MLis MLB-Z4001 User manual

Type
User manual
MLB-Z4001 Terminal User Guide 1 Rev 1.0
MLB-Z4001
Ethernet to 900 MHz
RF Modem
USER MANUAL
MLB-Z4001 Terminal User Guide 2 Rev 1.0
Information provided by Schmidt & Co., (HK) Ltd, (herein known as ‘the company’), is believed to
be accurate and reliable. However, the company assumes no responsibility for its use, nor any
infringement of patents or other rights of third parties, which may result from its use. No license is
granted by implication or otherwise under any patent rights of the company other than for circuitry
embodied in the company’s products. The company reserves the right to change the circuitry and
specifications at any time without notice. This document is subject to change without notice.
No part of this document may be reproduced or transmitted in any form or by any means,
electronic or mechanical, including but not limited to photocopying, recording, transmitting via fax
and/or modem devices, scanning, and/or information storage and retrieval systems for any
purpose without the expressed written consent of the company.
WARNING: The MLiS GSM Terminal is a RF product intended for interfacing and operating with
a host device. Local relevant RF regulations such as allowed frequencies and usage in
commercial flights must be observed. Safety instructions must be included in the manuals of the
host device. Schmidt & Co., (HK) Ltd assumes NO liability for customers, who fail to comply with
these precautions.
Service and Support
support.mlis@schmidtelectronics.com
Download Information
http://www.schmidtm2m.com/en/support_download.php
MLB-Z4001 Terminal User Guide 3 Rev 1.0
CONTENTS
1 INTRODUCTION ............................................................................................................................... 5
1.1 Description ................................................................................................................................ 5
1.2 Highlights .................................................................................................................................. 5
1.3 Functional Block diagram .......................................................................................................... 7
1.4 Main Features and Services ...................................................................................................... 8
1.4.1 Operating Modes ................................................................................................................... 8
1.4.2 Terminal Features and Electrical Specifications .................................................................... 9
1.5 Precautions ............................................................................................................................... 9
2 MECHANICAL DESCRIPTION ........................................................................................................ 10
2.1 Overview ................................................................................................................................. 10
2.2 Dimensions ............................................................................................................................. 10
3 ELECTRICAL INTERFACE DESCRIPTIONS .................................................................................. 11
3.1 Overview ................................................................................................................................. 11
3.2 Radio Interface (Type SMA Connector Female) - RF Antenna ................................................ 13
4 OPERATING MODES ..................................................................................................................... 14
4.1 Power on the Modem .............................................................................................................. 14
4.2 Configuration Tool ......................................................................................................................... 14
4.1.1 Data Connection Demo ....................................................................................................... 15
5 SALES CONTACT ........................................................................................................................... 18
6 ORDER INFORMATION .................................................................................................................. 19
MLB-Z4001 Terminal User Guide 4 Rev 1.0
List of Figures
Figure 1: Functional Block Diagram for MLB-Z4001 ............................................................................... 7
Figure 2: Chassis Dimension for MLB-Z4001 ....................................................................................... 10
Figure 3: External Interfaces/Indicators for MLB-Z4001 ....................................................................... 11
Figure 4: Antenna Connector for MLB-Z4001 ...................................................................................... 13
List of Tables
Table 1: Operating Modes ..................................................................................................................... 8
Table 2: Features and Specifications ..................................................................................................... 9
Table 3: Chassis Dimensions and Mechanical Description for MLB-Z4001 .......................................... 10
Table 4: RS232 connector configuration for MLB-Z4001...……………………………………………
……12
Table 5 : Interfaces and Indicators Description of MLB-Z4001 ............................................................. 13
MLB-Z4001 Terminal User Guide 5 Rev 1.0
1 INTRODUCTION
1.1 Description
The MLiS MLB-Z4001 900HMZ ZigBee terminal is a compact terminal that is designed for
wireless M2M communications.
The MLB-Z4001 terminal uses the RJ45 Connector to provide data communication interface and
the DC jack to provide power input. LEDs are used to indicate the status of the terminal.
MLB-Z4001 is taking advantage of the specific Mesh networking protocol, featuring dense
network operation and supporting for sleeping routers, and are also available in a proprietary
point-to-multipoint configuration.
The MLB-Z4001 terminal can be used to provide a wireless communications link for many
applications, including warehouse, building automation, and street light applications.
1.2 Highlights
Interface
DC jack connector for power
RJ45 connector for data communications
SMA female connector (Antenna connector)
General Features
ZigBee 902 to 928 MHZ, software selectable channel mask for interference immunity
Supply voltage range: 5~32VDC
Temperature range
- Operating: -40°C~+75°C
Surge protection: IEC61000-4-5 LV1
Casing Material: Metal
Dimensions (L) x(W) X(H) : 85 x 97 x 24mm (excluding connectors)
Weight: 210g
MLB-Z4001 Terminal User Guide 6 Rev 1.0
Data Transmission
RF Data Rate: 10 Kbps or 200 Kbps
Indoor/Urban Range: up to 2000 foot (610 m)
Outdoor/ Line-Of-Sight Range: Up to 9 miles (14 km) w/ dipole antenna;
Up to 28 miles (45 km) w/ high-gain antenna
Transmit Power: Up to 24 dBm (250 mW) software selectable
Receiver Sensitivity: -101 dBm @ 200 Kbps, -110 dBm @ 10 Kbps
MLB-Z4001 Terminal User Guide 7 Rev 1.0
1.3 Functional Block Diagram
Figure 1: Functional Block Diagram for MLB-Z4001
The MLB-Z4001 consists of a fully certified (CE approved) .
The terminal is supplied with power via the DC jack connector. The RJ45 connector pins are used
for data communications.
The SMA female connector provides the air interface to an external 50 ohm antenna specified for
the correct frequency band.
MLB-Z4001 Terminal User Guide 8 Rev 1.0
1.4 Main Features and Services
The MLB-Z4001 performs a set of ZigBee services according. The services and functions of the
MLB-Z4001 are implemented by issuing customized applications embedded on the device, or
over the RJ45 to Ethernet interface.
1.4.1 Operating Modes
The table below briefly summarizes the various operating modes referred to in the following
chapters.
Table 1: Operating Modes
S/N
Feature
Specifications
1
Frequency Bands
ZigBee-900MHZ
2
RF Output Power
Up to 24dbm (250mw) software selectable
3
Power Supply
5 to 32 VDC
4
Operating
Temperature
Normal operation: -40°C to +85°C
Restricted operation: -40°C to -30°C, +85°C to +90°C
5
Data Transfer
RF Data Rate:10 kbps or 200 kbps
Indoor/Urban Range: up to 2000 ft (610m)
6
AT Commands
Access by AT Commands
7
Ethernet Interface
RJ45 connector
8
Antenna
50 ohms via External SMA Connector
9
HW Reset
Reset Key
10
RoHs
All hardware components are fully compliant with the EU
RoHs directive 2002/95/EC
Exception: MLB55IN
MLB-Z4001 Terminal User Guide 9 Rev 1.0
1.4.2 Terminal Features and Electrical Specifications
MLB-Z4001
General Features
Frequency Band
902 to 928 MHZ ,
software selectable channel mask for interference immunity
Power input
5 to 32 VDC
Operating
Temptation
-40°C~+7C
ESD Protection
IEC61000-4-5 LV1
Dimension
(L)x(W)x(H)
85mm x 97mm x 24mm (excluding connectors)
Weight
210g
Casing Material
Metal
Data Transmission
RF Data Rate
10 Kbps or 200 Kbps
Indoor/Urban Range
up to 2000 ft (610m)
Outdoor/ Line-of-
Sight Range
Up to 9 miles (14 km) w/ dipole antenna;
Up to 28 miles (45 km) w/ high-gain antenna
Transmit Power
Up to 24 dBm (250 mW) software selectable
Receiver Sensitivity
-101 dBm @ 200 Kbps, -110 dBm @ 10 Kbps
Special Features
Networking
Topologies
Mesh, Repeater, Point-to-Point, Point-to-Multipoint, Peer-to-Peer
Spread Spectrum
FHSS (Software Selectable Channels)
Interfaces
RF Antenna Socket
50ohm SMA
Power Connector
DC jack Connector
Ethernet Interface
RJ45 connect for Ethernet (female)
LED
1 x for Power , 1 x for Tx\Rx, 1 x Ethernet Indicator
Reset
HW Reset
Approvals
CE
Yes
Table 2: Features and Specifications
1.5 Precautions
The MLB-Z4001 terminal is designed for indoor use only. For outdoor use it has to be integrated
into a weatherproof enclosure. Do not exceed the environmental and electrical limits as specified
in the user manual.
MLB-Z4001 Terminal User Guide 10 Rev 1.0
2 MECHANICAL DESCRIPTION
2.1 Overview
The pictures below show the mechanical design of the terminal along with the positions of the
different connectors. The terminal case is made of durable PC/ABS plastic.
2.2 Dimensions
Figure 2: Chassis Dimension for MLB-Z4001
S/N
Value
1
24mm
2
85mm
3
97mm
4
210g
5
Metal
6
Suitable for use with DIN
Rail Clips
Table 3: Chassis Dimensions and Mechanical Description for MLB-Z4001
MLB-Z4001 Terminal User Guide 11 Rev 1.0
3 ELECTRICAL INTERFACE DESCRIPTIONS
3.1 Overview
1 2 3
Front/Back View
Figure 3: External Interfaces/Indicators for MLB-Z4001
Table below defines the RJ45 pin configuration on the Terminal:
Pin No.
Signal Name
Function
1
Tx+
2
CT
VDD33A
3
Tx-
4
NC
5
NC
6
Rx+
7
CT
VDD33A
8
Rx-
9
LED1+
Indicator
10
LED1-
11
LED2+
Indicator
12
LED2-
Table 4: RJ45 Connector Configuration for MLB-Z4001
MLB-Z4001 Terminal User Guide 12 Rev 1.0
The interfaces and indicators for MLB-Z4001 are as follows:
Item
Description
Function
1
DC-jack
For Power
2
Reset
HW-Reset-Key
3
RJ45
Signal Transmission Signal Trans
Item
Description
Function
Status
1
LED (Green)
Power -LED
Turn on the power LED is lit
2
LED (Green\Yellow)
TX\RX- LED
Data transfer-Green is lit\receive-Yellow is lit
3
LED(Orange)
Link-LED
Ethernet link-Orange is lit
Table 5: Interfaces and Indicators Description of MLB-Z4001
MLB-Z4001 Terminal User Guide 13 Rev 1.0
3.2 Radio Interface (Type SMA Connector Female) - RF Antenna
Figure 4: Antenna Connector for MLB-Z4001
The connection of the antenna or other equipment must be decoupled from DC voltage.
For optimum RF performance, the MLiS Terminal has to be connected to an external RF antenna
matched to 50ohms including other connecting cables across the operating frequency bands.
Please use a SMA Male connection for the terminal.
Choose suitable types of low attenuation coaxial cables if possible. In general the ohm types
RG174 or RG58 50 can be used. Avoid excessive cable length of > 10 meter
Compatible RF antennas (PCB patched or Monopole type) are available for order, please
refer to accessories document.
MLB-Z4001 Terminal User Guide 14 Rev 1.0
4 OPERATING MODES
4.1 Power on the Modem
The modem is usually fully operational within 4 seconds, after powering it up. Depending on the
signal strength of the network in the area, logging into a network may take longer and is outside
the control of the modem.
4.2 Configuration Tool
The MLB-Z4001 Configuration Tool can be used to set Network ID,
Source Address, Destination Address and send data for test MLB-
Z4001.
MLB-Z4001 Terminal User Guide 15 Rev 1.0
4.1.1 Data Connection Demo
1. Set IP of NIC to 192.168.0.5 for communicating with Z4001.
2. Use the Finder to find the IP of Z4001.
MLB-Z4001 Terminal User Guide 16 Rev 1.0
3. Then use utility connect to the IP with port 5000 (Notice! If connect to unknown IP will
cause error! )
4. After about 5-10 sec will be connected and show => now we can Read the value of
XBee now or disconnect.
MLB-Z4001 Terminal User Guide 17 Rev 1.0
5. After press Read All => it takes a while to read the value of XBee.
6. Now we can modify value then Press Write All, after a while the Value will be set.
MLB-Z4001 Terminal User Manual 18 Rev 1.0
5 SALES CONTACT
Website : www.schmidtm2m.com
Taiwan
Schmidt & Co., (Hong Kong) Limited
5/F, 139 Song Jiang Road, Taipei 104, Taiwan
T (886-2) 2502-5095
F (886-2) 2502-6717
E info@schmidthk.com
Shenzhen,
China
Schmidt & Co., (China) Ltd. Shenzhen Branch
Schmidt (Shenzhen) Co., Ltd
3/F Unit E, International Culture Building,
Fu Tian Road,
Shenzhen 518033
T (86-755) 8376-0232
F (86-755) 8376-0025
E info@schmidthk.com
Singapore
Schmidt Electronics (S.E.A.) Pte Ltd
158 Kallang Way #06-10, Performance Building Singapore 349245
T (65) 6272-7233
F (65) 6273-4750
E info.sg@schmidtelectronics.com
MLB-Z4001 Terminal User Manual 19 Rev 1.0
6 ORDER INFORMATION
MLiS Product
MLB-Z4001: MLiS 900MHZ ZigBee Terminal
Power Adaptor
MLA-PSP-100: Input: AC 100 ~ 240V Output: 9V/1.3A DC jack 5.5/2.1
MLA-PSP-101: US Adapter Plug
MLA-PSP-104: British Adapter Plug
MLA-PSP-103: European Adapter Plug
MLA-PSP-102: Australia Adapter Plug
MLA-CAB-001: DC jack power line 5.5/2.1
Cable
MLA-CAB-101: DB9 connector for RS232 (female)
Antenna
MLA-ANT-004: 900MHZ RPSMA antenna 2.1dBi
MLB-Z4001 Terminal User Manual 20 Rev 1.0
Regional Contact
Taiwan | +886 2-2502-5095
China | +86 (755) 8376-0232
Singapore | +65 6272-7233
Email | sales.m[email protected]
Official Website
MLiS Website | www.schmidtm2m.com
Support | www.schmidtm2m.com/support
Download | www.schmidtm2m.com/download
Facebook | www.facebook.com/MLiSM2M
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

MLis MLB-Z4001 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI