Cecilware PAF2-BL User manual

Type
User manual

This manual is also suitable for

Powder Auto fill Systems
Solid-state level sensors
Out of powder sensors
20-second fill delay Door
safety switch Product
strength control
Model # Description Finish Width Height Ship Wt.
PAF2-SS (2x) 7 Ib. Hoppers Stainless Steel 14.25" 41" 701bs.
PAF2-BL (2x) 7 Ib. Hoppers Black 14.25" 41" 701bs.
PAF3-SS (3x) 7 Ib. Hoppers Stainless Steel 21.5" 41" 105 lbs.
PAF3-BL (3x) 7 Ib. Hoppers Black 21.5" 41" 105 lbs.
OPTIONAL: Rear lit display add "RLD" suffix e.g. PAF2-SS-RLD
Electrical: 120V line cord included, Depth: 16" Height: 41" Plumbing: 1/4"
water line required
43-05 20th Ave. Long Island City, NY 11105
Tel: 800.935.2211 718.932.1414 Fax: 718.932.7860
Visit us on the web: www.cecilware.com
N135A FEB2000
POWDER AUTOFILL
MODEL PAF-2
For Ugolini MT2UL Dispenser
UNPACKING INSTRUCTIONS
Carefully unpack the PAF-2 unit and inspect immediately for shipping damage. Your equipment was
shipped in a carton designed to give it maximum protection in normal handling, and it was thoroughly
inspected before leaving the factory. In case of damage, contact the shipper, not Cecilware.
Water Inlet Connection:
This equipment is to be installed to comply with the applicable Federal, State, or Local Plumbing Codes
having jurisdiction. In addition, a quick disconnect water connection or enough extra coiled tubing (at
least twice the depth of the unit) so that the machine can be moved for cleaning underneath.
The PAF-2 is equipped with a ¼” Flare Water Inlet Fitting which is centrally located under the main
body.
Electrical Connection:
The PAF-2 and the Ugolini Dispenser are to be both plugged into the same, 120 VAC 60 HZ
grounded duplex outlet.
HIGHLY RECOMMENDED:
A water shut-off valve and a water filter, preferably a combination charcoal/phosphate filter, are
recommended to remove odors and inhibit lime and scale build up.
PAF-2 FEATURES:
The PAF-2 Powder Autofill is equipped with:
1. Solid-State Level Controls, replenish the product in the Ugolini bowls after each serving.
2. "Out of powder" Sensors, located behind the hoppers, stops the machine from dispensing water
only, thus safeguarding the machine from icing up. When the powder level inside the hopper drops
below the sensor, the dispenser will stop and the green indicator light will go OFF.
3. 20-Second Fill Delays, prevent false or premature fill starts due to product movement in bowls.
4. Door Safety Switch, stops the Auto Fill System when door is opened. To check operation with
door open, depress switch button and hold for 20 seconds before filling occurs.
5. Speed Controls, adjust auger output for product strength.
SET-UP INSTRUCTIONS:
After all parts have been unpacked and placed on a counter:
1. Remove the (2) panel screws from the left side, and the (2) regular screws from the right side of
the Ugolini dispenser.
2. Attach the support frame to the dispenser and secure in place by replacing the (2) thumbscrews
and the (2) regular screws in their original location.
1
3. Place the PAF-2 on top of the support frame, and secure with the two large knob screws
supplied.
2
4. Attach the two probes onto the back of the bowls.
5. Replace the left and right side bowl covers making sure the holes line up with plastic nozzles
(holes are located towards inside).
6. Attach water connection (1/4" flare fitting)
7. Plug both the PAF-2 and the Ugolini unit into the same, 120VAC 60 HZ grounded duplex outlet,
8. To test unit, turn on the power switch, located inside and activate (push up and hold) rinse
switches. Water should flow and whipper motor should run.
3
FILLING THE HOPPERS:
Remove hoppers, fill with product, and replace. Hoppers hold 4 to 6 IDS depending on product density
NOTE: Hoppers are equipped with product chutes, which have sliding, no spill, closures
These are designed to prevent spillage when filling and removing hoppers.
PRODUCT STRENGTH ADJUSTMENT:
Water flow rate is factory set at 0.75 oz per second.
Product throw is factory set on speed dial to No. 6 (4-5 grams / sec).
These settings are the equivalent of 1.5 Ibs. (681 grams) of product per 1 gallon of water. The
dispense duration for this volume will be approximately 2.8 minutes.
FILLING BOWLS AUTOMATICALLY:
1. Position full hopper into the machine compartment, making sure the auger drives are fully
engaged.
2. Position product chutes to point down into the mixing chambers.
3. Push in the no-spill closures on the product chutes.
4. Activate power switch.
5. With door open push in the door safety switch and hold for 20 seconds. The auto fill system will
start filling.
6. Release the door safety switch and close door, allow auto fill system to complete filling.
7. Activate the controls on the Ugolini MT2UL to begin cooling.
NOTE: After the bowls are filled, remove and refill hoppers
4
SANITIZING:
All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first.
To prepare a sanitizing solution:
ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT
ROOM TEMPERATURE (70° - 90°F).
Soak all parts for a minimum of 3 min. in the sanitizing solution.
Note: Always start with an unopened bottle of Clorox Bleach, since the solution from an opened bottle
has a short life span.
Let all sanitized parts drain and dry naturally, DO NOT WIPE THEM DRY. Before using the
sanitized unit (or parts) with foodstuffs, rinse all parts thoroughly with water.
CARE FOR STAINLESS STEEL:
Stainless Steel surfaces that come in contact with food substances, MUST BE CLEANED EVERY DAY.
WHEN CLEANING STAINLESS STEEL, ONLY A "pH" NEUTRAL CLEANER IS TO BE USED. Use nylon
or brass brushes (not steel wire brushes) for removing food deposit. Many food products contain acids,
alkalis, or other substances, which corrode Stainless Steel.
CLEANING THE HOPPERS:
Open the cabinet door.
Take the hopper out of the cabinet.
Pull off the product chute and remove the hopper cover.
Unscrew the auger gear (clockwise) while holding steady the auger inside the hopper.
Take out the auger and agitator.
Rinse each item thoroughly.
Let dry all items and reassemble.
5
POWDER AUTOFILL
MODEL PAF-2
(FRONT VIEW)
1. HOPPERS LEFT [CD284] AND RIGHT [CD299]
CAPACITY 7LBS EACH
2. POWER ON-OFF SWITCH [L299A]
3. RINSE SWITCH LEFT AND RIGHT [L642A]
4. MIXING CHAMBER WITH MIXING BLADE [CD63A]
5. SPEED CONTROL POTENTIOMETER LEFT AND RIGHT [L557A]
6
POWDER AUTOFILL
MODEL PAF-2
(REAR VIEW)
6. CABINET HOUSING
7. AUGER MOTOR 24 V.DC LEFT AND RIGHT [CD290]
8. RELAY (2) PRODUCT AND WHIPPER MOTORS [B129A]
9. RELAY (1) DOOR SAFETY [B129A]
10. SPEED CONTROLS 28 V. DC (2) [L556A]
11. LIQUID LEVEL CONTROLS (2) [L647A]
12. CAPACITIVE EFECTOR SENSORS (2) AC/DC 30 TO 270V [L641A]
13. TRANSFORMER (2) 24V. AC LEFT AND RIGHT [CF29A]
14. WHIPPER MOTOR LEFT AND RIGHT [CD75A]
15. DUAL VALVE, WATER INLET [CD283]
7
POWDER AUTO FILL
HOPPER ASSEMBLY
AND RELATED PARTS
TROUBLESHOOTING GUIDE
8
WARNING: To reduce the risk of electrical shock, unplug the dispenser power cord
before repairing or replacing any internal components of the unit. Before any attempt
is made to replace a component, be sure to check all electrical connections for proper
contact.
PROBLEM PROBABLE CAUSE REMEDY
1 a) Dispensing unit unplugged a) Reconnect dispensing unit
Light Display not lit. No b) Defective Bulb b) Replace Bulb.
power. c) Defective Ballast. c) Replace Ballast
d) Loose Bulb in socket. d) Make sure bulb is seated properly in socket.
2 a) Water supply OFF. a) Turn water supply ON.
No water when Rinse b) Clogged inlet screen (Water Inlet b) Disconnect water line and clean inlet screen.
Switch is ON. Valve).
c) Inoperative Water Inlet Valve. c) Check connection, if needed replace Valve.
d) Loose electrical connection. d) Check all electrical connections.
3 a) No product in Hopper. a) Fill hopper with product.
No product is being b) Auger not working. b) Engage Hopper Nut to Motor Gear (see III. E).
Dispensed c) Damaged, loose, or missing Agitator c) Replace Agitator Gear (see III. E).
Gear. d) Check connections of Motor, Relay and/or
d) Inoperative Auger Motor or Relay. Switch, if needed replace such components.
e) Hopper outlet clogged e) Clean Hopper.
f) Faulty Coupling. f) Replace damaged Coupling components.
4 a) Leaking Water Inlet Valve. a) Clean and check fittings of Water Inlet Valve.
Water does not shut off.
Replace Water Inlet Valve if needed.
Water keeps dispensing.
See "Water Inlet Valve Test" on following page
b) Inoperative Rinse Switch b) Check Rinse Switch connections. Replace Rinse Switch if inoperative.
c) Clogged/stuck Water Dispense Valve c) Clean/unclog Water Dispense (Dump) Valve.
Replace Dispense Valve if inoperative.
d) Solid State Product Level Controls d) Replace Solid State Level Controls.
Malfunction
e) Bad dispense relays. e) Replace dispense relays.
5 a) Water Inlet Valve malfunction. a) Check Solenoid. Replace if necessary.
No product is going into
(See "Water Inlet Valve Test" on following pages)
bowls at all. b) Solid State Product Level Controls b) Check The Level Controls
Malfunction Replace if necessary. (See on following pages
"Solid State Product Level Control Test")
c) Hopper not seated correctly. c) Make sure hopper is seated correctly in place.
d) No product in Hopper. d) Fill hopper with product.
e) Bad Dispense relays. e) Replace Dispense relays.
f) Bad powder level sensor. f) Replace powder level sensor.
9
PROBLEM PROBABLE CAUSE REMEDY
6 a) Leaking Water Dispense Valve a) Replace Water Dispense Valve
Water drips from b) Mixing Chamber clogged. b) Clean Mixing Chamber.
mixing chamber
7
a) Product throw too high
a) Adjust product throw rate. (See "Prod
uct Strength
Product too strong. Adjustments" Volume & Gram Throw)
8 a) Product throw too low a) Adjust product throw rate (see" Product Strength
Product too weak.
Adjustments")
9 a) Whipper Blade missing. a) Replace Whipper Blade
Product not whipped. b) Loose electrical connection to motor. b) Check electrical connections to motor.
c) Whipper Motor defective. c) Replace Whipper Motor.
10 a) Whipper blade not properly aligned or is missing. a) Check blade alignment, if needed replace blade and mixing
Noise coming from
Chamber.
mixing chamber
11 a) Hopper not properly engaged in back, or a) Check the mating between the auger motor's
Grinding noise coming Hopper not seated properly Gear and hopper's coupling/nut. Check also pin in base.
from unit
Pin must be dropped into hole in base.
10
11
POWDER AUTO FILL
INSTRUCTIONS 4" ADAPTER
When mounting 4 inch legs, attach the bottom plate
#SD65A to the Ugolini Dispenser as shown
NI42A
CECILWARE CORPORATION 43-05 20 AVE. L.I.C. NY 11105
DISPENSER
BOTTOM PLATE
#SD65A
4 INCH LEGS (4)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Cecilware PAF2-BL User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI