Omega Engineering OMEGASCOPE OS533E Owner's manual

Category
Digital body thermometers
Type
Owner's manual
OS530LE, OS532E, OS53xE-CF,
OS533E, OS534E, OS530HRE,
OS523E, OS524E OMEGASCOPE
®
Handheld Infrared Thermometer
Shown with
Built-in Distance
Measuring Option
TM
omega.com
For latest product manuals:
omegamanual.info
Users Guide
Shop online at
CAUTION!
– This product
is not intended for medical
use or use on humans
MADE IN
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047
Toll-Free: 1-800-826-6342 Tel: (203) 359-1660
FAX: (203) 359-7700 e-mail: [email protected]
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada
Toll-Free: 1-800-826-6342 TEL: (514) 856-6928
FAX: (514) 856-6886 e-mail: [email protected]
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
FAX: +31 20 643 46 43 e-mail: [email protected]
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic
Toll-Free: 0800-1-66342 TEL: +420-59-6311899
FAX: +420-59-6311114 e-mail: [email protected]
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00
FAX: +33 (0) 130 57 54 27 e-mail: [email protected]
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany
Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0
FAX: +49 (0) 7056 9398-29 e-mail: [email protected]
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified
One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611
FAX: +44 (0) 161 777-6622 e-mail: [email protected]
OMEGAnet
®
Online Service Internet e-mail
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European New
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
Unpacking Instructions
n4
Notes
Unpacking Instructions
Remove the Packing List and verify that you have received all
equipment, including the following (quantities in parentheses):
• OS530E/OS520E Series Handheld Infrared Thermometer (1)
• AA Size Lithium Batteries (4)
• Soft Cover Carrying Case (1)
• Analog Cable (1)
• RS232 Cable (only for OS533E, OS534E, OS523E, OS524E)
• CD Software (only for OS533E, OS534E, OS523E, OS524E)
• Quick Start Manual (1)
• Mini-Tripod
Accessories
If you have any questions about the shipment, please call Customer
Service at:
1-800-622-2378 or 203-359-1660. We can also be reached on the
Internet at:
omega.com
When you receive the shipment, inspect the container and equipment
for signs of damage. Note any evidence of rough handling in transit.
Immediately report any damage to the shipping agent.
The carrier will not honor damage claims unless all shipping
material is saved for inspection. After examining and removing
contents, save packing material and carton in the event
reshipment is necessary.
Model No. Description
UNIV-AC--100/240 100-240 Vac adapter, 9 Vdc @1.7A
OS520-RCC Hard Carrying Case, Standard
OS520-SC-RCC Hard Carrying Case, Large
88013K Surface Probe, K Type T/C, up to 815°C (1500°F)
88001K Surface Probe, K Type T/C, up to 482°C (900°F)
CAL-3-IR NIST Traceable Calibration
SC-520A Sighting Scope
HH-DM Distance Measuring Meter
NOTE
i
ii
TABLE OF
CONTENTS
Page
Unpacking Instructions i
Chapter 1 General Description 1-1
1.1 Introduction 1-1
1.2 Parts of the Thermometer 1-5
1.2.1 Front of the Thermometer 1-5
1.2.2 Rear of the Thermometer 1-7
Chapter 2 Using the Handheld Infrared Thermometer 2-1
2.1 How to Power the Thermometer 2-1
2.1.1 Battery Operation 2-1
2.1.2 AC Power Operation 2-1
2.2 Operating the Thermometer 2-2
2.2.1 Measurement Techniques 2-6
2.3 Real Time Mode (Active Operation) 2-8
2.3.1 Adjusting Emissivity 2-11
2.3.2 Using the LOCK Function 2-11
2.3.3 Using the Trigger Function 2-11
2.3.4 Using the Distance Function 2-12
2.3.5 Laser Sighting Status 2-15
2.3.6 Calculating Temperature Values 2-15
2.3.7 Changing the Temperature from °F to °C (or vice versa) 2-16
2.3.8 Turning on the Display Backlighting 2-16
2.3.9 Thermocouple Input (OS532E, OS533E, OS534E) 2-16
2.3.10 Using the Alarm Functions 2-17
2.3.11 Using Ambient Target Temperature Compensation 2-19
(OS533E, OS534E, OS523E, OS524E)
2.3.12 PC User Application (OS533E, OS534E, OS523E, OS524E) 2-20
2.3.13 PC Interface Commands 2-25
2.3.14 Storing Temperature Data on Command 2-27
(OS533E, OS534E, OS523E, OS524E)
2.3.15 Logging Temperature Data in Real Time 2-28
(OS533E, OS534E, OS523E, OS524E)
2.3.16 Erasing the Temperature Data from Memory 2-29
2.4 Recall Mode (Passive Operation) 2-30
2.4.1 Reviewing the Last Parameters 2-32
2.4.2 Reviewing Previously Stored Temperature Data 2-32
(OS534E, OS523E, OS524E)
Chapter 3 Laser Sighting 3-1
3.1 Warnings and Cautions 3-1
3.2 Description 3-2
3.3 Operating the Laser Sighting 3-3
3.4 Laser Sighting Status 3-3
Chapter 4 Sighting Scope 4-1
4.2 Installing and Operating the Sighting Scope 4-1
OS530E/OS520E Series
Handheld Infrared Thermometer
iii
iv
Chapter 5 Maintenance 5-1
5.1 Replacing the Batteries 5-1
5.2 Cleaning the Lens 5-2
5.3 Calibrating the Thermometer 5-2
5.4 Servicing the Laser Sighting 5-2
Chapter 6 Troubleshooting Guide 6-1
Chapter 7 Specifications 7-1
Chapter 8 Glossary of Key Strokes 8-1
Appendix A How Infrared Thermometry Works A-1
Appendix B Emissivity Values B-1
Appendix C Determining an Unknown Emissivity C-1
Index I-1
TABLE OF
CONTENTS
1-1
General Description
1
1.1 Introduction
The OS530E/OS520E series Handheld Infrared (IR) Thermometers
provide non-contact temperature measurements up to 4500°F. They
offer effective solutions for many non-contact temperature
applications, including the following:
Predictive Maintenance: Tracking temperature shifts which
indicate pending failure in solenoid valves.
Energy Auditing: Locating wall insulation voids to reduce
building heating costs.
Food Processing: Taking accurate temperature readings without
direct contact with the food or packaging material.
The IR thermometer provides information at a glance — the custom
backlit dual digital LCD displays both current and minimum,
maximum, average or differential temperatures. This versatile
instrument provides:
Measurable target distances from 5 inches to approximately 100
feet
Emissivity adjustable from 0.1 to 1.00 in 0.01 steps provides ease
of use when measuring a variety of surfaces.
Built-in Laser sighting in Circle & Dot configurations.
Thermocouple input available.
Distance Measurement available, either field mountable or built-
in.
An electronic trigger lock feature set via the keypad allows
continuous temperature measurement up to 10 times per second.
Audible and visual alarms. The high and low alarm points
are set via the keypad.
1 mV per degree (°F or °C) analog output, which allows
interfacing with data acquisition equipment (including
chart recorders, dataloggers and computers). OS524E provides 0.5
mV/Deg.
Last temperature recall (Hold).
Backlit display useful in low ambient light conditions.
Powers from 4 AA size batteries or an ac adapter.
RS232 serial communication to a PC or printer with data logging
software. This allows downloading data for further analysis.
Ambient target temperature compensation. This provides more
accuracy for measuring low emissivity targets.
Record up to 800 temperature data points. Review the recorded
data on the thermometer LCD, as well as downloading the data
to a PC.
General Description
1
1-2
The thermometer is easy to use:
Units have standard “V” groove aiming sights.
Integral tripod mount permits hands-free operation, if necessary.
Temperature readings are switchable from °F to °C via the keypad.
Parameters, such as target material emissivity and alarm setpoints, can
be set and remain in memory until reset.
This instrument has a rugged and functional design, including:
Sealed keypad display.
Convenient trigger operation.
Soft carrying case and wrist strap, for safety and ease of carrying.
Rubber boot around the lens and the display.
Table 1-1. OS530 Series Handheld Infrared Thermometer Features
Features
OS530LE OS532E OS533E OS534E OS534E-LR
Accuracy* ±1% rdg ±1% rdg ±1% rdg ±1% rdg ±1% rdg
Range -10 to 1000°F -10 to 1000°F -10 to 1000°F -10 to 1600°F -10 to 1600°F
-23 to 538°C -23 to 538°C -23 to 538°C -23 to 871°C -23 to 871°C
Emissivity adjustable adjustable adjustable adjustable adjustable
Backlit Dual Display standard standard standard standard standard
Distance to Spot
Size Ratio 10:1 10:1 20:1 30:1 110:1
Differential Temp. standard standard standard standard standard
Min/Max Temperature standard standard standard standard standard
Average Temperature standard standard standard standard standard
High Alarm standard standard standard standard standard
Thermocouple Input standard standard standard standard
Audible Alarm
& Indicator standard standard standard standard standard
Analog Output 1mV/deg 1mV/deg 1mV/deg 1mV/deg 1mV/deg
Built-in Laser Sighting dot/circle dot/circle dot/circle dot/circle dot/circle
Trigger Lock standard standard standard standard standard
Last Temp. Recall standard standard standard standard standard
Low Alarm standard standard standard
Ambient Target
Temperature standard standard standard
Compensation
RS232 Interface standard standard standard
Data Storage standard standard
Distance Measurement Optional
1-3
General Description
1
Features
OS530HRE OS530LE-CF OS533E-CF OS534E-CF
Accuracy* 3°F (1.7 °C) ±1% rdg ±1% rdg ±1% rdg
Range -22 to 250°F -10 to 1000°F -10 to 1000°F -10 to 1600°F
-30 to 121°C -23 to 538°C -23 to 538°C -23 to 871°C
Emissivity Adjustable Adjustable Adjustable Adjustable
Display Resolution 0.1°For 0.1°C 1°F or 1°C 1°F or 1°C 1°F or 1°C
Backlit Dual std std std std
Display
Field of view 20:1 0.15"@6" 0.15"@6" 0.15"@6"
Differential
Temperature std std std std
Min/Max
Temperature std std std std
Average
Temperature std std std std
High Alarm std std std std
Low Alarm --- --- std std
Audible Buzzer
& Indicator
std std std std
Ambient Target
Temp --- --- std std
Compensation
Analog Output 1 mV/Deg 1 mV/Deg 1 mV/Deg 1 mV/Deg
RS232 Output --- --- std std
Data Storage --- --- --- std
Built-in Laser Dot/Circle Dot Dot Dot
sighting
Trigger Lockstd std std std std
Last Temperature
Recall std std std std
Thermocouple
Input --- --- std std
Distance Optional Not Recommended
Measurement
* The temperature accuracy is 1% of Rdg or 2ºC (3ºF) whichever is greater.
General Description
1
1-4
Distance to Spot Size Ratio
OS523E-1 30:1
OS523E-2 60:1
OS523E-3 68:1
OS523E-LR 110:1
** OS523E provides four field of views:
Features OS523E
**
OS524E
Accuracy ±1% rdg ±1% rdg
Range 0 to 2500°F 1000 to 4500°F
(-18 to 1371°C) (538 to 2482°C)
Emissivity adjustable adjustable
Backlit Dual Display standard standard
Distance to Spot Size Ratio varies** 110:1
Differential Temperature standard standard
Min/Max Temperature standard standard
Average Temperature standard standard
High Alarm standard standard
Low Alarm standard standard
Audible Alarm & Indicator standard standard
Ambient Target
standard standard
Temperature Compensation
Analog Output 1 mV/deg 0.5 mV/deg
RS-232 Output standard standard
Thermocouple Input ––– –––
Data Storage standard standard
Built-in Laser Sighting dot/circle dot/circle
Trigger Lock standard standard
Last Temperature Recall standard standard
Distance Measurement Optional
1.2 Parts of the Thermometer
1.2.1 Front of the Thermometer
Figure 1-1. OS530E/OS520E Series Handheld Infrared Thermometer Front View
The display is shown in more detail in Figure 1-2 and described in Table 1-2.
There are no user-serviceable parts in the thermometer.
Refer to Chapter 3 for Laser Sight information.
TM
“V” Groove
Lens Rubber
Boot
Built-in
Distance Module
(Optional)
Distance
Power
Switch
Trigger
Battery
Compartment
Door
Display
Rubber
Boot
Backlit
LCD
Wrist
Strap
1-5
General Description
1
General Description
1
1-6
Figure 1-2.
Display and
Keypad View
Table 1-2. Display
Details
Key Description
Display Mode displays one of the following:
E (Emissivity) AVG (Average Temperature)
d_F (distance in Feet) HAL (High Alarm Setpoint)
d_M (Distance in Meters) TC (Thermocouple Input)
LSR (Laser either flashing or continuous) LAL (Low Alarm Setpoint)
MAX (Maximum Temperature) AMB (Ambient Target Temp)
MIN (Minimum Temperature) PRN (Send Data to PC)
dIF (Differential Temperature) MEM (Store Individual Temperature Data)
LOG (Log Temperature Data)
Data associated with one of the Display Modes
Backlighting Icon - allows the display to be viewed under low ambient light
Displays the units of measure in either °F or °C
Main display - displays the current temperature
Locks the trigger / Enables or Disables alarms/Resets MAX, MIN, Dif, Avg. Temps
for incrementing data; and is for turning on/off the display backlighting
for decrementing data; and is for changing the units of measure from °F to °C or vice
versa
Function key for scrolling through the display modes
Display Icons
Trigger Lock Low Alarm
Ambient Target Low Battery
High Alarm Data Transfer thru RS232
Laser Power Indicator LED
F
C
FUNC LOCK
®
F
C
OMEGASCOPE
®
LCK
HAL
LOBAT
ATC
LAL
PRN
°F °C
1
11
10
9
8
7
6
5
4
3
2
1-7
General Description
1
Figure 1-3 shows the various jacks for analog output, thermocouple input
and the ac adapter to the thermometer. The figures also show the location of
the Laser Power Switch, Dot-Circle Switch, and Laser Beam Aperture. More
details are provided in Section 2.2.1.
Figure 1-3. OS530E/OS520E Series Handheld Infrared Thermometer
Various Views
Laser
Dot/Circle
Switch
Laser
Power
Switch
Distance
Power
Switch
Laser Beam
Aperture
Thermocouple Input
Socket (SMP)
(standard on OS532E,
OS533E, OS534E)
ac Adapter Input Jack
Analog Output Jack (1mV/deg)
RS-232 Phone Jack
(standard on OS533E,
OS534E, OS523E, OS524E)
General Description
1
1-8
Notes
2-1
Using the Handheld Infrared Thermometer
2
2.1 How to Power the Thermometer
2.1.1 Battery Operation
Invert the thermometer and install 4 fresh AA size batteries as shown in
Figure 2-1. Make sure the batteries’ polarities are correct, the batteries are
not put in backwards, and are of the same type.
If the icon flashes, the batteries must be
replaced with fresh batteries immediately.
Figure 2-1. Installing the Batteries
2.1.2 ac Power Operation
The thermometer may be operated on ac power using the optional
universal 100/240 Vac adapter. When operating on ac power the batteries
supply backup power in case of ac power failure. The ac adapter input jack
is shown in Figure 1-3.
FU
NC LOC
K
®
F
C
O
M
E
G
A
S
COPE
®
LC
K
H
A
L
L
O
B
A
T
A
TC
LAL
PRN
°
F
°
C
NOTE
Using the Handheld Infrared Thermometer
2
2-2
2.2 Operating the Thermometer
1a. (Without the Laser Sighting) -Aim the thermometer at the target to
be measured. Use the “V” groove (shown in Figure 1-1) on top of
the thermometer to align the target to the thermometer’s field of
view. Look down the “V” groove with one eye only, in order to
guarantee proper sighting. Pull and hold the trigger.
1b. (With the Laser Sighting) - Set the laser power switch to the
ON position. Aim at the target and pull the trigger. The laser
beam and the red power indicator LED will turn on while the
trigger is pulled. Refer to Chapter 3 for more details on the Laser
Sighting.
2. The field of view of the thermometer should fall within the area
of the target being measured as shown in Figure 2-2. Figures 2-3
through 2-9 show the field of view vs distance for the various
thermometers.
Figure 2-2. Field of View Positions
Figure 2-3. Field of View OS532E, OS530LE
Field of View
Target
(ACCEPTABLE)
(UNACCEPTABLE)
SPOT DIA. * (IN)
SPOT DIA. * (CM)
2-3
Using the Handheld Infrared Thermometer
2
** Measurement distance is from the outside surface of the rubber boot.
4.8"
1.0" @ 0" to 20"
2.5cm @ 51cm
1.2"
1.0"
2.5
6.0
4.0
8.0
10.0
12.2
1601208040
1.0"
1.8"
2.4"
3.0"
3.6"
4.2"
1' 2'
200
8'6'
0**
DISTANCE: SENSOR TO OBJECT (FT)
DISTANCE: SENSOR TO OBJECT (CM)
SPOT DIA.* (IN)SPOT DIA.* (CM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S = 20:1
4'
244
3' 5' 7'
20"
Figure 2-5 Field of View OS534E, OS523E-1
Figure 2-4 Field of View OS533E, OS530HRE
Using the Handheld Infrared Thermometer
2
2-4
Figure 2-7 Field of View OS523E-2
2.9"
0.9"@ 0
1.9"
22mm @ 0
1.2"
1.0"
31
26
48
75
0.9"
0'
3'
16'10'
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S
=
60:1
5'
5.0
0
1.0 3.01.5
Figure 2-6 Field of View OS53xE-CF
.45"
11.5
3"
SPOT DIA.* (MM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
7.6
SPOT DIA.* (IN)
DISTANCE: SENSOR LENS TO OBJECT (in.)
DISTANCE: SENSOR LENS TO OBJECT (cm.)
15.2
6"
9" 12"
15"
.15"
.39"
.78"
1.17"
3.9
9.9
19.9
29.9
D:S = 40:1
22.9
30.5
38.1
0.9"
22
0
0
2-5
Using the Handheld Infrared Thermometer
2
Figure 2-8 Field of View OS523E-3
7.0"
.35"@ 24"
1.6"
9mm @ 610mm
.8"
21
42
181
.9"
22
4.0"
101
0’
3
16’10’2’ 5’
SPOT DIA.* (MM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
5.0
0
.61
1.5
1.0
3.0
SPOT DIA.* (IN)
DISTANCE: SENSOR TO OBJECT (FT)
DISTANCE: SENSOR TO OBJECT (M)
Figure 2-9 Field of View OS524E
8.7"
0.5"@ 0
5.1"
13mm @ 0
1.5"
38
130
221
0.9"
0' 16' 82'50'
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S
=
110:1
25
0
5 15
DISTANCE: SENSOR TO OBJECT (FT)
SPOT DIA.* (MM)
SPOT DIA.* (IN)
DISTANCE: SENSOR TO OBJECT (M)
Figure 2-9B Field of View OS534E-LR, OS523E-LR
3.0"
1.0" @ 0
2.0"
2.5"
25.4 mm @ 0
1.5"
38
50
64
76
1.0"
0' 5' 18'10' 14'
DISTANCE: SENSOR TO OBJECT (M)
SPOT DIA.* (IN)
SPOT DIA.* (MM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S
=
1 10:1
5.5
0
1.5
3
4.2
DISTANCE: SENSOR TO OBJECT (FT)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

Omega Engineering OMEGASCOPE OS533E Owner's manual

Category
Digital body thermometers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI