Chauvet HIVE Reference guide

Category
Floodlights
Type
Reference guide
Quick Reference Guide
HIVE™ QRG EN
2
About This
Guide
The HIVE™
Quick Reference Guide (QRG) has basic product information
such as mounting, menu options, and DMX values. Download the User
Manual from www.chauvetlighting.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to
change without notice.
Safety Notes
These Safety Notes include important information about installation, use,
and maintenance.
This product is not intended for permanent installation.
ONLY connect this product to a grounded and protected circuit.
Always disconnect from power before cleaning or replacing the fuse.
DO NOT look at the light source when the product is on.
Make sure the power cord is not crimped or damaged.
Never disconnect this product from power by pulling on the cord.
When mounting this product overhead, use a safety cable.
DO NOT allow flammable materials close to the unit while operating.
DO NOT touch this product when it is operating because it may be hot.
The voltage of the outlet to which you are connecting this product must
be within the range stated on the decal or rear panel of the product.
This product is for indoor use only! (IP20) To prevent risk of fire or
shock, do not expose this product to rain or moisture.
Always mount this product in a location with adequate ventilation, at
least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Never connect this product to a dimmer or rheostat.
Replace the fuse with one of the same type and rating.
ONLY use the hanging/mounting bracket to carry this product.
The maximum ambient temperature is 104° F (40° C). Do not operate
this product at higher temperatures.
In the event of a serious operating problem, stop using immediately.
DO NOT open this product. It contains no user-serviceable parts.
Contact
Outside the U.S., United Kingdom, or Ireland, contact your distributor to
request support or return a product. Visit www.chauvetlighting.com
for
contact information.
EN HIVE™ QRG
3
What Is
Included
HIVE
Power Cord
Warranty Card
Quick Reference Guide
To Begin
Unpack your HIVE and make sure you have received all parts in good
condition. If the box or contents appear damaged, notify the carrier
immediately, not CHAUVET®.
Description
The HIVE™ uses 6 large-diameter lenses to focus 18 high-
power red, green,
and blue LEDs. Control options include Sound-
Active modes, auto
programs, Master/Slave modes and DMX. Two personality choices are
available through 3- and 20-channel DMX modes.
Overview
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
Power Linking
You can link up to 5 HIVEproducts at 120 VAC and 10 units at 230 VAC.
Fuse
Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse
holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
Back Panel View
Power Out
Fuse Holder
LED Display
DMX Out
DMX In
Safety Loop
Microphone
Control
Buttons
Indicator
Lights
HIVE™ QRG EN
4
Mounting
Before mounting this product, read the Safety Notes.
Mounting
Diagram
Control Panel
Description
Button
Function
<MENU>
Exits from the current menu or function
<UP>
Navigates upwards through the menu list and increases
the numeric value when in a function
<DOWN>
Navigates downwards through the menu list and
decreases the numeric value when in a function
<ENTER>
Enables the currently displayed menu or sets the currently
selected value into the selected function
Mounting Clamp
Bracket Adjustment
Knobs (2x)
Safety Cable
Mounting Bracket
EN HIVE™ QRG
5
Menu Options
Main Level
Programming Levels
Description
Addr
001512
Sets the DMX starting address
CHnd
3CH
3-channel mode
20CH
20-channel mode
SLnd
SL 0
Slave mode 0
SL 1
Slave mode 1
AUto
rUn
Auto program
CoLo
rEd
0–255
Red (0100%)
GrEE
0–255
Green (0100%)
bLUE
0–255
Blue (0100%)
So1
Strobe, slow speed
So2
Strobe, medium speed
So3
Strobe, fast speed
LEd
on
LED background light on
oFF
LED background light off
dISP
dISP
Normal display
dSIP
Inverted display
VEr
Shows currently installed software version
DMX Linking
The HIVE™ can work with a DMX controller when linked by DMX serial
connections. Instructions for connecting and configuring this product for
DMX operation are in the User Manual. If you are not familiar with DMX,
download the DMX Primer from www.chauvetlighting.com.
Starting Address
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is 493.
Master/Slave
Connection
The HIVE uses the DMX data connection for its Master/Slave mode.
Instructions for connecting and configuring this product for Master/Slave
operation are in the User Manual.
HIVE™ QRG EN
6
DMX Values
20-CH
Channel Function Value
Percent/Setting
Pod
1
Red
000 255
0–100%
1
2
Green
000 255
0–100%
3
Blue
000 255
0–100%
4
Red
000 255
0–100%
2
5
Green
000 255
0–100%
6
Blue
000 255
0–100%
7
Red
000 255
0–100%
3
8
Green
000 255
0–100%
9
Blue
000 255
0–100%
10
Red
000 255
0–100%
4
11
Green
000 255
0–100%
12
Blue
000 255
0–100%
13
Red
000 255
0–100%
5
14
Green
000 255
0–100%
15
Blue
000 255
0–100%
16
Red
000 255
0–100%
6
17
Green
000 255
0–100%
18
Blue
000 255
0–100%
19
Strobe
000 255
Slow to fast
20
Auto Programs
000 255
Auto programs
1
2
3
4
5
6
EN HIVE™ QRG
7
DMX Values (cont.)
3-CH
Channel Function Value Percent/Setting
1 Auto Programs
000 245
Auto programs
246 255
Sound-Active mode
2
Strobe
000 255
Slow to fast
3
Speed
000 255
Auto programs speed
HIVE™ QRG Multi-Language
52
Contact Us
World Headquarters
CHAUVET®
General Information
Address: 5200 NW 108th Avenue
Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll free: 800-762-1084
United Kingdom and Ireland
CHAUVET® Europe Ltd.
General Information
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0)1773 511115
Fax: +44 (0)1773 511110
U.S. Technical Support
Voice: 954-577-4455 (Press 4)
Fax: (954) 756-8015
Email: tech@chauvetlighting.com
U.K. Technical Support
Email: uktech@chauvetlighting.com
World Wide Web
www.chauvetlighting.com
World Wide Web
www.chauvetlighting.co.uk
HIVE™
QRG Rev. 1 ML
© Copyright 2013 CHAUVET®
All rights reserved.
Printed in the P. R. C.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Chauvet HIVE Reference guide

Category
Floodlights
Type
Reference guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI