VITRA Comma Assembly Instructions

Type
Assembly Instructions
2023, 62913788/B
Comma
Developed by Vitra in Switzerland
Design: Vitra
Electrification
2/20 2023, 62913788/B
EN
CONTENTS
Contents
1 Notes............................................................................................................................................... 3
1.1 Proper use ...................................................................................................................................... 3
1.2 Explanation of symbols ............................................................................................................... 3
1.3 Disposal .......................................................................................................................................... 3
2 Safety .............................................................................................................................................. 4
3 Product description ...................................................................................................................... 5
4 Concept for electrification .......................................................................................................... 6
4.1 Series connection ......................................................................................................................... 6
4.2 Parallel connection ...................................................................................................................... 7
4.3 Series connection mixed with parallel connection ................................................................ 8
5 Mounting principle and instructions ......................................................................................... 9
5.1 Example wiring .............................................................................................................................. 9
5.2 Specifications for the wiring ...................................................................................................... 10
5.2.1 Marking of separate circuits...................................................................................................... 12
6 Assembly ....................................................................................................................................... 13
6.1 Installation of multiple outlet strip and Swiss distribution black box................................. 13
6.2 Fitting the distributor .................................................................................................................. 14
6.3 Fitting the cable fasteners ........................................................................................................ 14
6.4 Installation position of multiple outlet strip Desk 2 ............................................................... 15
6.5 Fitting strain relief ....................................................................................................................... 16
6.6 Fitting GST-18 protective cap ....................................................................................................17
7 Checklist ........................................................................................................................................ 18
8 Notes............................................................................................................................................. 19
2023, 62913788/B 3/20
NOTES
EN
1 Notes
Please read these instructions carefully before use. Keep them in a safe place for later refer-
ence. Assembly/dismantling may only be performed by qualified personnel. Check delivery
is complete before assembly.
1.1 Proper use
All components listed in this manual are designed exclusively for the electrification of your
furniture.
There is a danger of damage to property or personal injury if improperly used.
Please dispose of your product in accordance with the currently applicable regula-
tions in your country.
1.2 Explanation of symbols
Safety instructions are indicated in these instructions as follows.
DANGER
Indicates a hazardous situation.
Failure to avoid such a situation may lead to severe or even fatal injury.
NOTE
Indicates basic information and work recommendations.
NOTE
Indicates a reference to another instruction.
1.3 Disposal
NOTE
WEEE symbol: (Waste Electrical and Electronic Equipment) Waste Elec-
trical and Electronic Equipment Directive 2012/19/EU. Do not dispose of
your electrical or electronic equipment in the household waste. Please
dispose of your product in accordance with the currently applicable reg-
ulations in your country.
4/20 2023, 62913788/B
EN
SAFETY
2 Safety
NOTICE
Please adhere to the following points to avoid any exposure to danger:
The live components are only de-energised when the power plug is disconnected or
the power supply is switched off via an appropriate circuit breaker.
If a live component is damaged, it must be replaced by Vitra Service or by a qualified
specialist.
All work on and with electrical components may only be carried out by qualified spe-
cialists.
The live components are only designed for indoor use.
The electrical system of the furniture must be connected to an electrical supply with a
protective conductor (grounding).
The electrical system of the furniture must be protected by a residual current device
(RCD) with a rated differential current not greater than 30 mA.
DANGER
Unsecured electrical power!
Risk of fatal injury from electric shock
Disconnect the power supply before carrying out assembly and maintenance work.
Disconnect the power supply in the event of thunderstorms and before lengthy ab-
sences.
Disconnect the power supply if the unit begins to emit smoke, odours or unusual
noises.
The power supply must be easily accessible.
The maximum grid capacities specific to each country must not be exceeded.
Check all live components for damage before use.
Do not use if live components are damaged.
Prevent the live components from coming into contact with liquids.
Do not place live components near naked flames.
Do not tamper with live components.
Do not kink the cables or put undue weight on them.
NOTE
In the case of cascade circuits, the loop resistance must be taken into account
If the maximum number of multiple outlet strips is exceeded, a specialist must measure
and approve the loop resistance.
2023, 62913788/B 5/20
PRODUCT DESCRIPTION
EN
3 Product description
1 Feed cable (1x power plug/1x GST-18 plug)
2 Connecting cable (2x GST-18 plug)
3 Multiple outlet strip with holder
4 Multiple outlet strip Desk 2
5 GST-18 protective cap
6 Distribution black box with holder
7 Swiss distribution black box with holder
8 Strain relief
9 Hook and fleece strips for attaching cable
10 Cable bands for attaching cable
6/20 2023, 62913788/B
EN
CONCEPT FOR ELECTRIFICATION
4 Concept for electrification
4.1 Series connection
1 Feed cable
2 Strain relief
3 Cable fastener
4 Connecting cable
5 Multiple outlet strip with holder
2
3
4
1
5
2023, 62913788/B 7/20
CONCEPT FOR ELECTRIFICATION
EN
4.2 Parallel connection
1 Feed cable
2 Strain relief
3 Cable fastener
4 Connecting cable
5 Multiple outlet strip with holder
6 Distribution black box with holder / Swiss distribution black box with holder
2
3
4
16
5
8/20 2023, 62913788/B
EN
CONCEPT FOR ELECTRIFICATION
4.3 Series connection mixed with parallel connection
1 Feed cable
2 Strain relief
3 Cable fastener
4 Connecting cable
5 Multiple outlet strip with holder
6 Distribution black box with holder / Swiss distribution black box with holder
2
3
1
4
5
6
2023, 62913788/B 9/20
MOUNTING PRINCIPLE AND INSTRUCTIONS
EN
5 Mounting principle and instructions
5.1 Example wiring
1 Feed cable from the floor
2 Feed cable, for example, from the ceiling
1
1
2
10/20 2023, 62913788/B
EN
MOUNTING PRINCIPLE AND INSTRUCTIONS
5.2 Specifications for the wiring
NOTE
To ensure safe use, the individual points on cable routing must be observed.
General information
Electrical components are not to be mounted on the exterior; cables must always be
routed on the inside of the furniture. Danger of snagging when walking by.
Current outputs of the GST-18 sockets that are not used must be covered.
Load on GST-18 plug connections must always be avoided.
1
29
4
5
6
8
3
Rmin. 50
7
Rmin. 50
Rmin. 50
10
1
11
2023, 62913788/B 11/20
MOUNTING PRINCIPLE AND INSTRUCTIONS
EN
Feed cables
Where necessary, feed cables must be clearly marked; see point 5.2.1 "Marking of sepa-
rate circuits".
Make sure that the feed cables do not become trip hazards (1).
Either all power plugs themselves must be directly accessible or, optionally, the appropri-
ate circuit breaker must be accessible and marked.
Each feed cable must be fused separately.
One permanently mounted strain relief (2) must be fitted for each cable line that is routed
up from below.
NOTE
UK: The feed cable may have a maximum length of 2 m from the outlet of the furniture (11)
Connecting cables and feed cables
A minimum bending radius of Rmin. = 50 mm must be observed (7/10).
Attach cable fasteners immediately before and after the bending radius (3).
Maximum distance between two cable fasteners 40 cm (4).
Attach cable fasteners immediately after the transition between plug connections (5).
Cables between cable fasteners may not be subjected to any load (6).
Multiple outlet strips (8)
The number of multiple outlet strips or sockets per circuit must be taken into account on a
country-specific basis.
Multiple outlet strips should be easily accessible and must not be used while covered.
All multiple outlet strips must be fixed according to specifications; see point (6.1 "Installa-
tion of multiple outlet strip and Swiss distribution black box").
Do not insert heavy plug devices into the multiple outlet strips (max. 50 g).
Do not install multiple outlet strips in the lower area (9).
NOTE
For the assembly of the electrification system, observe assembly instruc-
tions “General electrification” 71025424.
12/20 2023, 62913788/B
EN
MOUNTING PRINCIPLE AND INSTRUCTIONS
5.2.1 Marking of separate circuits
NOTE
All separate circuits shall be clearly recognisable/identifiable at the lead cables, electric
sockets, and distributors.
Any required markings must be made on site during installation.
!
!! !
2023, 62913788/B 13/20
ASSEMBLY
EN
6 Assembly
6.1 Installation of multiple outlet strip and Swiss distribution black
box
3.
2.
1.
1. 2. 3.4.
14/20 2023, 62913788/B
EN
ASSEMBLY
6.2 Fitting the distributor
6.3 Fitting the cable fasteners
Hook and fleece strips
1. 2. 3. 4.
1. 2. 3. 4.
2023, 62913788/B 15/20
ASSEMBLY
EN
Cable bands
6.4 Installation position of multiple outlet strip Desk 2
Cable routing, see point 5.2 "Specifications for the wiring"
16/20 2023, 62913788/B
EN
ASSEMBLY
6.5 Fitting strain relief
3.
4.
2.
1.
2023, 62913788/B 17/20
ASSEMBLY
EN
6.6 Fitting GST-18 protective cap
DANGER
Electric shock
Danger of fatal injury and risk of damage to property
Disconnect the power supply before mounting / removing the GST-
18 protective caps!
NOTE
Only remove the GST-18 protective caps with non-conductive or insulated tools.
18/20 2023, 62913788/B
EN
CHECKLIST
7 Checklist
Are all s
upply line power plugs either directly accessible or is the appropriate circuit
breaker marked and accessible so that the power supply can be disconnected at any
time?
Are all circuits individually fused?
Can the individual circuits be identified wit
h the feed cable or circuit breaker?
Have the country
-specific specifications regarding fuse protection, max. power and
number of socket inserts / multiple outlet strips been taken into account?
Are all feed cables that are routed up from below
secured with strain reliefs?
Has the cable bending radii of Rmin. = 50
mm been observed?
Are all components assembled / fixed according to the specifications?
Are all GST
-18 plugs correctly connected to the GST-18 sockets and clipped in place?
Are all GST
-18 plug connections fitted without loads?
Are all cable fasteners fitted according to the specifications?
Make sure there are no live components mounted on the exterior (snagging).
Make sure there are no live
components mounted in the lower area except for the
feed cable.
Are all live components free of damage?
Are all unused GST
-18 current outputs closed with a protective cap?
2023, 62913788/B 19/20
NOTES
EN
8 Notes
Vitra Factory GmbH
Charles
-Eames-Strasse 2
79576 Weil am Rhein
Germany
www.vitra.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

VITRA Comma Assembly Instructions

Type
Assembly Instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI