JBSYSTEMS ANDROMEDA DMX Owner's manual

Category
Stroboscopes & disco lights
Type
Owner's manual
Version: 1.0
WWW.BEGLEC.COM
Copyright © 2009 by BEGLEC comm.v.a.
‘t Hofveld 2 ~ B1702 Groot-Bijgaarden ~ Belgium
Reproduction or publication of the content in any manner, without express permission of the publisher, is prohibited.
Operation Manual
Mode d'emploi
Gebruiksaanwijzing
Bedienungsanleitung
Manual de instrucciones
Manual do utilizador
EN
FR
NL
DE
ES
PT
ENGLISH OPERATION MANUAL
JB SYSTEMS
®
1/30 ANDROMEDA DMX
OPERATION MANUAL
Thank you for buying this JB Systems
®
product. To take full advantage of all possibilities and for your own
safety, please read these operating instructions very carefully before you start using this unit.
FEATURES
This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.
This device has been designed to produce decorative effect lighting and is used in light show systems.
Incredible LED based double moonflower!
Thanks to 1channel DMX control, the unit can be switched on/off by any DMX-controller.
Uses 92 high power LEDs (32 red + 30 green + 30 blue):
Extremely brilliant colors compared to effects with halogen lamps
More dynamic effects compared to effects based on halogen lamps
No moving parts (motors) inside!
No lamp replacements!
LEDs with an extremely long lifespan.
Virtually no heat production
Very low power consumption
Lightweight (no lamp transformers needed)
Built-in lightshows (triggered by sound)
Perfect for small applications: discos, clubs, mobile DJs, home,
BEFORE USE
Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.
Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary
for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.
Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.
Check the contents:
Check that the carton contains the following items:
Operating instructions
Andromeda DMX unit
SAFETY INSTRUCTIONS:
CAUTION: To reduce the risk of electric shock, do not remove the top cover.
No user-serviceable parts inside. Refer servicing to qualified service
personnel only.
The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use
or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instructions in the literature accompanying this
appliance.
This symbol means: indoor use only.
This symbol means: Read instructions.
To protect the environment, please try to recycle the packing material as much as possible.
CAUTION
ENGLISH OPERATION MANUAL
JB SYSTEMS
®
2/30 ANDROMEDA DMX
A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears after some
minutes.
To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it
into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even
cause damages.
This unit is for indoor use only.
Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign object
enters the unit, immediately disconnect the mains power.
Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture must be fixed
at least 50cm from surrounding walls.
Don’t cover any ventilation openings as this may result in overheating.
Prevent use in dusty environments and clean the unit regularly.
Keep the unit away from children.
Inexperienced persons should not operate this device.
Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.
The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare hands during its operation.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
Allow the device about 10 minutes to cool down before replacing the bulb or start servicing.
Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
The electrical installation should be carried out by qualified personal only, according to the regulations for electrical
and mechanical safety in your country.
Check that the available voltage is not higher than the one stated on the rear panel of the unit.
The power cord should always be in perfect condition. Switch the unit immediately off when the power cord is
squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
Never let the power-cord come into contact with other cables!
This fixture must be earthed to in order comply with safety regulations.
Don’t connect the unit to any dimmer pack.
Always use an appropriate and certified safety cable when installing the unit.
In order to prevent electric shock, do not open the cover. Apart from the lamp and mains fuse there are no user
serviceable parts inside.
Never
repair a fuse or bypass the fuse holder.
Always
replace a damaged fuse with a fuse of the same type and
electrical specifications!
In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
The housing and the lenses must be replaced if they are visibly damaged.
Please use the original packing when the device is to be transported.
Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
Important:
Never look directly into the light source! Don’t use the effect in the presence of persons suffering from
epilepsy.
DESCRIPTION:
1. Optical lenses + scan mirrors
2. Hanging bracket with 2 knobs on both sides to
fasten the unit and a mounting hole to fix a
mounting hook.
3. Mains input with IEC socket and integrated fuse
holder, connect the supplied mains cable here.
4. Microphone
5. DMX input: 3pin male XLR-connector used to
connect universal DMX-cables. This input receives
instructions from a DMX-controller.
6. DMX output: 3pin female XLR-connector used to
connect the Andromeda DMX with the next unit in
the DMX chain.
7. DIP switches, to set the DMX-starting address.
ENGLISH OPERATION MANUAL
JB SYSTEMS
®
3/30 ANDROMEDA DMX
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don’t cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation in DMX-mode:
The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
“daisy chain” your DMX controller and all the connected units with a good quality balanced cable.
Both XLR-3pin and XLR-5pin connectors are used, however XLR-3pin is more popular because these
cables are compatible with balanced audio cables.
Pin layout XLR-3pin: Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
Pin layout XLR-5pin:
Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+) ~ Pins4+5 not used.
To prevent strange behavior of the light effects, due to interferences, you must use
a 90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this
simply won’t work!
Make sure that all units are connected to the mains.
Each light effect in the chain needs to have its proper starting address so it knows
which commands from the controller it has to decode. In the next section you will learn how to set the
DMX addresses.
ENGLISH OPERATION MANUAL
JB SYSTEMS
®
4/30 ANDROMEDA DMX
How to set the DIP-switches to obtain the right starting address:
Each of the first 9 DIP-switches correspond to a certain DMX-value:
DIP #1 #2 #3 #4 #5 #6 #7 #8 #9 #10
Value 1 2 4 8 16 32 64 128 256
Slave inversion not
used in DMX-mode
You can combine the values of these switches to become any starting address between 1 and 512:
Begin address = 01 switch 1=ON values: 1
Begin address = 05 switch 1+3=ON values: 1+4 = 5
Begin address = 09 switch 1+4=ON values: 1+8 = 9
Begin address = 13 switch 1+3+4=ON values: 1+4+8 = 13
Begin address = 62 switch 2+3+4+5+6=ON values: 2+4+8+16+32 = 62
OPERATING INSTRUCTIONS
1. Standalone 1unit:
Just connect the unit to the mains and put on some music. The unit will start working automatically to the
rhythm of the music.
2. DMX-mode:
When the units are connected in DMX-mode, they can be controlled using the following
DMX-chart:
Always unplug the unit when it is not used for a longer time or before replacing the bulb or
start servicing.
In the event of serious operating problems, stop using the fixture and contact your dealer
immediately.
Important: Never look directly into the light source! Don’t use the effect in the presence of
persons suffering from epilepsy.
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during
servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

JBSYSTEMS ANDROMEDA DMX Owner's manual

Category
Stroboscopes & disco lights
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI