1. Verify that each unit is at the correct mounting height, and that they are
both aimed directly at each other.
2. Connect the UCM to the receiver and note the displayed RSSI value.
3. Adjust the receiver’s mounting height (max. ± 5 cm) and if required, the
horizontal and vertical alignment slightly to attain the maximum RSSI.
4. Measure the change in the receiver’s mounting height and adjust the
height of the transmitter to 1/2 the change.
5. Adjust the height of the receiver to the same height as the transmitter.
6. Adjust the horizontal and vertical alignment of the transmitter unit slightly
to determine if the received signal can be increased.
7. Adjust the horizontal and vertical alignment of the receiver unit slightly
to determine if the received signal can be increased.
8. Verify that the RSSI is higher or the same as it was in step 2
Final alignment
BR100 unit
post clamp
flex conduit
± 5 cm (2 in.) mounting
height adjustment
ground level
BR-100_UCM
BR-100
UCM UltraWave BR100 Status screen
Installing the Universal Configuration Module
UltraWave BR100 setup is done, using Senstar’s Universal Configuration
Module (UCM). The UCM is a Windows-based software application that
performs the calibration, setup, maintenance and diagnostic functions for
Senstar’s line of intrusion detection sensors. The UCM connects directly
to the BR100 unit via micro-USB. Silver Network based microwave units
can also connect remotely via the Network Manager software.
green shows microwave comm status OK
relay output status (green indicates relay active)
information about connected unit
Alarm status (red = alarm, purple = supervision)
current alarm history window
Input status (red = input active)
tabs provide access to UCM menus
update the unit’s firmware
diagnostic status field
(gray = OK, purple = supervision)
Calibration status:
(green = RSSI OK, yellow = RSSI too low,
red = RSSI too high
Test button activates electronic self-test
History button opens alarm history report window
The standard installation will place an icon on the desktop. Double-click
the UCM icon to sart the UCM application.
If the installation program does not auto-start, use Windows explorer
to locate and start Setup.exe.
To install the UCM application, insert the installation CD into the
appropriate drive on the computer and follow the prompts.
It is strongly recommended that the UCM computer be a portable
computer (e.g. a lap-top or notebook).
The initial setup should be done at the microwave unit’s location using a
direct USB connection to the UCM.
Connecting the UCM
Open the enclosure cover and connect the UCM computer to the
UltraWave BR100 unit via USB (T6).
Start the UCM software (the UCM Connect dialog displays):
Repeat this procedure to connect
to the second BR100 unit.
NOTE:
Network Type: Silver Network
Device Type: BR-100
connection type USB
Select Connect to establish a
connection to the unit
NOTE: Select F1 to launch the UCM online help. Refer to the BR100
Product Guide for additional information.
setup the receiver and transmitter (specify the Frequency Pair)
for Silver Network based systems, specify the network configuration
and Address
setup the Auxiliary I/O configuration (Tx and Rx)
align the transmitter and receiver
specify the Receiver’s Thresholds
UCM setup
The following setup and calibration activities must be conducted before
the UltraWave BR100 system can operate:
The RS-422 wiring connections are made on 45º spring terminals. The
spring terminals accept wire sizes from 16 to 24 AWG with a 9 mm
(0.35 in.) strip length.
Network wiring connections (RS-422)
Use single point grounding. Connect one end of the RS-422 cable’s shield
to ground. Trim back the shield at the other end of the cable and leave it
disconnected.
Network connection details
TXA+
TXA-
RXA+
RXA-
GND
RXB+
RXB-
TXB+
TXB-
RS-422
*
*
RS-422
1 2 3 451 2 3 45
TXA+
TXA-
RXA+
RXA-
GND
TXB+
TXB-
RXB+
RXB-
GND
T7 T8
set the Silver Network Address
I/O Wiring - network alarm reporting
12 to 48 VDC
power input
AUX input or
self-test input
B-Side RS-422
A-Side RS-422
1.
2.
3.
4.
Pull the network cable into the enclosure.
Using a 9/64 hex key, open the unit’s cover.
For Ethernet, terminate the cable with an RJ-45 plug.
OR
For RS-422 cable, prepare the wires for the connections.
Make the appropriate wiring connections (Ethernet or RS-422).
relays 1 & 2
Ethernet (PoE)
Surface-mount procedure
6 mm (1/4 in.) mounting holes
mounting bracket
1.
2.
3.
Remove the mounting bracket and mark the 2 mounting holes on the
mounting surface with the top of the bracket at the specified height.
Drill two holes in the mounting surface.
Attach the BR100 unit to the mounting bracket.
4.
5. Verify the mounting height and alignment.
Attach the mounting bracket to the mounting surface.
The BR100 Status window opens:
Input/output wiring and power connections
12-48 VDC
output 1 output 2
1 2 3 45
-AUX
+AUX
1 2 3 45
COM
NC
1 2 3 451 2 3 45
-VDC
+VDC
COM
NC
TXA+
TXA-
RXA+
RXA-
GND
TXB+
TXB-
RXB+
RXB-
GND
T4 T5 T7 T8
T9
auxiliary device
self-test input A-side B-side
RS-422
Ethernet (PoE)
T4 is the power input and both BR100 units operate on 12 to 48 VDC.
The 45º spring terminals accept wire sizes from 16 to 24 AWG with a
9 mm (0.35 in.) strip length.
NOTE: Use a DC power supply or PoE; not both.
For PoE the BR100 is an 802.3af class 1 device.
UltraWave BR100 unit
Each BR100 unit is mounted inside a weatherproof enclosure.
NOTE: The BR100 transmitter and receiver units are virtually identical.
antenna array
micro-USB port (connect UCM PC)
diagnostic LEDs
12 - 48 VDC power connection
AUX/self-test input
S1 tamper switch
21.5 mm cable entry port
CAUTION: The 9/64 hex screws securing the enclosure cover are
installed finger-tight to prevent damaging the gasket and inserts. DO NOT
over-tighten the cover screws.
RS-422 comms
Ethernet port (PoE)
relays 1 & 2