water supply OFF. a) Turn water supply ON.
No water when Rinse b) Clogged inlet screen (Water Inlet b) Disconnect water line and clean inlet screen.
Switch is ON. Valve).
c) Inoperative Water Inlet Valve. c) Check connection, if needed replace Valve.
d) Loose electrical connection. d) Check all electrical connections.
3 a) No product in Hopper. a) Fill hopper with product.
No product is being b) Auger not working. b) Engage Hopper Nut to Motor Gear (see III. E).
Dispensed c) Damaged, loose, or missing Agitator c) Replace Agitator Gear (see III. E).
Gear. d) Check connections of Motor, Relay and/or
d) Inoperative Auger Motor or Relay. Switch, if needed replace such components.
e) Hopper outlet clogged e) Clean Hopper.
f) Faulty Coupling. f) Replace damaged Coupling components.
4 a) Leaking Water Inlet Valve. a) Clean and check fittings of Water Inlet Valve.
Water does not shut off.
Replace Water Inlet Valve if needed.
Water keeps dispensing.
See "Water Inlet Valve Test" on following page
b) Inoperative Rinse Switch b) Check Rinse Switch connections. Replace Rinse Switch if inoperative.
c) Clogged/stuck Water Dispense Valve c) Clean/unclog Water Dispense (Dump) Valve.
Replace Dispense Valve if inoperative.
d) Solid State Product Level Controls d) Replace Solid State Level Controls.
Malfunction
e) Bad dispense relays. e) Replace dispense relays.
5 a) Water Inlet Valve malfunction. a) Check Solenoid. Replace if necessary.
No product is going into
(See "Water Inlet Valve Test" on following pages)
bowls at all. b) Solid State Product Level Controls b) Check The Level Controls
Malfunction Replace if necessary. (See on following pages
"Solid State Product Level Control Test")
c) Hopper not seated correctly. c) Make sure hopper is seated correctly in place.
d) No product in Hopper. d) Fill hopper with product.
e) Bad Dispense relays. e) Replace Dispense relays.
f) Bad powder level sensor. f) Replace powder level sensor.
9