Tannoy CVS 6 (EN 54) User manual

Type
User manual
Operation Manual
Mode d’emploi
Betriebsanleitung
Manual de instrucciones
CVS 4 (EN54)
CVS 6 (EN54)
CVS (EN54)
Compact and Medium Format Ceiling Loudspeakers
2
CVS (EN54) Operation Manual rev 1.1.1
Contents
3 English - Operation Manual
17 Français-Moded’emploi
31 Deutsch-Betriebsanleitung
45 Español-Manualdeinstrucciones
CVS (EN54) Operation Manual rev 1.1.1
3
Table of Contents
Table of Contents
1. Introduction 4
2. Unpacking 4
3. Safety Notices 4
4. Product Feature Identication 5
5. Accessories 6
6.1. Installation Guide for Suspended Ceilings 7
6.2. Installation Guide for Sheetrock Ceilings 8
6.3. Installation Guide for Optional Plaster Ring 9
7. Wiring and Setting Up 10
8. CVS (EN54) Dimensions 11
9.1. CVS 4 (EN54) Technical Specications 12
9.2. CVS 6 (EN54) Technical Specications 13
10. Painting 14
11. Warranty 15
1. Introduction
4
CVS (EN54) Operation Manual rev 1.1.1
1. Introduction
ThankyouforpurchasingthisTannoyCeilingloudspeaker.Thisproductrangeissuitedforhigh-levelmusicand
speechreinforcementapplicationsrequiringexceptionalsonicqualitywithuncompromisedreliability.
2. Unpacking
EveryTannoyproductandaccessoryiscarefullyinspectedbeforepacking.Afterunpacking,pleaseinspectyour
producttomakesurenodamagehasoccurredintransit.Intheunlikelyeventofanydamage,wouldyouplease
notifyyourdealerimmediatelyandretainyourshippingcarton,asyourdealermayaskyoutoreturnthefaulty
unittothemforinspection.
EachCVS(EN54)loudspeakerispackedinpairsandprovidedwiththefollowingaccessoriesasstandard;
C-Ring,tile-bridgekit,cut-outtemplate,andpaintmask.Aplaster(mud)ringisalsoavailableasanoptionalextra.
3. Safety Notices
Someregionalconstructioncodesrequiretheuseofasecondarymethodofsecuringloudspeakersinceiling
toprovidesecurityofabackupsupport.Asecondarysupportlineshouldbeattachedfromthesafetyloopon
therearoftheproducttoasourcepointontheceiling.Pleaseconsulttherelevantconstructioncodesinyour
region.
Whenusingapowerdrivertoinstalltheproductitisessentialtousethecorrecttorquelevelsettingstoavoid
overtighteninganddamagetotheceilingmaterialorclamps.
Recommendedtorquesetting:1.5Nm
Tannoywillnotbeheldresponsibleforanydamagescausedbytheimproperinstallationoftheseloudspeakers.
SAFETY NOTE:
In order to comply with the relevant re safety regulations (ie. BS 5839:1998), it is required that in the event of
re, that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the
building is complete. Suitable measures include: -
a) use of terminal blocks (for connection to primary) with a melting point of not less than 650°C, for example
constructed from ceramic materials;
b) use of terminal blocks of a lower melting point but protected with thermal insulation;
c) use of terminal blocks such that, on melting, an open-circuit or a short-circuit does not occur.
4. Product Feature Identification
CVS (EN54) Operation Manual rev 1.1.1
5
4. Product Feature Identification
CVS 4 (EN54)
CVS 6 (EN54)
SafetyTab
SafetyTab
CableClamp
CableClamp
MountingWings ScrewsforMountingWings
MountingWings
RotarySwitch
TuningPorts
ScrewsforMountingWings
RotarySwitch
TuningPorts
5. Accessories
6
CVS (EN54) Operation Manual rev 1.1.1
5. Accessories
Standard Accessories


Optional Accessories
C-Ring Tile-bridgekit
Note:Atile-bridgekit
mustalwaysbeused
wheninstallinginto
suspendedceilingtiles
Paintmask
Plaster(mud)
ring
Cut-outtemplate
6.1. Installation Guide for Suspended Ceilings
CVS (EN54) Operation Manual rev 1.1.1
7
6.1. Installation Guide for Suspended Ceilings
1. Removetheceilingtilefromitsframeandplaceitonaat
surface.Markthecut-outareaontheceilingtilebytracing
aroundthetemplateprovided.(Fig.1)
2.Cutouttheholeintheceilingtileusingapadsaw.(Fig.2)
3.PlacetheC-Ringandtile-bridgeontopoftheceilingpanel,
aligningtheC-Ringoverthehole,andscrewtheC-Ringtothe
tilebridgeusingthexingsprovided.(Fig.3)
4.Slidethespeakerassemblythroughtheholeandturnthe
screwsonthefrontofthespeakertoextendthemountingwings.
Tightenthescrewsuntilarmgripisachieved.Ifusingapower
driver,Tannoyrecommendsatorquesettingof1.5Nm.(Fig.4)
DO NOT OVERTIGHTEN!
5.Slidethetilepanelbackintothesuspendedceiling.Thetile
bridgeendswillcatchovertherailings,supportingtheweightof
thespeaker.(Fig.5)
6.Connectasecondarysupportlinetosafetytab.Some
constructioncodesrequireuseofthissecondarysupportpoint,
whichshouldconnecttoaseparatesecuresupportpointusinga
suitablesupportline.Consultconstructioncodesinyourregion.
Gotosection7forinstructionsonwiringandset-upinstructions.
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
6.2. Installation Guide for Sheetrock Ceilings
8
CVS (EN54) Operation Manual rev 1.1.1
6.2. Installation Guide for Sheetrock Ceilings
1. Markthecut-outareaontheceilingbytracingaroundthe
templateprovided.(Fig.1)
2.Cutouttheholeintheceilingusingapadsaw,thenslidethe
C-Ringintotheceiling,aligningitoverthecut-outhole.(Fig.2)
3.Gotosection7forwiringandset-upinstructionsthenreturn
topoint4below.
4.Slidethespeakerassemblythroughtheholeandturnthe
screwstoextendthemountingwings.Tightenthescrewsuntila
rmgripisachieved.Ifusingapowerdriver,Tannoyrecommends
atorquesettingof1.5Nm.(Fig.3)
DO NOT OVERTIGHTEN!
5.Connectasecondarysupportlinetosafetytab.Some
constructioncodesrequireuseofthissecondarysupportpoint,
whichshouldconnecttoaseparatesecuresupportpointusinga
suitablesupportline.Consultconstructioncodesinyourregion.
6.Insertgrillebypushingitontothespeaker.(Fig.4)
Fig.1
Fig.2
Fig.3
Fig.4
6.3. Installation Guide for Optional Plaster Ring
CVS (EN54) Operation Manual rev 1.1.1
9
6.3. Installation Guide for Optional Plaster Ring
1. Nailorscrewtheplasterringtothejoists.(Fig.1)
2.Laythespeakerwiringtowherethespeakerwillbettedand
completetheplasteringworkontheceiling.
3.Cutouttheholeintheceilingusingapadsaw.(Fig.2)
4.Gotosection7forinstructionsonwiringthenreturntopoint5
below.
5.Slidethespeakerassemblythroughtheholeandturnthe
screwstoextendthemountingwings.Tightenthescrewsuntila
rmgripisachieved.Ifusingapowerdriver,Tannoyrecommends
atorquesettingof1.5Nm.(Fig.3)
DO NOT OVERTIGHTEN!
6.Connectasecondarysupportlinetosafetytab.Some
constructioncodesrequireuseofthissecondarysupportpoint,
whichshouldconnecttoaseparatesecuresupportpointusinga
suitablesupportline.Consultconstructioncodesinyourregion.
7.Insertgrillebypushingitontothespeaker.(Fig.4)
Fig.1
Fig.2
Fig.3
Fig.4
Anoptionalplaster(mud)ringbracketisavailablefromTannoy.Thisbracketisdesignedtobepre-installed
intonewlyconstructed,non-suspendedceilings.
7. Wiring and Setting Up
10
CVS (EN54) Operation Manual rev 1.1.1
7. Wiring and Setting Up
1. Removethewiringcoveratthebackofthespeakercantoaccess
theEuro-typeconnectorplugandsocket.Feedthecablethroughthe
glandandattachtheEuro-typeconnector.(Fig.1)
2.Forconnectiontoanamplier,usePins1and2(Fig.2):
•Pin1ispositive
•Pin2isnegative
Forconnectiontoadditionalspeakersinadistributedline,
Pins3and4areinparallelwhere:
•Pin3isnegative
•Pin4ispositive
3.TightenthecableglandandplugintheEuro-typeconnector.
Replacethecoverandxusingthesuppliedscrews.
THESPEAKERISSUPPLIEDINLOWIMPEDANCEMODE.NEVER
CONNECTTHESPEAKERTOA70/100VOLTAMPLIFIERWHILEIT
ISSETFORLOWIMPEDANCE.
4.TheCVS4(EN54)isttedwitha30Wtransformer.Whenused
indistributed-linesystems,thetransformercanbetappedat30W,
15Wand7.5W,withanadditional3.75Wtappingfor70.7Vline
systems.(Fig.3)
5.TheCVS6(EN54)isttedwitha60Wtransformer.Whenused
indistributed-linesystems,thetransformercanbetappedat60W,
30W,and15W,withanadditional7.5Wtappingfor70.7Vline
systems.
Fig.1
Fig.2
Fig.3
8. CVS (EN54) Dimensions
CVS (EN54) Operation Manual rev 1.1.1
11
8. CVS (EN54) Dimensions
CVS 4 (EN54) Template Cut-out Size: 180 mm
CVS 6 (EN54) Template Cut-out Size: 250 mm
Ø174.8
[6.88"]
Ø213.0
[8.39"]
14.7
[0.58"]
197.9
[7.79"]
224.9
[8.85"]
15.9
[0.63"]
Ø279.6
[11.01"]
Ø244.6
[9.63"]
263.0
[10.35"]
236.0
[9.29"]
9.1. CVS 4 (EN54) Technical Specifications
12
CVS (EN54) Operation Manual rev 1.1.1
9.1. CVS 4 (EN54) Technical Specifications
CVS 4 (EN54)
Technical Data Sheet
tannoy.com/pro
V 1.00 - 18/09/13
Specifi cations
Performance
System
CVS 4 (EN54)
Frequency response (-3 dB)
(1)
85 Hz - 19 kHz
Frequency range (-10 dB)
(1)
77 Hz - 22 kHz
Rated sensitivity (1 W, Lo Z)
(2)
87 dB
Sensitivity as per EN54
(4 m, through transformer)
(2)
73.2 dB
Directivity factor (Q)
5.6 averaged 1 kHz to 6 kHz
Directivity Index (DI)
7.1 averaged 1 kHz to 6 kHz
Power Handling
(3)
Average 40 W
Programme 80 W
Peak 160 W
Recommended Amplifi er Power
80 W @ 6 ohms
Nominal Impedance (Lo, Z)
6 ohms
Maximum SPL as per EN54
(4 m, through transformer)
(2)
87 dB
Rated maximum SPL (1 m, Lo Z)
(2)
Average 103 dB
Peak 109 dB
Transformer Taps (via front rotary switch)
70 V
30 W (165 Ω) / 15 W (330 Ω) / 7.5 W (660 Ω) / 3.75 W (1320 Ω) /
OFF & low impedance operation
100 V
30 W (330 Ω) / 15 W (660 Ω) / 7.5 W (1320 Ω) /
OFF & low impedance operation
Crossover Point
2.7 kHz
Coverage angles
(4)
Horizontal plane Vertical plane
500 Hz
177° 177°
1 kHz
166° 168°
2 kHz
157° 150°
4 kHz
85° 83°
Distortion
10% full power Harmonics
2nd 3rd
250 Hz
0.231% 0.112%
1 kHz
0.229% 0.253%
10 kHz
0.163% 0.025%
1% full power
250 Hz
0.99% 0.169%
1 kHz
0.816% 0.027%
10 kHz
0.444% 0.07%
Transducers
Low Frequency
100 mm (4.00”) mineral loaded cone material
High Frequency
19 mm (0.75”) coaxially mounted
Physical
Enclosure
Blind Mount (BM)
Back can Painted steel
Baffl e Refl ex loaded UL 94V-0 rated ABS
Grille Steel, with weather resistant coating
Safety Features
Safety ring located at rear of enclosure for load bearing safety bond
Clamping Design
Security toggle clamp
Connectors
Euroblock-type connector with screw terminals
(with input cover and cable gland supplied)
Dimensions
Bezel diameter
213.0 mm (8.39”)
Front of ceiling to rear of back can
202.5 mm (7.97”)
Front of ceiling to top of safety loop
214.9 mm (8.46”)
Hole cutout diameter
180 mm (7.09”)
Net Weight (ea)
2.6 kg (5.72 lbs)
Included Accessories
C-Ring, tile-bridge kit, paint mask, cut-out template
Optional Accessories
Plaster (mud) ring
Packed Quantity
2
Ordering Information
Part Number Colour
8001 7620 White /
Paintable
8001 4180
Plaster (Mud) Ring Zinc Plated
(CVS 4) Steel
Notes:
1. Average over stated bandwidth. Measured in
an IEC baffl e in an Anechoic Chamber
2. Unweighted pink noise input, measured at
1 metre on axis
3. Long term power handling capacity as defi ned
in EIA - 426B test
4. The reference point for the reference axis
(on-axis) is the centre of the baf e. The
horizontal and vertical planes are defi ned with
the speaker mounted with the transformer
tapping selector at the bottom
A full range of measurements, performance data,
CLF and Ease™ Data for CVS 4 can be downloaded
from www.tannoy.com. They also apply to the
CVS 4 (EN54).
Tannoy operates a policy of continuous research
and development. The introduction of new materials
or manufacturing methods will always equal or
exceed the publishing specifi cations, which Tannoy
reserves the right to alter without prior notice. Please
verify the latest speci cations when dealing with
critical applications.
Copyright (c) 2013 Tannoy Limited. All rights reserved.
EN54
certified
9.2. CVS 6 (EN54) Technical Specifications
CVS (EN54) Operation Manual rev 1.1.1
13
9.2. CVS 6 (EN54) Technical Specifications
CVS 6 (EN54)
Technical Data Sheet
tannoy.com/pro
V 1.00 - 18/09/13
Specifi cations
Performance
System
CVS 6 (EN54)
Frequency response (-3 dB)
(1)
79 Hz - 21 kHz
Frequency range (-10 dB)
(1)
60 Hz - 24 kHz
Rated sensitivity (1 W, Lo Z)
(2)
91 dB
Sensitivity as per EN54
(4 m, through transformer)
(2)
77.1 dB
Directivity factor (Q)
7.7 averaged 1 kHz to 6 kHz
Directivity Index (DI)
8.0 averaged 1 kHz to 6 kHz
Power Handling
(3)
Average 60 W
Programme 120 W
Peak 240 W
Recommended Amplifi er Power
120 W @ 6 ohms
Nominal Impedance (Lo, Z)
6 ohms
Maximum SPL as per EN54
(4 m, through transformer)
(2)
94.9 dB
Rated maximum SPL (1 m, Lo Z)
(2)
Average 109 dB
Peak 115 dB
Transformer Taps (via front rotary switch)
70 V
60 W (83 Ω) / 30 W (165 Ω) / 15 W (330 Ω) / 7.5 W (660 Ω) /
OFF & low impedance operation
100 V
60 W (165 Ω) / 30 W (330 Ω) / 15 W (660 Ω) /
OFF & low impedance operation
Crossover Point
2.5 kHz
Coverage angles
(4)
Horizontal plane Vertical plane
500 Hz
175° 174°
1 kHz
159° 165°
2 kHz
140° 125°
4 kHz
66° 66°
Distortion
10% full power Harmonics
2nd 3rd
250 Hz
0.439% 0.140%
1 kHz
0.396% 0.458%
10 kHz
0.235% 0.023%
1% full power
250 Hz
1.16% 0.214%
1 kHz
1.014% 0.685%
10 kHz
0.944% 0.047%
Transducers
Low Frequency
150 mm (6.00”) mineral loaded cone material
High Frequency
19 mm (0.75”) coaxially mounted
Physical
Enclosure
Blind Mount (BM)
Back can Painted steel
Baffl e Refl ex loaded UL 94V-0 rated ABS
Grille Steel, with weather resistant coating
Safety Features
Safety ring located at rear of enclosure for load bearing safety bond
Clamping Design
Security toggle clamp
Connectors
Euroblock-type connector with screw terminals
(with input cover and cable gland supplied)
Dimensions
Bezel diameter
297.5 mm (11.01”)
Front of ceiling to rear of back can
246.5 mm (9.70”)
Front of ceiling to top of safety loop
258.5 mm (10.18”)
Hole cutout diameter
250 mm (9.84”)
Net Weight (ea)
4.75 kg (10.45 lbs)
Included Accessories
C-Ring, tile-bridge kit, paint mask, cut-out template
Optional Accessories
Plaster (mud) ring
Packed Quantity
2
Ordering Information
Part Number Colour
8001 7630 White /
Paintable
8001 4181
Plaster (Mud) Ring Zinc Plated
(CVS 6) Steel
Notes:
1. Average over stated bandwidth. Measured in
an IEC baffl e in an Anechoic Chamber
2. Unweighted pink noise input, measured at
1 metre on axis
3. Long term power handling capacity as defi ned
in EIA - 426B test
4. The reference point for the reference axis
(on-axis) is the centre of the baf e. The
horizontal and vertical planes are defi ned with
the speaker mounted with the transformer
tapping selector at the bottom
A full range of measurements, performance data,
CLF and Ease™ Data for CVS 6 can be downloaded
from www.tannoy.com. They also apply to the
CVS 6 (EN54).
Tannoy operates a policy of continuous research
and development. The introduction of new materials
or manufacturing methods will always equal or
exceed the publishing specifi cations, which Tannoy
reserves the right to alter without prior notice. Please
verify the latest speci cations when dealing with
critical applications.
Copyright (c) 2013 Tannoy Limited. All rights reserved.
EN54
certified
10. Painting
14
CVS (EN54) Operation Manual rev 1.1.1
10. Painting
Ifdesired,thegrilleandbafepanelmaybepaintedtomatchthesurroundingdécor.
Paintingthebafe:
• Carefullymaskoffthedriverassemblyusingthepaintmaskprovidedtoensurethatthepaintdoesnotcome
intocontactwiththeconeandrollsurround.
• Applyseveralthincoatsofpaint–thiswillprovideabetternishthanoneoverlythickcoat.
Paintingthegrille:
• Carefullyremovetheacousticallytransparentfoamfromthereversesideofthegrille.
• Paintthegrilleandthenreplacethefoam-severalthincoatsofpaintwillprovideabetternishthanoneoverly
thickcoat.
• Re-bondthefoamtothegrilleovertheentireareausingalightspray-adhesivetoavoidaudibleresonances.
11. Warranty
CVS (EN54) Operation Manual rev 1.1.1
15
11. Warranty
No maintenance of the CVS (EN54) loudspeaker is necessary.
All Tannoy professional loudspeaker products are covered by a 5 year warranty from the date of manufacture
subject to the absence of misuse, overload or accidental damage. Claims will not be considered if the serial
number has been altered or removed. Work under warranty should only be carried out by a Tannoy Professional
dealer or service agent. This warranty in no way affects your statutory rights. For further information please
contact your dealer or distributor in your country. If you cannot locate your distributor please contact Customer
Services, Tannoy Ltd. at the address given below.
CustomerServices
TannoyLtd.
RosehallIndustrialEstate
Coatbridge
Strathclyde
ML54TF
Scotland
Tel: 01236420199(National)
+441236420199(International)
Fax: 01236428230(National)
+441236428230(International)
Support: http://support.tannoy.com
ServiceInfo,TCGroupAmericas
Tel: (800)565-2523(tollfree)
(519)745-1158
Fax: (519)745-2364
Support: http://support.tannoy.com
DONOTSHIPANYPRODUCTTOTANNOYWITHOUTPREVIOUSAUTHORISATION
PLEASENOTE:Inordertodirectyoutotheappropriateservicefacilityareturnauthorizationandinstructions
mustbeissuedinadvance-donotsendanyequipmenttoanyTannoyorTCGroupAmericasfacilitywithout
priorauthorizationoritwillberefused.Insomecasesalocalservicefacilitycanberecommended.
Ourpolicycommitsustoincorporatingimprovementstoourproductsthroughcontinuousresearchand
development.Pleaseconrmcurrentspecicationsforcriticalapplicationswithyoursupplier.
44
CVS (EN54) Manual de instrucciones rev 1.1.1
Índice
3 English-OperationManual
17 Français-Moded’emploi
31 Deutsch-Betriebsanleitung
45 Español - Manual de instrucciones
tannoypro.com
6481 0649/251115
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing
methods will always equal or exceed the published specications. All specications are subject to change without notice.
Copyright (c) 2015 Music Group Innovation SC Ltd. All rights reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

Tannoy CVS 6 (EN 54) User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI