Silvercrest 56861 User manual

Type
User manual
3 GB
Table of Contents
Introduction
Proper Use ....................................................................................Page 7
Supply Scope ...............................................................................Page 8
Description of Parts .......................................................................Page 8
Technical Data ..............................................................................Page 9
Safety Instructions ...................................................................Page 10
Before you start.........................................................................Page 15
Set the time ...................................................................................Page 16
Operation
Connecting the electrical appliance to be tested ....................... Page 17
Current measurement ................................................................... Page 17
Maximum current .........................................................................Page 18
Measure power consumption ......................................................Page 19
Maximum power consumption .................................................... Page 19
Delete maximum values ...............................................................Page 20
Set the overload warning value ..................................................Page 20
Measure mains voltage................................................................Page 21
Measure mains frequency ...........................................................Page 22
Show power factor .......................................................................Page 22
Set electricity rate 1 and 2 ..........................................................Page 23
Set electricity flat-rate ................................................................... Page 25
Total energy consumption ............................................................Page 27
Time measurement function ..........................................................Page 28
Show energy costs .......................................................................Page 29
Set the Energy consumption / Time measurement function /
Total cost display to 0 .................................................................. Page 30
Changing the batteries .................................................................Page 30
Restore delivery condition ............................................................Page 31
Cleaning and Care ....................................................................Page 32
Disposal ..........................................................................................Page 32
Warranty and Service
Warranty Declaration .................................................................. Page 34
Service Address ............................................................................ Page 34
Declaration of Conformity............................................................Page 35
Manufacturer ................................................................................ Page 35
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 3 30.11.10 14:12
4 GB
kWh
8
12
13
18
7
9
11
10
19
18
17
16
A
UP DOWN PRICE SET
45
20
1415
1
236
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 4 30.11.10 14:12
5 GB
21
B
22
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 5 30.11.10 14:12
6 GB
Introduction
The following pictograms are used in these
operating instructions / on the device:
Read instruction manual!
Observe caution and safety notes!
Caution electric shock! Danger to life!
Risk of explosion!
Keep children away from electrical devices!
For use in dry rooms only.
V
~
Volt (AC)
W
Watts (Effective power)
Hz
Hertz (mains frequency)
A
Amp
kWh
Kilowatt hour
Direct current (Type of current and voltage)
Proper procedure and handling.
Dispose packaging and appliance in an
environmentally-friendly way!
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 6 30.11.10 14:12
7 GB
Introduction
Energy Monitor
Q
Introduction
Familiarise yourself with the product before using
it for the first time. Please read the following
operating manual and safety instructions carefully.
Always use the instrument only as described and for the stated
areas of use. Keep this manual in a safe place. Make sure
that all documents accompany the instrument if you pass it
on to anyone else.
Q
Proper Use
The appliance is designed to measure the power consumption
of electrical appliances and to calculate electricity and oper-
ating costs. Any other use or modification of the instrument
constitute improper use and carry a serious risk of accident.
The manufacturer is not liable for damage caused by improper
use. The instrument is not intended for commercial use.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 7 30.11.10 14:12
8 GB
Introduction
Q
Supply Scope
1 x wattmeter
2 x round cell batteries (Alkaline LR44, 1.5 V )
1 x operating manual
1 x warning labels for the battery compartment cover in
other languages
Q
Description of Parts
1
LC display
2
SET button
3
PRICE button
4
DOWN button
5
UP button
6
Socket
7
OVERLOAD / overload symbol
8
Watt symbol / overload warning value power consump-
tion (W)
9
Ampere symbol / overload warning value current
consumption (A)
10
Volt symbol
11
Hz / mains frequency symbol
12
TIME / time symbol
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 8 30.11.10 14:12
9 GB
Introduction
13
€ / cost symbol
14
2nd electricity tariff
15
symbol (setting the time)
16
Total symbol
17
Kilowatt-hours symbol
18
Power factor / power factor symbol
19
PRICE kWh / price per kWh symbol
20
Max symbol
21
Battery compartment cover
22
Plug
Q
Technical Data
Model: EM 240-A DE
Input voltage: 230 V
~
, 50 Hz
Max. permissible load: 16 A
~
, 3500 W
Type of battery: 2 x LR.44 (Alkaline)
1.5 V
Lower limit range
for current measurements: 0.005 A
Ampere indicating range: 0.00 - 16 A
Volt indicating range: 190 - 276 V
~
Watt indicating range: 0 - 3500 W
Kilowatt hour indicating range: 0.00 - 9999 kWh
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 9 30.11.10 14:12
10 GB
Introduction / Safety Instructions
Mains frequency indicating range: 40 - 70 Hz
Resolution: 0.5 W
Enviromental conditions:
Altitude: max. 2000 m
Temperature: + 5 °C - + 40 °C
Relative humidity: max. 90 %
Tolerance range:
in volts: ± 3 %
in amperes: ± 3 %, ± 0.01 A
in watts: ± 3 %, ± 2 W
Dimensions of LCD: 3.2 x 3.2 cm (W x H)
Safety Instructions
WARNING!
Please read all the safety information
and instructions. Failure to observe the safety information
and instructions can result in electric shock, fire and / or
serious injury.
PLEASE RETAIN ALL SAFETY INFORMATION AND
INSTRUCTIONS FOR FUTURE REFERENCE.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 10 30.11.10 14:12
11 GB
Safety Instructions
How to avoid fatal injury
by electric shock!
J Inspect the wattmeter, additional equipment and the
electrical appliances you wish to test before every use to
ensure that they are intact. Damaged electrical appliances
and buckled / kinked mains leads or bare wires increase
the risk of an electric shock.
J Do not operate the wattmeter if mains leads or mains
plugs on the electrical appliances you wish to test are
damaged.
CAUTION! Damaged mains leads pose a risk of fatal
injury by electric shock.
J The connector plug
22
of the wattmeter must fit into the
outlet. The connector plug
22
must not be modified in any
way. Do not use adapter plugs in conjunction with earthed
electrical appliances. Using unmodified mains plugs and
proper outlets reduces the risk of an electric shock.
J Avoid physical contact with earthed surfaces such as those
of pipes, heaters, ovens and fridges. There is an increased
risk of an electric shock if your body is earthed.
J Keep the wattmeter away from rain and
moisture. If water enters the wattmeter there
is an increased risk of an electric shock.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 11 30.11.10 14:12
12 GB
Safety Instructions
J Only operate the wattmeter in dry clothing and preferably
shoes with a rubber sole or standing on an insulating mat.
J Only measure voltages of over 25 V
~
in compliance
with the relevant safety instructions for the electrical
appliance you wish to test.
J Never under any circumstances open up the housing of
the wattmeter. If the wattmeter does not work properly
or is damaged, please have it repaired immediately by
a specialist.
J Do not operate the wattmeter outdoors.
J Always remove the electrical appliances you are testing
from the socket
6
directly by the mains plug and never
using the mains lead.
J Remove the wattmeter from the outlet when you have
finished using it.
How to avoid personal injury and
damage to the product!
J
RISK OF FATAL INJURY AND ACCIDENTS
FOR INFANTS AND CHILDREN! Never
leave children unattended with the packaging
materials or the product. The packaging material carries
a risk of suffocation and there is a risk of fatal injury by
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 12 30.11.10 14:12
13 GB
Safety Instructions
electric shock. Children often underestimate dangers.
Always keep children away from the product.
J CAUTION! DANGER OF EXPLOSION!
Never operate the wattmeter where there is
any risk of explosion, i.e. close to inflammable
liquids or gases.
J Never exceed the stated maximum input voltage.
J Avoid strong vibrations or shocks.
J Never expose the wattmeter to extreme temperatures,
extreme sunlight, humidity or moisture.
J Never expose the wattmeter to extreme temperature
fluctuations. Do not use the wattmeter until it has become
adjusted to the ambient temperature.
J Never operate the wattmeter close to strong magnetic
fields such as motors, transformers or similar.
J Do not place the wattmeter face down on workbenches
or working surfaces. This helps to prevent damage to the
operating elements and the LCD
1
.
J Remove the batteries from the wattmeter if you do not
intend to use if for any length of time.
J Do not connect after each other.
J Use the power cost meter only in buildings equipped under
Installation Category II (CAT II) according to IEC 664.
The maximum peak voltage must not exceed 2500 V
~
.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 13 30.11.10 14:12
14 GB
Safety Instructions
The main electricity supply for residential buildings usually
falls under Installation Category II.
Safety Instructions for Batteries!
J Remove batteries that have not been used for any length
of time from the instrument.
J CAUTION! DANGER OF EXPLOSION!
Never recharge batteries.
J Make sure when inserting the batteries that the polarity
is correct. This is indicated in the battery compartment.
J If necessary, clean the battery and instrument contacts
before inserting the batteries.
J Remove spent batteries from the instrument immediately
on account of the increased risk of leakage.
J Batteries must not be disposed of in household waste.
J Consumers are under a legal obligation to dispose of
batteries properly.
J Keep batteries out of the reach of children, do not dispose
of them in fire, do not short-circuit them, and do not take
them apart.
J Failure to observe these instructions may result in the
batteries discharging beyond their end voltage, which
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 14 30.11.10 14:12
15 GB
Safety Instructions / Before you start
carries a risk of leakage. If the batteries in your instrument
have leaked, remove them immediately to prevent damage
to the instrument.
J Avoid contact with skin, eyes and mucous membrane. In
the event of contact with battery acid, rinse the affected
area with plenty of water and / or consult a doctor.
J Unplug the appliance before changing the batteries.
J The battery compartment cover
21
must be completely
inserted before bring into operation.
Q
Before you start
Note: first stick the enclosed label onto the battery
compartment cover
21
.
Note: two round cell batteries (Alkaline LR44, 1.5 V )
are already inserted in the wattmeter on delivery.
j Remove the battery compartment cover
21
by unscrewing
the two screws with a suitable screwdriver.
j Remove the isolating strip from between the two round
cell batteries (Alkaline LR44, 1.5 V ) on the back of
the battery compartment cover
21
.
j Close the battery compartment by replacing the battery
compartment cover
21
. Please make sure that you
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 15 30.11.10 14:12
16 GB
Before you start
retighten the two screws firmly.
Note: Make sure that you replace the battery compart-
ment cover
21
the right way round. The rounded corners
of the battery compartment cover
21
must fit into the
rounded recesses in the battery compartment.
j The wattmeter is now ready for operation.
Q
Set the time
The time is displayed as soon as the isolating strip has been
removed. The symbol
15
also appears.
j Press the “PRICE” button
3
until the time appears in the
bottom third of the LC display
1
.
j Press the “SET” button
2
for approx. 3 seconds. The
time display flashes.
j Press the “UP” button
5
to set the hours.
j Press the “DOWN” button
4
to set the minutes.
j Press the “SET” button
2
to switch between 12 and
24-hour format.
j Press the “PRICE” button
3
to confirm your setting.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 16 30.11.10 14:12
17 GB
Operation
Q
Operation
Q
Connecting the electrical
appliance to be tested
c CAUTION! RISK OF FATAL INJURY BY ELECTRIC
SHOCK! Only measure voltages of over 25 V
~
in compli-
ance with the relevant safety instructions for the electrical
appliance you wish to test.
m CAUTION! RISK OF INJURY! Never exceed the
stated maximum input voltage.
j Plug the wattmeter into a suitable outlet.
j Now plug the mains plug of the electrical appliance you
wish to test into the socket
6
of the wattmeter.
Q
Current measurement
j Press the “UP” button
5
until the Ampere symbol
9
appears in the top third of the LC display
1
.
Note: the “Current measurement” function is the stand-
ard setting for the wattmeter. As soon as the isolating
strip between the two round cell batteries is removed,
the wattmeter is automatically in this mode.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 17 30.11.10 14:12
18 GB
Operation
j The LCD
1
now indicates the present current in A
(Ampere) required for use of the electrical appliance.
Note: you can also call up the current reading when
the wattmeter has been removed from the outlet or when
the electrical appliance you are testing is no longer
connected to the wattmeter. As soon as you take a new
measurement, the old current is overwritten.
Q
Maximum current
j Press the “UP” button
5
until the Max symbol
20
and
the Ampere symbol
9
appear in the top third of the
LC display
1
.
j The LCD
1
now indicates the maximum required current
in A (Ampere) measured with the wattmeter so far.
Note: you can also call up the maximum current reading
when the wattmeter has been removed from the outlet or
when the electrical appliance you are testing is no longer
connected to the wattmeter.
Note: the maximum current value is saved until a higher
value is measured. The old value is then overwritten by
the new measurement.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 18 30.11.10 14:12
19 GB
Operation
Q
Measure power consumption
j Press the “UP” button
5
until the Watt symbol
8
appears in the top third of the LC display
1
.
j The LCD
1
now indicates the present power consumption
in W (Watt) required for use of the electrical appliance.
Note: the power consumption is calculated according
to the following formula: power = voltage x current x
power factor.
Q
Maximum power consumption
j Press the “UP” button
5
until the Max symbol
20
and the Watt symbol
8
appear in the top third of the
LC display
1
.
j The LCD
1
now indicates the maximum power consump-
tion in W (Watt) measured by the wattmeter so far.
Note: you can also call up the maximum power consump-
tion reading when the wattmeter has been removed from
the outlet or when the electrical appliance you are testing
is no longer connected to the wattmeter.
Note: the maximum power consumption is saved until
a higher value is measured. The old value is then over-
written by the new measurement.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 19 30.11.10 14:12
20 GB
Operation
Q
Delete maximum values
j Use the “UP” button
5
to select one of the two maxi-
mum values (see “Maximum current”, “Maximum power
consumption”).
j Keep the “SET” button
2
pressed for approx.
3 seconds to set the maximum value to 0.
Q
Set the overload warning value
Note: in this mode you have a choice between two overload
warning values. You can set an overload warning value for
the current (A) and an overload warning value for the power
consumption (W).
Note: the overload warning value for power consumption
(W)
8
is set by default to 0,0 W on delivery.
Proceed as follows:
1. Press the “UP” button
5
until the overload symbol
7
(“OVERLOAD”) appears in the top third of the LC
display
1
.
2. Now press the “SET” button
2
. The ampere symbol
9
starts to flash.
3. Press the “UP”
5
or “DOWN” button
4
to select either
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 20 30.11.10 14:12
21 GB
Operation
the overload warning value for power consumption (W)
8
or the overload warning value for current (A)
9
.
4. Press the “SET” button
2
. The first digit flashes.
5. Press the “UP”
5
or “DOWN” button
4
to set the
required value.
6. Press the “SET” button
2
to move to the next digit.
7. Repeat steps 5 and 6 until you have set the required
overload warning value.
8. When you have set the value for the last digit, press the
“PRICE” button
3
to confirm your entry.
Note: as soon as the entered overload warning values are
exceeded by any connected electrical appliance you are
testing, the overload symbol
7
flashes and a warning
signal sounds.
Q
Measure mains voltage
j Press the “DOWN” button
4
until the Volt symbol
10
appears in the centre of the LC display
1
.
Note: the “Measure mains voltage” function is the
standard setting for the wattmeter. As soon as the isolating
strip between the two round cell batteries is removed, the
wattmeter is automatically in this mode.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 21 30.11.10 14:12
22 GB
Operation
j The LCD
1
now indicates the present mains voltage
in V (volts).
Q
Measure mains frequency
j Press the “DOWN” button
4
until the power frequency
symbol
11
(Hz) appears in the centre of the LC display
1
.
j The LCD
1
now indicates the present mains frequency
in Hz (Hertz).
Note: the wattmeter indicates mains frequencies in a
range of 40 to 70 Hz. In Europe a frequency of 50 Hz is
used for the general power supply system.
Q
Show power factor
j Press the “DOWN” button
4
until the power factor
symbol
18
(“Power Factor”) appears in the centre of the
LC display
1
.
j The LC display
1
now indicates the power factor.
Note: the power factor expresses the ratio of real
(active) to theoretical (apparent) power consumed by
an electrical device. The power factor can be between
0 and 1. Ideally, the power factor is 1.
56861_Energiekostenmessgeraet_Content_GB-HU-SI-DE.indd 22 30.11.10 14:12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144

Silvercrest 56861 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages