Dacor ERD60, a 60” Wide Epicure® Range, offers a variety of features for a seamless cooking experience. With its two separate dedicated circuits, one for each side, it ensures optimal power distribution. The range's manifold pressure of 5” Water Column for Natural Gas and 10” Water Column for Liquid Propane provides precise gas control. Its spacious 23 3/16" (589mm) countertop cutout allows for easy installation, while the 6” (152mm) backguard and 3” (76mm) side panels add a touch of elegance to your kitchen.

Dacor ERD60, a 60” Wide Epicure® Range, offers a variety of features for a seamless cooking experience. With its two separate dedicated circuits, one for each side, it ensures optimal power distribution. The range's manifold pressure of 5” Water Column for Natural Gas and 10” Water Column for Liquid Propane provides precise gas control. Its spacious 23 3/16" (589mm) countertop cutout allows for easy installation, while the 6” (152mm) backguard and 3” (76mm) side panels add a touch of elegance to your kitchen.

PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.7
60” Wide,
Epicure
®
Range
ERD60
1/2
Revised
06/25/08
27" (686mm)
26" (660mm)
28 1/2" (724mm)
37”
(940mm)
to
35 3/4"
(908mm)
Finished Side Panel
24 3/8" (619mm)
Rear of Control Panel/Oven Door
Face of Control Panel/Oven Door
Front Edge of Bullnose
Handle
6” (152mm) Backguard
When Backguard and
Side Panels are
removed, the overall
depth decreases
by 1" (25mm)
Accessory 3” (76mm) Side Panels
(Dacor Model No. AESP03)
1 9/16"
(40mm)
ERD/EGR30, ERD60 OVERALL DIMENSIONS
SIDE VIEW
NOTES:
1. Utilities may be located in the lower left corner of
the adjacent right cabinet. (Recommended)
2. Contact your local building department to verify
compliance with local code interpretation.
3. Two electrical circuits and gas supplies required.
WARNING
Observe all governing codes and ordinances during ◊
planning and installation. Contact your local building
department for further information.
This appliance must be installed in accordance with the ◊
accompanying installation instructions.
Dacor®
Model No.
Dedicated Circuit*
Required
Total
Connected
Load
Gas
Type
Manifold
Pressure
Min. Gas Supply
Pressure
ERD60
240 Vac, 4-wire, 60 Hz,
30 Amp (Breaker) X2
4.1 kW
(21Amp) X2
Natural 5” Water Column 6” Water Column
ERD60LP Liquid
Propane
10” Water Column 11” Water Column
ELECTRICAL AND GAS SUPPLY REQUIREMENTS
*Two separate dedicated circuits are required, one for left and one for the right side of the range.
REAR VIEW
Power Cords
60" (1524mm)
Factory installed 3/4” regulators
(1/2” supply ok)
6" (152mm)
Backguard
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.8
60” Wide,
Epicure
®
Range
ERD60
2/2
Revised
06/25/08
NOTE:
1. When backguard is removed, the side panels must
be removed.
**
** Cabinet depth is at discretion of customer
but cabinet face MUST NOT protrude further
than rear of front panel, see product dimesions
* Vertical to combustible surface
B
A
Non-Combustible
surface along
back wall
Suggested
location of
utilities
30” (762mm)
min.*
COUNTERTOP CUTOUT DIMENSIONS
(Slide-In, Freestanding Installation)
CUTOUT DIMENSIONS
(Slide-In, Self-Rimming Installation with Side Panels and Backguard Removed)
59 1/4" (1505mm)
60 1/8" (1527mm)
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
Vertical
non-combustible
surface
Rear wall
25”
(635mm)
Countertop
Countertop
Model Number “A” Cutout Width “B” Hood Width
ERD60 60 1/8” (1527mm)
Minimum
60” (1524mm)
66” (1676mm) Recommended
CUTOUT DIMENSIONS
  • Page 1 1
  • Page 2 2

Dacor ERD60 User manual

Category
Rack accessories
Type
User manual
This manual is also suitable for

Dacor ERD60, a 60” Wide Epicure® Range, offers a variety of features for a seamless cooking experience. With its two separate dedicated circuits, one for each side, it ensures optimal power distribution. The range's manifold pressure of 5” Water Column for Natural Gas and 10” Water Column for Liquid Propane provides precise gas control. Its spacious 23 3/16" (589mm) countertop cutout allows for easy installation, while the 6” (152mm) backguard and 3” (76mm) side panels add a touch of elegance to your kitchen.