Page 4 40663-0-0819
INTRODUCTION
Consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of an
unvented replace with exterior decorative front.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1.*/
NFPA 54.
*Available from the American National Standards Institute, Inc.
1430 Broadway, New York, N.Y. 10018.
INSTRUCTIONS TO INSTALLER
1. You must read and understand the framing section of the
replace installation instructions before proceeding with the
installation of this decorative front.
2. Leave instruction manual with owner after installation.
3.
Have owner register online or ll out and mail Product
Registration Card supplied with unvented replace.
4. This decorative front is for installation on an exterior wall only.
5. This decorative front must be installed on to the replace
prior to placing the replace into the wall.
OPTIONAL ADDITION OF R-13 INSULATION (NOT INCLUDED).
NOTICE: Insulation is not required, but can be added if desired.
1. Remove the decorative front from its packaging and place
exterior face down on scratch-free surface to protect the
stainless steel.
2. Cut strips of R-13 insulation to the dimensions shown below
.
3. Remove combustible insulation backing if necessary.
4. Insert insulation strips into the voids in the Outer Face.
Use spray adhesive to hold in place prior to installing the
kit to the unit.
57 3/8 X 1”
36 X 7 3/4
57 3/8 X 11 1/2
TOP
TOP
OPTIONAL - ADDING R-13 INSULATION