  • Hello! I am an AI chatbot trained to assist you with the SICK Differtential pressure monitor Product information. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DATA SHEET
Differential Pressure Monitor
Monitoring of the Purge Air Supply with
In-situ Measuring Systems
Application
The differential pressure monitor is
used for monitoring the purge-air sup-
ply with SICK in-situ measuring sy-
stems. A purge-air blower supplies the
purging-air attachments of the measu-
ring system. The air ow protects the
optical surfaces from, e.g. contamina-
tion or aggressive gases of the waste
gas channel. If the purge-air supply is
not sufcient the differential pressu-
re monitor issues a warning signal via
potentially free contacts.
To ensure safe monitoring of the pur-
ge-air supply the differential pressure
monitor should be installed to the in-
lets of the purge-air attachments.
The differential pressure monitor used in a SICK measuring system e.g. DUSTHUNTER
Flange connection
Purge-air attachment
of the measuring system
Purge-air inlet
Differential
pressure monitor
Purge-air hose
Measuring nozzle
Pressure connection:
higher pressure at P1 (+)
lower pressure at P2 (–)
COM 3
2 NO
P
P
3
2
1
1 NC
60
50
40
30
20
10
0
20
30 40 50 60 70 80 90
P = f (V)
Dimensional drawing
Installation
Attach the hose end of the pressure
monitor with help of the hose band
clip. Attach the purge-air hose with
help of the hose band clip to the inlet
of the pressure monitor.
Setting range
The switching threshold of the
pressure monitor can be set at 5 to
20 hPa for min. purge-air supply (cor-
responding to appr. 20 to 60 m
3
/h;
5.3 to 15.9 gal/h).
Function, settings
During standard operation of the mea-
suring system the purge-air supply is
continuous active. The switching
threshold for minimum purge-air
quantity on the differential pressure
monitor is congurable. If the purge-
air quantity decreases the value
of this switching threshold, the diffe-
rential pressure monitor switches the
potentially free contact in order to si-
gnal missing purge-air.
Electrical connection
Diagram
Volume ow V [m
3
/h]
Diff. pressure ΔP [hPa]
Ø 50
Ø 46
Ø 40
Ø 40
P1 (+)
P2 (-)
103
(128)
180
Dimensions in mm
Technical Data
Pressure connection P1 screw neck M10 x 1
P2 connection adapter ø 6.5 mm (0.3 in)
Mounting position Any, but as near as possible to the purge-air inlet of the
measuring system
Pressure setting range 5 ... 25 hPa (0.07 ... 0.3 psi); tolerance ±15 %
Switching difference 1 hPa (0.02 psi)
Max. operating pressure 100 hPa (1.5 psi)
Temperature range –20 ... +85 °C (–4 ... 185 °F)
Electrical contact rating 250 V AC; 6 A
Electrical connection AMP flat plug 6.3 x 0.8 mm
2
(DIN 46244)
Hose connection ø 40 mm (1.6 in)
Protection class IP 54
Connection Wiring
Throw over switch
Increasing pressure NC opens, NO closes
Decreasing pressure NO opens, NC closes
8007948/2009-03 ∙ 3M ∙ Subject to change without notice
SICK AG | Waldkirch | Germany | www.sick.com
/