RAIN GUARD CU-0205 User manual

Type
User manual

This manual is also suitable for

Rainguard
®
Clear-Seal Acrylic
Clear-Seal
Acrylic
Urethane
technical data sheet
100% Urethane Water Repellent
Page 1 of 3Customer Service Help-Line 800.272.4647 RainguardPro.com
Description
Rainguard Clear-Seal Acrylic Urethane Sealer is
a single-component, self cross linking urethane/
acrylic sealer and nish coat for decorative
concrete, stone, and other masonry surfaces
Clear-Seal, a waterbased, low VOC, low odor
coating can protect your masonry against
chemical spills and staining agents, UV light, and
wear due to heavy foot and tire trafc.
Clear-Seal is formulated for use on horizontal or
vertical painted or unpainted concrete and wood
surfaces. It may be used as a clear sealer
on commercial, warehouse, or industrial oors,
residential or commercial garage spaces, brick
pavers, or other masonry surfaces.
Features
Impact and wear resistant
Resists hot tire pick-up
Non-yellowing formulation
Resistant to stains, acids, bases, gasoline,
alcohol and oil (vegetable and motor)
Low odor
Non-hazardous
Resists UV rays
Environmentally-friendly
Water clean-up
Excellent adhesion
Fast dry time and cure time
Recommended Uses
Brick
Concrete
EFIS or Cement Plaster
Masonry Block
Stucco
Wood
Clear protection on murals and painted
vertical surfaces
Repellent of oil, gas, and other uids
Coverage Rates* (Theoretical)
*Extremely porous surfaces may require multiple coats
Substrate Sq Ft / Gallon
Porous Surface 200-300
Dense Surface 100-150
Description U/M Code
Clear-Seal Acrylic High Gloss 1 Gallon CU-0101
Urethane Quick Cure 2 Ounce SP-1300
Clear-Seal Acrylic High Gloss 5 Gallon CU-0105
Urethane Quick Cure 10 Ounce SP-1305
Clear-Seal Acrylic Low Gloss 1 Gallon CU-0201
Urethane Quick Cure 2 Ounce SP-1300
Clear-Seal Acrylic Low Gloss 5 Gallon CU-0205
Urethane Quick Cure 10 Ounce SP-1305
Rainguard
®
Clear-Seal Acrylic
Page 2 of 3Customer Service Help-Line 800.272.4647 RainguardPro.com
Application
1. Clear-Seal Acrylic Urethane Sealer should be
applied using either brush, t-bar, lamb’s wool
applicator, or most pump-up sprayers. We
do not recommend using a roller to apply, as
this may allow too much air, causing bubbles
to stay in the lm.
2. At time of application, moisture content of all
surfaces should be 30% or less as measured
with an electronic moisture meter.
3. Establish that air, surface and material
temperatures are above 40°f (4.4°C) and
at least 5°f above the dew point prior to
painting. Do not apply at temperatures below
40°f or when temperatures are expected
to drop below 40°f within 48 hours of
application. Do not apply if rain, snow, or
lower temperatures are expected within 48
hours. Do not apply if relative humidity is
greater than 80%.
4. Allow at least 1 hour or until tack-free before
applying a second coat.
Warranty
The information contained herein is offered in
good faith and is believed to be accurate. To be
eligible for a Rainguard Warranty the following
must occur:
1. A site visit must be conducted by an employee
or agent of Rainguard and a Field Inspection
Report completed.
2. A Warranty Application must be fully
completed by the applicator.
3. Field Inspection Report, Warranty Application,
and a copy of the distributor’s invoice must be
submitted to and approved by Rainguard.
This material is only warranted when applied in
accordance with the manufacturer’s guidelines
and warranty procedures. Without adherence to
these specic guidelines, no expressed or implied
warranty of this product is given. Please contact
Rainguard for additional information.
Inspection
Surface must be clean, dry, and free of grease,
paint, oil, dust, curing agents, or any foreign
material that will prevent proper adhesion. The
surface should be porous and be able to absorb
water. Relative humidity in the surface should
be below 80% (per ASTM F-2170). All moisture
should be kept away a minimum of 48 hours
before application and a min. of 48 hours after
installation. This includes sprinklers, rain, fog,
dew, etc.
Drying Time
Wait 24 Hours before opening up to light to
moderate trafc, and 72 Hours before heavy trafc.
Limitations
Do not apply in temperatures below 50°F or
above 90°F.
Do not apply on damp or moist surface as it
will whiten and may cause delamination.
Do not allow any Rainguard products to freeze.
Prior to coating previously sealed surfaces,
test a small area for adhesion.
Ok for use as an Industrial Maintenance
Coating, Concrete Masonry Sealer, or Floor
Coating, anywhere in the United States,
including the South Coast Air Quality
Management District (SCAQMD).
Please become familiar with local Air Quality
laws and regulations prior to applying this
coating. Rainguard bears no responsibility for
improper usage.
Test Panel
Always apply material to a mock wall or test panel.
Test wall or actual surface area to determine
acceptable color, surface porosity, application
rates and methods before starting general
application. It is the duty of the applicator to do a
test area to determine the surface is prepared for
general application of this coating. This adhesion
test can be done by applying a sample in an
inconspicuous area. Allow the sample to dry
and cure. Then cut the coating in a grid pattern
with vertical and horizontal lines cut into the lm.
Then place tape over the cut grid lines and wait
several minutes. Pull the tape up, if any material
delaminates, the surface is not properly prepared
for general application. If the sample is not altered
after removing the tape, the surface is sufciently
prepared for general application.
Precautions
Rainguard recommends the use of slip-resistant
aggregate in all coating or ooring systems that
may be exposed to wet, oily or greasy conditions.
These aggregates can be incorporated into the
materials using different methods to achieve
varying proles and degrees of slip-resistance.
However, textured surfaces can be slippery under
certain conditions. This type of activity on the
ooring surface, maintenance procedures and
type of footwear may all be factors to consider
when deciding the degree of slip-resistance
needed for given area. Rainguard or its sales
agents will not be responsible for injury incurred
in a slip and fall situation. It is the end users’
responsibility to provide for their own safety and to
determine the suitability of these coatings for their
particular application.
Rainguard
®
Clear-Seal Acrylic
Page 3 of 3Customer Service Help-Line 800.272.4647 RainguardPro.com
Material Type Water Based Urethane
Volume Solids 31%
Color of Material Of-White Emulsion in can
Odor Slight Latex Smell
V.O.C. <50 g/L V.O.C. Compliant
Gloss Level 20 - 25 @ 60°
Flash Point Non-Flammable
pH Value Approximately 7.5
Viscosity 9.6 Seconds No. 4 Ford Cup
Weight Approximately 8.5 lbs./Gal.
Surface Dry/Recoat Approx. 1 Hour
Full Chemical Cure 24-72 Hours
Technical Data
  • Page 1 1
  • Page 2 2
  • Page 3 3

RAIN GUARD CU-0205 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI