Revised: July 2017
Aeration Fan
Inline Centrifugal Fan
Installation, Operation, and Parts Manual
This manual applies to:
GGI-803XX, GGI-805XX, GGI-807XX, GGI-810XX
Original Instructions
INSTALLATION AND WIRING MUST BE IN
ACCORDANCE WITH CEC, NEC, AND LOCAL
ELECTRICAL CODES
We strongly recommend that all personnel associated with this equipment be trained in the correct operational
and safety procedures required for this product. This product has been designed and constructed according to
general engineering standards, other local regulations may apply and must be followed by the operator. Use the
sign-off sheet below to record initial and periodic reviews of this manual with all such personnel.
Date Employee Signature Employer Signature
New Fan Features
Change Description
Control box change Control box size and construction altered from
previous models.
Thermal overload relay Thermal overload relay now added to control circuit,
no need for field wiring of external unit.
Control box vibration isolation Control box now isolated from fan vibration.
New in this Manual
The information below summarizes the changes to this manual since the last revision in April 2016.
Description Section
Electrical schematics updates Section 7.1. – Electrical Schematics on page 31
Troubleshooting updates Section 6. – Troubleshooting on page 29
New components Section 7.2. – Parts List on page 33
4 INA-1814 R5
AERATION FAN – INLINE CENTRIFUGAL FAN
AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 5
CONTENTS
1. Introduction ............................................................................................................................................ 7
1.1. General Description.................................................................................................................. 7
1.2. Serial Number Location............................................................................................................ 7
1.3. Intended Use ............................................................................................................................ 8
2. Safety....................................................................................................................................................... 9
2.1. Safety Alert Symbol and Signal Words..................................................................................... 9
2.2. General Safety .......................................................................................................................... 9
2.3. Fan Safety ............................................................................................................................... 10
2.4. Guards Safety ......................................................................................................................... 10
2.5. Lockout/Tagout Safety ........................................................................................................... 10
2.6. Electric Motor Safety.............................................................................................................. 11
2.7. Personal Protective Equipment.............................................................................................. 11
2.8. Safety Equipment ................................................................................................................... 11
2.9. Safety Decals .......................................................................................................................... 12
2.9.1 Decal Installation/Replacement............................................................................... 12
2.9.2 Safety Decal Locations and Details .......................................................................... 12
3. Installation ............................................................................................................................................ 19
3.1. Installation Safety................................................................................................................... 19
3.2. Check Shipment...................................................................................................................... 19
3.3. Handling the Fan .................................................................................................................... 19
3.4. Storing the Fan Before Installing............................................................................................ 19
3.5. Installing with a Supplemental Heater................................................................................... 20
3.6. Transition Connection Requirements .................................................................................... 20
3.7. Mounting the Fan on a Flat Bottom Bin ................................................................................ 20
3.7.1 Slab Mounted Fans................................................................................................... 20
3.8. Mounting the Fan on a Hopper Bottom Bin .......................................................................... 21
3.9. Electrical Connection.............................................................................................................. 21
3.10. Testing .................................................................................................................................. 23
4. Operation .............................................................................................................................................. 24
4.1. Operation Safety .................................................................................................................... 24
4.2. Start-Up and Break-In............................................................................................................. 24
4.3. Roof Vents .............................................................................................................................. 24
4.4. Fan Rotation and Orientation ................................................................................................ 25
4.5. Emergency Stop...................................................................................................................... 25
4.6. Shutdown ............................................................................................................................... 26
4.7. Storage.................................................................................................................................... 26
5. Maintenance ......................................................................................................................................... 27
5.1. Maintenance Safety ............................................................................................................... 27
5.2. Maintenance Schedule........................................................................................................... 27
5.3. Visually Inspect the Inline Fan................................................................................................ 28
5.4. Cleaning the Fan Blade and Housing ..................................................................................... 28
5.5. Servicing and Part Replacement ............................................................................................ 28
6. Troubleshooting.................................................................................................................................... 29
7. Appendix ............................................................................................................................................... 31
7.1. Electrical Schematics .............................................................................................................. 31
AERATION FAN – INLINE CENTRIFUGAL FAN
6 INA-1814 R5
7.2. Parts List ................................................................................................................................. 33
7.2.1 Grain Guard Inline Centrifugal Fan GGI-803XX ................................................... 33
7.2.2 Grain Guard Inline Centrifugal Fan GGI-805XX ................................................... 34
7.2.3 Grain Guard Inline Centrifugal Fan GGI-807XX ................................................... 35
7.2.4 Grain Guard Inline Centrifugal Fan GGI-810XX ................................................... 36
7.3. Grain Drying and Aeration Tips.............................................................................................. 37
8. Warranty ............................................................................................................................................... 41
INA-1814 R5 7
1. Introduction
Thank you for purchasing a Grain Guard Aeration Fan. This equipment will allow safe and efficient
operation when you read and follow all of the instructions contained in this manual. With proper care,
your inline fan will provide you with many years of trouble-free operation.
Keep this manual handy for frequent reference and to review with new personnel. A sign-off form is
provided on the inside front cover for your convenience. If any information in this manual is not
understood or if you need additional information, please contact your local distributor or dealer for
assistance.
This manual should be regarded as part of the equipment. Suppliers of both new and second-hand
equipment are advised to retain documentary evidence that this manual was provided with the
equipment.
1.1. General Description
The Grain Guard Aeration Fan is an excellent addition to any new or existing bin. It can allow you to harvest in
damp conditions, maintain stored grain in peak condition, and reduce the likelihood of mould growth and insect
infestations. With proper care during and after installation, your fan will provide you with many years of
trouble-free service.
1.2. Serial Number Location
Always give your dealer the serial number on your inline fan (shown below) when ordering parts or requesting
service or other information. Please record this information in the table below for easy reference.
Model Number
Serial Number
Date Received
AERATION FAN – INLINE CENTRIFUGAL FAN 1. INTRODUCTION
8 INA-1814 R5
1.3. Intended Use
The inline fan is designed solely for use in the intended agricultural use as listed below. Use in any other way is
considered as contrary to the intended use. Compliance with and strict adherence to the conditions of
operation and maintenance as specified by the manufacturer, also constitute essential elements of the intended
use.
The inline fan should be operated, maintained, serviced, and repaired only by persons who are familiar with its
particular characteristics and who are acquainted with the relevant safety procedures.
Accident prevention regulations and all other generally recognized regulations on safety and occupational
medicine must be observed at all times.
Any modifications made to the inline fan may relieve the manufacturer of liability for any resulting damage or
injury.
Intended use for the inline fan:
Aeration and natural air drying of grain products.
Connection to a Grain Guard downstream heater (if required).
Use in any other way is considered as contrary to the intended use and is not covered by the warranty.
1. INTRODUCTION AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 9
2. Safety
2.1. Safety Alert Symbol and Signal Words
This safety alert symbol indicates important safety messages in this manual. When you see
this symbol, be alert to the possibility of injury or death, carefully read the message that
follows, and inform others.
Signal Words: Note the use of the signal words DANGER,WARNING,CAUTION, and NOTICE with the safety
messages. The appropriate signal word for each message has been selected using the definitions below as a
guideline.
Indicates an imminently hazardous situation that, if not avoided, will result in serious injury or
death.
Indicates a hazardous situation that, if not avoided, could result in serious injury or death.
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation that, if not avoided, may result in property damage.
2.2. General Safety
The safety information in the safety section of this manual applies to all safety practices. Specific safety
information (such as Operation Safety), can be found in the appropriate section.
YOU are responsible for the SAFE use and maintenance of your inline fan. YOU must ensure that you and
anyone else who is going to work around the inline fan understands all procedures and related SAFETY
information contained in this manual.
Remember, YOU are the key to safety. Good safety practices not only protect you, but also the people around
you. Make these practices a working part of your safety program. All accidents can be avoided.
It is the inline fan owner, operator, and maintenance personnel's responsibility to
read and understand ALL safety instructions, safety decals, and manuals and follow
them when assembling, operating, or maintaining the equipment.
Owners must give instructions and review the information initially and annually with all personnel before
allowing them to operate the inline fan. Untrained users/operators expose themselves and bystanders to
possible serious injury or death.
The inline fan is not intended to be used by children.
Use the inline fan for its intended purposes only.
Do not modify the inline fan in any way without written permission from the manufacturer. Unauthorized
modification may impair the function and/or safety, and could affect the life of the inline fan. Any
unauthorized modification of the inline fan will void the warranty.
AERATION FAN – INLINE CENTRIFUGAL FAN 2. SAFETY
10 INA-1814 R5
2.3. Fan Safety
Keep away from fan impeller/blade; high suction can pull a
person toward the inlet. Contact with an unguarded
impeller/blade will cause severe injury.
Keep the inlet screen in place at all times.
Remove foreign material from the fan inlet before operating.
Do not operate the fan if there is excessive vibration or noise.
When the power is locked out, fans can still be dangerous
because of potential “windmilling.” Always block the
impeller/blade before working on any moving parts.
2.4. Guards Safety
Keep guards in place. Do not operate with guard removed.
Do not walk on, step on, or damage guards.
Lock out power before removing a guard.
Ensure all guards are replaced after performing maintenance.
2.5. Lockout/Tagout Safety
Lockout/Tagout equipment before set-up, service, maintenance, and repair. Make sure to follow lockout and
tagout procedure in the Electric Motor Safety Section to prevent inadvertent start-up and hazardous energy
release.
2. SAFETY AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 11
2.6. Electric Motor Safety
Power Source
Electric motors and controls shall be installed and serviced by
a qualified electrician and must meet all local codes and
standards.
Do not modify the magnetic starter. This component provides
overload and under-voltage protection.
Motor starting controls must be located so that the operator
has full view of the entire operation.
Locate main power disconnect switch within reach from
ground level to permit ready access in case of an emergency.
Motor must be grounded.
Guards must be in place and secure at all times.
Ensure electrical wiring and cords remain in good condition;
replace if necessary.
SERVICE DISCONNECT
ON
OFF
Lockout
The main power disconnect switch should be in the locked position during shutdown or
whenever maintenance is performed.
In the event of unexpected fan shutdown, the fan can be reset using the main power switch
located on the fan or using a reset button when equipped.
2.7. Personal Protective Equipment
The following Personal Protective Equipment (PPE) should be worn when operating or maintaining the
equipment.
Work Gloves
Wear work gloves to protect your hands from sharp and rough edges.
2.8. Safety Equipment
The following safety equipment should be kept on site:
Fire Extinguisher
Provide a fire extinguisher for use in case of an accident. Store in a highly visible and
accessible place.
AERATION FAN – INLINE CENTRIFUGAL FAN 2. SAFETY
12 INA-1814 R5
First-Aid Kit
Have a properly-stocked first-aid kit available for use should the need arise, and
know how to use it.
2.9. Safety Decals
Keep safety decals clean and legible at all times.
Replace safety decals that are missing or have become illegible. See decal location figures that follow.
Replaced parts must display the same decal(s) as the original part.
Replacement safety decals are available free of charge from your distributor, dealer, or factory.
2.9.1 Decal Installation/Replacement
1. Decal area must be clean and dry, with a temperature above 50°F (10°C).
2. Decide on the exact position before you remove the backing paper.
3. Align the decal over the specified area and carefully press the small portion with the exposed sticky backing
in place.
4. Slowly peel back the remaining paper and carefully smooth the remaining portion of the decal in place.
5. Small air pockets can be pierced with a pin and smoothed out using the sign backing paper.
2.9.2 Safety Decal Locations and Details
Replicas of the safety decals that are attached to the inline fan and their messages are shown in the figure(s)
that follow. Safe operation and use of the inline fan requires that you familiarize yourself with the various safety
decals and the areas or particular functions that the decals apply to, as well as the safety precautions that must
be taken to avoid serious injury, death, or damage.
2. SAFETY AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 13
Note
Electrical schematics (PN 601-4093 / 601-4095 / 601-4096 / 601-4097) attached under the electrical
enclosure lid will depend on the electric motor power source.
Electrical schematics are also shown in the Appendix section of this manual.
Voltage warning will be different for each type of electric motor that is used in this fan.
AERATION FAN – INLINE CENTRIFUGAL FAN 2. SAFETY
14 INA-1814 R5
Table 1. Safety Decals
Part Number Description
601–1992
To prevent possible roof damage,
ensure that all roof vents are open
and unobstructed.
Do not operate aeration fan if it is
possible that the roof vents could
ice up.
NOTICE
601–1993
To prevent serious injury or death:
Read operator’s manual and all product safety decals
before installing, operating or servicing fan.
Do not operate with any safety shield or guard
removed or modified. Keep in good working order.
Do not operate fan if there is excessive vibration or
noise.
Before operating fan, clear work area of all children
and untrained personnel.
Keep hands, legs, feet, hair, jewelry and clothing away
from all moving parts.
Shut off and lock out or disconnect power before
inspecting or servicing fan.
If the operator manual, guards, or safety decals
are missing or damaged, contact AGI Nobleford
at 1-800-565-2840 or www.aggrowth.com for
replacements.
AERATION FAN SAFETY INSTRUCTIONS
WARNING
2. SAFETY AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 15
Table 1 Safety Decals (continued)
Part Number Description
601–1994
CUTTING HAZARD
To prevent serious injury, keep away
from blade when fan is operating.
Shut off and lockout or disconnect power
before inspecting or servicing.
Keep guards in place while operating.
WARNING
CNA-1391
230 VOLTS
DANGER
CNA-1390
460 VOLTS
DANGER
CNA-1389
575 VOLTS
DANGER
CNA-1399
Disconnect electrical power at
service box before removing cover.
ELECTROCUTION HAZARD
WARNING
AERATION FAN – INLINE CENTRIFUGAL FAN 2. SAFETY
16 INA-1814 R5
Table 1 Safety Decals (continued)
Part Number Description
601–1995
To prevent serious injury or death:
Only qualified personnel should service
electrical components.
Disconnect and lockout power before
inspecting or servicing unit.
Keep electrical components in good repair.
ELECTROCUTION HAZARD
WARNING
CNA-1384
OFF - RUN - MOMENTARY
START
601–4093
2. SAFETY AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 17
Table 1 Safety Decals (continued)
Part Number Description
601–4095
601–4096
AERATION FAN – INLINE CENTRIFUGAL FAN 2. SAFETY
18 INA-1814 R5
Table 1 Safety Decals (continued)
Part Number Description
601–4097
2. SAFETY AERATION FAN – INLINE CENTRIFUGAL FAN
INA-1814 R5 19
3. Installation
Before continuing, ensure you have completely read and understood this manual’s
Safety section, in addition to the safety information in the section(s) below.
3.1. Installation Safety
Do not take chances with safety. The components can be large, heavy, and hard to handle.
Always use the proper tools, rated lifting equipment, and lifting points for the job.
Always have two or more people installing the inline fan.
Make sure you have sufficient lighting for the work area.
Tighten all fasteners according to their specifications. Do not replace or substitute bolts,
nuts, or other hardware that is of lesser quality than the hardware supplied by the
manufacturer.
3.2. Check Shipment
Inspect the inline fan and accessories on receipt to ensure that all items have arrived and that none are
damaged.
A few basic items to check:
Ensure no loose items or debris that can be drawn into the fan or dislodged by the fan discharge. Check the
interior of the fan as well.
Turn the fan impeller/blade by hand to check for binding.
Check the tightness of all nuts and bolts.
Verify that the supply voltage is correct.
Report missing or damaged parts immediately to ensure that proper credit is received from Grain Guard or your
distributor/dealer, and to ensure that any missing parts can be shipped quickly to avoid holding up the
installation.
Important
Do not use damaged components.
3.3. Handling the Fan
Lift the fan by the base, mounting supports, or lifting locations. Never lift a fan by the wheel, motor, motor
bracket, housing inlet, outlet, or any fan part not designed for lifting. A spreader should always be used to avoid
damage.
3.4. Storing the Fan Before Installing
Check the fan wheel for free operation and lubricate moving parts prior to storage if the fan is not to be placed
immediately into service. Inspect the stored unit periodically.
AERATION FAN – INLINE CENTRIFUGAL FAN 3. INSTALLATION
20 INA-1814 R5
3.5. Installing with a Supplemental Heater
Any type of supplemental heater intended for use with this fan must be installed downstream of this fan and
may be added if extra conditioning or drying is required.
Heating incoming air will damage the fan and its components and is not covered by the
warranty.
3.6. Transition Connection Requirements
When connecting the transition, ensure the fan fits properly with the grain bin transition intended for use by
the manufacturer.
3.7. Mounting the Fan on a Flat Bottom Bin
The inline fan must be properly supported for smooth operation.
3.7.1 Slab Mounted Fans
A concrete foundation is preferable for installing floor-mounted fans.
When installing the fan on a concrete pad the following general requirements apply:
The concrete surface must be flat and level.
The weight of the slab should be two to four times the weight of the rotating assembly, including the motor.
The foundation requires firmly anchored fasteners such as the anchor bolts shown below. Hammer-drilled
expansion fasteners can be used in less demanding applications.
The overall dimensions of the concrete base should extend at least six inches beyond the base of the fan.
Locate the fan as close to the bin as possible, leaving approximately 12” to 18” or more between the fan
and bin to allow for routine servicing and inspection.
Ensure moisture is not accumulating around the fan.
Move the fan to the mounting location and lower it over the anchor bolts, leveling the fan with shims
around the bolts. Fasten the fan securely.
When grout is used: Shim the fan at least 3/4-inch from the concrete base.
Item Description
1Transition (Not Load Bearing)
2Concrete Slab
3Concrete Anchor
4Adaptor
3. INSTALLATION AERATION FAN – INLINE CENTRIFUGAL FAN
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

AGI Inline Centrifugal Aeration Fan Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI