Installation & safety precautions (EN 60335 Standards)
Before switching on the product, please read the “Installation & Safety Precautions” in detail rst to
ensure the correct operation of the product.
Installation precautions
The product is designed for household or residential use. You are advised to have the product installed
by an authorized professional installer. Make sure the product is properly connected to 230V.
ATTENTION
Children under 3 years of age should be kept out of reach of the appliance
unless continuously supervised. Children from the age of 3 years to 8
years should only switch the appliance on/off when it has been placed
or installed in its normal intended use position and when they have been
given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children from 3 years of age to
8 years of age should not plug in, adjust or clean the appliance or carry out
maintenance operations.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical sensory or mental capabilities or lack
of experience and knowledge if they are supervised or have been given
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children should not play with the appliance. Cleaning
and user maintenance should not be carried out by children without
supervision. Children must be supervised at all times to ensure that they
do not interfere with the product.
This product is lled with a precise amount of special oil that does not
need any maintenance. Any repairs requiring the opening of the oil tank
must only be done by an ofcial Rointe installer or its after-sales service
personnel, who should also be notied should an oil leak be noticed. The
regulations on discarding oil when the heater is being disposed of must be
observed.
Do not cut the power supply cable under any circumstances in order to
avoid electrical risks and to guarantee the correct operation of the towel
rail.
Do not switch on the product if you notice any external damage when
unpacking or installing the towel rail. If the power cable is damaged, it
must be replaced by the manufacturer, its after-sales service or authorized
personnel in order to avoid any damage.
3
GIZA DIGITAL
EN
Do not spray or wet the product. During operation, keep the product away
from combustible materials such as curtains, furniture, etc. Do not place
anything other than clothes, towels or non-ammable fabrics on the product.
The towel rail must be installed in such a way that the power plug is always
accessible. The power cable must never be in contact with the product
during operation.
CAUTION - Never touch the product with wet hands or any wet
body parts.
CAUTION - Some parts of this product may become very hot
and cause burns. Particular care should be taken when children
and vulnerable persons are present.
Contents
1. Rointe towel rails technical specications .............................................................................................4
2. Rointe towel rails installation........ ...........................................................................................................8
2.1. Mounting ..........................................................................................................................................8
2.2. Fixing the supports .........................................................................................................................9
2.3. Connecting instructions .................................................................................................................9
3. Rointe towel rails information & instructions..........................................................................................10
3.1. Keypad .............................................................................................................................................10
3.2. Screen ..............................................................................................................................................10
3.3. Switch on & off (stand-by) ..............................................................................................................11
3.4. Adjust the day & time ......................................................................................................................11
3.5. Lock the keypad...............................................................................................................................12
3.6. Select either MANUAL or AUTOMATIC mode.............................................................................12
3.7. Rointe towel rails advanced functions..................................................................................................15
4. Maintenance & cleaning............... .........................................................................................................16
5. Guarantee......................................... ......................................................................................................17
6. How to register your guarantee....... .......................................................................................................19
7. ERP Directive (EU) 2015/1188....... ..........................................................................................................20
4
1. Technical specifications (Models 400, 450, 500 & 550)
MODEL - Width 400
WHITE
TGIL*40B080 TGIL*40B120 TGIL*40B160 TGIL*40B180
CHROME
TGIL*40C080 TGIL*40C120 TGIL*40C160 TGIL*40C180
DIMENSIONS
Width (mm) 400 400 400 400
Height without control panel (mm) 800 1,200 1,600 1,800
Height with control panel (mm) 880 1,280 1,680 1,880
Depth (mm) 30 30 30 30
Installed depth (mm) 100 100 100 100
MECHANICAL CHARACTERISTICS
Stainless steel heating element
Thermal fluid
Digital control panel
LCD screen
Finish
White RAL 9016
Chrome
ELECTRICAL CHARACTERISTICS
Nominal power (W)
White 300 500 750 1,000
Chrome 300 300 500 750
Voltage (V) 230 V ~ 230 V ~ 230 V ~ 230 V ~
Current (A)
White 1.3 2.2 3.3 4.4
Chrome 1.3 1.3 2.2 3.3
Class II
SAFETY & INSTALLATION
Installation kit included
Safety thermostat
Fireproof wiring
Protection grade IP 44 IP 44 IP 44 IP 44
5
GIZA DIGITAL
EN
MODEL - Width 450
WHITE
TGIL*45B080 TGIL*45B120 TGIL*45B160 TGIL*45B180
CHROME
TGIL*45C080 TGIL*45C120 TGIL*45C160 TGIL*45C180
DIMENSIONS
Width (mm) 450 450 450 450
Height without control panel (mm) 800 1,200 1,600 1,800
Height with control panel (mm) 880 1,280 1,680 1,880
Depth (mm) 30 30 30 30
Installed depth (mm) 100 100 100 100
MECHANICAL CHARACTERISTICS
Stainless steel heating element
Thermal fluid
Digital control panel
LCD screen
Finish
White RAL 9016
Chrome
ELECTRICAL CHARACTERISTICS
Nominal power (W)
White 300 500 750 1,000
Chrome 300 300 500 750
Voltage (V) 230 V ~ 230 V ~ 230 V ~ 230 V ~
Current (A)
White 1.3 2.2 3.3 4.4
Chrome 1.3 1.3 2.2 3.3
Class II
SAFETY & INSTALLATION
Installation kit included
Safety thermostat
Fireproof wiring
Protection grade IP 44 IP 44 IP 44 IP 44
6
MODEL - Width 500
WHITE
TGIL*50B077 TGIL*50B112 TGIL*50B150 TGIL*50B172
CHROME
TGIL*50C077 TGIL*50C112 TGIL*50C150 TGIL*50C172
DIMENSIONS
Width (mm) 500 500 500 500
Height without control panel (mm) 800 1,200 1,600 1,800
Height with control panel (mm) 880 1,280 1,680 1,880
Depth (mm) 30 30 30 30
Installed depth (mm) 100 100 100 100
MECHANICAL CHARACTERISTICS
Stainless steel heating element
Thermal fluid
Digital control panel
LCD screen
Finish
White RAL 9016
Chrome
ELECTRICAL CHARACTERISTICS
Nominal power (W)
White 300 500 750 1,000
Chrome 300 300 500 750
Voltage (V) 230 V ~ 230 V ~ 230 V ~ 230 V ~
Current (A)
White 1.3 2.2 3.3 4.4
Chrome 1.3 1.3 2.2 3.3
Class II
SAFETY & INSTALLATION
Installation kit included
Safety thermostat
Fireproof wiring
Protection grade IP 44 IP 44 IP 44 IP 44
7
GIZA DIGITAL
EN
MODEL - Width 550
WHITE
TGIL*55B077 TGIL*55B112 TGIL*55B155 TGIL*55B172
CHROME
TGIL*55C077 TGIL*55C112 TGIL*55C155 TGIL*55C172
DIMENSIONS
Width (mm) 550 550 550 550
Height without control panel (mm) 800 1,200 1,600 1,800
Height with control panel (mm) 880 1,280 1,680 1,880
Depth (mm) 30 30 30 30
Installed depth (mm) 100 100 100 100
MECHANICAL CHARACTERISTICS
Stainless steel heating element
Thermal fluid
Digital control panel
LCD screen
Finish
White RAL 9016
Chrome
ELECTRICAL CHARACTERISTICS
Nominal power (W)
White 300 500 750 1,000
Chrome 300 300 500 750
Voltage (V) 230 V ~ 230 V ~ 230 V ~ 230 V ~
Current (A)
White 1.3 2.2 3.3 4.4
Chrome 1.3 1.3 2.2 3.3
Class II
SAFETY & INSTALLATION
Installation kit included
Safety thermostat
Fireproof wiring
Protection grade IP 44 IP 44 IP 44 IP 44
8
2. Rointe towel rails installation
2.1. Mounting instructions
Inside the packaging you will nd a xing kit. Please nd the instructions below:
1. Choose the right part of the wall.
2. Place the mounting stencil on the wall, marking the places for the holes.
3. Remove the stencil and make the holes in the wall.
4. Insert the rawl plugs in the holes made.
5. Screw the plastic fastener to the wall with the 5.5 x 50 mm screw.
6. Screw the two brackets for supporting the product and the plastic fastener to the horizontal tube
of the product like in Figure 1 with the 8 x 26 mm screw.
7. Insert what you have assembled in Section 6 into the plastic piece. Fix well with the 5 x 12 mm screw.
8. Place the cover on the piece supporting the product.
NO. ELEMENT
1 10 x 40 mm Rawl Plug
2 Bracket
3 5.5 x 50 mm Screw
4 5 x 12 mm Screw
5 Bracket Insert
6 Bracket Head
7 8 x 26 mm Screw
8 Cap
9 Product
2.2. Connecting instructions
Connection to the mains must be made observing the voltage stated on the product technical data label.
This product is designed to be permanently installed connected to xed facilities. The product power
supply circuit must have an all-pole circuit breaker switch with a separation of at least 3 mm between
the contacts. The product must be installed, if possible, away from any source of draughts (windows,
doors) or any other thing which may affect its functioning. In this way, the temperature will not be
affected. Place any object which might prevent the air ow (furniture, armchairs) 50 cm away from the
front of the product.The product must never be installed immediately below a power point. The lower
part of the control panel must be placed at least 15 cm from the oor.
For any product, if the power cable is damaged, it must be replaced by a specic cable. The replacement
of the cable must be done by the maker, its after-sales service or qualied personnel. The technical
specications of your product appear on the technical data label.
1
5
9
GIZA DIGITAL
EN
OK
IMPORTANT - This product must never be installed with its control
panel at the top. This product must not be installed horizontally. During
installation, use wedges so that the control panel will not be in contact
with the floor.
2.3. Specific regulations for bathrooms
This product is classied as CLASS II and can be safety installed in Zones 3. For installations in Zones 2
(check the scheme below), please consider the following limitations:
In bathrooms, the product must never be installed in such a way that the control panel may be touched by
someone in the bathtub or having a shower. The control panel should be located at least 600 mm distance from
any wet areas. The body of the product can be placed in Zones 2 if the control panel is located inside Zone 3.
In a kitchen or bathroom, the body of the product must be placed at least 25 cm from the oor.
10
3. Rointe towel rails information & instructions
3.1. Keypad
Settings / Back
Decrease temperature / Move down
On/Off (stand-by) / Conrm
Increase temperature / Move up
MANUAL / AUTO function
3.2. Screen
1 Programming - Hours of the Day available
2 Programming - Hours of the Day selected
3 Days of the Week
4 Energy Consumption indicator
5 SET TIME setting indicator
6 Current time/temperature
7 Keypad Locked indicator
8 Heating element on indicator
9 COMFORT / ECO / ANTI-FROST mode indicator
10 OPEN WINDOWS
11 Pre-installed programmes indicator
12 MANUAL/PILOT* function indicator
(*Not available)
13 Programming - COMFORT / ECO indicator
14 2 Hour Boost mode indicator
Keypad locked
Heating element on
ANTI-FROST mode on
ECO mode on
COMFORT mode on
OPEN WINDOWS function on
Pre-installed programme active
MANUAL function active
PILOT function active (Not available)
2 Hour Boost mode active
11
GIZA DIGITAL
EN
3.3. Switch on & off (stand-by)
To switch the product on, please press the button once. To switch the product off, please press
the button again. When you switch the product on for the rst time you will be prompted to set the
day and time. Use the buttons to select the correct hour and press the button to conrm.
Next use the
buttons to select the correct minute and press the button to conrm. Then
use the buttons to select the correct day and press the button to conrm.
3.4. Adjust the day & time
To adjust the day or time of the product, please press the button to access the Settings Menu.
Then you will need to use the buttons to scroll to the menu on the screen and press
the button to conrm.
Use the
buttons to select the correct hour and press the button to conrm. Next use the
buttons to select the correct minute and press the button to conrm. Then use the
buttons to select the correct day and press the button to conrm.
3.5. Lock the keypad
To lock the keypad, please press and hold the buttons at the same time for 3 seconds. A
icon will appear at the top of the screen.
To unlock the keypad, press and hold the
buttons again at the same time for 3 seconds. The
icon will disappear from the top of the screen.
3.6. Select either the MANUAL, AUTOMATIC or PILOT mode*
(*only upon demand)
To select either the MANUAL, PILOT and AUTO, AUTO 1, AUTO 2, AUTO 3 and AUTO 4 modes you
need to press the button and keep pressing until the mode you want is highlighted.
On the display panel, the
icon will appear when you are in one of the AUTO modes (1-4), the
icon will appear when you are in MANUAL mode and the icon will appear when in PILOT mode
(not available).
12
00 01 02 03 04 05 06 07 08 09 10 11
AM
3.6.1. MANUAL mode
When MANUAL mode is selected the set temperature, MANUAL mode icon, COMFORT/ECO/AN-
TI-FROST icon and the time/day of the week will be displayed on the screen. The set temperature
and the hour will alternate every 5 seconds on the screen.
In MANUAL mode you can choose a set temperature and the corresponding COMFORT/ECO/AN-
TI-FROST icon will appear on the screen according to the ranges below:
COMFORT
21 - 30
o
C
ECO
7.5 – 20.5
o
C
ANTI-FROST
7
o
C
To adjust the set temperature:
Use the
buttons to either increase or decrease the temperature respectively. When you
choose a temperature in the table above, the corresponding icon will appear on the screen.
When the room temperature is lower than the set temperature on the display panel, the product will
display the
symbol in the top right of the screen.
3.6.2 AUTOMATIC mode
When the AUTOMATIC mode is selected, this activates the programming already established in the
product. You can choose from one of the 4 pre-installed programmes within the Rointe product:
Auto 1 Auto 2 Auto 3 Auto 4
You can also modify these pre-installed programmes to suit your needs. Please check the following
pages for a step by step guide on how to activate or modify one of the pre-installed programmes.
13
GIZA DIGITAL
EN
AUTO pre-installed programme scheduling
PREPROGRAM 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mon-
Fri
Sat-
Sun
PREPROGRAM 2
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mon-
Fri
Sat-
Sun
PREPROGRAM 3
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mon-
Sun
PREPROGRAM 4
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mon-
Fri
Sat-
Sun
To activate one of the pre-installed programmes:
Press the
button on the keypad until either AUTO, AUTO 1, AUTO 2, AUTO 3 or AUTO 4 is high-
lighted. The pre-installed programme will now be active and the corresponding icon will appear on
the screen.
1
A
00 01 02 03 04 05 06 07 08 09 10 11
AM
To modify one of the pre-installed programmes:
STEP 1 - You will need to establish the set temperature of the COMFORT/ECO/ANTI-FROST modes
rst. Please press the
button to access the Settings Menu. Then you will need to use the
buttons to scroll between the menus to select the menu on the screen and press the
button to conrm.
The COMFORT temperature is adjusted rst. Press the
buttons to either increase or decrease
the temperature respectively within the pre-set COMFORT temperature range (see table above).
Press the button to conrm and you will then move to the ECO temperature settings. Use
the buttons to either increase or decrease the temperature respectively within the pre-set
ECO temperature range. Press the button to conrm and you will then move to the ANTI-FROST
COMFORT ECO OFF
14
temperature settings. Use the buttons to either increase or decrease the temperature
respectively and press the button to conrm.
STEP 2 - Press the button on the keypad until the programme that you wish to modify (AUTO 1,
AUTO 2, AUTO 3 or AUTO 4) is highlighted. The pre-installed programme will now be active and the
corresponding icon will appear on the screen.
STEP 3 - Press AND hold the
button on the keypad for 2 seconds to modify the hours and days.
The days can be modied rst. Use the buttons to select the chosen days and press the
button to select the days you want to modify.
1
A
STEP 4 - Then you will move onto setting the mode for each hour, of the day which will begin at 0h
(midnight).
You will need to go through each hour and select a mode for each hour. Select the mode by press-
ing the
button - press once for COMFORT, press twice for ECO and press three times for AN-
TI-FROST. To move onto the next hour, use the buttons.
NO-FROST ECO COMFORT
Once all 24 hours of the day have been assigned a mode, press the button to save your settings
and return to the main screen.
3.7. Rointe towel rails advanced functions
3.7.1. OPEN WINDOWS function
The Rointe towel rails have the OPEN WINDOWS function set to ON to begin with. This function
is activated when the temperature sensor detects a drop of 4ºC from the set temperature within a 30
minute time period.
15
GIZA DIGITAL
EN
The OPEN WINDOWS function will be active for 2 hours. When the OPEN WINDOWS function is ac-
tivated, the product will move into ANTI-FROST mode at 7ºC. To activate or deactivate this function,
please press the button to access the Settings Menu.
Then you will need to use the
buttons to select the OPEN WINDOWS. Once selected, press
the button and use the buttons to activate or deactivate this function.
The function PRESENCE DETECT (ALSO DISPLAYED IN THIS MENU) is not available on the
product.
3.7.3. Energy consumption indicator
Rointe towel rails have a unique energy consumption indicator so you can monitor your energy ex-
penditure. The
icon will appear down the left side of the screen when switched on to indicate the
expenditure level.
M
24.5 - 30ºC 19 - 24ºC < 19ºC
Within this temperature range,
you are using a high amount of
energy.
Within this temperature range,
you are using an average/me-
dium amount of energy.
Within this temperature range,
you are using a low amount of
energy
3.7.4. 2 HOUR BOOST function
This product has a unique two hour BOOST mode that will override any other set mode and will boost
your product to maximum power. You can choose to boost to maximum power for 15 minutes, 30
minutes, 1 hour or 2 hours.To activate, press and hold the button for 2 seconds. Use the
buttons to select either 15 minutes, 30 minutes, 1 hour or 2 hour boost and conrm by pressing the
button. To deactivate, please press the button again once.
4. Maintenance & cleaning
The product does not require any type of maintenance. We recommend that all parts of the product
are kept clean (behind, underneath, upper ns, etc.). Do not use any abrasive product on the steel
main body. Clean it with a damp cloth and a pH neutral soap, and the control panel with a dry cloth.
European Directive 2012/19/UE
Under the European Directive 2012/19/UE on waste electrical and electronic equipment (WEEE), the
product cannot be disposed in the usual council bins and containers. They must be separated to
16
optimize the recovery and recycling of all of the components and materials and reducing the impact
to human health and the environment. The symbol of the container crossed out over a horizontal
line is marked on all of Rointe products to remind the consumer of the obligation to separate them
on disposal. The consumer should contact the local authority or original point of sale to learn more
about the correct disposal of this product.
5. Guarantee
In this section, we hereby describe the guarantee conditions which the buyer acquires on buying a
new Rointe product. These conditions comply with all the rights construed in the national legislation
in force, as well as any additional rights and guarantees which are offered by Rointe.
5.1. Any incident that you might detect in your Rointe product can be sorted by the product seller or
quickly by the manufacturer. Please contact Rointe by telephoning (UK) 0203 321 5929 or (Ireland)
01 553 0523 for technical support. If you live in a different country, please check the correct phone
number on the back of this manual.
GIZA 500 300W
TELLN45B077
300 W
You will need to state the product reference (located on the label indicating product features), serial
number, proof of purchase and the type of incident at hand when contacting us so that we can check
the guarantee. In addition, please attach a copy of the product invoice.
5.2. Rointe guarantees that there are no material defects of design or manufacture at the time of
original acquisition and guarantees the steel main body for a period of 120 months and 24 months for
any electronic and electrical components.
5.3. If during the guarantee period, the product does not work correctly under normal use, and any
design, material or manufacturing defect is found, Rointe will repair or substitute the product as it
may see t, in accordance with the terms and conditions as follows:
5.3.1. The guarantee is only applicable if the original guarantee is issued by the seller and when
the said guarantee is lled in correctly including product reference, series number (marked on the
product’s label indicating technical features), purchase date and the seller’s stamp.
Rointe reserves the right to reject the guarantee service when this information has been removed or
modied after the original product purchase.
5.3.2. The guarantee only applies to those cases that concern material, design and manufacturing
defects, and under no circumstances covers damage to the product for the following reasons:
5.3.2.1 Incorrect use of the product, i.e. used for other purposes that are not construed as its
normal use or for not respecting the instructions of use and maintenance given by Rointe as well as
incorrect installation or use of the product that may not comply with the current technical standards
17
GIZA DIGITAL
EN
of safety.
Corrosion caused by direct exposure to salt water is excluded from the guarantee. When the product
is installed no more than 200m from the coast the guarantee for damages caused by corrosion the
period will be reduced by 50%.
5.3.2.2 Any unauthorized repairs carried out by unauthorized technicians or opening of the
product by unauthorized people.
5.3.2.3 Any accidents that are deemed outside the control of Rointe, such as lightning, res,
oods, public disorders, etc.
5.3.3. Any repairs or substitutions that are included in this guarantee do not allow any additions
or new periods of guarantee.
5.3.4. Any repairs or substitutions covered under this guarantee must be parts that are functional-
ly equivalent. The defective parts or parts removed or replaced shall become the property of Rointe.
5.4. The technical service of Rointe will advise you if you need to buy any parts not covered under
the guarantee or out of guarantee.
5.5. This guarantee does not affect the buyer’s legal rights stipulated in the current national legisla-
tion, nor affects those rights against the distributor or installer that could come forth in compliance
with the purchase contract.
5.6. In the absence of a national legal legislation applicable, this guarantee shall prevail and may be
construed as the buyer’s only protection. Rointe, its ofces, distributors and installers may not be
held responsible for any accidental damage that emerges due to infringement of any rules implicitly
related to this product.
18
6. How to register your product guarantee
IMPORTANT: It’s important to register your ROINTE product as part of our guarantee service, in
case you wish to make a claim.
You can register your ROINTE product in the following ways:
WEBSITE
1. Go to www.rointe.com/uk/register-your-guarantee/.
2. Login to your existing account or create a new account if you need to.
3. Click on “My products”.
4. Enter your product reference (alphanumeric and in upper case).
5. Enter your serial number (26 digits located on the metal tag on your product and starts with 843).
6. Upload your proof of purchase, such as invoice in PDF, JPEG or PNG format. This is not
mandatory but by doing so you ensure your guarantee period is accurate.
7. Click “Register”.
8. Congratulations! Your product is now registered.
EMAIL
1. Send an email to support@rointe.co.uk with the following information:
Customer name
Address and postcode
Telephone number and email address
Product reference (as described above)
Serial number (as described above)
Product purchase date and proof of purchase (as described above).
2. Our Technical Support team will conrm your product registration and request any additional
information needed via email.
POST
1. Post the information listed in the EMAIL section above to:
INDUSTRIAS ROYAL TERMIC, S.L. t/a Rointe UK, C/E Parcela 43, 30140,
Santomera (SPAIN)
2. Please ensure you obtain proof of posting.
19
GIZA DIGITAL
EN
20
7. ERP DIRECTIVE (EU) 2015/1188
ITEM
White
SYMBOL UNIT
TGIL***B077 TGIL***B112 TGIL***B150 TGIL***B172
Chrome TGIL***C077 TGIL***C112 TGIL***C150 TGIL***C172
HEAT OUTPUT
Nominal heat output
White
P
nom kW 0.30 0.50 0.75 1.00
Chrome
P
nom kW 0.30 0.30 0.50 0.75
Minimal heat output
P
min kW n/a n/a n/a n/a
Maximum continuous heat output
White
P
max,c kW 0.30 0.50 0.75 1.00
Chrome
P
max,c kW 0.30 0.30 0.50 0.75
AUXILIARY ELECTRICITY CONSUMPTION
At nominal heat output
White
el
MAX kW 0.30 0.50 0.75 1.00
Chrome
el
MAX kW 0.30 0.30 0.50 0.75
At minimum heat output
White
el
MIN kW 0.30 0.50 0.75 1.00
Chrome
el
MIN kW 0.30 0.30 0.50 0.75
In standby mode
el
SB kW 0.002 0.002 0.002 0.002
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Rointe Giza Digital Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI