Coolcam NAS-AB02ZE User manual

  • Hello! I've reviewed the Siren user manual and am here to help with your questions about its features, setup, and operation. This manual covers topics like inclusion/exclusion, sound configuration, security and smart start. I'm ready for your questions!
  • How to include the device into Z-Wave network?
    How to reset the device to factory defaults?
    How many association groups does the device support?
    What security level does the device support?
S
i
r
e
n
User
M
an
u
a
l
V
e
r
s
i
on
Written By
D
a
t
e
C
h
a
n
g
e
L
i
s
t
1.0
Y
o
n
g
q
i
20180412
I
n
i
t
i
a
l
1.1
Y
o
n
g
q
i
20180730
Modify
C
o
n
f
i
g
ur
a
t
i
o
n
CC
1.2
Y
o
n
g
q
i
20180806
Modify “Security
K
e
y
s
T
a
b
l
e
This
d
e
v
i
c
e
is
an
a
ud
i
b
l
e
and
visual
a
l
a
r
m
w
i
t
h
10
d
i
ff
e
r
e
n
t
sounds and
i
t
is
based on
Z
-
W
a
v
e
P
l
u
s
t
e
c
hno
l
o
g
y
.
This
product can be
i
n
c
l
ud
e
d
and operated
in
any
Z
-
W
a
v
e
network
w
i
t
h
other
Z
-
W
a
v
e
c
e
r
t
i
f
i
e
d
d
e
v
i
c
e
s from other manufacturers
a
nd
/
or
other
a
pp
li
c
a
t
i
on
s.
All
non-battery operated nodes
w
i
t
h
i
n
the network
will
act as repeaters
r
e
g
a
rd
l
e
ss of vendor to
i
n
c
r
e
a
s
e
reliability
of the
n
e
t
w
or
k
.
Z
-
W
a
v
e
Network
I
n
c
l
u
s
i
on
/
E
xc
l
u
s
i
on
/
R
e
s
e
t
T
h
e
r
e
is
one button
in
the back s
i
d
e
of the sensor,
i
t
can be executed
inclusion, exclusion
and
r
e
s
e
t
from
Z
-
W
a
v
e
n
e
t
w
or
k
.
I
n
c
l
u
s
i
on
¹
1Power up the
d
e
v
i
c
e
.
2
S
e
t
Z
-
W
a
v
e
C
on
t
ro
ll
e
r
i
n
t
o
i
n
c
l
u
s
i
on
m
od
e
3Press the button 3
t
i
m
e
s
w
i
t
h
i
n
1.5s
t
o
enter
inclusion
m
od
e
.
4
T
h
e
d
e
v
i
c
e
will
be
r
e
c
o
g
n
i
z
e
d
a
nd
a
u
t
o
m
a
t
i
c
a
ll
y
i
n
c
l
ud
e
d
i
n
t
o
Z
-
W
a
v
e
Network.
L
e
d
lights will
b
e
b
li
n
k
e
d
w
i
t
h
1s
i
n
t
e
r
v
a
l
un
t
il i
n
c
l
u
s
i
on
s
u
cc
e
ss
f
u
l
.
E
x
c
l
u
s
i
on
1Power up the
d
e
v
i
c
e
.
2
S
e
t
Z
-
W
a
v
e
C
on
t
ro
ll
e
r
i
n
t
o
e
x
c
l
u
s
i
on
m
od
e
3Press the button 3
t
i
m
e
s
w
i
t
h
i
n
1.5s
t
o
enter
exclusion
m
od
e
L
e
d
lights will
b
e
b
li
n
k
e
d
3
t
i
m
e
s
w
i
t
h
0.3s
i
n
t
e
r
v
a
l
.
Factory
R
e
s
e
t
²
1Power up the
d
e
v
i
c
e
.
2Press and
ho
l
d
the button for 10s
un
t
il
l
e
d
lights is
on, then
r
e
l
e
a
s
e
t
h
e
bu
tt
on
.
R
e
s
e
t
successfully,
l
e
d
light will
be
Blinked
5
t
i
m
e
s.
Product
T
e
s
t
M
od
e
1Press and
ho
l
d
the
bu
tt
on
.
2Power on the
d
e
v
i
c
e
,
d
e
v
i
c
e
will
e
n
t
e
r
factory product test m
od
e
L
e
d
will blink
w
i
t
h
100ms
i
n
t
e
r
v
a
l
.
Notice 1: When
d
e
v
i
c
e
enters
i
n
t
o
inclusion
mode, the
d
e
v
i
c
e
all
f
un
c
t
i
on
a
li
t
y will
be
u
s
e
l
e
ss.
T
h
e
inclusion
mode
will
be
t
i
m
e
ou
t
after 30s, user can press the button 3
t
i
m
e
s
w
i
t
h
i
n
1.5s to
t
e
r
m
i
n
a
t
e
inclusion
m
od
e
.
Notice 2:
Factory
R
e
s
e
t
will
c
l
e
a
r
the
d
e
v
i
c
e
all
Z
-
W
a
v
e
Network data
(
i
n
c
l
ud
e
home
id,
node
i
d
,
e
t
c
)
saved
in
memory, and restore
all c
on
f
i
g
ur
a
t
i
on
parameters to factory
d
e
f
a
u
l
t
.
P
l
e
a
s
e
use
t
h
i
s
procedure
only
when the network
pr
i
m
a
r
y
c
on
t
ro
ll
e
r
is missing
or
o
t
h
e
r
w
i
s
e
i
nop
e
r
a
b
l
e
.
A
ss
o
c
i
a
t
i
on
T
h
e
d
e
v
i
c
e
supports 1
a
ss
o
c
i
a
t
i
on
groups, and each group supports max 5
a
ss
o
c
i
a
t
e
d nod
e
s.
Group 1
is lifeline
group;
all
nodes
which
a
ss
o
c
i
a
t
e
d
in
t
h
i
s group
will
r
e
c
e
i
v
e
the messages sent by
d
e
v
i
c
e
through
li
f
e
li
n
e
.
G
roup
C
o
mm
a
nd
C
l
a
ss
1
(
L
i
f
e
li
n
e
)
C
O
MM
A
N
D
_
C
L
ASS
_
N
O
T
I
F
I
C
A
T
I
O
N
C
O
MM
A
N
D
_
C
L
ASS
_
S
W
I
TC
H
_
B
I
N
AR
Y
C
O
MM
A
N
D
_
C
L
ASS
_
BA
TTE
R
Y
C
O
MM
A
N
D
_
C
L
ASS
_
D
EV
I
CE
_
R
E
S
ET
_
L
O
C
A
LL
Y
Z
-
W
a
v
e
Message
R
e
po
r
t
Once the
d
e
v
i
c
e
is
t
r
i
gg
e
r
e
d
by an
a
ss
o
c
i
a
t
e
d d
e
v
i
c
e
or
c
on
t
ro
ll
e
r
,
i
t
will
report two events
t
o
c
on
t
ro
ll
e
r
to
i
nd
i
c
a
t
e
d
e
v
i
c
e
state:
Notification
R
e
por
t
and
Switch Binary
R
e
por
t
.
Notification
R
ep
o
r
t
C
o
mm
a
nd
C
l
a
ss
C
O
MM
A
N
D
_
C
L
ASS
_
N
O
T
I
F
I
C
A
T
I
O
N
C
o
mm
a
nd
NOTIFICATION_REPORT
T
y
p
e
SIREN
(
0
x
0
E
)
E
v
e
n
t
NOTIFICATION_EVENT_SIREN_ACTIVE
(0x01)
NOTIFICATION_EVENT_SIREN_INACTIVE
(0x00)
Switch
Binary
R
ep
o
r
t
C
o
mm
a
nd
C
l
a
ss
C
O
MM
A
N
D
_
C
L
ASS
_
S
W
I
TC
H
_
B
I
N
AR
Y
C
o
mm
a
nd
S
W
I
TC
H
_
B
I
N
AR
Y
_
R
E
PO
R
T
V
a
l
u
e
0
x
00
/
0
x
FF
Z
-
W
a
v
e
C
on
t
r
o
l
C
o
mm
a
nd
Turn
on
S
i
r
en
There are three modes to turn on siren listed as table below:
Siren
S
t
a
t
e
C
o
mm
a
nd
C
l
a
ss
C
o
mm
a
nd
V
a
l
u
e
ON
C
O
MM
A
N
D
_
C
L
ASS
_
S
W
I
TC
H
_
B
I
N
AR
Y
S
W
I
TC
H
_
B
I
N
AR
Y
_
S
ET
0
x
FF
C
O
MM
A
N
D
_
C
L
ASS
_
BAS
I
C
BAS
I
C
_
S
ET
0
x
FF
C
O
MM
A
N
D
_
C
L
ASS
_
I
N
D
I
C
A
T
O
R
I
N
D
I
C
A
T
O
R
_
S
ET
0x01 ~ 0
x
0
A
Turn
off
S
i
r
en
There are three modes to turn off siren listed as table below:
Siren
S
t
a
t
e
C
o
mm
a
nd
C
l
a
ss
C
o
mm
a
nd
V
a
l
u
e
O
FF
C
O
MM
A
N
D
_
C
L
ASS
_
S
W
I
TC
H
_
B
I
N
AR
Y
S
W
I
TC
H
_
B
I
N
AR
Y
_
S
ET
0x00
C
O
MM
A
N
D
_
C
L
ASS
_
BAS
I
C
BAS
I
C
_
S
ET
0x00
C
O
MM
A
N
D
_
C
L
ASS
_
I
N
D
I
C
A
T
O
R
I
N
D
I
C
A
T
O
R
_
S
ET
0x00
Alarm
Sound
S
e
l
e
c
t
T
h
e
r
e
have 10
a
l
a
r
m sounds
building in
t
h
i
s
d
e
v
i
c
e
.
T
h
e
r
e
have 2 methods for user to s
e
l
e
c
t
d
i
ff
e
r
e
n
t
s
ound
:
1 User can s
e
l
e
c
t
a
l
a
r
m sound by
c
on
f
i
g
ur
e
d
the
C
on
f
i
g
ur
a
t
i
on
No. 5 and 6.
2 User can
play
a
l
a
r
m sound by send
INDICATOR_SET
command
w
i
t
h
C
O
MM
A
N
D
_
C
L
ASS
_
I
N
D
I
C
A
T
O
R
:
C
o
mm
a
nd
Sound
I
nd
e
x
Playing
V
o
l
u
m
e
And
T
i
m
e
INDICATOR _SET =
0x01
1
Defined By
Param #3, #4
INDICATOR _SET =
0x02
2
Defined By
Param #3, #4
INDICATOR _SET =
0x03
3
Defined By
Param #3, #4
INDICATOR _SET =
0x04
4
Defined By
Param #3, #4
INDICATOR _SET =
0x05
5
Defined By
Param #3, #4
INDICATOR _SET =
0x06
6
Defined By
Param #3, #4
INDICATOR _SET =
0x07
7
Defined By
Param #3, #4
INDICATOR _SET =
0x08
8
Defined By
Param #3, #4
INDICATOR _SET =
0x09
9
Defined By
Param #3, #4
INDICATOR_SET
= 0
x
0
A
10
Defined By
Param #3, #4
Other
v
a
l
u
e
s
(0x0B
~
0xFF)
are
i
n
v
a
li
d
.
C
o
mm
a
nd
Class
C
on
f
i
g
u
r
a
t
i
on
The device supports the controller to configure parameters of the device through Configuration
Command Class, and the device has 9 parameters available for users to set according to their
different needs:
1)
Alarm
Sound
V
o
l
u
m
e
This
parameter
d
e
f
i
n
e
s the output
v
o
l
u
m
e
when s
i
r
e
n
plays
door
bell
sound. Door
Bell s
ound
v
o
l
u
m
e
is
d
i
v
i
d
e
d
i
n
t
o
3 stages,
L
o
w
(Parameter
is
set to
‘1’),
Middle
(Parameter
is
set to
2
)
,
High
(Parameter
is
set to
‘3’).
D
e
f
a
u
l
t
v
a
l
u
e
is
3
.
Parameter Number
Size (Byte)
Available Settings
Default value
1
1
1~ 3
3
2)
Alarm
Sound Duration
T
i
m
e
This
Parameter
d
e
f
i
n
e
s the
a
l
a
r
m sound
dur
a
t
i
on
t
i
m
e
when s
i
r
e
n r
e
c
e
i
v
e
an
a
l
a
r
m s
e
n
s
or
no
t
i
f
i
c
a
t
i
on
report or an
a
l
a
r
m command from
c
on
t
ro
ll
e
r
.
T
h
e
dur
a
t
i
on
t
i
m
e
is
d
i
v
i
d
e
d
i
n
t
o
5 s
t
a
g
e
s
:
Siren is
not on (Parameter
is
set to
0
)
,
30 second (Parameter
is
set to
1
)
,
1 m
i
nu
t
e
(Parameter
is
set to
2
)
,
5 m
i
nu
t
e
(Parameter
is
set to
3
)
Siren is always
on
un
t
il
battery
is
dead (Parameter
is
set to
0
x
7
F
)
.
D
e
f
a
u
l
t
v
a
l
u
e
is
2
.
T
h
e
v
a
l
u
e
for
t
h
i
s parameter
is
un
s
i
g
n
e
d
v
a
l
u
e
.
Parameter Number
Size (Byte)
Available Settings
Default value
2
1
0 ~ 3, 127
2
3) Door
Bell
Sound Duration
T
i
m
e
This
parameter
d
e
f
i
n
e
s the door
bell
sound
dur
a
t
i
on
t
i
m
e
when s
i
r
e
n r
e
c
e
i
v
e
s a
door
/
w
i
ndo
w
sensor
no
t
i
f
i
c
a
t
i
on
report or an
a
l
a
r
m command
(BASIC_SET
= 0x02) from
c
on
t
ro
ll
e
r
.
T
h
e
door
bell
sound
will
be
p
l
a
y
e
d
always if
t
h
i
s parameter
is
set to
‘0x7F’.
T
h
e
door
bell
sound
will
not
b
e
p
l
a
y
e
d
if
t
h
i
s parameter
is
set to
‘0’.
Other
v
a
l
u
e
s are the door
bell
sound
playing
dur
a
t
i
on
t
i
m
e
.
Unit:
T
i
m
e
.
T
h
e
v
a
l
u
e
for
t
h
i
s parameter
is
un
s
i
g
n
e
d
v
a
l
u
e
.
Parameter Number
Size (Byte)
Available Settings
Default value
3
1
0 ~ 127
1
4) Door
Bell
Sound
V
o
l
u
m
e
This
parameter
d
e
f
i
n
e
s the output
v
o
l
u
m
e
when s
i
r
e
n
plays
a
l
a
r
m sound. Door
Bell s
ound
v
o
l
u
m
e
is
d
i
v
i
d
e
d
i
n
t
o
3 stages:
L
o
w
(Parameter
is
set to
‘1’),
Middle
(Parameter
is
set to
2
)
,
H
i
g
h
(
P
a
r
a
m
e
t
e
r
is
set to
‘3’).
D
e
f
a
u
l
t
v
a
l
u
e
is
1
.
Parameter Number
Size (Byte)
Available Settings
Default value
4
1
1 ~ 3
1
5)
Alarm
Sound
I
nd
e
x
This
parameter
d
e
f
i
n
e
s the
a
l
a
r
m sound
i
nd
e
x
for s
i
r
e
n
play
d
i
ff
e
r
e
n
t
sound when
a
l
a
r
m
o
cc
ur
s.
T
h
e
r
e
are 10
d
i
ff
e
r
e
n
t
sound for user s
e
l
e
c
t
i
on
.
Parameter Number
Size (Byte)
Available Settings
Default value
5
1
1 ~ 10
10
6) Door
Bell
Sound
I
nd
e
x
This
parameter
d
e
f
i
n
e
s the door
bell
sound
i
nd
e
x
for s
i
r
e
n
play
d
i
ff
e
r
e
n
t
sound when
a
l
a
r
m
occurs.
T
h
e
r
e
are 10
d
i
ff
e
r
e
n
t
sound for user s
e
l
e
c
t
i
on
.
Parameter Number
Size (Byte)
Available Settings
Default value
6
1
1~ 10
9
7) Default Siren On
M
od
e
This
parameter
d
e
f
i
n
e
s the
d
e
f
a
u
l
t
sound
i
nd
e
x
,
v
o
l
u
m
e
and the
dur
a
t
i
on
t
i
m
e
for s
i
r
e
n
on.
T
h
i
s
parameter can be s
e
l
e
c
t
e
d
between
A
L
AR
M
SOUND
and
DOOR BELL SOUND.
T
h
e
s
e
tt
i
n
g
s
f
or
A
L
AR
M
SOUND MODE
d
e
f
i
n
e
s by Param #1, #2 and #5.
T
h
e
s
e
tt
i
n
g
s for
DOOR BELL S
O
UN
D
MODE
d
e
f
i
n
e
s by Param #3, #4 and #6.
If
parameter
is
set to
‘1’, s
i
r
e
n
will s
e
l
e
c
t
A
L
AR
M
SOUND MODE
to
play s
ound
;
If
parameter
is
set to
‘2’, s
i
r
e
n
will s
e
l
e
c
t
DOOR BELL
SOUND MODE
to
play s
ound
;
Parameter Number
Size (Byte)
Available Settings
Default value
7
1
1, 2
1
8)
Alarm
L
e
d
E
n
a
b
l
e
This
parameter
d
e
f
i
n
e
s the
d
e
f
a
u
l
t
l
e
d
e
n
a
b
l
e
status when s
i
r
e
n
is
on for
A
L
AR
M
SOUND
M
O
D
E
.
If
parameter
is
set to
‘0’,
l
e
d
will
be
d
i
s
a
b
l
e
.
If
parameter
is
set t0
‘1’,
l
e
d
will
be
e
n
a
b
l
e
. When s
i
r
e
n
is
on, the
l
e
d
will
b
li
n
k
.
Parameter Number
Size (Byte)
Available Settings
Default value
8
1
0, 1
1
9) Door
Bell
L
e
d
E
n
a
b
l
e
This
parameter
d
e
f
i
n
e
s the
d
e
f
a
u
l
t
l
e
d
e
n
a
b
l
e
status when s
i
r
e
n
is
on for
DOOR BELL S
O
UN
D
M
O
D
E
.
If
parameter
is
set to
‘0’,
l
e
d
will
be
d
i
s
a
b
l
e
.
If
parameter
is
set t0
‘1’,
l
e
d
will
be
e
n
a
b
l
e
. When s
i
r
e
n
is
on, the
l
e
d
will
b
li
n
k
.
Parameter Number
Size (Byte)
Available Settings
Default value
9
1
0, 1
0
B
a
tt
e
r
y
C
o
mm
a
nd
C
l
a
ss
T
h
e
users can
a
l
s
o
e
nqu
i
r
e
the battery status of the
d
e
v
i
c
e
by s
e
nd
i
n
g
BATTERY_GET
c
o
mm
a
nd
.
Once the
d
e
v
i
c
e
r
e
c
e
i
v
e
r
s the command,
i
t
will
return
BA
TTE
R
Y
_
R
E
PO
R
T
c
o
mm
a
nd
.
T
h
e
d
e
v
i
c
e
will
send
BA
TTE
R
Y
_
L
EVE
L
=
0xFF
command to the
Z
-
W
a
v
e
C
on
t
ro
ll
e
r
to
i
n
f
or
m that
t
h
e
d
e
v
i
c
e
is in
dead battery status,
o
t
h
e
r
w
i
s
e
BA
TTE
R
Y
_
L
EVE
L
v
a
l
u
e
range
is 0%
to 100%.
Smart Start
This
d
e
v
i
c
e
supports
S
m
a
r
t
S
t
a
r
t
f
un
c
t
i
on
.
QR
code
pr
i
n
t
e
d
by
l
a
s
e
r
can be found on surface of
product and the
ou
t
s
i
d
e
of
packing
box.
And
the
full DSK
code
is
pr
i
n
t
e
d
can be found on
t
h
e
packing
box.
T
h
e
d
e
v
i
c
e
will
enter
S
m
a
r
t
S
t
a
r
t
if
the
d
e
v
i
c
e
is
not
i
n
c
l
ud
e
d
in
network after power up.
And
i
f
d
e
v
i
c
e
is
not
i
n
c
l
ud
e
d
successfully
dur
i
n
g
10 second,
i
t
will
enter s
l
ee
p
mode.
And
then
2nd
S
m
a
r
t
S
t
a
r
t t
i
m
e
d
e
l
a
y
a
ppro
x
i
m
a
t
e
l
y
16s
3rd
S
m
a
r
t
S
t
a
r
t t
i
m
e
d
e
l
a
y
a
ppro
x
i
m
a
t
e
l
y
32s
4th
S
m
a
r
t
S
t
a
r
t t
i
m
e
d
e
l
a
y
a
ppro
x
i
m
a
t
e
l
y
64s
5th
S
m
a
r
t
S
t
a
r
t t
i
m
e
d
e
l
a
y
a
ppro
x
i
m
a
t
e
l
y
128s
6th
S
m
a
r
t
S
t
a
r
t t
i
m
e
d
e
l
a
y
a
ppro
x
i
m
a
t
e
l
y
256s
7th
S
m
a
r
t
S
t
a
r
t t
i
m
e
d
e
l
a
y
a
ppro
x
i
m
a
t
e
l
y
512s
A
f
t
e
r
w
a
rd
s
,
the
S
m
a
r
t
s
t
a
r
t
mode
will
be auto
runn
i
n
g
w
i
t
h
512 second
i
n
t
e
r
v
a
l
un
t
il
d
e
v
i
c
e
i
s
i
n
c
l
ud
e
d
successfully
or battery run
do
w
n
.
L
e
d
A
c
t
i
on
I
nd
i
c
a
t
o
r
LED
C
o
l
or
L
e
d
Display
S
t
a
t
u
s
D
e
s
c
r
i
p
t
i
on
R
e
d
Blink
5
T
i
m
e
s
(
1s
I
n
t
e
r
v
a
l
)
Power on and Not
Add in
Z
-
W
a
v
e
Network
Blink
5
T
i
m
e
s
(
300ms
I
n
t
e
r
v
a
l
)
Power on and
Already Add in
a
Z
-
W
a
v
e
Network
Blink
3
T
i
m
e
s
(
500ms
I
n
t
e
r
v
a
l
)
1, Press button
t
r
i
p
l
e
d
,
d
e
v
i
c
e
sends
N
od
e
I
n
f
o
.
2, Press button
t
r
i
p
l
e
d
,
d
e
v
i
c
e
enters
i
n
t
o
exclusion
m
od
e
.
1,
Blink
w
i
t
h
1s
i
n
t
e
r
v
a
l
and
t
h
e
n
2,
Blink
15
t
i
m
e
s
w
i
t
h
2s
i
n
t
e
r
v
a
l
Press button
t
r
i
p
l
e
d
,
d
e
v
i
c
e
enters
i
n
t
o
inclusion
m
od
e
.
Device
a
ss
i
g
n
e
d
a node
id
and
w
a
i
t
f
or
c
on
f
i
g
ur
a
t
i
on
c
o
m
p
l
e
t
e
d
.
L
i
g
h
t
On 500ms
Hold
pressed the button and factory
r
e
s
e
t
.
Security
N
e
t
w
o
r
k
T
h
e
d
e
v
i
c
e
supports the s
e
c
ur
i
t
y
f
un
c
t
i
on
w
i
t
h
S2
encrypted
c
o
mm
un
i
c
a
t
i
on
.
T
h
e
d
e
v
i
c
e
will
a
u
t
o
s
w
i
t
c
h
to the s
e
c
ur
i
t
y
mode when the
d
e
v
i
c
e
i
n
c
l
ud
e
d
w
i
t
h
a s
e
c
ur
i
t
y
c
on
t
ro
ll
e
r
.
I
n
the s
e
c
ur
i
t
y
mode, the
follow
commands must use s
e
c
ur
i
t
y
and s
e
c
ur
i
t
y
_
2 command
class
wrapped
t
o
c
o
mm
un
i
c
a
t
e
,
o
t
h
e
r
w
i
s
e
the
d
e
v
i
c
e
will
not response any
c
o
mm
a
nd
s.
S
e
c
u
r
i
t
y
K
e
y
s
This
d
e
v
i
c
e
supports s
e
c
ur
i
t
y
levels
are
li
s
t
e
d
in
b
e
l
o
w
t
a
b
l
e
:
Security
L
e
v
e
l
s
Support
(
Y
e
s
/
N
o
)
S
EC
U
R
I
T
Y
_
K
E
Y
_
S
0
No
S
EC
U
R
I
T
Y
_
K
E
Y
_
S
2
_
UN
A
U
T
H
E
N
T
I
C
A
TE
D
Y
e
s
S
EC
U
R
I
T
Y
_
K
E
Y
_
S
2
_
A
U
T
H
E
N
T
I
C
A
TE
D
No
S
EC
U
R
I
T
Y
_
K
E
Y
_
S
2
_
A
CCE
SS
No
All
S
upp
o
r
t
s
C
o
mm
and
C
l
a
ss
This
d
e
v
i
c
e
supports
All
Z
-
W
a
v
e
C
o
mm
a
nd
C
l
a
ss
e
s
in NIF
L
i
s
t
as
f
o
ll
o
w
s
:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_SECURITY_2 (V1)
* COMMAND_CLASS_TRANSPORT_SERVICE (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (V3)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_NOTIFICATION (V8)
* COMMAND_CLASS_SWITCH_BINARY (V1)
* COMMAND_CLASS_INDICATOR (V1)
* COMMAND_CLASS_CONFIGURATION (V1)
* COMMAND_CLASS_SUPERVISION (V1)
All
S
e
c
u
r
i
t
y
C
o
mm
and
Class in
S
e
c
u
r
i
t
y
N
e
t
w
o
r
k
T
h
e
Z
-
W
a
v
e
C
o
mm
a
nd
C
l
a
ss
e
s are secured
in s
e
c
ur
i
t
y
network as
f
o
ll
o
w
s
:
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (V3)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_NOTIFICATION (V8)
* COMMAND_CLASS_SWITCH_BINARY (V1)
* COMMAND_CLASS_INDICATOR (V1)
* COMMAND_CLASS_CONFIGURATION (V1)
N
o
n
-
S
e
c
u
r
e
C
o
mm
and
Class in
S
e
c
u
r
e
N
e
t
w
o
r
k
Unsecure
C
o
mm
a
nd
Class which
i
n
c
l
ud
e
d
in
a secure
Z
-
W
a
v
e
Network
is
li
s
t
e
d
in
unsecure
nod
e
i
n
f
or
m
a
t
i
on
.
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_SECURITY_2 (V1)
* COMMAND_CLASS_TRANSPORT_SERVICE (V2)
* COMMAND_CLASS_SUPERVISION (V1)
S
p
e
c
i
f
i
c
a
t
i
on
s
Power
S
upp
l
y
CR123A ×2
S
t
a
ndb
y
C
urr
e
n
t
55
u
A
Work
C
urr
e
n
t
(
RF
T
x
)
36mA
(
I
n
Radio
T
r
a
n
s
m
i
tt
e
r
M
o
d
e
)
500mA
(
I
n
Siren
On and Max
V
o
l
um
e
M
o
d
e
)
O
p
e
r
a
t
i
on
a
l
T
e
m
p
e
r
a
t
ur
e
0 - 70
C
o
mm
un
i
c
a
t
i
on
f
r
e
qu
e
n
c
y
868.40MHz, 869.85MHz
(
E
U)
908.40MHz,
916.00
M
H
z(U
S
)
R
a
n
g
e
Up to 45m
i
ndoor
s
(
d
e
p
e
nd
i
n
g
on the
building
structure), and 80m
for outdoor open
f
i
e
l
d
s.
Up to 60m
ou
t
door
s.
/