Document 6321102-01, Ver. 1 Rev. 0
0
August 1998
0
PowerStor L500 Library
Unpacking Instructions
Introduction....................................................................................................3
Purpose.....................................................................................................3
Library Configurations ..........................................................................3
Selecting an Installation Location ...............................................................4
Floor Space...............................................................................................4
Overhead Clearance...............................................................................5
Surface Strength and Inclination..........................................................5
Power and Grounding ...........................................................................5
Environmental Specifications ...............................................................5
Receiving the Library....................................................................................6
Unpacking the Library..................................................................................7
Uncrating the Rack-Mount Kit..............................................................7
Installing the Rack-Mount Kit...............................................................7
Uncrating the Library.............................................................................8
PowerStor L500 Library Unpacking Instructions
Document 6321102-01, Ver. 1 Rev. 0
August 1998
2
Introduction 3
PowerStor L500 Library Unpacking Instructions
0
Document 6321102-01, Ver. 1 Rev. 0
0
August 1998
0
Introduction
0
Purpose
0
This document explains how to unpack the PowerStor L500 library
properly. Once the library is unpacked and moved to the desired
installation location, set up the library using the instructions in the
PowerStor L500 Library Users Guide.
The PowerStor L500 library is shipped in packing materials designed
to protect it from damage during transit. By following these
instructions, you help ensure that the library will continue to be
safeguarded after it arrives at the installation site.
Library
Configurations
0
The PowerStor L500 library is shipped in two configurations:
Stand-alone (tower) configuration
Rack-mount configuration
Figure 1 PowerStor L500
Library Configurations
TK00001a
TK00002a
Stand-alone configuration Rack-mount configuration
Document 6321102-01, Ver. 1 Rev. 0
August 1998
4 Selecting an Installation Location
Selecting an Installation Location
1
When selecting an installation location for the library, consider the
following:
Floor space
Overhead clearance
Installation surface strength and inclination
Power and grounding
Environmental specifications
Floor Space
1
Figure 2 shows the floor space requirements for setting up and
operating the stand-alone library.
Figure 2 Floor Space
Requirements (Stand-
Alone Library)
Figure 3 shows the floor space requirements for setting up and
operating the rack-mount library.
10.5 inches
20.0 inches
Front
Back
(26.67 cm)
(50.8 cm)
Document 6321102-01, Ver. 1 Rev. 0
August 1998
Selecting an Installation Location 5
Figure 3 Floor Space
Requirements (Rack-
Mount Library)
Overhead Clearance
3
The height of the stand-alone library is 18.0 inches (45.72 cm). The
height of the rack-mount library is 7.0 inches (17.78 cm).
To remove and replace the library enclosure, you will need an
overhead clearance slightly greater than the height of the library.
Surface Strength and
Inclination
3
The library and rack must be placed on a clean, level surface. If the
library will be placed on a desk or table, make sure it is sturdy enough
to support the library’s weight (76 lbs/35 kg).
Power and
Grounding
3
The electrical ratings for the library are 100 to 120/200 to 240 VAC,
50/60 Hertz.
Environmental
Specifications
3
The installation location should meet the following environmental
specifications.
Temperature: 50°F to 104°F (10°C to 40°C)
Relative humidity: 20% to 80% noncondensing
Humidity gradient: 10%/hour
Dry bulb temperature: 50°F to 104°F (10°C to 40°C)
Wet bulb temperature: 77°F (25°C)
Temperature gradient: 19.8°F/hour (11°C/hour) across the range
Temperature shock: 18°F (10°C) over two minutes
Altitude: -500 to 30,000 feet (-152.4 to 9144 meters)
17.75 inches
(45.09 cm)
20.0 inches
(50.8 cm)
Front
Back
Document 6321102-01, Ver. 1 Rev. 0
August 1998
6 Receiving the Library
Receiving the Library
3
When receiving the library from the shipper, receive the unit as close to
the installation location as possible.
Inspect the shipping pallet and carton for damage that may have
occurred during shipment. Report any damage to the shipper
immediately.
Document 6321102-01, Ver. 1 Rev. 0
August 1998
Unpacking the Library 7
Unpacking the Library
3
The unpacking instructions vary depending upon whether you
received a stand-alone or rack-mount library. If you received a stand-
alone library, you should have only one shipping carton. Follow the
instructions in “Uncrating the Library” on page 8 to unpack the
library.
If you received the rack-mount library, you should have two shipping
cartons. The large carton contains the library, and the smaller carton
contains the rack-mount kit.
To unpack and install the rack-mount library, you must:
Uncrate the rack-mount kit and verify its contents (see “Uncrating
the Rack-Mount Kit”)
Install the rack-mount kit in the rack (see “Installing the
Rack-Mount Kit”)
Uncrate the library and place it in the rack (see “Uncrating the
Library” on page 8)
Uncrating the
Rack-Mount Kit
3
Cut the packing tape at the top of the shipping carton and unpack the
rack-mount kit. Before installing the rack-mount kit in the rack,
compare the contents of the carton with the packing list inside the
shipping carton.
Installing the
Rack-Mount Kit
3
Install the rack-mount kit in the rack, referring to drawing provided in
the shipping carton.
Document 6321102-01, Ver. 1 Rev. 0
August 1998
8 Unpacking the Library
Uncrating the Library
3
To uncrate a PowerStor L500 library:
Figure 4 Removing the
Shipping Carton from the
Pallet
Step Action
1
Cut the straps that secure the shipping carton to the pallet (see
figure 4).
2
Lift the carton off of the pallet.
Note:
The library weighs 76 lbs (35 kg). Two people should perform any
procedure that involves lifting or moving the library.
3
Open the top of the shipping carton by carefully cutting the
packing tape.
TK00003a
Straps
Pallet
Packing tape
Shipping carton
Document 6321102-01, Ver. 1 Rev. 0
August 1998
Unpacking the Library 9
Figure 5 Removing the
Accessories Boxes
Step Action
4
Remove the two accessories boxes from the carton (see figure 5).
One of these boxes is empty. The other box contains the
accessories kit.
TK00004a
Accessories boxes
Document 6321102-01, Ver. 1 Rev. 0
August 1998
10 Unpacking the Library
Figure 6 Removing the
Library from the Shipping
Carton
Step Action
5
Remove the packing foam from the top of the library (see
figure 6).
6
With two people lifting the library, remove it from the shipping
carton.
7
Remove the library from the shipping bag.
8
Place the library in the installation location. If it is a rack-mount
library, place it in the rack.
TK00005a
Packing foam
Shipping bag
Library
Document 6321102-01, Ver. 1 Rev. 0
August 1998
Unpacking the Library 11
The library is now unpacked. Refer to the PowerStor L500 Library Users
Guide for information about connecting the library cables and
operating the library.
Caution: Do not attempt to open the front doors of the library when
the library is powered off. These doors can be opened only
when the unit is powered on.
Document 6321102-01, Ver. 1 Rev. 0
August 1998
12 Unpacking the Library
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Quantum L500 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI