5. Reinstall the Pole (continued)
• Slide the pole into
the tensioner and
turn tensioner
coupling, locking it
into the tensioner
• Position and lock
retaining screws on
both pole retaining
collars
6. Install the Flexco Blade
• Install Flexco blade on to the formed rib
• Center blade and slide both Flexco pole clamp kit into
blade notches
2525 Wisconsin Avenue • Downers Grove, IL 60515-4200 • USA
Tel: (630) 971-0150 • Fax: (630) 971-1180 • E-mail: info@flexco.com
Visit www.flexco.com for other Flexco locations and products.
©2017 Flexible Steel Lacing Company. 09/27/17. For reorder: X4786
• Tighten both Flexco
pole clamp kit lock
screws on both blade
retaining brackets
7. Re-tension Flexco Blade
• With blade held to the belt, rotate the tensioner
coupling in tension direction and tighten the three
locking screws
• With ratchet knob
turned back 180º,
rotate tensioner
number of clicks
listed on the
tensioner decal for
blade width or in
the tension table
below:
• Conrm correct blade
heel gap per Flexco
guidelines
Belt Width Number
of Clicks
18 2
24 3
39 3
36 4
42 5
48 6
54 3*
60 4*
72 5*
*Per tensioner, dual tensioners standard