Hitachi NT 50AE2 Instruction and safety User manual

Type
User manual

This manual is also suitable for

O-Ring Shown Actual Size
STAPLER
MODEL N 3804AB3
FOR USE BY ONLY SERVICE PERSONNEL TRAINED
BY HITACHI, DISTRIBUTOR OR EMPLOYER.
Kit-
For air leakage or sluggish operation.
※ Development uses NT50AE2
2
Cap
Head Valve (A)
Head Valve Spring
1
Item
No.
Code No. Part Name
885-868 Gasket
878-600 Head Valve O-Ring
886-068 O-Ring
885-871 O-Ring
301-684 O-Ring
986-374 O-Ring
1
2
3
4
5
6
Cyliner Plate
Cylinder
Body
Piston Ass’y
6
5
4
3
BRAD NAILER
MODEL NT 50AE2
BRAD NAILER
MODEL NT 32AE2
GENUINE PARTS
9. Pay attention not to scratch exhaust cover
and body when remove old gasket.
Install new o-rings as shown right.
Install cylinder with cylinder plate and piston
ass’y into body.
Make sure that head valve spring and
head valve o-ring are properly placed in
head valve(A).
Install head valve piston into exhaust cover.
10. Install packing, cap and four bolts.
Using Allen wrench for M5 screw,
tighten four bolts in a staggered sequence.
11.
(1) DISCONNECT AIR HOSE FROM NAILER
[STAPLER]. REMOVE ALL NAILS
[STAPLES] FROM NAILER[STAPLER].
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
THE PUSH LEVER AND TRIGGER
MUST MOVE SMOOTHLY.
(2) Adjust the air pressure to 70 psi
(4.9 bar 5 kgf/cm
2
). Connect the
air hose. Do not load any nails
[staples] in the Nailer [Stapler].
Set the switching device to the
upward position (SINGLE
ACTUATION MECHANISM).
(Set the switching device to the
upward position comnpletely as shown in the diagram.Otherwise, it will not
 operate properly.)
THE NAILER[STAPLER] MUST NOT LEAK AIR.
(3) Remove the finger form the trigger and press the push lever against the
workpiece.
THE NAILER[STAPLER] MUST NOT OPERATE.
(4) Separate the push lever from
the wood. Next, point the nailer
[stapler] downward, pull the
trigger and then wait in that
position for 5 seconds or longer.
THE NAILER[STAPLER]
MUST NOT OPERATE.
(5) Without touching the trigger, depress the push lever against the workpiece.
Pull the trigger.
THE NAILER[STAPLER] MUST OPERATE.
Hold the trigger back while separating the push lever from the wood.
The nailer[stapler] will remain in operated status (the driver blade will remain
at the bottom).
Remove the finger from the trigger.
Nailer[Stapler] operation will end (the driver blade will return to the top).
(6)Set the switching device to the downward
position (CONTACT ACTUATION MECHANISM).
(Set the switching device to the downward position
completely as shown in he diagram. Otherwise, it will
not operate properly.)
With the Nailer[Stapler] off the workpiece, pull the
trigger. Depress the push lever against the workpiece.
THE NAILER MUST OPERATE.
(7) If no abnormal operation is observed, you may load nails[staples] in the Nailer
[Stapler]. Drive nails[staples] into the workpiece that is the same type to be used
in the actual application.
THE NAILER[STAPLER] MUST OPERATE PROPERLY.
12. Change the WARNING LABEL if missing
or damaged.
A new WARNING LABEL is available from
a Hitachi authorized service center.
2. Disconnect the air hose from the
Nailer[Stapler].
4. Using Allen wrench for M5 screw,
remove four bolts from cap.
Remove cap.
6. Remove head valve(A) from exhaust
cover.
HOW TO REPAIR
  
1. The tools needed for repair are shown
below.
3. Remove all nails[staples] from the
 Stapler[Nailer].
5. Remove piston ass’y and cylinder.
7. Using o-ring pick, remove old o-rings.
Discard old o-rings.
IMPORTANT SAFETY INSTRUCTIONS
READ AND UNDERSTAND THIS MANUAL BEFORE DOING REPAIRS.
Only service personnel trained by Hitachi, distributor or employer shall
repair the Nailer[Stapler( in case of N3804AB3)].
Use only parts supplied or recommended by Hitachi for repair.
Before doing repairs,
1) WEAR SAFETY GLASSES;
2) DISCONNECT AIR HOSE FROM NAILER[STAPLER]; and
3) REMOVE ALL NAILS[STAPLES] FROM NAILER[STAPLER].
After doing repairs,
TEST NAILER[STAPLER] PER ITEM No. 11 OF THIS MANUAL
BEFORE USE.
If you have any questions regarding repair, use or safety warnings, call a
Hitachi authorized service center. If you need to locate a Hitachi autho-
rized service center, please call Hitachi Power Tools U.S.A. Ltd. at 1-800-
546-1666.
CAUTION ON REPAIR
Oily or greasy hands can slip easily.
Do not allow dust or foreign matter to enter Nailer[Stapler].
Do not scratch the O-rings or O-ring contacting surface of any parts.
When reassembled, always conduct
following tests in the following order.
If abnormal operation occurs, stop
using the Nailer[Stapler] and contact
a Hitachi
DANGER
1
A
llen Wrench Fo
r
M5 Screw
O-Rin
g
Pick
2
Figure uses NT50AE2.
[ ] are in case of N3804AB3.
C
y
linde
r
Piston Ass’
y
5
3
6
Exhaust cove
r
Head Valve (A)
7
O-Rin
g
Pick
old O-Rin
g
8.Wipe body, exhaust cover, head valve(A),
cylinder and cylinder plate with clean cloth.
Put an adequate amount of grease on
shaded area of body, exhaust cover, head
valve (A), cylinder and cylinder plate. Put an adequate amount of grease on
new o-ring.
Cylinder Plate
Head Valve
Spring
Head
Valve(A)
C
y
linde
r
Piston Ass’
y
9
10
Exhaust Cove
r
Bolt
Tri
e
Push
Lever
Do no
t
connect
air hose
11-
(
1
)
Do not pull
Trigger
Upward position
Switching Device
Depress
Push Lever
11-
(
2
)(
3
)
Head Valve (A)
Cylinder PlateExhaust Cove
r
Cylinde
r
Bod
y
Pull Trigge
r
Upward position
Switching Device
11-
(
4
)
11-
(
6
)
Downward position
Switching
Device
12
Warnin
g
Label
708
Code No. C99521611
Printed in Taiwan
8
Exhaust cove
r
Bolt
4
  • Page 1 1
  • Page 2 2

Hitachi NT 50AE2 Instruction and safety User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI