9 Technische Daten
Weitere technische Daten entnehmen Sie bitte dem Online-Katalog
unter www.aventics.com.
English
1 About this Documentation
Documentation validity
These instructions contain important information on the safe and
proper installation and operation of the series ST6-ATEX sensor
(R412022854, R412022856, R412022860, R412022864).
Related documents
The ST6-ATEX sensor is a system component.
O Also follow the system manufacturer’s system documentation.
Presentation of information
Safety instructions
In this document, there are safety instructions before the steps
whenever there is a danger of personal injury or damage to the
equipment. The measures described to avoid these hazards must
be observed.
Safety instructions are set out as follows:
Allgemein
Spannung 10 bis 30 V DC
Schaltstrom 100 mA
Umgebungstemperatur –20 °C bis +50 °C
Kabellänge R412022854 3 m
R412022856 5 m
R412022864 0,3 m/M12
R412022860 0,3 m/M8
ATEX
Zone 2 II 3G Ex nA IIC T4 Gc X
Zone 22 II 3D Ex tc IIIC T135°C Dc X
SIGNAL WORD
Hazard type and source
Consequences
O Precautions
Warning signs and signal words have the following meanings:
Symbols
2 Notes on Safety
About this chapter
The product has been manufactured according to the accepted
rules of safety and current technology. Even so, there is a risk of
injury or damage if the following general safety instructions and
the specific warnings given before the steps in this documentation
are not observed.
O Read these instructions completely before working with the
ST6-ATEX sensor.
O Keep these instructions in a location where they are accessible
to all users at all times.
O Always include the relevant operating instructions when you
pass the ST6 sensor on to third parties.
Intended use
O The ST6-ATEX sensor is only intended for industrial
applications.
O The pressure regulator may only be used within the limits
listed in the technical data.
O The sensor is to be used to detect magnetic fields in explosive
areas.
Improper use
It is considered improper use if the ST6-ATETX sensor
W is used for any application not stated in these instructions or
W is used under operating conditions that deviate from those
described in these instructions.
Personnel qualifications
Assembly and commissioning require basic electrical and
pneumatic knowledge. Assembly and commissioning may
therefore only be carried out by qualified electrical or pneumatic
personnel or an instructed person under the direction and
supervision of qualified personnel. Qualified personnel are those
who can recognize possible hazards and institute the appropriate
safety measures, due to their professional training, knowledge,
and experience, as well as their understanding of the relevant
regulations pertaining to the work to be done. Qualified personnel
must observe the rules relevant to the subject area and have
qualifications according to the Technical Rules for Operational
Safety (TRBS 1203).
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
If this information is disregarded, the product cannot be
used or operated optimally.
AVENTICS | ST6 | R412024085-BAL-001-AC | Deutsch/English 3
General safety instructions
W Observe the regulations for accident prevention and
environmental protection in the country where the product
is used and at the workplace.
W Do not modify or convert the device.
W Only use the device within the performance range provided
in the technical data.
W The warranty will not apply if the product is incorrectly
assembled.
W Do not place any improper mechanical loads on the product
under any circumstances.
Safety instructions related to the product
and technology
On installation
W Make sure the relevant system component is not under
pressure or voltage before assembling the product or when
connecting and disconnecting plugs.
During operation
W Only commission the sensor after it has been completely
assembled, as well as correctly connected and tested.
W Observe the operating conditions and data printed on the
relevant sensor or stated on its rating plate.
W Do not disconnect plugs or lines when the sensor is under
voltage.
ATEX – information on explosion protection
ST6-ATEX sensors are certified and labeled according to the
enclosed declaration of conformity.
They can be used
W with gases, mists, or vapors in zone 2
W with flammable dust particles in zone 22
Explanations concerning identification
Due to the small size of the sensor, the ATEX identification
is located on a cable flag.
Year of manufacture of the sensor: The first two digits
in the 5-digit date code on the rating plate indicate the year
and the last two digits indicate the week.
II 3G Ex nA IIC T4 Gc X
II 3D Ex tc IIIC T135°C Dc X
The device will lose its Ex approval if these instructions are not
complied with!
3 Delivery Contents
W 1x ST6-ATEX sensor
W 1 set of operating instructions (R412024085)
Variants with M8 and M12 plugs:
W Cable with plug and removal protection clip
4 About This Product
The ST6-ATEX sensor is used to detect magnetic fields in explosive
areas.
Product identification
O Observe the product information on the product and
packaging.
5 Assembly and Commissioning
Sensor porting configuration
O Observe the Ex guidelines as per EN 60079-14.
O The installation of electrical devices must be carried out
in accordance with applicable national regulations and
performed or supervised by an electrical specialist
(in compliance with TRBS 1203 or equivalent).
O Compare the information on the device with the information
in the operating instructions before installation.
WARNING
Danger of an ignition source due to impermissible operating
conditions, connections, and parameters!
Operating the sensor under impermissible operating conditions
can result in an explosion.
O Observe the permissible operating conditions, in particular
the ambient temperature and the mechanical protection
for the device.
O The ST6-ATEX sensor is only intended for complete
installation in suitable T-slots.
O Note the limited temperature range for ATEX conditions.
O Do not disconnect the plug connectors and the connecting
cable from the sensor if it is under voltage.
O Only use approved M8 and M12 connecting cables from
the AVENTICS GmbH product offering.
O Observe the relevant Ex guidelines for installation,
maintenance, and repair, especially EN 60079-14.
1
4
3
+
R
L
BN
BU
BK
AVENTICS | ST6 | R412024085-BAL-001-AC | English 4
Français
1 A propos de cette documentation
Validité de la documentation
Ce mode d’emploi contient des informations importantes pour
installer et utiliser le capteur de série ST6-ATEX (R412022854,
R412022856, R412022860, R412022864) de manière sûre
et conforme.
Documentation supplémentaire
Le capteur ST6-ATEX est un composant d’installation.
O Respecter également la documentation d’installation
du fabricant.
Présentation des informations
Consignes de sécurité
Dans la présente documentation, des consignes de sécurité
figurent devant les instructions dont l’exécution recèle un risque
de dommages corporels ou matériels. Les mesures décrites pour
éviter des dangers doivent être respectées.
Les consignes de danger sont disposées de la manière suivante :
Les symboles d’avertissement et les mots-clés ont la signification
suivante :
Symboles
2 Consignes de sécurité
A propos de ce chapitre
Ce produit a été fabriqué conformément aux techniques les plus
modernes et aux règles de sécurité technique reconnues.
Des dommages matériels ou corporels peuvent néanmoins
survenir si les consignes de sécurité générales suivantes ainsi
que les avertissements précédant les consignes d’utilisation
contenus dans le présent mode d’emploi ne sont pas respectés.
O Lire entièrement et soigneusement ce mode d’emploi avant de
travailler avec le capteur ST6-ATEX.
MOT-CLE
Type et source de danger
Conséquences en cas de non-respect
O Mesure préventive contre le danger
AVERTISSEMENT
Signale une situation dangereuse susceptible d’entraîner
des blessures graves ou mortelles si le danger n’est pas évité.
ATTENTION
Signale une situation dangereuse susceptible d’entraîner
des blessures légères à modérées si le danger n’est pas évité.
En cas de non-respect de cette information, le produit
ne livrera pas sa performance optimale.
1. Fit the sensor into the T-slot (any mounting orientation).
2. Install the sensor protected against mechanical impact and UV
light (depending on the requirements/operating conditions).
3. Install cables with protection or provide for strain relief.
6 Care and Maintenance
The described sensors are maintenance-free.
7 Disposal
O Dispose of the product in accordance with the national
regulations in your country.
8 Troubleshooting
O Replace the sensor in the event of malfunctions or failure.
9 Technical data
Further technical data can be found in our online catalog at
www.aventics.com.
WARNING
Danger of explosion due to missing removal protection clip!
Exposed electrical connections are an ignition source
in explosive areas!
O With cables with M8 or M12 plugs, always assemble the
supplied removal protection clip over the plug connection.
CAUTION
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or voltage can lead to
injuries.
O Make sure that all relevant system parts are not under
pressure or voltage before assembly.
General
Voltage 10 to 30 V DC
Switching current 100 mA
Ambient temperature –20°C to +50°C
Cable length R412022854 3 m
R412022856 5 m
R412022864 0.3 m/M12
R412022860 0.3 m/M8
ATEX
Zone 2 II 3G Ex nA IIC T4 Gc X
Zone 22 II 3D Ex tc IIIC T135°C Dc X
AVENTICS | ST6 | R412024085-BAL-001-AC | English/Français 5
The data specified above only serve to
describe the product. No statements
concerning a certain condition or
suitability for a certain application can
be derived from our information. The
given information does not release the
user from the obligation of own
judgement and verification. It must be
remembered that our products are
subject to a natural process of wear
and aging.
An example configuration is depicted
on the title page. The delivered
product may thus vary from that in the
illustration.
Translation of the original operating
instructions. The original operating
instructions were created in the
German language.
R412024085-BAL-001-AC/2017-06
Subject to modifications. © All rights
reserved by AVENTICS GmbH, even
and especially in cases of proprietary
rights applications. It may not be
reproduced or given to third parties
without its consent.
AVENTICS GmbH
Ulmer Straße 4
30880 Laatzen, GERMANY
Phone +49 (0) 5 11-21 36-0
Fax: +49 (0) 511-21 36-2 69
www.aventics.com
info@aventics.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

AVENTICS Capteur, ST6 certifié ATEX Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI