CAME GARD PT Series Installation guide

Type
Installation guide

This manual is also suitable for

EN
En
g
lish
FA01119-EN
Brushless automatic barrier
GARD PT series
GPT40AGS
INSTALLATION MANUAL
OFF
OFF
DANGER OF HIGH VOLTAGE
DANGER OF HAND ENTRAPMENT
DO NOT ENTER
CAUTION: Once you have released the barrier by using the corresponding key, we highly recommend to lock the barrier into place again once it
has opened, by turning the same key as shown in figure B.
Not locking the barrier back into place may result in it uncontrollably falling unless it is perfectly horizontal.
p. 3 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
GENERAL PRECAUTIONS FOR INSTALLERS
CAUTION! Important safety instructions.
Follow all of these instructions. Improper installation can cause serious bodily harm.
Before continuing, also read the general precautions for users.
Before doing any cleaning or maintaining or parts-replacing, cut o the mains power supply.
If there is a power outage and the barrier is not fi tted with an electric lock, strong gusts of wind could cause the barrier to descend
by itself in a controlled manner.
This product must only be used for its specifi cally intended purpose. Any other use is dangerous. Came S.P.A. is not liable for any
damage caused by improper, wrongful and unreasonable use. • This manual's product is defi ned by machinery directive 2006/42/
CE as "partly-completed machinery". Partly-completed machinery is a set that almost constitutes a machine, but which, alone,
cannot ensure a clearly defi ned application. Partly-completed machinery is only destined to be incorporated or assembled to
other machinery or other partly-completed machinery or apparatuses to build machinery that is regulated by Directive 2006/42/
CE. The fi nal installation must comply with Machinery Direction 2006/42/CE and current European reference standards. • Given
these considerations, all procedures stated in this manual must be exclusively performed by expert, qualifi ed sta . • Laying the
cables, installation and testing must follow state-of-the-art procedures as dictated by regulations • Make sure that the opening
automatic barrier does not constitute a hazard. • Do not install the operator onto surfaces that could yield and bend. If necessary,
add suitable reinforcements to the anchoring points • Make sure the temperature range shown on the product literature is
suitable to the climate where it will be installed. • Do not install on slopes, that is, on any surfaces that are not perfectly level. •
Check that no lawn watering devices spray the operator with water from the bottom up. •Check that there are no obstruction or
impediments near the cabinet. • During the set up and installing stages the barrier could be unstable and tip over. So, be careful
and do not lean on it until it is fully fastened.• Suitably section o and demarcate the entire installation site to prevent unauthorized
persons from entering the area, especially minors and children. • Be careful when manually moving weights of over 20 kg per
person; if manually moving such weights, use suitable and safe hoisting equipment . • Please use suitable protections to prevent
any mechanical hazards when people are moving around the machinery. • Any residual risks must be notifi ed by proper, clearly
visible pictograms, which must be explained to end users. • Fit, in plain sight, the machine's ID plate when the installation is
complete. • Install all fi xed commands at least 1.5 m from the ground where they will be clearly visible, within view of the part they
command but clear of any moving parts. Any maintained action commands must not be reachable by unauthorized persons. •
The manufacturer declines any liability for using non-original products, in which case the warranty will cease to be e ective. • For
booms longer than 2.5 m you must fi t a reinforcement on the boom itself, as shown later in this manual. • A x a permanent tag,
that describes how to use the manual release mechanism, close to the mechanism. • Before turning over to the fi nal user, check
that the system complies with the harmonized standards and the essential requisites of Machinery Directive 2006/42/CE. Make
sure that the operator has been properly adjusted and that the safety and protection devices, and the manual release, are working
properly. • Using original CAME control and safety devices and accessories ensures easy installation and system maintenance.• If
the power-supply cable is damaged, it must be replaced by the manufacturer or by the licensed technical-assistance center or by
duly trained, skilled sta , to prevent any risks. • During all phases of the installation make sure you have cut o the mains power
source. • The electrical cables must run through suitable tubes, conduits and cable glands to ensure they are protected against
mechanical damage, They must not touch any parts that may overheat during operation, such as the motor or the transformer. •
Set up a suitable dual pole cut o device along the power supply that is compliant with the installation rules. It should completely
cut o the power supply according to category III surcharge conditions. • When the passage width clearance is greater than 3
m, you must use a fi xed rest for the boom to support it. • Keep the section of this manual inside the technical folder along with
the manuals of all the other devices used for your automation system. Remember to hand over to the end users all the operating
manuals of the products that make up the fi nal machinery.
Figure shows a standard installation: used for motor vehicels. The main hazard points for people are shown in the diagram.
p. 3 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
3800 max
250
206.5
276
170
20
884
1133
1117
p. 4 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Limits to use
Model GPT40AGS
Maximum clearance width of the passage (m) 3.8
Technical data
Type GPT40AGS
Protection rating (IP) 44
Power supply (V - 50/60 Hz) 230 V
Input voltage motor (V) 36 DC
Stand-by consumption (W) 12
Power (W) 350
Torque (Nm)
80 (with no springs)
140 (with springs)
Opening time at 90° (s) 1.2 to 4
Cycles/h See table on page 14
Operating temperature (°C) -20 to +55
Reduction ratio (i) 1/56
Apparatus class I
Weight (Kg) 38.6
Dimensions
KEY
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues
This symbol shows which parts to tell users about.
Unless otherwise stated, these operations apply to all models.
The measurements, unless otherwise stated, are in millimeters.
DESCRIPTION
GPT40AGS- Automatic barrier with reversible gearmotor and brushless motor; painted aluminum cabinet ready to fit accessories.
Intended use
The automatic barrier is designed for private and public parking facilities.
Do not install of use this device in any way, except as specified in this manual.
p. 4 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
p. 5 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Description of parts
Motor-shaft plate
Boom-attachment cover
Protective casing shear proof
Fastening screws protective cover
Control panel
Boom setting mechanical stop
Gear motor with encoder
Lever arm
Cover
Cabinet
Inspection hatch
Anchoring plate
Anchoring bracket
Filter cover
Transformer cover
Lock for manual release
p. 5 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
1
3
7
4
2
5
8
1
6
p. 6 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Completion accessories
803XA-0050
Boom 90x35 (L= 4050)
803XA-0051
Boom 90x35 (L = 3050)
Accessories
803XA-0070
GARD PT spring unit
803XA-0010
GARD PT luminous gearwheel
803XA-0030
Electric lock assembly
803XA-0080
Auxiliary contacts for checking the position of the boom
806SA-0080
GARD PT battery charging kit
803XA-0020
LED strip (Boom L = 4050)
803XA-0150
LED strip (Boom L = 3050)
803XA-0160
LED strip (Boom L = 2000)
803XA-0040
Detachable boom-supporting assembly
p. 6 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
9 9
p. 7 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Standard installation
Barrier
Reflective strips
LED strip
Anti-collision profile
Luminous gearwheel
Photocell
Small photocell post
Fixed rest
Coil
Control device post
Control device (keypad selector, transponder sensor)
p. 7 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
200
70
160
240
Ø 80
Ø 12,5
500
340
400
p. 8 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Cable types and minimum thicknesses
Connection
Cable length
1 < 15 m
Cable length
15 < 30 m
Power-supply at 230 V AC
3G x 1.5 mm
2
3G x 2.5 mm
2
Photocell transmitters 2 x 0.5 mm
2
Photocell receivers 4 x 0.5 mm
2
Command and safety device 2 x 0.5 mm
2
Antenna max 10 m
Paired or CRP (Came Remote Protocol) connection max 1,000 m (*)
Metal mass detector (see product literature)
(*) 1000 m with 001UR042; 1000 m with 001RGSM001, 001RGSM001S, 001RSLV001 (Cloud connectivity devices). With a 230V AC power
supply and using it outdoors, use H05RN-F type cables compliant with 60245 IEC 57 (IEC); whereas indoors, use H05VV-F-type cables that are
60227 IEC 53 (IEC) compliant.
To connect to the CRP, use UTP CAT5-type cables up to 1,000 m in length.
Use RG58 cable up to 10 m long to connect the antenna.
If cable lengths di er from those specifi ed in the table, establish the cable sections depending on the actual power draw of the connected
devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. For connecting products that are not contemplated in this manual, see the literature accompanying said products
INSTALLING
The following illustrations are mere examples. Consider that the space available where to fit the barrier and accessories will vary depending on
the area where it is installed. It is up to the installer to find the most suitable solution.
Preparing the fastening plate.
If the flooring does not allow for a sturdy fastening of the entry unit, you will have to set up a cement slab.
Dig a hole for the foundation frame.
Set up the corrugated tubes needed for the wiring coming out of the junction pit.
The number of tubes depends on the type of system and the accessories you are going to fit.
p. 8 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
p. 9 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Set up a foundation frame that is larger than the anchoring plate and sink it into the dug hole.
Fit an iron cage into the foundation frame to reinforce the concrete.
Assemble the four anchoring braces to the anchoring plate.
Place the plate over the iron cage.
Fill the foundation frame with concrete. The base must be perfectly level with the bolts which are entirely above surface.
Wait at least 24 hrs for the concrete to solidify.
Remove the foundation frame.
Fill the hole with earth around the concrete block.
Remove the nut and washer from the bolts
Fit the electrical cables into the tubes until they come out at the necessary lenght
p. 9 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
p
ESC < > ENTER
n
o
p. 10 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Preparing the barrier
- Fit the key into the lock and turn it counter clockwise .
- Raise the cover and disconnect the two earthing cables .
- Removethe inspection hatch .
The barrier is set up for installing on the left.
When installing on the right, invert the boom's opening direction,
as follows:
Check that the lever arm is in vertical position, as shown in
the drawing.
Remove the mechanical stop by using an Allen wrench.
Fasten the mechanical stop as shown in the drawing .
Change the parameter of function F54 (invert direction of
travel).
Left
Right
p. 10 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
UNI5931 M8x20
p. 11 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Fasten the fastening flange to the motor shaft plate by using a supplied UNI5931 M8X20 screw and .
Insert the 803XA-0110 supplied as standard. .
Installing the barrier
The cabinet should be installed with the inspection hatch on the most accessible side to make any adjusting easier.
Place the cabinet onto the anchoring plate and fasten it using nuts and washers.
p. 11 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
p. 12 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Fit the boom into the fastening flange and fasten it using the screws .
Cut the groove covering frame to the right length and fit them into the boom grooves on either side .
Fit the rubber terminal cap into the corresponding housing .
Fit the anti-collision profile into the boom , to match the terminal cap .
Cut the excess part of the profile, while leaving a bit protruding .
Fit the terminal cap into the boom end cap; Then fasten it to the boom by tightening the corresponding screws .
Fit the anti-shearing protective cover onto the boom-attachment cover and fasten it using the screws .
p. 12 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
+
-
~1°
~89°
+
-
+
-
~1°
~89°
+
-
p. 13 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Establishing the limit-switch points
Close the inspection hatch and power up the system. Actuate the boom to check that it is parallel to the road surface when in the closed position
when in the closed position, and at about 89° when in the open position.
To correct the boom's vertical position:
- Lower the boom;
- Open the inspection hatch;
- Loosen the nut and adjust the limit-switch by turning the screw ;- Tighten the previously loosened nut .
To adjust the bar’s horizontal position:
- Lower the bar;
- Open the inspection hatch;
- Loosen the nut and adjust the limit-switch by turning the screw ;- Tighten the previously loosened nut .
p. 13 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
p. 14 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Composition of the semi-oval boom
Before adjusting the boom, check the accessories you want to fit and the passage clearance width.
The 001G02807 fixed rest MUST be used with passage widths exceeding 3 m.
PASSAGE CLEARANCE WIDTH (3.8 m max.)
By bar we mean a bar fi tted with anti-collision profi le, groove cover and end cap.
CONTROL PANEL
Caution! Before working on the control panel, cut off the mains power supply and remove any batteries.
Control panel power supply 230 V AC.
Functions on input and output contacts and time and user management details, are set up and viewable on the control panel's display.
FUSE TABLE ZLB30
Line fuse 3.15 A - Fast
Power board fuse 3.15 A - Fast
Accessories fuse 2 A - Fast
Motor fuse 15 A - Fast
A1=1 (Fast pro le – opening time 1.2-2.5 seconds)
Working intermittency
80% 100%
Bar length
< 2,5m from 2.5m to 2.75m
Bar
Bar with LED strip
Spring
A1=2 (Slow profi le – opening time 2.5-4 seconds)
Working intermittency
100%
Bar
Bar with LED strip
Spring
p. 14 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
EB EB
ARM
TAMPER
FCA CM1 FCC CM2
24 0 30 0
10 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
p. 15 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Power supply terminal board
Terminals for control and safety devices
Barrier state (NO) terminals.
Terminal block for signalling devices: LED strip, luminous
gearwheel and door opening safety contact
Terminal board for transponder selector
Terminal board for keypad devices
Terminal board for either paired / alternate connection
CRP connection terminals
Connector for the RSE card (F49)
AF card connector
R700/R800 card connector
USB stick connector
Encoder connector
Motor connector
Display
Programming buttons
RSE card connector (paired or alternate).
Electric lock
Terminals for input of NC contact for boom drop away
Terminal for NC contact for cover
Terminals for input of NC contact for electric lock release
Antenna terminal
Description of parts
p. 15 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
TS 1 2 3 3P 4 5 7 2 CX CY CZ
p. 16 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Input voltage
- a 24 V AC normally;
- at 24 V DC when the emergency operation batteries start
operating.
Maximum absorption of all the devices is max. 40 W
Accessories terminals:
ELECTRICAL CONNECTIONS
Command and control devices
Control device for CLOSE (NO contact) function.
In MAINTAINED ACTION mode you must connect the control device
onto 2-4.
TEMPORARY STOP button (NC contact).
It blocks the boom for 15 seconds, and then opens and excludes the
automatic opening. To resume movement, activate any control device.
If unused, set to OFF (Deactivated) from the F1 function.
Control device for the OPEN-CLOSE-INVERT function (NO contact).
Control device for the OPEN (SLAVE barrier) function (NO contact)
for paired or alternate mode barriers (see corresponding chapter).
Control device for the OPEN (NO contact).
In MAINTAINED ACTION mode you must connect the control
device onto 2-3.
Keypad selector
Transponder or card reader
230 V AC
50/60 Hz
N PE L
p. 16 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
AF
R700
R800
CO
M
C
EB EB
CAM
E
RGB
10 11 E1 E6 TS 1 2 3 3P 4 5 7
p. 17 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
AF - for radio-control of the operators.
RSE - for CRP (see corresponding chapters).
RSE - for installations with paired and alternate barriers (see corresponding
chapters).
Connector for the R700 card (for using the transponder or the card reader) or for
the R800 card (for using the keypad selector).
Additional cards
For the system to work properly, before fi tting any plug-in card, such as the AF or
R800 one, you MUST CUT OFF THE MAINS POWER SUPPLY and, if present, disconnect
any batteries.
R800
max. number of devices
SELT1NDG
SELT2NDG
2
R700
max. number of devices
SELR1NDG
SELR2NDG
1
Signaling devices
Barrier warning light (Max 3W).
It warns about the state of the barrier, see function F 10.
Additional flashing light.
It flashes when the barrier is opening and closing, see
function F18 = 0 (default).
Contacts rated for 24 V DC max.
10 - E1 10 - 5
20 W 3 W
Fixed, additional, outdoor light.
During the ACTIVE CYCLE function it stays on from
the moment in which the boom starts opening to the
moment it completely closes (including the automation
closing time). see function F 18 = 1.
LED strip and/or luminous gearwheel (max 13.5 W)
Flashes red when the barrier is moving and during the
pre-flashing phase.
Steady red when the barrier is closed.
Steady green when the barrier is open.
p. 17 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
10 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
10 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
10 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
10 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
p. 18 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
Safety devices
For the type of action controlled by the device,see function F2 for terminal CX, F3 for terminal CY or F4 for terminal CZ.
If unused, contacts CX, CY and CZ should be disabled during programming.
Photocells
Configure contact CX, CY and/or CZ (NC/NO), input for safety devices such as photocells.
- C1 reopening while closing (NC). During closing, opening the contact causes the movement to invert until the barrier is completely open;
- C4 obstruction wait NC. Movement resumes after the obstruction is removed.
- C5 immediate closing (NC) with barrier completely open. The boom closes after a vehicle has passed through the operating area of the safety
devices.
- C9 immediate closing with obstruction wait when closing (NC). The boom closes after a vehicle has passed through the operating area of the
safety devices. During the closing phase, the devices also perform the obstruction wait function.
- C10 immediate closing during an opening maneuver with obstruction wait during the closing phase (NO). Boom closes after vehicles passes
through the area protected by the safety devices. During the closing phase, the devices also perform the obstruction wait function.
CONNECTION WITH SAFETY TEST (see function 5)
Photocells
DIR / DELTA-S
- receiving - transmitting
Photocells
DELTA
- receiving - transmitting
STANDARD CONNECTION
Photocells
DIR / DELTA-S
- receiving - transmitting
Photocells
DELTA
- receiving - transmitting
p. 18 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
USB
USB
p. 19 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
- Fit the USB stick. Enter the card's menu. The red LED lights up when the USB memory stick is recognized.
Functions F50, F51 and H2 are now visible.
- Fit the USB to save / copy the settings and users, select F50 or F51.
- To update the fi rmware select H2.
) In the USB stick, you can store the user data and the system confi guration on a PC.
SAVING AND UPLOADING USER AND CONFIGURATION DATA and updating firmware
PROGRAMMING DEVICE -
Description of programming commands
The key is for:
entering the programming mode;
entering the single menus;
confirming/saving the values you have set
The keys <> are for:
moving from one item to another;
- increasing or decreasing a value.
The < close
key The > open key
This key is
for exiting the menus without saving any
changes
Display for viewing functions
and settings that are assigned
via the programming buttons.
After 10 seconds
without pressing any
button, the single
programmings end with no
consequences .
p. 19 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
p. 20 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - This is a translation of the original instructions
F 1 Temporary stop function (1-2)
F 2 Function associated to input CX
F 3 Function associated to input CY
F 4 Function associated to input CZ
F 5 Safety test function
F 6 Maintained action function
F 9 Obstruction detection with motor idle function
F 10 Warning light function
F 14 Sensor type selection function
F 17 Electric lock function
F 18 Additional light function
F 19 Automatic closing time
F 21 Preflashing time
F 28 Adjusting opening speed
F 29 Adjusting closing speed
F 34 Sensitivity during movement
F 49 Enabling serial connections
F 50 Saving data in the USB memory stick
F 51 Reading data on the USB memory stick
F 52 Copying parameters from Master to Slave
F 54 Selecting direction function
F 56 Peripheral number
F 63 Changing COM speed
F 70 Function associated to the limit-switch outputs configuration
F 75 Open command counter function
F 78 Function associated to boom drop-away ARM input
U 1 Type of command to associate to a user via radio control
U 2 Deleting single users
U 3 Deleting all users
U 4 Decoding the code
A 1 Setting the boom type
A 2 Motor test
A 3 Travel calibration
A 4 Resetting parameters
A 5 counting the number of maneuvers
H 1 Software version
H 2 Firmware updates
Start programming by first performing the following functions
SETTING THE BOOM TYPE (A1), TEMPORARY STOP (F1), CALIBRATE TRAVEL (A3).
Only program functions when the operator is stopped.
Up to 250 users can be memorized.
Menu map
F1 Temporary stop [1-2] OFF = Deactivated (default) / ON = Activated
NC input - Temporary stop of the barrier with exclusion of any automatic closing; once 15 seconds have elapsed it slowly opens.
F2 Input [2-CX] OFF = Deactivated (default) / C1 / C4 / C5 /C9 /C10/r7
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate closing
with obstruction wait when closing, C10 (NO input) = immediate closing even during maneuver with obstruction wait during closing, r7 8K2 resistive
safety edge = immediate reopening after closing.
F3 Input [2-CY] OFF = Deactivated (default) / C1 / C4 / C5 /C9 / C10/r7
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate closing
with obstruction wait when closing, C10 (NO input) = immediate closing even during maneuver with obstruction wait during closing, r7 8K2 resistive
safety edge = immediate reopening after closing.
F4 Input [2-CZ] OFF = Deactivated (default) / C1 / C4 / C5 /C9 / C10/r7
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate closing
with obstruction wait when closing, C10 (NO input) = immediate closing even during maneuver with obstruction wait during closing, r7 8K2 resistive
safety edge = immediate reopening after closing.
F5 Safety test OFF = Deactivated (default) / 1 = CX / 2 = CY / 3 = CZ / 4 = CX+CY / 5 = CX + CZ /
6 = CY+CZ / 7 = CX+CY+CZ
After every opening or closing command, the board will check whether the photocells are working properly.
The safety test is always active for wireless devices.
F6 Maintained action OFF = Deactivated (default) / ON = Activated
The barrier opens and closes when a button is kept pressed: it opens by keeping pressed 2-3 and closes by keeping pressed 2-4. All other control
devices, even radio-based ones, are excluded.
p. 20 - Manual FA01119-EN- 10/2018 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28