  • Hello! I have analyzed the user manual for the IKEA ÄLMAREN mixer tap. This document contains instructions on installation, usage, and maintenance. It also covers crucial safety guidelines, pressure and temperature specifications, and water regulation compliance details. I'm ready to answer any specific questions you might have about this device.
  • What should I do before changing the mixer tap?
    What should I do after installing a new mixer tap?
    What is important to keep in mind while tightening hoses/pipes and washers?
    What is important while installing the mixer tap based on UK water regulations?
1 2 3
4 5 6
ÄLMAREN
1 2 3
4 5 6
2AA-2256785-2
English
Installation must be performed in compliance
with current local construction and plumbing
regulations. If in doubt, contact a professional.
English
Switch o main shut-o valve before changing
mixer tap.
110084
120087
2x
1 2 3
4 5 6
3
120087
G1/2
0,2 - 10 bar
0,02 - 1 MPa
2,9 - 145 psi
Max. 176˚F
Max. 80˚C
140˚F
60˚C
0,5 - 5 bar
0,05 - 0,5 MPa
7,2 - 72.5 psi
0
2
1
3
5
7
9
46
8
10
bar psi
139269
Pre-tted
High pressure
139268
Low pressure
12
1 2 3
4 5 6
4AA-2256785-2
90˚
110084
1 2
3
4 5 6
5
1 2 3
4 5 6
6AA-2256785-2
English
Seal the open surfaces with silicone to prevent
water from penetrating the worktop upon any
leaks. Silicone is not included.
Ø 34 - 37 mm
(1 3/8 - 1 1/2")
55 mm Max.
2 3/16" Max.
1 2
3
4 5 6
7
Ø 34 - 37 mm
(1 3/8 - 1 1/2")
3
8AA-2256785-2
1 2 3
4
5 6
9
1 2 3
4
5
6
10 AA-2256785-2
1 2 3
4 5
6
11
English
IMPORTANT! Do not tighten too hard: this can
damage hoses/pipes and washers.
1 2 3
4 5 6
12 AA-2256785-22022-04-07© Inter IKEA Systems B.V. 2020
English
Before use: Unscrew the Aerator/Flow Guide with
a coin and allow the water to run freely for a few
minutes. Then screw the Aerator/Flow Guide back
in place up to the stop DO NOT OVER TIGHTEN.
English
Check at regular intervals to make sure that the
installation is not leaking.
English
To comply with UK water regulations, this
product shall be installed in accordance with the
following:
Inlet supply hoses shall be installed where light is
excluded.
Water supplies shall be at reasonably balanced
pressures from a common source (e.g. hot and
cold supplies both from the same storage or
both from a supply pipe). Where the tting is
supplied from unbalanced supplies (e.g. hot
and cold supplies from separate sources) an
Approved’ single check valve or some other no
less eective backow prevention device shall be
tted immediately upstream of both hot and cold
water inlets.
Pull-out taps warning AI text UK
This type of tap will not maintain an appropriate
tap gap,because part of the tap assembly (the
hose attachment) can fall below the spill over
level of the sink.Therefore it must not be directly
connected to the drinking water supply without
the protection of an appropriate backow
arrangement, as agreed by your local water
supplier.If the tap assembly is required to be
fed from storage, this tap may require a water
pressure higher than that provided by a normal
storage gravity fed system (e.g. typical gravity
fed system - 0.5 bar).If boosting/pumping of the
system is required advance notication to the
local water supplier may be required.The tap
assembly must only be supplied via a wholesome
source of water (hot and cold supplies).It is
important to ensure that this tap is connected in
accordance with the Water Supply (Water Fittings)