VDO Dayton PN 3000 Owner's manual

Type
Owner's manual
Page 1 of 2
Installation Manual
System Software
New System Software for PN 3000
Version C40-070731r1
Siemens VDO Trading GmbH • Executive Board: Christoph Maximilian Eisenhardt, Ekkehard Klautke, Registered office: Frankfurt am Main • Commercial registry: Frankfurt am Main,
HRB 54523, Office address: Kruppstraße 105, 60388 Frankfurt/Main, Tel: +49 69 40805-0, Postal address: Siemens VDO Trading GmbH, P.O.Box 62 01 27, 60350 Frankfurt/Main
How to perform the update
The files required for the update are stored as compressed data in a Zip file for free download from our internet presence.
Once unpacked the files provide a so-called card image which shall be copied to an empty SD card.
Please follow the below-mentioned steps:
Download the file corresponding to your System from the Internet (Update_PN3000_070731.zip) to the HDD of your
computer
o Extract the zip archive and copy all files 1:1 onto an empty SD card (do not add or leave out any files)
Note: Do not use other decompression software than WinZip since it may cause errors. If necessary, format the SD card
with option Format "FAT". Before formatting make sure that there are no more files on the SD card which you still
want to use later on. Minimum required capacity is 128 MB, max. 2 GB
Connect the PN 3000 to the 12 / 24 respectively 110 / 230 volt power supply
Switch off the PN 3000 by pressing the on / off button for longer than 3 seconds
Take out the SD Card containing the map data and insert the update SD Card
NOTE: The write protection of the update SD card must be disabled (unlock)
Switch on the PN 3000 by pressing the on / off button for longer than 3 seconds
The software update starts automatically and will take about 4 minutes
The update has finished when both bars of the SD upgrade screens shows 100%
Switch off the PN 3000 by pressing the on / off button for longer than 3 seconds
Note: The "Exit- button" in the SD Upgrade screen does not work!
Take out the SD card and insert the map data SD Card again
Page 2 of 2
Switch on the PN 3000 by pressing the on/off button for longer than 3 seconds. If this does not work, please press the reset
button of the PN 3000
The update process is now finished. PN 3000 System identification should show now GUI C40-070731r1
Improvements:
Improved TMC behaviour
Optimized period time between muting and voice output
  • Page 1 1
  • Page 2 2

VDO Dayton PN 3000 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI