  • Hello! I am an AI chatbot trained to assist you with the Greenlee 690 & 690-22 Fishing System User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
REPLACEMENT MOTOR COVER
FOR
690, 690-22
SERVICE BULLETIN 288
999 4008.6 © 2001 Greenlee Textron SB 288 7/01
If the 690 unit was built prior to serial number AAR 3800 (115V)
or AAT 0050 (220V) it may be necessary to enlarge the ø.733
power cord hole to ø.886 to accept the strain relief connector.
Support the cover wall using a wood block and drill the hole with
a Greenlee 34411 Kwik-Stepper Step-Bit.
5.13 REF
ø .886
1.39 REF.
Printed in the U.S.A.