Panasonic VLMW250BX Operating instructions

Category
Door intercom systems
Type
Operating instructions

This manual is also suitable for

Installation Guide
LPlease read this Installation Guide before installing the unit and save for future reference.
LPlease read this Installation Guide carefully, and install the unit safely and correctly by
following the instructions. Panasonic assumes no responsibility for injuries or property
damage resulting from failures arising out of improper installation or operation inconsistent
with both the Installation Guide and Operating Instructions.
LPlease con rm the wiring schematic diagram in this Installation Guide when you increase
an optional equipment
.
For door station and main monitor station
For your safety
To prevent severe injury and loss of life/property, read this section carefully before using the
unit to ensure proper and safe operation of your unit.
WARNING
LTo reduce the risk of electric shock, do not disassemble this unit. Refer servicing to an
authorized service center when service is required. Opening or removing covers may
expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric
shock when the unit is subsequently used.
LDo not make any wiring connections when the power supply is turned on.
LNever install wiring during a lightning storm.
LDo not overload power outlets and extension cords. This can result in the risk of re or
electric shock.
LDo not install the main monitor station in the following places:
– Places where the main monitor station may be splashed with water or chemicals.
– Places where there is a high concentration of dust, or high humidity.
LWhen existing chime wires are used, it is possible that they contain AC voltage. Electric
shock or unit damage could result. Contact an authorized service center.
CAUTION
LThe power cord is used as the main disconnect device. Ensure that the power outlet is
installed near the product and is easily accessible.
LInstall the unit securely adhering to the instructions in this guide to prevent it from falling off
the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC (autoclaved
lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls.
Do not install the unit using a different method from the instructions in this guide.
LIf the wiring is outdoors, use a protection tube or a surge protector.
LIf the wiring is underground, do not make any connections underground.
LIf the wiring is underground, use a protection tube.
Model
Name
Wireless Video
Intercom System
Main Monitor
Model No.
VL-SW250BX VL-MW250BX
VL-V566BX VL-MW250BX
Included accessories for installation
LMounting bracket ............1
L Attached to the rear of the main
monitor station.
LWood screws ..................2
(4 mm × 16 mm)
LWood screws ..................2
(3.8 mm × 20 mm)
L Attached to the bag the door station
is in.
For the door station
For the main monitor station
1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan
© Panasonic System Networks Co., Ltd. 2010
PNQW2395ZA SV0910SN0
VL-V566BX is described as “Door
station” and VL-MW250BX is described
as “Main monitor station” in this guide.
Before installation
To avoid malfunction or communication disturbances, do not install either the door station or the
main monitor station in the following locations:
– Places where vibration or any other kind of impact occurs.
– Places where echoing is frequent.
Places near a high concentration of dust, hydrogen sul de, ammonia, sulfur, or noxious fumes.
Within 2 m of a TV, microwave, personal computer, air conditioner or any other electrical device.
Installation position of the door station and camera range
N Views when the camera is facing forwards at 0° (default).
LExample: Installation height is 1450 mm (standard position).
Side view Top view
Image range:
960 mm
500 mm
87°
1450 mm
1810 mm
Center of
the door
station
66°
650 mm
Image
range
1160 mm
500 mm
The camera angle can be adjusted using the camera angle control lever on the rear of the door
station (step 3, “Installing the door station”), so that the image range can be changed.
Center of
the door
station
1690 mm
1100 mm
66°
710 mm
500 mm
980 mm
Image
range
Image range:
1080 mm
810 mm
500 mm
87°
270 mm
N Side view when the camera is installed
lower than the standard position, and
facing upwards at 1.
LExample: Installation height is 1100 mm.
N Top view when the camera is facing
left or right at 15° *
1
.
LExample: Camera angle faces left 1.
*
1
If the camera points 15° upwards, the left or right angle is less than 7°.
Note:
LThe measurements and angles are for reference purposes and may vary depending on the
environment.
LIf a strong light is shining on the door station, the visitor’s face may not be distinguishable.
Do not place the door station in the following locations.
– Where most of the background is the sky.
– Where the background is a white wall, and direct sunlight will re ect off it.
– Where direct sunlight will shine on the door station.
LDo not place the door station in the locations where echoing occurs, causing the unit to beep
frequently.
L Make sure the rear of the door station is not subject to water.
Standard installation position of the main monitor station
Place the main monitor station in a location that your eyes are the same height as the center of the
display.
If a position of installation for the main monitor station is speci ed
Install the mounting bracket to one of the following positions.
82.5 mm
49 mm
51.9 mm
Position of installation for the main monitor station
Note:
LThis unit is using an electric wave frequency of 2.4 GHz. Read “For best performance” in the
Operating Instructions.
LIn areas surrounded by a high electrical eld, disturbances may occur in the main monitor
station’s image or sound.
LBe sure to install the main monitor station more than 5 m away from the door station.
LDo not place any objects within 20 cm of the main monitor station. This may cause
communication errors or malfunction.
LDo not install the main monitor station inside a wall.
LDo not install the main monitor station in places where it will be affected by extremely high-
frequency radio waves (near broadcasting antennas etc.). This may cause the display to icker
or an interrupting noise to occur.
If you change to the main monitor station from chime, bell or buzzer
Existing wires (e.g. chime, bell or buzzer) may connect to power supplies (AC 100
240 V or 24 V).
If you connect the main monitor station through such existing wires, electric shock or unit damage
may occur. Contact the dealer where you purchased.
Installing the door station
Important:
LOn the bottom surface of the door station, there are holes to allow water to drain.
Do not cover them up when installing.
1 Remove the mounting base.
A Open the screw
cover.
TScrewdriver
Mounting base
B Loosen the
mounting screw.
Water drain
holes
2 Attach the mounting base to the wall securely using the wood screws (3.8 mm x 20 mm).
LInstall the mounting base on a vertical at wall.
LBefore drilling, refer to “Before installation” for installation location.
83.5 mm
Wall
Wire (Not included)
Mounting base
Wood screws
3 Adjust the camera angle using the camera angle control lever.
LThe angle can also be adjusted to the left
or upper left.
<Examples of camera angle>
<Facing forwards> <Facing upwards> <Facing right> <Facing upper right>
Rear view
Camera angle
control lever
Left
(maximum 15°)
Right
(maximum 15°)
Upwards
(maximum 15°)
Important:
LWhen the camera angle is adjusted to the upper left or upper right, the image may be slightly
distorted.
4 Connect the wire, then mount the door station to the mounting base.
C Fasten the screw, then
close the screw cover.
A Unscrew the screws.
Push in the wire to the terminal connectors
(non polar), then tightly fasten the screws.
Wire (connecting to the main monitor station)
B Mount the door station to
the mounting base.
Installing the main monitor station
1 Attach the mounting bracket to the wall securely using the wood screws (4 mm x 16 mm).
LInstall the mounting bracket on a vertical at wall.
LBefore drilling, refer to “Before installation” for installation location.
83.5 mm
Wood screws
Wall
Wire (Not included)
Mounting bracket
2 Attach the wires connected to the door station to the terminal connector.
LConnect the wire correctly according to “Wiring schematic diagram”.
LWhile pressing on the button with a pointed object such as a screwdriver, insert the wire into
the terminal connector. (To disconnect a wire, press on the button while pulling out.)
Wire from the door station
Stripped end of
the wire
9 mm
Terminal
connector
Button
3 Mount the main monitor station to the mounting bracket.
A Fit into position as shown in the gure.
B Push the main monitor station down until it is secure.
B
A
4 Connect the plug into an AC outlet (100 – 240 V AC).
Important:
LConnect the plug to the power outlet which is easily accessible.
To use an existing wire in your home
1 Be sure to turn off the power and con rm that the wire type is CAT-3 (ø0.5) or 22 AWG
(ø0.65). If the wire type is not CAT-3 (ø0.5) or 22 AWG (ø0.65), change the wire to either of the
speci ed wire types.
2 Install the main monitor station and the door station.
3 Turn on the power.
Wiring schematic diagram
Set up correctly according to the following wiring schematic diagrams and “Wire type and
distance”.
Door (Door Opener) 2 *
4
Door (Door Opener) 1 *
4
PBX*
3
Door station 2Door station 1 *
1
(Non polar) (Non polar)
Main monitor station
Terminal box
(4-conductor wiring)
(Non polar)
(Non polar)
(Non polar)
Power plug
(100
240 V AC)
You can also connect
an optional lobby
station for apartment
complexes.*
2
Optional equipment
(Refer to pages 42-43 in the Operating Instructions.)
*
1
For VL-MW250BX users: The door station is optional (not included).
*
2
Connecting an optional lobby station for apartment complexes
Be sure to perform the following to ensure proper operation:
LConnect to terminal D1/D2 on the main monitor station.
LAfter connecting to the main monitor station, change the setting of “LOBBY
CONNECTION” to “YES” using the main monitor station. (Refer to page 38 in the
Operating Instructions.)
*
3
For information about compatible PBXs, refer to page 4 in the Operating Instructions.
*
4
Connecting a door opener
LBefore connecting to a door opener, make sure that:
– S1/S2/S3/S4 terminal: Normally open/Actively short
– The door opener is less than 30 V AC (1 A), 24 V DC (1 A).
S1/S2/S3/S4 terminal on the main monitor station is not the power supply to the door
opener. If the door opener needs a power supply device to connect to the main monitor
station, contact the dealer where you purchased the door opener.
L The door opener for the door station connected to terminal D1/D2 must be
connected to terminal S1/S2. The other door opener for the door station connected
to terminal D3/D4 must be connected to terminal S3/S4.
L You can connect up to 2 door openers to the main monitor station. If the main monitor
station is connected to a PBX, one of the 2 door openers can be connected to the PBX
and operated from the PBX extensions.
Note:
LWhen you move the main monitor station, make sure the PBX is disconnected.
LThe door opener wiring schematic diagram is only an example. Refer to the wiring
instructions provided with your door opener and PBX for details.
Wire type and distance
LWire (between the main monitor station and the door station):
Type Distance Loop resistance
General cable CAT-3 Maximum 50 m
10 Ω or lower
General cable 22 AWG (ø 0.65) Maximum 100 m
LWire (between the main monitor station and PBX):
Type: General cable CAT-3 or 22 AWG (ø 0.65)
Distance: Maximum 100 m
  • Page 1 1

Panasonic VLMW250BX Operating instructions

Category
Door intercom systems
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI