EGR30

Dacor EGR30, AESP03, ERD30, ERD60, ERD60LP User manual

  • Hello! I am an AI chatbot trained to assist you with the Dacor EGR30 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What are the cutout dimensions for a slide-in, freestanding installation?
    What are the cutout dimensions for a slide-in, self-rimming installation with side panels and backguard removed?
    What is the minimum gas supply pressure for natural gas?
    What is the minimum gas supply pressure for liquid propane?
    How many dedicated circuits are required?
    What is the total connected load?
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.7
60” Wide,
Epicure
®
Range
ERD60
1/2
Revised
06/25/08
27" (686mm)
26" (660mm)
28 1/2" (724mm)
37”
(940mm)
to
35 3/4"
(908mm)
Finished Side Panel
24 3/8" (619mm)
Rear of Control Panel/Oven Door
Face of Control Panel/Oven Door
Front Edge of Bullnose
Handle
6” (152mm) Backguard
When Backguard and
Side Panels are
removed, the overall
depth decreases
by 1" (25mm)
Accessory 3” (76mm) Side Panels
(Dacor Model No. AESP03)
1 9/16"
(40mm)
ERD/EGR30, ERD60 OVERALL DIMENSIONS
SIDE VIEW
NOTES:
1. Utilities may be located in the lower left corner of
the adjacent right cabinet. (Recommended)
2. Contact your local building department to verify
compliance with local code interpretation.
3. Two electrical circuits and gas supplies required.
WARNING
Observe all governing codes and ordinances during ◊
planning and installation. Contact your local building
department for further information.
This appliance must be installed in accordance with the ◊
accompanying installation instructions.
Dacor®
Model No.
Dedicated Circuit*
Required
Total
Connected
Load
Gas
Type
Manifold
Pressure
Min. Gas Supply
Pressure
ERD60
240 Vac, 4-wire, 60 Hz,
30 Amp (Breaker) X2
4.1 kW
(21Amp) X2
Natural 5” Water Column 6” Water Column
ERD60LP Liquid
Propane
10” Water Column 11” Water Column
ELECTRICAL AND GAS SUPPLY REQUIREMENTS
*Two separate dedicated circuits are required, one for left and one for the right side of the range.
REAR VIEW
Power Cords
60" (1524mm)
Factory installed 3/4” regulators
(1/2” supply ok)
6" (152mm)
Backguard
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.8
60” Wide,
Epicure
®
Range
ERD60
2/2
Revised
06/25/08
NOTE:
1. When backguard is removed, the side panels must
be removed.
**
** Cabinet depth is at discretion of customer
but cabinet face MUST NOT protrude further
than rear of front panel, see product dimesions
* Vertical to combustible surface
B
A
Non-Combustible
surface along
back wall
Suggested
location of
utilities
30” (762mm)
min.*
COUNTERTOP CUTOUT DIMENSIONS
(Slide-In, Freestanding Installation)
CUTOUT DIMENSIONS
(Slide-In, Self-Rimming Installation with Side Panels and Backguard Removed)
59 1/4" (1505mm)
60 1/8" (1527mm)
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
Vertical
non-combustible
surface
Rear wall
25”
(635mm)
Countertop
Countertop
Model Number “A” Cutout Width “B” Hood Width
ERD60 60 1/8” (1527mm)
Minimum
60” (1524mm)
66” (1676mm) Recommended
CUTOUT DIMENSIONS
/