8
:
CREDA HEATING
MILLBROOK HOUSE, GRANGE DRIVE, HEDGE END, SOUTHAMPTON, SO30 2DF
UK - TEL: 0844 879 3588 / FAX: 0844 879 3583 / Website: www.credaheating.co.uk
R.O.I. - TEL: 01 842 4833
We offer a technical advisory service on the telephone:
RING 0844 879 3588 (UK) or 01 842 4833 (R.O.I)
GUARANTEE AND CONTACT DETAILS
(A4) Leaflet No. 581-2143-08a
GUARANTEE
Terms and Conditions for UK (outside UK contact your local distributor)
In the unlikely event of a product breakdown during the guarantee period you should
contact our Service and Repair Helpline who will be able to assist with the repair and
advise of the best course of action to be taken.
Please DO NOT remove the product prior to making this call as this may invalidate your
guarantee.
Service and Repair Tel: 0844 879 3588 (UK) or 01 842 4833 (R.O.I)
We guarantee this product for a period of 12 months from the date of purchase.
Within the guarantee period we will resolve, free of charge, any manufacturing defects in the product
resulting from faulty workmanship or material on condition that:-
a) The product has been correctly installed and commissioned in accordance with our instructions and
is being used on the supply circuit or voltage printed on the rating plate.
b) The product has been used in accordance with these instructions and has not been tampered with
or otherwise subject to misuse, neglect or accident.
c) The product has not been taken apart, modified or repaired except by a person authorised by us.
d) Evidence of the date of purchase in the form of an invoice or receipt will be required in order to
qualify under the terms of this guarantee.
e) For the service work to be undertaken free of charge, the work must only be undertaken by us,
or our approved agents.
f) Service under guarantee has no effect on the expiry date.
The guarantee on any exchanged parts or product ends when the original guarantee period ends.
EXCLUSIONS
This guarantee DOES NOT cover damage or defects arising from poor or incorrect installation,
improper use or lack of maintenance.
It is the responsibility of the installer to check that the installation parameters meet the requirements
of the products, and any relevant regulations.
If we are called out to a fault, which is subsequently identified as being an installation fault, we will
make a charge, it is important that the routine checks are completed before calling us out, as many
issues can be simply diagnosed and resolved.
A charge will be made where a call under the terms of the guarantee has been booked and a failure
was not product related, or an engineer arrives and is not able to gain access.
We make no guarantees as to response time for repairs.
We will endeavour to achieve the most timely response possible but while we indicate an average
response time, this should not be taken as a guarantee.
The guarantee applies to a repair or replacement (at our discretion) of the product subject to the
conditions above, and DOES NOT cover compensation for the loss of the product or consequential
loss of any kind.
This guarantee does not apply to the repair or replacement of accessories, isolating switches,
electrical cable, fuses and/or circuit breakers.
This
g
uarantee does not affect
y
our statutor
y
ri
g
hts.
INSTALLATION INSTRUCTIONS
Model 50816401
2
INTRODUCTION
THIS HEATER IS NOT EQUIPPED WITH A DEVICE TO CONTROL THE
ROOM TEMPERATURE. DO NOT USE THIS HEATER IN SMALL ROOMS
WHEN THEY ARE OCCUPIED BY PERSONS NOT CAPABLE OF LEAVING
THE ROOM ON THEIR OWN, UNLESS CONSTANT SUPERVISION IS
PROVIDED.
CHILDREN LESS THAN 8 YEARS OLD SHOULD BE KEPT AWAY FOR
THE APPLIANCE UNLESS CONTINUALLY SUPERVISED.
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS
AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR
MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE
IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION
CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND
UNDERSTAND THE HAZARDS INVOLVED.
CHILDREN SHALL NOT PLAY WITH THE APPLIANCE.
CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY
CHILDREN.
Thank you for purchasing a quality
Creda Sunfan Heater
manufactured in England.
Please take time to read this manual thoroughly to familiarise yourself with all
instructions, BEFORE beginning installation.
ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY
QUALIFIED PERSON.
The heater is intended for connection to fixed wiring.
Installation and wiring must be in accordance with the current edition of BS.7671
(the ‘IET Wiring Regulations’) in force at the time of installation.
Installations outside England and Wales must also conform to any local or
appropriate regulations in effect.
The protective fuse rating must NOT exceed 15A and a means for disconnection in
all poles MUST BE incorporated in the fixed wiring in accordance with the Wiring
Regulations.
This heater is intended for high level wall mounting in industrial/commercial
premises. However, it should NOT be used in corrosive atmospheres.
The heater should be fixed to a wall at a minimum height of 1.8m and there MUST
be a minimum gap of 150mm between the top of the heater and the ceiling.
Therefore the heater should NOT be installed in areas where the ceiling height is
less than 2.3m.
As a general rule, fan heating is NOT recommended for rooms greater than 5.0m
high. 7
9. The arm cover can now be replaced and retained with the two screws (see Diagram 2.0).
10. The
Sunfan Heater
should now be run to establish that it is working correctly and that it
is correctly aligned.
Should the heater require re-alignment, repeat section (8) & (9).
NOTE:- IF THE LOCKING SCREW IS NOT TOO TIGHT A SMALL AMOUNT OF
ADJUSTMENT SHOULD BE POSSIBLE WITHOUT REPEATING SECTIONS (8) & (9).
DCS Dual Remote Control Switch (Hot/Cold) Catalogue No. 82815906
Additional accessories and spare parts can be supplied by your local Creda distributor,
or on our website www.credaheating.co.uk
SCHEMATIC WIRING DIAGRAM
ADDITIONAL ACCESSORIES
6
The back nut on the cable gland should now be fully tightened to secure the supply
cable.
The terminal marked “L1” is required only if the hot/cold option is taken.
This will require a separate remotely mounted
“DCS Remote Dual Control Switch
(Catalogue No. 82815906)”
available from your local electrical wholesaler or distributor.
Wiring instructions are supplied with the control switch, and as one of the internal
connections in the
Sunfan Heater
will require re-location, this work should only be carried
out by a competent electrician.
8. The
Sunfan Heater
can now be pointed in the required direction by slackening the locking
screw, aligning the heater and re-tightening the locking screw (see Diagram 2.6).
WARNING:
DO NOT SWITCH THE HEATER ON BEFORE REPLACING THE ARM
COVER.
3
PROTECTION
If the heater is to be installed near an adjacent wall, the heater should be parallel
to, or angled away from it, and there should be a minimum gap of 300mm
between the adjacent wall and any part of the heater (see Diagram 1.0).
The heater MUST NOT be mounted immediately below a fixed electrical socket
outlet, neither should it be directed at any surface nearer than 1.5m.
This heater is protected by two thermal cut-outs.
TC1 being factory re-settable will operate only in the event of a major problem such as fan
blades being stalled.
TC2 is a cyclic device and will protect the heater in the event of the airflow being obstructed.
TC2 will reset when the fault condition has been rectified.
This heater is designed for a long, maintenance free, service life.
The motor is fully enclosed and should require no attention. However, if the heater is
located in a very dusty environment, it is recommended that any build-up of debris is
removed periodically.
MAINTENANCE
4
1. Remove the two screws from the arm cover.
Remove the arm cover (see Diagram 2.0).
2. Pull the wall plate down and away.
3. Return the
Sunfan Heater
to its box for safe
keeping, retaining the wall plate.
4. Use the wall plate as a template to mark out, drill and wall plug the three fixing holes.
See Diagram 1.0 for minimum clearance from floor, walls and ceiling.
Make sure that the wall plate is vertical.
Note:
The heater will accept cable entry from the top, bottom or rear.
If the rear cable entry is to be used, the cable gland can be discarded.
If either top or bottom entry is required use a knife or similar sharp tool to remove the
thin web of material in the threaded part of the appropriate end of the wall plate.
Alternatively, the gland can be screwed into the required end and tightened with an
appropriate spanner which will result in the thin web of material being removed.
5. Offer the wall plate to the wall and attach with TWO No.10 x 1.5” (or longer) round head
screws in holes A and B only.
DO NOT fix screw in hole C at this stage (see Diagram 2.3).
INSTALLING THE HEATER
5
6. With the wall plate firmly attached to the wall, latch the heater to the wall plate by
pushing back and down. Secure the heater to the wall/wall plate using a third
No.10 x 1.5” (or longer) round head screw through hole C (see Diagram 2.4).
7. Make sure the mains electricity supply is off.
The
Sunfan Heater
can now be connected to a suitable single-phase electrical supply
using appropriate cable.
If either top or bottom cable entry is required, fit the cable gland in the appropriate
threaded end of the wall plate.
If rear cable entry is required, the cables should project through the hole at the lower
edge of the wall plate.
Pass the twin cable through the cable gland and connect the brown insulated cable to the
terminal marked “L” on the terminal block.
Connect the blue insulated cable to the terminal marked “N” on the terminal block (see
Diagram 2.5).
WARNING:
IT IS MOST IMPORTANT TO ENSURE THAT THE SCREWS IN THE
TERMINAL BLOCK ARE FULLY TIGHTENED.
FAILURE TO DO SO COULD RESULT IN THE CONNECTION
OVERHEATING AND CAUSE DAMAGE TO THE APPLIANCE.