Atlas Metal Industries RB-5 Installation guide

Type
Installation guide

This manual is also suitable for

Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail:
PARTS LIST REFRIGERATED BASE
RB-4, RB-5 & RBD-5 SERIES
5
4
1
RB-5 SHOWN
3
2
6
7
ITEM
PART
DESCRIPTION
7008-0 RBD-5 Drawer Gasket (Unit not Shown)
97-105 RB-4 & RB-5 Large Door Gasket
1
97-107 RB-5 Small Door Gasket
2 S90253-4 Door Assembly RB-4 & RB-5
3 S83951-0 Door Assembly RB-5
6055-1 Slam Action Latch
4
6052-1 Slam Action Latch W/Lock
5 6053-8 Hinge & Cover
S84051-0 RB-4 Grill
6
S84050-0 RB-5 Grill
7 113-5 Thermometer
8 2060-1 Condensate Water Evap. (Not Shown)
9 1002-0 Power Cord (Not Shown)
10 2006-4 1/4 H.P. Compressor (Not Shown)
Evaporator Coil RB-5 (Not Shown)
11 2119-0
Evaporator Coil RB-4 (Not Shown)
12 22-1406 Thermostat (Not Shown)
13 2013-0 Fan Motor (Not Shown)
14 2014-5 Fan Blade (Not Shown)
15 S81441-0 Fan Guard (Not Shown)
16 S81419-0 Fan Bracket (Not Shown)
17 1149-0 Wire Harness (Not Shown)
18 S83952-0 Tray Rack (Not Shown)
19 2026-0 0.042 Cap Tube (Not Shown)
20 2025-0 Drier (Not Shown)
SLIDE- IN REFRIGERATED BASE
RB & RBD SERIES
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
MODEL
STORAGE
CAPACITY 12 “ X 20” PANS
CUT-OUT
REQUIRED
RB-4
10 Pans- 1 Door
8 cu. ft.
23 1/2" X 55 1/2"
RB-5
15 Pans- 2 Doors
10 cu. ft.
23 1/2" X 69 1/4"
OPERATION
The unit is ready to operate as soon as it is plugged in and turned on. The thermostat has an off position and
numbers from #1 through #7 (number 7 is the coldest). The unit has been pre-tested and set for proper operation
with the thermostat set for 35˚ to 40˚. Do not block air discharge openings inside the base of the unit. A timer is
installed in the system to shut the compressor off every 4 hours (approximately 15 minutes) to eliminate ice build
up on the evaporator coil.
The unit is supplied with a power cord and NEMA plug. Refer to the data plate located in the compressor
compartment for the amperage and voltage information. Use a licensed electrician when installing power source.
Note: Proper ventilation must be provided in counter.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
MAINTENANCE
NEVER CLEAN THE UNIT WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER
CLEANING COULD SCAR, MARK AND/OR CORRODE METAL. DO NOT USE STEEL WOOL OR
ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE
ALL RESIDUES.CLEAN CONDENSER COIL REGULARLY. FAILURE TO MEET THESE
CONDITIONS WILL VOID WARRANTY.