  • Hello! I am an AI chatbot trained to assist you with the Omega FT-50 Series Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!

SPECIFICATIONS StepOne
AboutThisManual:PLEASEREADTHEENTIREMANUALPRIORTOINSTALLINGORUSINGTHISPRODUCT.
Dimensions:
SideView: TopView:
Components:Checktomakesurethatallthepartsareincludedinthekitbeforeproceeding.Oneflowswitch
fitting(FT50series)includesthefollowingparts:
1FlowSwitchFitting
FT51‐PolypropyleneFitting
FT52‐PolyvinylideneFluorideFitting
1Oringforsensor
Specifications:
Housingmaterials: FT51:Polypropylene
FT52:PolyvinylideneFluoride
Insertionport: Locatedonbottom
Temperaturerating: F:32to194°
C:0to90°
Pressurerating: 150psi@25°C,derated@1.644psiper°Cabove25°C
Connections: 3/8”NPT,Female
Compatibility:TheFT50seriesflowswitchfittingiscompatiblewiththefollowingseriesofflowswitches
fromOmegaEngineering:
FST210R
FST211SPST
FST212R
FST212SPST
INSTALLATION StepTwo
MakeaFailSafeSystem:Designafailsafesystemthataccommodatesthepossibilityofsensororpower
failure.Incriticalapplications,Flowlinerecommendstheuseofredundantbackupsystemsandalarmsin
additiontotheprimarysystem.
AbouttheFlowSwitchFitting:OmegaEngineering’sFlowSwitchFittingisdesignedforusewiththeOmega
EngineeringThermal Dispersionliquidflow switch (FST200 series).Averyeconomical and accurate method
ofsensingflowiscreatedwhenusingtheFT50serieswiththeFST200seriesflowswitch.Liquidsfrom0.4to
1.2 SG and a 1 to 300 cp
can be monitored.Also,pulsating flows from 10 to 100 pulses per minute can be
monitored.The3/8”NPTfemaleinletsallowforeasyconnectionstolinesizesfrom1/8”to½”.

FT50 series unique design creases
a vortex inside its chamber.The
vortex uses its stored energy to
create a flow pattern.This design
isideal forpulsatingflowsandlow
flowconditions.
InserttheFT50intothe¾”NPTsensorporttakingcaretoorientatethe
twotemperatureprobesperpendiculartotheflowofthevortex.
Note:Besuretoremove/bleedallairfromtheinsideofthechamberfor
operationoftheflowswitch.
Note:Theflowswitchfittingcanbemountedinanyorientation.
User’sResponsibilityforSafety:FLOWLINEmanufacturesseveralmodelsofflowswitchesandliquidlevel
sensors, controller and mounting systems.It is the user’s responsibility to select components that are
appropriatefor the application, install it properly, performtests of the installed system, andmaintain all
components.Thefailuretodo
socouldresultinpropertydamageorseriousinjury.
Proper Installation and Handling:Use a proper sealant with all installations.Never over tighten the
sensor within the fitting beyond a maximum of 80 inchpounds torque.Always check for leaks prior to
systemstartup.
MaterialCompatibility:Theflowswitchfittingisavailableintwodifferentwettedmaterials.ModelFT51
ismadeofPP(polypropylene,apolyolefin).ModelFT52ismadeofPVDF(PolyvinylideneFluoride).Make
surethattheapplicationliquidsarecompatiblewiththematerialsthatwillbewetted.
FlammableorExplosiveApplications:TheFT50seriesfittingmaybeusedwithinflammableorexplosive
applications. In hazardous applications, use redundant measurement and control points, each having a
differentsensingtechnology.
/