Foster FSL400G (11-104) Owner's manual

Category
Alarm clocks
Type
Owner's manual

This manual is also suitable for

Foster FSL400G (11-104) is a refrigerator with a gross capacity of 380 liters. It has a settable temperature range of +1°C to +4°C, making it suitable for storing a variety of refrigerated products. The Foster FSL400G is designed to be energy-efficient, with an energy consumption of 2.1 kWh/24h. It is also designed to be easy to clean, with a stainless steel exterior and interior. Additionally, the Foster FSL400G is designed to be durable, with a robust construction and a long lifespan.

Foster FSL400G (11-104) is a refrigerator with a gross capacity of 380 liters. It has a settable temperature range of +1°C to +4°C, making it suitable for storing a variety of refrigerated products. The Foster FSL400G is designed to be energy-efficient, with an energy consumption of 2.1 kWh/24h. It is also designed to be easy to clean, with a stainless steel exterior and interior. Additionally, the Foster FSL400G is designed to be durable, with a robust construction and a long lifespan.

cabinet installation
and operating instructions
slimline range
GB
Operating instructions
F
Notice d'installation
et d'utilisation
D
Bedienungsanleitung
operating instructions
Foster European Operations
Foster Refrigerator
Oldmedow Road, King’s Lynn,
Norfolk, PE30 4JU
England
Tel: 01553 691122
Fax: 01553 691447
Website: www.fosterrefrigerator.co.uk
Email: sales@foster-uk.com
a Division of ITW (UK) Ltd.
France
Foster Refrigerator France SA
Tel: (33) 01 34 30 22 22 Fax: (33) 01 30 37 68 74 Email: [email protected]
Germany
Foster Refrigerator Germany
Tel: (0781) 96 93 00 Fax: (0781) 96 93 019 Email: info@fosterrefrigerator.de
SLIMLINE0405 00-555734
NL
Gebruiksaanwijzing
To adjust the position of the
shelves insert the shelf clip
into the vertical support with
the ‘hook’ pointing upwards
and ‘slot downwards’ into
position. Ensure the shelves
are parallel and level after
fitting.
Shelf/Tray Supports
3
installation
Positioning/unpacking
1
All models are normally fitted
with swivel castors. Ensure
during installation the unit is level
if not the door(s) may not close
correctly. Adjust castors by
inserting spacers under the
appropriate castor and the base
of the unit until level.
Castors/legs/feet
2
IMPORTANT:
To the installer: Installation of these units should be carried out by a competent person and
the appropriate codes of practice adhered to, thus ensuring safe installation.
Pass to the user: Do not discard this document: it contains important guidelines on
Operation, Loading, Cleaning and Maintenance and should be kept for reference.
english
GB
2
Important : It is not advisable to position the cabinet adjacent to an intense heat source i.e. flame grill, oven,
hob, etc. as this may have an adverse effect on the machine and performance.
Unpacking: The unit is delivered on a pallet and shrink-wrapped. Documentation is inserted into a clear
pocket located inside the unit. Carefully remove the protective plastic film and cardboard from the
unit exterior and from the door opening surround making sure that any sharp instrument used does not cause
damage, plus remove any quality labels.
Cabinet removal from the pallet: Cut the plastic ties securing the cabinet to the pallet using a sharp knife
or scissors. Move the unit over the front of the pallet, carefully slide the unit off the pallet until it is stable on
the ground.
Cabinet
castors
DISPOSAL REQUIREMENTS
If not disposed of properly all refrigerators have components that can be
harmful to the environment. All old refrigerators must be disposed of by
appropriately registered and licensed waste contractors, and in accordance
with National laws and regulations.
english
GB
3
If the unit has been laid on its back at any time DO NOT switch on immediately but leave in the upright
position for at least 60 minutes. To switch on the unit see ‘User Operation Guidelines’. Allow the unit to reach its
normal operating temperature before loading with product.
Switching On
4
start up
user operation guidelines
5
Controller
-
Initial Start Up
Your new Foster Cabinet will be delivered ready to run. Plug into the mains supply and the
unit will operate in the following way.
Start Up & Self Test: The indication is only displayed during the first three seconds
following the mains electrical power being applied to the unit. During this period the
controller performs a self-check.
Once the self-check has been completed will be displayed.
6
Operator Instructions
1. To Start the Unit
Press and hold for three seconds. The unit will start and the air temperature will be displayed.
2. To Check Storage Temperature Set Point
Check set point by pressing the button
Factory Temperature Set Point
Refrigerator +1˚C to +4˚C
Freezer -18˚C to -21˚C.
Exit from set up occurs after 10 seconds if no button is pressed.
3. Manual Defrost
To initiate a manual defrost press and hold will be displayed release.
On completion of the defrost will be displayed until the cabinet temperature is achieved and then it will revert to
displaying the normal cabinet temperature.
4. Set Unit to Standby.
Press display shows (standby indication)
Standby Indication
This indication is displayed while the unit is not operating but with mains power applied to the unit. This mode may be used for inter-
nal cleaning regimes and short periods when the unit is not required.
For extended periods of inactivity the mains supply should be isolated.
OFF
OFF
i set
i set
EF
e
e
P
F
english
GB
5
english
GB
4
7
Alarms and Warnings
High temperature alarm
Will be displayed.
The alarm will sound but can be silenced by pressing any of the buttons, however it will return after the pre-set
designated period. If the unit returns to normal operating temperature the alarm etc. will be cancelled automatically.
If this does not occur after 4 hours call your Foster Authorised Service Company.
Low temperature alarm.
Will be displayed.
The alarm will sound but can be silenced by pressing any of the buttons and the unit will continue to operate,
however it will return after the pre-set designated period. If the unit returns to normal operating temperature the
alarm etc. will be cancelled automatically. If this does not occur after 4 hours call your Foster Authorised Service
Company.
Air Temperature Probe Failure.
Will be displayed.
The alarm will sound but can be silenced by pressing any button.
There is no further action that can be taken by the user in this instance; therefore call your Foster Authorised Service
Company as soon as possible. During this period the unit will continue to operate but have a reduced performance.
Evaporator Temperature Probe Failure. (Freezer Cabinets Only)
Will be displayed.
The alarm will sound but can be silenced by pressing any button.
There is no further action that can be taken by the user in this instance; therefore call your Foster Authorised Service
Company as soon as possible. During this period the unit will continue to operate satisfactorily, but this failure will
have an effect on the defrost and therefore efficiency if allowed to continue.
LO
E1
E2
These should be inspected on a regular basis and replaced if damaged. To clean, wipe with a warm damp
soapy cloth followed by a clean damp cloth and finally thoroughly dry before closing the door.
Door Gaskets
9
cleaning/maintenance
Important Cleaning Instructions
Cared for correctly, the cabinet has the ability to resist corrosion and pitting for many years.
The following weekly cleaning regime is recommended.
a. Exterior and Interior: Wash with mild soapy water, rinse with clean water and dry thoroughly.
b. Door and bottom unit cover: Use a proprietary stainless steel cleaner following the
manufacturers instruction.
WARNING:
High alkaline cleaning agent or those containing bleaches, acids and chlorines are very harmful to
all materials. Corrosion and pitting may result from their accidental or deliberate application.
If any of these liquids should come into contact with the unit during general kitchen cleaning,
wipe down the affected area immediately with clean water and rub dry.
Never use wire wool or scouring powders on surfaces.
After cleaning allow the unit to reach its normal operating temperature before reloading with
product. During usage all spills should be wiped clean immediately but care should be taken not
to touch the interior of freezer units as warm skin can ‘freeze’ to metal cabinets.
Cleaning Instructions
8
N.B. Before internal cleaning, switch off unit.
Important: Disconnect the mains electrical supply to the machine prior to removing the condenser
compartment unit cover.
Remove the two screws located at the base of the condenser compartment unit cover and pull forward
taking care not to damage the interconnecting cables to the controller. Clean the condenser using a soft
brush or vacuum cleaner.
NOTE: if there are any stubborn grease deposits etc left on or through the condenser call your Foster
Authorised Service Company to carry out a full service.
Failure to carry out this action may invalidate the warranty of the condensing unit.
Condenser
10
operational failure
Checks must be carried out by a competent person.
Before calling a Foster Authorised Service Company check the following:
a) Power failure (may be off at source)
b) Fault conditions as described in User Operational Guidelines - Alarms and Warnings.
c) Damaged mains lead plug.
When requesting service assistance always quote the following:
a) unit serial number (E..........)
b) the model number from the serial number plate located inside the unit.
c) If a “Fault Code ” appears quote the “Fault Code Reference” to the Foster Authorised Service Company.
Problem Diagnosis
15
Cover all foods and
separate raw and cooked
foods.
Food
13
When loaded, ensure
that air can circulate
around / through
stored products.
Airflow
Evenly distribute the
load.
For Cabinets 40kg max
per shelf or 120kg per
full door section.
Do not stack product on
the base of the unit.
Load Distribution
11
12
40Kg
Cool hot food before
loading.
Cool Hot Food
14
loading
HI
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Foster FSL400G (11-104) Owner's manual

Category
Alarm clocks
Type
Owner's manual
This manual is also suitable for

Foster FSL400G (11-104) is a refrigerator with a gross capacity of 380 liters. It has a settable temperature range of +1°C to +4°C, making it suitable for storing a variety of refrigerated products. The Foster FSL400G is designed to be energy-efficient, with an energy consumption of 2.1 kWh/24h. It is also designed to be easy to clean, with a stainless steel exterior and interior. Additionally, the Foster FSL400G is designed to be durable, with a robust construction and a long lifespan.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI