Lionel Double Signal Bridge Owner's manual

Type
Owner's manual

Lionel Double Signal Bridge is a Plug-Expand-Play accessory that provides reliable operation and draws minimal power. It's compatible with AC and DC power and features low voltage LEDs for energy efficiency. Installation is simple, with the option for permanent mounting, and it can be connected to FasTrack or Tubular Track using various methods. The signal bridge changes from green to red when a train enters the insulated block and back to green when the train leaves.

Lionel Double Signal Bridge is a Plug-Expand-Play accessory that provides reliable operation and draws minimal power. It's compatible with AC and DC power and features low voltage LEDs for energy efficiency. Installation is simple, with the option for permanent mounting, and it can be connected to FasTrack or Tubular Track using various methods. The signal bridge changes from green to red when a train enters the insulated block and back to green when the train leaves.

78-3174-250
4/21
Lionel
Double Signal Bridge
Owners Manual
Lionel
Double Signal Bridge
Owners Manual
2
Table of contents
Installing the Double Track Signal Bridge 3
Connecting the Signal Bridge to FasTrack 3-4
Connecting the Signal Bridge to Tubular Track 5
Connecting the Signal Bridge to 153IR Controllers 6
Lamp Replacement 7
Limited Warranty/Lionel Service 8
Thank you for your purchase of the Plug-Expand-Play Double Track Signal Bridge! This
accessory will provide years of reliable operation. This accessory is now equipped with
low voltage LEDs and designed to draw as little power as possible. This accessory is also com-
patible with both AC and DC power! Also included is the Lionel Plug-Expand-Play system, so
installation has never been easier!
Thank You!
Plug-Expand-Play
is revolutionary accessory system simplies the setup and operation of your
favorite accessories. Plug-Expand-Play accessories easily connect to your layout
for power using a standardized 3-pin cable that connects directly to a Plug-
Expand-Play Lock-on track section. ere are separate-sale cables that allow you
to expand your system to meet your needs.
The following Lionel marks are used throughout this Owner’s Manual and are protected under law. All rights
reserved.
Lionel®, Lockon®, FasTrack®, Plug-Expand-Play®
3
Installing the Double Track Signal Bridge
Connecting the Signal Bridge to FasTrack
The Double Track Signal Bridge is designed to stand up on its own without any mounting
hardware. There is, however, a mounting hole provided in both bases of the signal should
you decide to permanently mount it to your layout.
For simple operation with the Plug-Expand-Play system you will need two pieces of the
6-81317 Plug–Expand–Play FasTrack Accessory Activator Track Pack (sold separately).
The instructions below illustrate how to connect the Signal Bridge to this special section of
track. Simply repeat these steps to connect the signal to two independent insulated sections.
Once you have oriented the two 5” insulated tracks properly simply insert the Plug-
Expand-Play cable into the lock on track. When power is applied the green LED on the signal
bridge will illuminate. When the train enters the insulated block section the green LED will
turn off and the red LED will illuminate. The red LED will stay illuminated until the last car in
the train leaves the insulated block. At which time the red LED will turn off and the green
LED will turn on.
Figure 1. Connecting the signal bridge to Plug-Expand-Play Activator Track Packs
Signal Bridge
Note If you wish to extend the length of your insulated detection block you can additional 10”
sections of 6-12027 Accessory Activator Extender sections (sold separately). Place these
sections in between the two 5” insulated straight sections.
Using Plug-Expand-Play
Lock-on
5" track with
break
Break Break
5" track with
break
10" trackFasTrack FasTrack
3-pin male connector
4
Connecting the Signal Bridge to FasTrack continued
Using Standard FasTrack Wiring
You can clip off the Plug-Expand-Play connector on the end of the cable OR purchase two
6-82038 Plug-Expand-Play 8" Female cables (sold separately). e 6-82038 is also avail-
able through Lionel Customer Service. You will also need two of the FasTrack Accessory
Activation Packs (6-12029, sold separately).
The red wire connects to either the center rail of the track OR the “A” terminal on an accessory
transformer (the accessory transformer must be in phase with the track power supply). If you
use a DC power supply the red wire MUST connect to the positive DC rail or terminal (most
commonly the center rail).
The black wire connects to the grounded outside rail of the track OR the “U” terminal on an
accessory transformer (the accessory transformer must be in phase with the track power sup-
ply). If you use a DC power supply the black wire MUST connect to the negative DC rail or ter-
minal (most commonly the outside rail).
The white wire connects to the insulated outside rail of the track. When a train is present on
the insulated track the LEDs will change from an illuminated green LED to an illuminated red
LED. Once the train leaves the insulated block the red LED will turn off and the green LED will
illuminate again.
5" track with
break
5" track with
break
10" track
Break
Red wire
White wire
Black wire
FasTrack FasTrack
Break
Signal Bridge
3-pin male
connector
3-pin female connnector
8" 3-pin female pigtail (6-82038)
Note Connections are made
underneath the 10"
section of track.
Figure 2. Connecting the signal bridge to FasTrack
5
Connecting the Signal Bridge to Tubular Track
You can clip off the Plug-Expand-Play connector on the end of the cable OR purchase two
6-82038 PEP 8” Female cables (sold separately). The 6-82038 is also available through
Lionel Customer Service. Regardless of the direction you take the wiring is quite simple.
If you are using O gauge tubular track you will need two 6-12840 O Gauge Insulated Tracks
(sold separately).
If you are using O27 Tubular track you will need two 6-12841 O27 Gauge Insulated Tracks
(sold separately).
Follow the diagram if you choose to connect your signal to the track using CTC Lockons, oth-
erwise continue follow the instructions below;
Connect the red wire to either the center rail of the track you are connecting the signal to OR
to constant voltage accessory power (hot; A, B, C or D). Connect the black wire to the non-in-
sulated outside rail OR to constant voltage accessory power (ground; U). The white wire con-
nects to the insulated outside rail (isolated ground).
3-pin male
connector
3-pin female
connnector
8" 3-pin female pigtail
(6-82038)
10" Tubular
track
10" Tubular
track
6-12840 (O gauge insulated track)
OR
6-12841 (O27 gauge insulated track)
CTC lock-on
Insulating pin
Insulating
pin CTC lock-on
Red wire
Red wire
White wire
White wire
Black wire
Black wire
Figure 3. Connecting the signal bridge to tubular track
Signal Bridge
6
Connecting the Signal Bridge to 153IR Controllers
You can clip off the Plug-Expand-Play connector on the end of the cable OR purchase two
6-82038 PEP 8” Female cables (sold separately). The 6-82038 is also available through
Lionel Customer Service. Regardless of the direction you take the wiring is quite simple.
Signal Bridge
ACC
POWER
ACC
POWER
ACC
GROUND
ACC
GROUND
NO NO
NC NC
3-pin male
connector
3-pin female
connnector
Red wire Red wire
White wire White wire
Black wire Black wire
8" 3-pin female pigtail
(6-82038)
Figure 4. Connecting the signal bridge to 153IR controllers
7
Lamp Replacement
Your Signal Bridge is equipped with LEDs which should last the life of the product. In the
event you need to replace the LED on your Signal Bridge, please contact your nearest
Lionel Service Center or Lionel Service.
©2021 LIONEL L.L.C.
6301 Performance Dr., CONCORD, NC 28027
UNITED STATES OF AMERICA
PRINTED IN CHINA
Lionel Limited Warranty Policy & Service
T
his Lionel product, including all mechanical and electrical components, moving parts, motors and structural components, with the exception of LIGHT BULBS,
LED’s & TRACTION TIRES are warranted to the original owner-purchaser for a period of one year from the original date of purchase against original
defects in materials or workmanship when purchased through a Lionel Authorized Retailer*.
This warranty does NOT cover the following:
• Normal wear and tear
• Light bulbs or LEDs
• Defects appearing in the course of commercial use
• Damage resulting from abuse/misuse of the product
Transfer of this product by the original owner-purchaser to another person voids this warranty in its entirety. Modification of this product in any way; visually,
mechanically or electronically, voids the warranty in its entirety.
Any warranted product which is defective in original materials or workmanship and is delivered by the original owner-purchaser (this warranty is non-
transferrable) to Lionel LLC or any Lionel Authorized Service Station MUST be accompanied by the original receipt for purchase (or copy) from an Authorized
Lionel Retailer*, will at the discretion of Lionel LLC, be repaired or replaced, without charge for parts or labor. In the event the defective product cannot be repaired,
and a suitable replacement is not available, Lionel will offer to replace the product with a comparable model (determined by Lionel LLC), if available. In the event a
comparable model is not available the customer will be refunded the original purchase price (requires proof of purchase from the Authorized Lionel Retailer* it was
originally purchased). Any products on which warranty service is sought must be sent freight or postage prepaid (Lionel will refuse any package when postage is due).
Transportation and shipping charges are not covered as part of this warranty.
NOTE: Products that require service that do not have a receipt from an LIONEL AUTHORIZED RETAILER* will be required to pay for all parts
required to repair the product (labor will not incur a charge) providing the product is not older than 3 years from date of manufacture and is
within 1 year from date of purchase. A copy of the original
sales receipt is required.
In no event shall Lionel LLC be held liable for incidental or consequential damages.
Instructions for Obtaining Service
I
f service for this Lionel LLC product is required; bring the item, along with your DATED sales receipt and completed warranty information (at the bottom of this
page) to the nearest Lionel Authorized Service Station. Your nearest Lionel Service Station can be found by calling 1-800-4-LIONEL or by accessing the website at
www.lionel.com.
If you prefer to send your Lionel product directly to Lionel, for repair you must FIRST call 1-800-4LIONEL (1-800-454-6635) or write to Lionel Customer Service,
6301 Performance Drive, Concord, NC 28027. Please have the Lionel product number, the date of original purchase, the dealer where the item was purchased and what
seems to be the problem. You will receive a return authorization (RA) number to ensure your merchandise will be properly tracked and handled upon receipt at Lionel
LLC.
Once you have your Return Authorization (RA) number, make sure the item is packed in its original Styrofoam inner container which is placed inside the original outer
display box (this will help prevent damage during shipping and handling). This shipment MUST be prepaid and we recommend that it be insured with the carrier of
your choice.
Please make sure you have followed all of the above instructions carefully before returning any merchandise for service. You may choose to have your product repaired
by one of Lionel LLC’s Authorized Service Stations after its warranty has expired. A reasonable service fee should be expected once the product warranty has expired.
Warranty Information
P
lease complete the information below and keep it, along with your DATED ORIGINAL SALES RECEIPT. You MUST present this form AND your DATED
SALES RECEIPT when requesting warranty service.
*A complete listing of Lionel Authorized retailers can be found by calling 1-800-4-LIONEL or by visiting our website at www.lionel.com.
Products that are more than 3 years old, from date of manufacture, are not applicable for warranty coverage, even if they have never been sold prior to this date. (Under
no circumstance shall any components or labor be provided free of charge.)
Name _________________________________________________________________________
Address ________________________________________________________________________
Place of Purchase _________________________________________________________________
Date of Purchase __________________________________________________________________
Product Number __________________________________________________________________
Product Description ________________________________________________________________
S
ome states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you
specific legal rights and you may have other rights which vary from state to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Lionel Double Signal Bridge Owner's manual

Type
Owner's manual

Lionel Double Signal Bridge is a Plug-Expand-Play accessory that provides reliable operation and draws minimal power. It's compatible with AC and DC power and features low voltage LEDs for energy efficiency. Installation is simple, with the option for permanent mounting, and it can be connected to FasTrack or Tubular Track using various methods. The signal bridge changes from green to red when a train enters the insulated block and back to green when the train leaves.

Ask a question and I''ll find the answer in the document