KitchenAid KUDL01IL Installation guide

Type
Installation guide
KJtchen_kid _ Undercounter Dishwasher
PRODUCT MODEL SERIES
KUDCO1TM KUDP01FL
KUDIO1DL KUDPO1IL
KUDIO1FL KUDSO1DL
KUDIO1IL KUDSO1FL
KUDL01 IL KUDS01 IL
KUDPO1DL KUDSO1VM
Electrical: 120-volt, 60 Hz,AS-only, 15 or
20 amp electrical supply. Usecopper wire only.A
time-delay fuse or circuit breaker and separate
circuit is recommended.
Water: A hot water line with 20-120 psi
(138-862 kPa) water pressure.Watertemperature
must be minimum 120°F (49°0) at dishwasher.
Use 3/8" O.D.copper tubing with compression
fitting or flexible stainless steel braidedfill line
(1/2" minimum plastic tubing is optional but not
recommended). Usea 90° elbow with 3/8" N.RT.
external pipethreads on one end to connect to
water inlet valve. Do not solder within 6"(15.2 cm)
from water inlet valve.
Drain: Usethe new drain hose supplied with your
dishwasher. Ifthis is not suitable, use a newdrain
hosewith a maximum length of 12feet (3.7 m)
that meets all current AHAM/IAPMOtest
standards, is resistant to heatand detergent, and
fits the drain connector of the dishwasher. Must
havea high drain loop 20 inches (50.8 cm) above
the subfioor or floor. Connectdrain hoseto waste
tee or disposer inlet above drain trap in house
plumbing and 20 inches (50.8 cm) minimum
abovethe floor. An air gap must be used if the
drain hose is connected to house plumbing lower
than 20 inches (50.8 cm) above subfioor or floor.
Use 1/2" minimum I.D. drain line fittings.
Corner installation: Allow 2" (5,1 cm)
minimum betweencorner wall and dishwasher
opening.
Grommet is required for electrical cable or power
supply cord hole cut in a metal cabinet.
Do not install dishwasher over carpetedfloor.
Unit acceptscustom door panels.
CUSTOM FRONT PANEL DIMENSIONS
OVERALL DIMENSIONS
*For models using a 3/4"
(1.gcm) custom wood front
panel, this dimension is
24-3/4" (62.9 cm).
-_---23-7/8" (60.6 cm)_
3/4" (1.9 sin) insulation -
may be compressed
(not used onall models)
top vent
,,,_24-1/2" (62.2 cm)* _,medel
/
_- 21" (53.3 cm) -_
CABINET OPENING DIMENSIONS
3/4" (1.g cm) insulation -
may he compressed
(not used on aH models)
_-_24-7/8" (63.2 sin)
24-1/2" (62.2 sin)*
21" (53.3 sin)
front vent
model
33-7/8"
(86 cm) min.
with wheels
removed
__.4" (61 urn)**
All sudaces must he free
from intrusions
2-3/4" 3-1/4"
(7 urn) (8.3 urn)
Water line should enter through the
left side of opening in shaded areas.
Minimum 1/2" (12,7 ram} hole.
(5.1 urn}
(25.4
*Measured from the lowest point on the underside of conntedop.
34" (86.4 urn) min.*
(8.3era) (7 cm}
Drain hose and power supply line should enter through the
right side of opening hi shaded areas.
Drain hose size: 1-1/2" (3.8 cm)
Power supply line hoJe-dffect wired: 3/4" (1.gcm)
Powersupplyline hole-withplug:1-1/2" (3.8 uln)
May he reduced to 33-7/8" (86 cm) by removing wheels from dishwasher.
**Minimum, measured from narrowest point of opening.
***May he increased to 6-5/8" (16.6 urn} if height uf opening is 34-1/2" (87.6 urn} at its lowest point•
A customtrent panel
must weigh no mere
than 16 poundsand
mast he made to these
dimensions.
3/4"
(19.1 mm)
FrontView
Front Vented Models
t
"25-29/32
(65.8 cm)
,ron_tPt
1/8 (3•2 ram)
(3.2ram)
Side
View
I___ 23-3/8 __:_ 3/4--_
(59.4 cm) (1.9 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our Dimensions arefor planning purposes only. For complete details, see Installation Ref.8564554
products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. 10-04-04