Frieze
Block
Rafter
For houses with open sots, Eave Vents t
snugly between Rafters, replacing the
wooden 2 x 6 (or 2 x 4) Frieze Block. If the
vent doesn’t take up the whole space or a
rough opening hole can be cut in the
Frieze Block. Nail through the side anges
to secure the vent to the rafters.
Eave Vents have very sharp edges. Use gloves to prevent injury. This product is not recommended for direct contact with treated lumber.
Working above grade is inherently dangerous, be sure that proper fall protection measures are in place. When working with power tools and sheet metal,
gloves and eye protection are absolutely required.
These basic installation guidelines are for use with typical or standard applications. It is always recommended to seek advice from a licensed professional,
and to check with your local building inspector or building permit office for approvals and possible variations that may apply.
EAVE VENTS
INSTALLATION GUIDELINES
EV145
EV223
EV614
EV622
Size N.F.V. Part # Rough Opening Gross Size
14 in. x 5 in. - 1/4 mesh - Stucco Flange - Galvanized 44 sq. in. EV145 14.75 in. x 4.75 in. 14.5 in. x 4.5 in.
22 in. x 3 in. - 1/4 mesh - Stucco Flange - Galvanized 39 sq. in. EV223 22.625 in. x 3.75 in. 22.375 in. x 3.5 in.
14 in. x 6 in. - 1/4 mesh - Regular Flange - Galvanized 44 sq. in. EV614 14.75 in. x 5.75 in. 14.5 in. x 5.5 in.
22 in. x 6 in. - 1/4 mesh - Regular Flange - Galvanized 71 sq. in. EV622 22.75 in. x 5.75 in. 22.5 in. x 5.5 in.