Tetra GEPSJB60 is a power supply junction box designed for use with Tetra power supplies. It supports a range of models, including GEPS12-60, GEPS12D-60U, and GEPS24-80, among others. The junction box can be used on the primary side of these power supplies or any other compatible power supply with a class 2 output. It is suitable for dry or damp locations and features multiple wire entry knockouts for easy installation. The box also includes a ground screw for connecting the AC line ground wire.

Tetra GEPSJB60 is a power supply junction box designed for use with Tetra power supplies. It supports a range of models, including GEPS12-60, GEPS12D-60U, and GEPS24-80, among others. The junction box can be used on the primary side of these power supplies or any other compatible power supply with a class 2 output. It is suitable for dry or damp locations and features multiple wire entry knockouts for easy installation. The box also includes a ground screw for connecting the AC line ground wire.

Installation Guide
SIGN108
Junction Box Features
Installation
Remove screw and lock washer and snap the top
cover o of the junction box.
Select a wire entry knock out location and carefully
remove metal plug. Install wire box tting and supply
wire and secure in place.
GEPSJB60 supports: GEPS12-60, GEPS12D-60U, GEPS24-80, GEPS24D-80U,
GEPS12-60U-NA, GEPS12SE-60U-NA, GEPS12-60U-GL, GEPS24-100U-NA,
GEPS24-100U-GL, GEPS24-100U-GLX
Can be used on primary side of the power supplies listed above; or any other
power supply that similarly ts, with a class 2 output where otherwise acceptable
in the application.
Suitable for dry or damp locations
1 2
Power Supply Junction Box
GEPSJB60
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK:
Disconnect power at fuse box or circuit breaker before servicing
or installing product.
Properly ground Tetra® power supply.
RISK OF FIRE:
Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm2).
Use only approved wire for input connection. Maximum size 14
AWG; minimum 75C rated.
Branch circuit limit of 15A.
Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur
avant l’entretien ou l’installation du produit.
Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
N’utilisez que des ls approuvés pour les entrées/sorties de connexion. La
taille maximale 14 AWG; minimum 75C nominale.
Respectez tous les codes locaux.
Tetra® Power Supply GEPSJB60 Installation Guide
gecurrent.com/tetra
© 2022 Current Lighting Solutions, LLC. All rights reserved. Information and specications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 2
(Rev 03/06/23)
SIGN108
Trim ush
with power
supply edge
Neatly fold wires within the
Junction Box and reattach cover
with mounting screw and washer.
Tighten securely.
Complete installation. Continue
with LED light engine connections.
For all other power supplies: Slide junction box onto
AC input end of power supply and align mounting
holes. Ensure power supply mounting tab is under the
junction box.
For GEPS24-100U-GLX only: On the AC input end
of power supply, trim or grind sides of mounting tab
ush with power supply. Then slide junction box onto
AC input end of power supply and align mounting
holes. Ensure power supply mounting tab is inside the
junction box.
Connect AC line ground wire to Junction Box ground
screw.
Mount and secure Junction Box and Tetra Power
Supply using #6 or #8 screws and star-type lock
washers in both holes.
Connect Tetra Power Supply to AC
line per instructions enclosed with
the power supply.
Conforms to the following standards:
Power supply
mounting tab is
inside junction box
AC input end of
GEPS24-100U-GLX
power supply
Power supply mounting
tab is under junction box
6
4
3A 3A
7 8
5
  • Page 1 1
  • Page 2 2

Tetra GEPSJB60 Installation guide

Type
Installation guide

Tetra GEPSJB60 is a power supply junction box designed for use with Tetra power supplies. It supports a range of models, including GEPS12-60, GEPS12D-60U, and GEPS24-80, among others. The junction box can be used on the primary side of these power supplies or any other compatible power supply with a class 2 output. It is suitable for dry or damp locations and features multiple wire entry knockouts for easy installation. The box also includes a ground screw for connecting the AC line ground wire.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages